What was found
ANGLE CLIP AT FRAME 349.00 COMMON TO BACK UP SILL HAS CORROSION (C-CHECK RO 7/28/2021) REPLACED ANGLE CLIP AT FRAME COMMON TO BACKUP SILL REF DWG SH670-31810 REV.AE AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ANGLE CLIP AT FRAME 349.00 COMMON TO BACK UP SILL HAS CORROSION (C-CHECK RO 7/28/2021) REPLACED ANGLE CLIP AT FRAME COMMON TO BACKUP SILL REF DWG SH670-31810 REV.AE AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY.