JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2021101106195None · noneSHIP 6807 CORROSION ON FRAME STA 1300 BTW STG 27 TO 25 LH AT AFT CARGO COMPARTMENT (C2). CORRECTIVE ACTION: SUMMARY OF NRC 00226: CORROSION ON FRAME STA 1300 BTW STG 27 TO 25 LH AT AFT CARGO COMPARTMENT WAS REPAIRED (PERMANENT REPAIR) PER ER/A 594655-14AD REV.SDR 2A6R202110086103None · crackedDURING INSPECTION FOUND A CRACK IN THE TAIL CONE UPPER FRAME 7 ON THE FLANGE. REPAIRED FRAME 7 IAW AIRBUS HELICOPTERS RDAS-EC135-53-2021-3502SDR SWIA202163054None · corroded*FS.280 CROSSBEAM FLOOR PANEL SUPPORT ANGLE IS CORRODED (C-CHECK RO 12/07/2021) REMOVED AND REPLACED NEW FLOOR PANEL SUPPORT ANGLE AT FS 280.00 REF CRJ700 SRM 51-42-06-001-001-A01 AND CRJ700 SRM 51-42-21-001-001-A01. DWG CC670-34010 REV K. COMPLIED WITHSDR SWAA2021112227909Frame Splice · corrodedCORROSION ON FRAME SPLICE AT AFT CARGO BAY BS787 RBL25 WL158. ; / [01] CORROSION ON SPLICE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.; [02] VERIFIED CORRECTIVE ACTION STEP 1.; [03] REMOVED ACB FRAME SPLICE BS787; RBL25; WL158. PER SRMSDR SWAA2021110427411Frame · crackedCRACK ON FRAME BS 500C STR 8L AIR CONDITIONING RAIL BRACKET OUTBD ATTACH HOLE. CRACK EXTENDS UP .300' AND DOWN .300' FROM INBD EDGE OF HOLE. NOT IN FRAME RADIUS. ; / [01] REPAIRED ON CARD TTG8Q006QK4S; [02] VERIFIED BS500C STR8L REWORK PERFORMED ON CC# TTG8Q00SDR DALA2021110306773None · noneSHIP 3265 COMPLY WITH MONITOR INSPECTION LOG REFERENCE ER/A 594128-14. CORRECTIVE ACTION: COMPLIED WITH MON INSPECTION. (1975654)SDR DALA2021101106192None · noneSHIP 6807 ERA 594655-14 SECTION I ISSUED FOR REPAIR TO STA 1300 FRAME AT L 26L. CORRECTIVE ACTION: REF ERA 594655-14. (1975278)SDR MASA20211008469None · noneHYDRAULIC BAY FUSELAGE SKIN AT FS193.00 ABOVE STGR19L WAS FOUND TO HAVE SCRATCH DAMAGE. PERFORMED PERMANENT REPAIR IAW SRM 53-11-01-001-007-A01, FIGURE 53-11-01-991-807, ITEMS 1A, B, AND C, EA 79-2021-232.SDR V0XD20211007001None · corrodedMAIN AVIONICS BAY FS 319.00 FRAME CORROSION. CORRECTIVE ACTION: REMOVED CORRODED FRAME AND REPLACED WITH NEW FRAME FS319.00 FROM STR26L TO STR26R IAW BOMBARDIER REO 670-53-21-799 REV.A DATE 2016-11-27. ACCOMPLISHED ON AVMAX W/O:80955 W/C: 1140SDR SWAA2021101127328None · crackedSUPPLEMENTAL INFORMATION: UPON COMPLETION OF HFEC INSPECTION; FOUND 1 INCH CRACK AT BS 666 RBL 40 WL 203 COMMON TO THE HORIZONTAL PRESSURE DECK / PERFORMED INSURANCE CUTDVIFABRICATED REPAIR PARTS DOUBLER(-1) FROM MATERIAL 2024 T3 CLAD 0.080' LOT.#1467098-1WEB SDR SWIA202162514None · corroded*DOOR POST LOCATED AT APPROXIMATELY FS280 RBL11 CORRODED ON LOWER SECTION (MARKED) (C-CHECK RO 11/10/2021) REMOVED LIGHT CORROSION ON DOOR POST LOCATED AT APPROXIMATELY FS280 RBL11 LOWER SECTION. REF: CRJ-700 SRM 51-21-06-001-001-A01. NO MATERIAL LOSS,ANDSDR SWIA202162513None · corroded*DOOR POST LOCATED AT APPROXIMATELY FS280 LBL11 CORRODED ON LOWER SECTION (MARKED) (C-CHECK RO 11/10/2021) REMOVED DAMAGED SECTION - INSTALLED NEW PORTION OF THE DOOR POST AT APPROX FS280.00 LBL11.00 LOWER MEMBER. REF CRJ 700 SRM 53-11-10-201-006-A01. COMSDR SWIA202162426None · noneGALLEY SERVICE DOOR SURROUND FWD FS319.70 FRAME AT FLOOR SUPPORT FITTING, HAS MISSED DRILLED HOLE (C-CHECK RO 11-05-2021) REQUESTED ENGINEERING FOR MIS-DRILLED HOLE AT FLOOR SUPPORT FITTING, ON GALLEY SERVICE DOOR SURROUND, FORWARD OF FRAME AT FS319.70. RSDR SWAA2021110226673Frame · crackedFUSELAGE FRAME AT STA 312 ABOVE L1 DOOR CUT-OUT HAS A CRACK. ; / [01] CRACK CONFIRMED. CRACK LENGHT 0.375'. IAW B 737 NDT PART 6 51-00-00 PROCE 23. TOOL NORTEC 600. BC 172389. CALIB DUE 7-2-22.; [02] TRIM OUT DAMAGE EREA STA 312 PER SRM 53-10-07-2R-1; [03] VERSDR SWIA202163050None · corroded* PANEL 642AZ FWD IB PANEL LANDING CORRODED IN MULTIPLE SPOTS (FLAGGED). (C-CHECK RO 12/07/2021) REPLACED RH FWD ANGLE P/N CC670-10338-2 COMMON TO PANEL 642AZ PANEL. REF CRJ700 SRM 51-42-21-001-001-A01 AND DWG CC670-10320 REV F. COMPLIED WITH TASK CARD SDR SWAA2021111926961Frame · crackedL/H STRINGER 8 FRAME CRACKED BS 440 LBL 65 WL 273. ; / [01] UPDATED MEASUREMENTS TABLE.; [02] REPAIRED L/H STRINGER 8 FRAME AT BS 440 LBL 65 WL 273 PER EA 1-A53-12114 R7.; [03] COMPLETE; [04] COMPLETESDR SWAA2021111926960Frame · crackedR/H STRINGER 8 FRAME CRACKED BS 500A RBL 65 WL 273. ; / [01] UPDATED MEASUREMENTS TABLE.; [02] REPAIRED R/H STRINGER 8 FRAME AT BS 500A RBL 65 WL 273 PER EA 1-A53-12114 R7.; [03] COMPLETE; [04] ALL STEPS COMPLETESDR SWAA2021111926963Frame · crackedR/H STRINGER 8 FRAME CRACKED BS 787 RBL 65 WL 273. ; / [01] UPDATED MEASUREMENTS TABLE.; [02] REPAIRED R/H STRINGER 8 FRAME AT BS 787 RBL 65 WL 273 PER EA 1-A53-12114 R7.; [03] COMPLETE; [04] ALL STEPS COMPLETE.SDR SWAA2021111926962Frame · crackedR/H STRINGER 8 FRAME CRACKED BS 827 RBL 65 WL 273. ; / [01] UPDATED MEASUREMENTS TABLE.; [02] REPAIRED R/H STRINGER 8 FRAME AT BS 827 RBL 65 WL 273 PER EA 1-A53-12114 R7.; [03] COMPLETE; [04] ALL STEPS COMPLETE.SDR SWIA202162509None · crackedFRAME FS1015 LOWER FLANGE CRACKED JUST ABOVE STR18L (C-CHECK RO 11/10/2021) REPLACED FRAME FS1015 WITH NEW FRAME BETWEEN STGR19L AND FLOOR SILL REF CRJ-700 