JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20210616032Frame · corrodedAT RF1, FR65 BTW STR 15-16 LH CORROSION FOUND ON FRAME. AT RF1, FR65 BTW STR 15-16 LH CORROSION ON FRAME REMOVED AND FOUND OUT OF LIMITS. SPLICE FABRICATED. FR 65 CUT BTW STR 13L AND 15L, SPLICE CHANNEL TRIMMED AND FIT TO FRAME 65 SEGMENTS. FR 65 AND SPLICE DRSDR JJBA20210616031Frame · crackedCF4 BTW STR 15L-14L, FR 59 CRACKED. FR 59 REMOVED FOR REPLACEMENT. LH AND RH FRAME SPLICE AND FLOOR SILL RH SIDE AFT OF FR 59 REMOVED FOR ACCESS. CF4 FR59 BTW STR 15L-14L REPLACED BY NEW ONE. LH AND RH FRAME SPLICE AND FLOOR SILL RH SIDE AFT OF FR 59 REINSTALLSDR DALA2021061803318Frame Angle · corrodedSHIP 663 INITIAL INSPECTION: CORROSION ON FRAME CLIP (AFT FACE) STA 880 BTW STRINGER 28LH-28RH AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00333; CORROSION LEVEL 2 ON FRAME CLIP (AFT FACE) STA 880 BTW STRINGER 28LH-28RH AT FWD CARGO COMPARTMENTSDR DALA2021061703296Frame · corrodedAFT CARGO COMPARTMENT HAS CORROSION ON FRAME AND FRAME CLIP STA 908 BETWEEN L29L & 28R. NRC 258 - SUMMARY: REPLACED FRAME CLIP PER DWG 9915524. (LP #1842039)SDR A6WA202107097822Frame · dentedDENTS AND GOUGES ON FUSELAGE AFT FRAME FS682.00Ï¿½ STR S26L TO S27. ***AIRCRAFT REMOVED FROM SERVICE*** BLENDED GOUGE DAMAGE AND HAND DRESSED DENTS TO FUSELAGE FRAME AT FS682.00 STR S26L TO S27. DENT DAMAGE MEASURES L = 7.250Ï¿½ X W = 0.500Ï¿½ X D = 0.070Ï¿½SDR R61A2021070100528Support · corroded************THIS WAS A DUPLICATE SDR THAT WAS FILED TWICE BY MISTAKE #517 USED TWICE.**********WHILE AC WAS IN FOR HVY CK CORROSION FOUND ON CENTER FUSELAGE 3 AFT CARGO FLOOR SUPPORT SHEAR CLIP AT FR 81 AND STR 29R-29L. REPLACED SUPPORT PN 170-66354-002 IAW SRSDR SWIA2021062959185Doubler · corrodedCORROSION FOUND ON DOUBLER FWD CORNERS AT FRAME 19 LH SIDE (C-CHECK RO 6/28/2021) REMOVED AND REPLACED DOUBLER AT FRAME 19 LH SIDE REF SRM 51-40-08SDR DALA2021061603281Frame Angle · corrodedSHIP 663 CORROSION ON FRAME CLIP (FWD FACE) STA 860 BTW STRINGER 27RH - 28RH AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00908,AT STA 860 BTW STRINGER 27RH - 28RH AT FWD CARGO COMPARTMENT WAS REPLACED PER B757-200 SRM. (1841868)SDR DALA2021061603274Frame · corrodedAFT CARGO FRAME 1028 (AFT BULKHEAD) IS CORRODED ON AFT SIDE ABOVE STR30. MARKED. NRC 041-0008:5331-2001/002 00246: REPAIRED CARGO FRAME 1028 PER B717 SRM 53-20-07 REPAIR 3. (LP #1841380)SDR FDEA202106151547Frame · crackedRIGHT SIDE STATION 1640 FUSELAGE FRAME WEB SHOWS 2 EA CRACKI INDICATIONS ON THE UPPER AND LOWER INBOARD HOLES. CRACKS NOTED ONLY IN THE FRAME LAYER ACCOMPLISHED FEDEX EA# F-5310-T0361899-P1: FUSELAGE MAINFRAME - FRAME WEB STA 1640 S14R - CRACK INDICATIONSDR FDEA202106151546Frame · crackedLEFT SIDE STATION 1640, FUSELAGE FRAME WEB SHOWS 2 EA CRACK INDICATIONS ON THE UPPER AND LOWER INBOARD HOLES. CRACKS NOTED ONLY IN THE FRAME LAYER ACCOMPLISHED FEDEX EA# F-5310-T0361898-P1: FUSELAGE - MAINFRAME - FRAME WEB STA 1640 S14L - CRACK INDICATIONSDR SWIA2021082060550Frame · damagedPER CUSTOMER REQUEST, REPLACE FS 333 FRAME FROM STR 0 TO STR9R. (C-CHECK RO 8/19/2021) REPLACED FS333 FRAME STR0 TO STR9R IAW CRJ700 SRM 51-40-11,51-42-20,51-42-06 AND BOMBARDIER DRAWING SH670-31950. IAW CRJ700 AMM 20-30-00,33-51-00,33-26-00,38-10-00. SDR SWIA2021082060503Frame · corroded*CORROSION ON FS 319.00 AROUND GROUND STUDS BETWEEN STGR 20L - 19L (C-CHECK RO 8/18/2021) REPLACED FS319 FRAME BETWEEN STGR 18L AND 21L REF DWG SH670-31810 REV. Y AND CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-23-00-001-001-A01. LEAK CHECK GOOD, SDR DALA2021070703773Frame · crackedSHIP 3245 ER/A 588711-14AD REV A ISSUED FOR A CRACK ON LHS AT FR 35, BETWEEN STR 28 AND STR 31. CORRECTIVE ACTION: ACCOMPLISHED SECTION IV (INSPECTION OF REPAIR ANGLE) EVERY 15,000FC OR 30,000FH (WHICHEVER OCCURS FIRST) FOLLOWING THE ACCOMPLISHMENT OF SECTION SDR SWAA2021071982489Frame · crackedFRAME CRACKED ABOVE FED AT BS 312; LBL 32.75; WL 282.5 ; / [01] HFEC INSP CRACK IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23. VERIFIED CRACK END; AREA MARKED . EQUIP ID#: IS000450 S/N: N500D000M120071; [02] CRACK MEASURED 0.08'; REMOVED DAMAGE PER SRM 53-10-07-2RSDR FDEA202106111500Frame · crackedDURING ROTO PROBE OF OPEN HOLES AT RH BS 1640 PER EO F-5310-E0344602. A CRACK INDICATION WAS NOTED IN THE BOTTOM INBD HOLE. THE CRACK IS IN THE FRAME AT APPROX. 3:00 O'CLOCK. COMPLIED WITH EA F-5310-T0361948 AND COMPLETED ALL STEPS 1-17 FUSELAGE - MAINFRSDR DALA2025011500354Frame · not reportedSHIP 6705 SRM 53-00-07 R5 REPAIR TO BS 1640 FRAME AT S-26L REQUIRES SUPPLEMENTAL INSPECTIONS PER ERA 589526-14. CORRECTIVE ACTION: REF ERA 589526-14. (1836203)SDR SWIA202160701Frame · corrodedFRAME CORRODED AT FS 379 STRINGER 19R (C-CHECK RO 8/31/21) CORRODED FRAME SECTION FROM FS 379 WAS REMOVED AND REPLACED IAW CRJ 700 SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01 REV. 38 B DATED 12/14/2020. NO DEFECTS NOTED. FORM 337 AND MAJOR REPAIR TASSDR SWAA2021072282316Frame · crackedCRACK IN FRAME AT B.S. 727D; STRINGER 8 LEFT; AT AIR CONDITIONING ATTACH BRACKET. ; / [01] REMOVED 2 FASTENER FROM FRAME B.S. 727D ; STR 8 LEFT; AIR CONDITIONING ATTACH BRACKET IAW 51-40-02-OG-0; [02] ET INSPECTED 2EA HOLES IAW 737 NDTM PART 6 51-00-00 PROCEDUSDR SWAA2021062886454Frame Angle · puncturedAFT CARGO COMPT. L/H SIDE FRAME UPPER FLANGE PUNCTURED