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 AND DWG# MM670-35005 REV-AJ. NO LEAKS NOTED. COMPLIESDR SIMA20211005004Frame · corrodedFRAME 16 HAS CORROSION AT FLOOR LEVEL. (LEVEL 2 CORROSION)(MAJOR REPIAR)-C/A-COMPLETE: REPAIRED PER ERS-EJ-5300-4403.SDR DALA2021101106183None · noneSHIP 6807 HIDDEN CORROSION: CORROSION ON FRAME STA 900 BTW RBL 24 TO LBL 38 AT LOWER BODY FAIRING AREA ( IN REF NRC 00645)(FUS). CORRECTIVE ACTION: SUMMARY OF NRC 00833: CORROSION ON FRAME STA 900 BTW RBL 24 TO LBL 38 AT LOWER BODY FAIRING AREA WAS REPAIRED (PSDR CALA2021100601794Fitting · noneR2 DOOR LOWER SILL FWD CORNER FITTING HAS CORR - A3NB-53-3-6033 - NR 9294554 (28554) GENERATED BY V061334 AT HAECO LCQ. REMOVED & REPLACED WITH NEW R-2 DOOR LOWER SILL FWD CORNER FITTI N PER A320 UAL SRM 51-42-11/001. DOT REMOVED. ACCOMPLISHED BY V0 61737, INSSDR DALA2021100606099None · noneSHIP 3209 RH FRAME 20 AT DOOR STOP FITTING #1 SHOWS CRACK INDICATIONS IN INTERCOSTAL LAYER AT HOLES #1 AND #2. CORRECTIVE ACTION: COMPLIED WITH ERA 594479-14AD REV 0. (1972737)SDR DALA2021100606098None · noneSHIP 3209 RH FRAME 16 AT DOOR STOP FITTING #7 SHOWS CRACK INDICATIONS IN INTERCOSTAL LAYER AT HOLES #1 AND #3. CORRECTIVE ACTION: COMPLIED WITH ERA 594479-14AD REV 0. (1972736)SDR DALA2021100606097None · noneSHIP 3209 BHEC INSPECTION OF LH FRAME 20 AT DOOR STOP FITTING #7 SHOWS CRACK INDICATIONS IN FRAME AND INTERCOSTAL LAYERS AT HOLE #1. CORRECTIVE ACTION: COMPLIED WITH ERA 594479-14AD REV 0. (1972734)SDR DALA2021100606096None · noneSHIP 3209 LH FRAME 16 AT DOOR STOP FITTING #7 SHOWS CRACK INDICATIONS IN INTERCOSTAL LAYER AT HOLES #1 AND #3. CORRECTIVE ACTION: COMPLIED WITH ERA 594479-14AD REV 0. (1972733)SDR CALA2021100601779Fitting · corrodedR2 DOOR LOWER SILL AFT CORNER FITTING HAS CORR - A3NB-53-3-6033 - NR 9294552 (28552) GENERATED BY V061334 AT HAECO LCQ. REMOVED AND REPLACED R2 DOOR LOWER AFT CORNER FITTING IAW A320 S RM 51-72-11-911-001 PAR. 2D REMOVED DOT. ACCOMPLISHED BY V074845 , INSP BY SDR DALA2021100506073None · noneSHIP 3209 FUSELAGE / FR 20 / L-1 DOOR OPENING / STOP FITTING #7 / CRACK INDICATION AT HOLE #1. CORRECTIVE ACTION: COMPLIED WITH REPETIVE INSPECTION PER ERA 594479-14AD. CONTINUE ON MON. OK FOR CONTINUED SERVICE. (1971568)SDR SWIA202163784None · damagedFRAME @ FS 517.00 BETWEEN STR 18L & STR 19L BLISTERED PAINT /DEBRIS BUILD-UP. CLEAN & RE-INSPECT. (C-CHECK RO 1/13/2022) REMOVED, FABRICATED AND INSTALLED STUB FRAME AT FS517 FROM STGR18L AND SGTR19L. REF CRJ700 SRM 51-42-06-001-001-A01 AND SRM 51-42-2SDR 2021FA0000278Frame · crackedNOSE WHEEL WELL FRAME IS CRACK ON LEFT AND RIGHT SIDES AT FUSELAGE STATION 75.SDR SWIA202162895None · corroded*CORROSION ON FRAME FS 969.00 BETWEEN STGR 26L €“ 22R (C-CHECK RO 11-27-21) REMOVED DAMAGED SECTIONS OF FRAME FS969 BETWEEN STGR 25L AND 20R. REF. CRJ700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01. INSTALLED 2 EA. NEW FRAME SECTIONS AND ALL RESDR SWIA202162894None · corroded*CORROSION ON FRAME 1000.00 BETWEEN STGR 24R €“ 22L (C-CHECK RO 11-27-21) REMOVED AND REPLACED WITH NEW 3 EA FRAME SECTION SPLICED CORROSION ON FRAME 1000.00 BETWEEN STGR 24R €“ 22L REF CRJ-700 SRM 51-42-06-001-001-A01,51-42-21-001-001-A01,DWG#MM670-360SDR SWIA202162893None · corroded*EVIDENCE OF CORROSION EXIST ON FRAME @FS349.00 BETWEEN STRG 26L & STRG 27R. (C-CHECK RO 11-27-21) REMOVED & REPLACED WITH NEW FRAME EVIDENCE OF CORROSION EXIST ON FRAME @FS349.00 BETWEEN STRG 26L & STRG 27R REF CRJ-700 SRM 51-42-06-001-001-A01 & DWG SH69SDR SWIA202162890None · corrodedEVIDENCE OF CORROSION FOUND JUST RIGHT OF STRINGER 27 ON FLANGE OF FRAME AT STATION 310 (C-CHECK RO 11-27-21) REMOVED & REPLACED WITH NEW FRAME EVIDENCE OF CORROSION FOUND JUST RIGHT OF STRINGER 27 ON FLANGE OF FRAME AT STATION 310 REF CRJ-700 SRM 53-00-0SDR SWIA202162795None · corrodedCORROSION ON RH FS379 FRAME ATTACH FLANGE BETWEEN STGR22R & 23R INSIDE WATER WASTE DOOR SURROUND STRUCTURE (C-CHECK RO 11-24-21) REMOVED AND INSTALLED NEW RH FS379 FRAME BETWEEN STR 25R TO STR 20R. REF: CRJ700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-SDR SWIA202162428None · damagedPERFORM SPLICE REPAIR FOR FS565.00 FRAME BETWEEN STR26R-26L. (C-CHECK RO 11-05-2021) PEFORMED SPLICE REPAIR FOR FS 565.00 BETWEEN STGR 26R - 26L REF REO 670-53-31-721 REV -- DATE 2021-10-04 AND CRJ700 SRM 53-00-06-201-001-A03.COMPLIED WITH TASK CARD 51-900SDR UIEA2021092002056Frame · crackedM/D R5 DOOR CUTOUT STR 25R AREA LOWER REVEAL FRAME FOUND CRACKED. M/D STA 2231 R5 DOOR FWD FRAME LOWER FRAME REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02 AND RI-53-60-14916 REV A.SDR UIEA2021092302087Skin · crackedEMP - TAIL CONE LH EXTERNAL SKIN AT STA 2658 STR 12L FOUND CRACKED.(<P>EMP - TAIL CONE LH EXTERNAL SKIN AT STA 2645 TO 2658 STR 11L - 13L SKIN REPAIRED IAW RI-53-00-14960 REV A</P>)SDR 2021F00247Frame · crackedFRAME, FS333.00, S1R-S2R, PN SH670-31356-5, CL600-2D24, FOUND CRACKED IN THE UPPER SECTOR OF THE FRAME AT FS333.00 BETWEEN S1R AND S2R. THE CRACK MEASURES 2.50” IN LENGTH. THE FRAME IS FORMED FROM 0.050" 7075-T62 AL ALLOY.SDR SWIA202162794None · corrodedCORROSION ON FRAME