HOLE @ S-23L STA 767 ; / [01] TRIMED OUT DAMAGED SECTION AT STA .767 BETWEEN STR 23L AND STIR 24L CUT OUT DIMENSION 1.200 X 1.100 REF B737-700 SRM 51-10-02-0G-0; [02] VERIFIED DAMAGE CUT OUT ON FRAME UPPERSDR FDEA202106101487Frame · crackedCRACK COMES OUT FROM RIVET HOLE ON THE FRAME WEB BS 1240 BETWEEN STR 9R TO 8R PERFORMED FUSELAGE FORMED ZEE FRAME REPAIR PER SRM 53-00-07, REPAIR 3, FIG 201, DETAIL 1 DEFERRED ITEM NO 2. THIS REPAIR IS A CAT B PERMANENT REPAIR.SDR DALA2021061403224Frame · crackedSHIP 3238 CRACK INDICATION ON FRAME 68 LH AT DOOR STOP 1 IN HOLE 4 AT AFT GALLEY AREA. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR PER A320 SRM 53-41-12. (1836011)SDR AALA202208168644Window Post · none**SUPPLEMENTAL REPORT FOR AALA202106109007 AS REQUESTED BY FAA SDR REJECTION LETTER DATED 7/7/2022** AIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK RIGHT HAND SIDE #1 WINDOW FRAME C-D WINDOW POST AT BS 217 AND S5R AT WL 258 REQUIRES RE-ENFORCING MODIFICATION DOUBLESDR AALA202208160718Window Post · none**SUPPLEMENTAL REPORT FOR AALA202106109008 AS REQUESTED BY FAA SDR REJECTION LETTER DATED 7/7/2022** AIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK LEFT HAND SIDE #1 WINDOW FRAME C-D WINDOW POST AT BS 217 AND S5L AT WL 258 REQUIRES RE-ENFORCING MODIFICATION DOUBLERSDR SWIA202161751None · corrodedFS310.00 THRU FS333.00 RIGT SIE FUSELAGE STGR20R CORRODED UNERFLOOR BELOW SREVICE DOOR. (C-CHECK RO 10/9/2021) AFTER FURTHER INVESTIGATION STR20R STRINGER NOT CORRODED, CORROSION IS ON INTERCOSTAL ON STR20R FROM FS310-333. REMOVED AND REPLACED CORRODED SDR SWAA2021071981802Frame Splice · corrodedCORROSION ON FRAME SPLICE AT AFT CARGO BAY BS787 RBL24 WL158. ; / [01] EVALUATED CORROSION ON FRAME SPLICE AT BS787 RBL24 WL158 FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED OUT OF LIMITS; [03] SDR SWAA2021071682475Frame · dentedDENT ON FRAME AT FWD CARGO BAY BS420 LBL28 WL157. ; / [01] DAMAGE EVAL. FOUND DENT TO BE OUT OF LIMITS DUE TO NO DENTS PERMITTED IAW SRM 53-00-07-1A-1. TRIMMED OUT DAMAGE ON FRAME AT FCB BS420 LBL28 WL157 IN A AREA OF 1'X.090' IAW SRM 53-30-07-2R-1; [02] REMOVSDR SWIA2021081060277Frame · damagedPERFORM FRAME SPLICE REPAIR AT FS1047, STR22L TO PROVIDE ACCESS FOR REPAIR OF STR 25L AT FS 1040 (C-CHECK RO 8/9/2021) INSTALLED NEW FRAME SPLICE AT FS1047 STGR 22L REF-CRJ-700 MHI RJ REO 670-53-61-1921 REV -- DATED 2021-06-26, SRM 51-42-06-001-001 A01 SDR SWIA2021081060276Frame · damagedSPLICE REPAIR OF FRAME SECTOR FS501.00 AT STGR -16R COMMON TO JOB 71004994 OP 63 MX # 22779504 (C-CHECK RO 8/9/2021) PERFORMED SPLICE REPAIR OF THE FRAME SECTOR AT FS501.00 STGR 16R REF REO 670-53-31-671 REV -- DATED 2021-06-05. PRESSURE LEAK CHECK GOSDR SWIA2021081060275Frame · damagedSPLICE REPAIR OF FRAME SECTOR FS565.00 AT STGR-16R COMMON TO JOB 71004994 OP 61 MX# 22779485 (C-CHECK RO 8/9/2021) PERFORMED SPLICE REPAIR OF FRAME SECTOR FS 565 AT STGR 16R REF REO 670-53-31-671 REV-- DATED 2021-06-05 / COMPLIED WITH TASK CARD 51-900-SDR DALA2021060903144Frame · crackedSHIP 6807 CRACK INDICATION NOTED AT LH STA 1640 STR 14L LOWER OUTBOARD HOLE COMMON TO THE OUTER CHORD FRAME WEB LOWER HINGE FITTING AND TEE CLIP AT THE 3OCLOCK POSITION LOOKING FWD. CORRECTIVE ACTION: REPAIRED L/H STA 1640 FRAME IAW ERA 591997-14AD REV ORIGINASDR MASA20210607227Frame · corrodedFORWARD E&E BAY FRAME AT FS310 STGR 26L AND 26R |REMOVED AND REPAIRED FRAME SECTOR FS310 BETWEEN STGR 25R AND 25L IAW SRM 53-00-06SDR CALA2021060700809Frame · crackedCRACK/BUSH REPAIR AT RH FRAME 16 DOUBLE JOGGLE AREA OUTER FLANGE FASTNER HOLE CRACK REF EC/RA #5100-03068 CSN INTERNAL REPAIR LIS T FIG 5 ITEM 53-005 REF HAECO NRWC 9440148 ACCOMPLISHED GVI WITH NO FINDINGS VALIDAT ED THE REPAIR REFERENCE RDAS 80294360/003/201SDR CALA2021060700807Frame · crackedCRACK/BUSH REPAIR AT RH FR16 DOUBLE JOGGLE AREA OUTER FLANGE FA STENER HOLE CRACK REF ECRA 5100-03068 CSN INTERNAL REPAIR LIST FIG 5 ITEM 53-005. REF HAECO NRWC9440148 ACCOMPLISHED GVI WITH NO FINDING VALIDATED REPAIR. REF AIRBUS RDAS 80294360/003/2017 ISSUE ASDR SWIA2021081860314Drag Angle · cracked* LH VERTICAL STAB TO FUSELAGE AFT DRAG ANGLE HAS SUSPECTED CRACK (C-CHECK RO 8/16/2021) PERFORMED REPAIR PER REO 670-55-31-018 REV - A 2016-11-10. COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA2021080259959Frame · corrodedANGLE CLIP AT FRAME 349.00 COMMON TO BACK UP SILL HAS CORROSION (C-CHECK RO 7/28/2021) REPLACED ANGLE CLIP AT FRAME COMMON TO BACKUP SILL REF DWG SH670-31810 REV.AE AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY.SDR REXA2021062900433Frame · corrodedFRAME AT FS 295.00 IS CORRODED FROM STR L26 TO STR26. REMOVED CORROSION AT FRAME FS 295 FROM STR L26 TO R26 IAW CRJ SRM 53-00-06-201-006-A01. WVAC EMP # 56399SDR V0XD20210606009Frame · corrodedMAIN AVIONICS COMPARTMENT FR 310 BETWEEN STGR 26L AND 26R IS CORRODED. CORRECTIVE ACTION: REPAIRED FR 310(PN:SH670-31354-3S) BETWEEN STGR 26L AND 20R IAW BOMBARDIER REO 670-53-21-799.SDR V0XD20210606008Frame · corrodedMAIN AVIONICS COMPARTMENT FR 319 BETWEEN STGR 26L AND 25R IS CORRODED. CORRECTIVE ACTION: REPAIRED FR 319(PN:SH670-3155-1) BETWEEN STGR 26L AND 25R IAW BOMBARDIER REO 670-53-21-799.SDR SWAA2021071280228Frame · corrodedCORROSION ON FRAME AT AFT CARGO BAY BS947 LBL9 WL178. ; / [01] UPDATED MEASUREMENT TABLE; [02] REMOVED CORROSION ON BS 947 FRAME LBL 9 WL 