AT FS517 BETWEEN STR 24L AND STR 25L (C-CHECK RO 11-24-21) COMPLIED WITH REPAIR REF MHIRJ REO 670-53-31-723 REV--, DATED: 2021-10-05.SDR SWAA2021111725830Stub Frame · crackedFORWARD GALLEY DOOR (R1) AT FWD UPPER STUB FRAME HAS A CRACK ; / [01] LOCATED AND DRILL HOLE NEW STUB FRAME AS PER SRM 51-40-05-0G-0; [02] LATE ENTRY REMOVED UPPER STUB FRAME AS PER SRM 51-40-02-0G-0; [03] VERIFIED STEP 1 AND 2.<BR>OK TO TOP TREAT AND PRIME NESDR R61A2021102000817Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND INTERIOR FUSELAGE FWD CARGO SHEAR CLIP ON FR 16 BTWN STR 28-27R FOUND CORRODED. MX REPLACED SHEAR CLIP PN 170-03859-002 IAW SRM 51-41-01 SEE AAR NRC# 4500970-1000-0182 FOR WORK PERFORMED. AC WAS RTSSDR R61A2021102000814Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND INTERIOUR FUSELAGE FWD CARGO SHEAR CLIP ON FR 16 BTWN STR 28-27L FOUND CORRODED. MX REPLACED SHEAR CLIP PN 170-03859-001 IAW SRM 51-41-01, 51-41-02. SEE AAR NRC# 4500970-1000-0180 FOR WORK PERFORMED. AC WAS RTS.SDR R61A2021101700808Shear Angle · corrodedDURING HEAVY CHECK MAINTENANCE FOUND INTERIOR FUSELAGE FWD CARGO SHEAR CLIP ON FR17 BETWEEN STR 28-27R CORRODED. INTERIOR FUSELAGE FWD CARGO SHEAR CLIP ON FR17 BETWEEN STR 28-27R REPLACED IAW SRM 51-41-01.SDR R61A2021101700804Shear Angle · corrodedDURING HEAVY CHECK MAINTENANCE FOUND INTERIOR FUSELAGE, FWD CARGO SHEAR CLIP ON FR17 BETWEEN STR 28-27L CORRODED. INTERIOR FUSELAGE, FWD CARGO SHEAR CLIP ON FR17 BETWEEN STR 28-27L REPLACED IAW SRM 51-41-02.SDR DALA2021100506080None · noneCORROSION ON SUB FLOOR WEB STA 199 RBL 49. SUMMARY SEE NRC 058-0023:5310-2005/026 00423: REPAIRED PER ERA 594165-14 REV. O. (LP #1968423)SDR SWIA202163289None · corrodedFS 589 FRAME CORRODED BETWEEN STGR 18L AND STGR 18R. (C CHECK RO 12/28/2021) REPLACED LOWER FRAME SEGMENT AND REINFORCING ANGLE ON THE FRAME @589 BETWEEN STGR 18L AND 18R IAW CRJ 200 SRM 51-40-11, 51-42-21 AND 51-42-06, COMPLETED SKY CARD 51-900-1003-SKY, SDR SWIA202163288None · corrodedFS 605 FRAME IS CORRODED BETWEEN STGR 18L AND STGR 17R. (C CHECK RO 12/28/2021) REMOVED AND REPLACED FRAME SEGMENT, STFFENER AND REINFORCING ANGLE ON FS 605 FRAME BETWEEN STGR 18L AND 17R IAW CRJ 200 SRM 51-40-11, 51-42-06 AND 51-42-21, COMPLETED SKY CARDSDR SWIA202162789None · corrodedMAIN AVIONICS BAY FS333.00 FRAME CORRODED BETWEEN STR 26L AND STR 27 AND BETWEEN STR 25R AND STR 24R (C-CHECK RO 11-24-21) REPLACED MAIN AVIONICS BAY FS333 FRAME BETWEEN STR 21L AND 20R REF CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRM 51-42-21-001-001-A01,
Back to JASC 5311