178 3'X1' PER SRM 53-00-07-1A-1; [03] VERIFIED REMOVED CORROSION ON BS 947 FRAME LBL 9 WL 178 3'X1' PER SRM 53-00-07-1A-1;SDR SWAA2021071280251Frame Splice · corrodedCORROSION ON SPLICE AT AFT CARGO BAY BS787 RBL25 WL158. ; / [01] UPDATED DAMAGE TABLE; [02] REPLACEMENT OF PART DUED NO ALLOWABLE DAMAGE GIVEN IN SRM; [03] REMOVED FRAME 787 R.H. SPLICE PER SRM 51-40-02; [04] LOCATED AND DRILLED NEW FRAME SPLICE P/N 146A1300U3SDR SWAA2021070781189Frame · dentedDENT ON FRAME AT AFT CARGO BAY BS747 3' BELOW S-23L WL163. ; / [01] UPDATED DAMAGE TABLE; [02] FRAME IS FOUND OUT OF LIMITS DUE TO NO DENT DAMAGE ALLOWED ON FRAMES PER SRM 51-00-07-1A-1; [03] CUT AND REMOVED DAMAGE FRAME BS 747 3' BELOW STR 23L MEASURING 1.1'XSDR IPXA2021070171180Frame · dentedINSPECTION TYPE:3CMAIN CABIN FUSELAGE FRAME AT STA 740 & LONGERON 12R IS DENTED.REPAIRED DENTED MAIN CABIN FUSELAGE FRAME AT STA 740 & LONGERON 12R IAW VT-SAA EA 011-5310-01-A9184 REV. IR AND UPS EO MD11-5310-80867-A. REF. FAA FORM 9100-9 SIGNED BY: STEPHEN KASDR SIMA20210603004Frame · damagedFRAME 67 HAS 2EA ELONGATED HOLES AT THE END OF THE FRAME THAT CONNECTS TO CARGO DOOR SILL.-C/A-REPAIRED IAW SRM 53-00-04.SDR SIMA20210603001Frame · damagedFRAME 66 HAS 2EA ELONGATED HOLES AT THE END OF THE FRAME THAT CONNECTS TO CARGO DOOR SILL.-C/A-INSTALLED NEW FRAME SECTION AND SPLICE AT FR 66 IAW SRM 53-00-04 FIG 201.SDR IPXA2021061170413Frame Angle · crackedINSPECTION TYPE:C3CENTER CARGO FRAME ANGLE CRACK AT STA.1701 LON 41L.REMOVED,FABRICATED AND REPLACED CRACKED FRAME ANGLE IAW SRM 51-31-01 AND 51-35-01 (MINOR).SDR FDEA202106011426Frame · crackedLEFT HAND FORWARD FUSELAGE FRAME AT AIRCON PACK #1 COMPARTMENT STATION 547 LONGERON 33 LEFT - LONGERON 34 LEFT FOUND CRACKED. LEFT HAND FORWARD FUSELAGE FRAME AT AIRCON PACK #1 COMPARTMENT STATION 547 LONGERON 33 LEFT - LONGERON 34 LEFT REPAIR CARRIED OUTSDR DALA2021080304393Frame · crackedSHIP 670 REF ERA 591770-14AD WHILE PERFORMING INSPECTIONS, CRACK INDICATIONS WERE FOUND AT STA 1640 FRAME LOWER OUTBOARD HOLE COMMON TEE CLIP AND S-14R LEVEL. CORRECTIVE ACTION: REF ERA 591770-14AD. (1825476)SDR DALA2021060303051Frame · crackedSHIP 685 IN REFERENCE TO WO 5311-01218-01B CRACK WAS FOUND IN LOWER INBOARD HOLE (AT 02:00 CLOCK POSITION) AT RH FRAME STGR 14 BS 1640. CORRECTIVE ACTION: SUMMARY OF NRC 00418: RH FRAME ON STGR 14 STA 1640 WAS REPAIRED PER ER/A: 591892-14AD REV.ORIGINAL SECTIOSDR DALA2021060203019Frame · damagedSHIP 670 R/H FRAME STA 1640 LWR O/B OPEN HOLE HAS AN INDICATION OF DEFECT NOTED AT THE 3 OCLOCK POSITION LOOKING AFT. CORRECTIVE ACTION: REPAIRED RH FRAME STA1640 STR9- STR20R IAW DELTA ERA 591770-14AD. REV O. (1825727)
Back to JASC 5311