JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20120119TUL04Frame · crackedSTATION 400 BELOW STRINGER 8 RIGHT, FRAME CRACKED AT BIN RAIL ATTACH BRACKET RIVET HOLES. INSTALLED DOUBLER PER ECO J1159AD.SDR AALA20120105TUL25Frame · crackedSTATION 500D RIGHT FRAME CRACKED AT BIN RAIL ATTACH BRACKET RIVET HOLES. INSTALLED DOUBLER PER ECO J1159AD.SDR LR7A2012011700344Frame Splice · corrodedDURING SCHEDULED C-10 CHECK AND CENTER WING REPLACEMENT, FOUND CABIN RING SEGMENT SPLICE CORROSION FS617, WL283, RBL20. REPAIR BY REPLACEMENT, ACCOMPLISHED IAW SMP583 CHAPTER 51-70.SDR LR7A2012011700338Frame · damagedDURING SCHEDULED C-10 CHECK AND CENTER WING REPLACEMENT, FOUND RT CABIN RING FRAME CRACKED EXCESS DOUBLER HOLES AT FS437, WL283, RBL20. REPAIR ACCOMPLISHED IAW SMP583 FIG 51-140-21.SDR LR7A2012011700295Frame · crackedDURING SCHEDULED C-10 CHECK AND CENTER WING REPLACEMENT, FOUND CABIN OVERHEAD RING SEGMENT AT FS 477, LBL 18, WL 282. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP 583 CH 51-70.SDR LR7A2012011700294Frame · crackedDURING SCHEDULED C-10 CHECK AND CENTER WING REPLACEMENT, FOUND CRACK IN CABIN OVERHEAD LT RING SEGMENT FS 477, LBL 22, WL 282. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP 583, CH 51-60 & 51-70.SDR LR7A2012011700280Frame · crackedDURING SCHEDULED C-10 CHECK AND CENTER WING REPLACEMENT, FOUND LT AFT FUSELAGE INTERIOR RING SEGMENT CRACKED FS 817E, WL 158, LBL 63. REPAIR ACCOMPLISHED IAW SMP583, FIG 53-40-46.SDR AALA20120113TUL04Beltframe · crackedBELTFRAME CRACKED AT STATION 440L AT INBOARD BRACKET RIVET HOLE. INSTALLED REPAIR DOUBLER PER ECO J1159AD.SDR FDEA201201050027Frame · damagedFRAME 16A RT DAMAED. REMOVED FRAME IAW SRM 51-40-21, PG 1 AND EA 6-5310-135257B. LOCATED AND DRILLED NEW FRAME IAW SRM 51-40-44, PG 9. INSTALLED NEW FRAME IAW SRM 51-40-21, PG 19 AND EA 6-5310-135257B, STEP 18, PG 4.SDR CA120105001Frame · cracked(CAN) DURING INSPECTION CHECKS, MAINTENANCE PERSONNEL DISCOVERED A CRACK ON UPPER FUSELAGE FRAME AT BS 447 LBL AND RBL 27. REO 215-53-10-198 AND 215-53-10-203 WERE RAISED TO PROVIDE INSTRUCTIONS FROM OUR ENGINEERING DEPARTEMENT.SDR COEA2012010408801Frame · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: FRAME 36 AT STRINGER 14R CORRODED, STRINGER CLIP AT STR 18 REQUIRES REPLACEMENT DUE TO INTERFERENCE WITH FRAME SPLICE (LENGTH 6", WIDTH 2", DEPTH .050"). REMOVED CORROSION, REPLACED FRAME SEGEMENT WITH OEM PARSDR DALA1212063602Frame · damagedWORKING ERA 484067-14 REV B HAD TO REMOVE DOUBLERS FROM PREVIOUS REPAIR INSTALLED ON SAME ERA WHICH FAILED DTA. REMOVED DOUBLES AND FOLLOWED INSTRUCTION REF AS PRI 484067-14 REV C. INSTALL AND SIGNED OFF A FOLLOWED INSTRUCTIONS AS OUTLINED IN ERA 484067-14 RSDR SWAA1201005Frame · crackedCRACK FOUND AT BS 616 FRAME INNER CHORD LT SIDE WL 221. REPAIRED FRAME IAW EO AND EA.SDR SWAA1201003Frame · corrodedCORROSION ON FRAME LOCATED AT BS 500A BETWEEN S 28L AND S 28R FWD CARGO COMPARTMENT. REPAIRED FRAME IAW SRM AND DWG.SDR IPXA2571167Frame · dentedINSPECTION TYPE:C-CK, FWD CARGO LT STA 800 FRAME DENTED 2 LOCATIONS 20" AND 24" FROM FLOOR. REPAIRED FRAME IAW SRM 53-00-07-2R-5, REPAIR 5, DETAIL 1.SDR IPXA12571076Frame · dentedINSPECTION TYPE:C-CK, FWD CARGO LT STA 680 FRAME DENTED 11" FROM FLOOR. REPAIRED FWD CARGO LT STA 680 FRAME IAW SRM 53-00-07-2R, REPAIR 5, DETAIL 3.SDR IPXA12571070Frame · dentedINSPECTION TYPE:C-CHECK, FWD CARGO LT STA 680 FRAME DENTED 11" FROM FLOOR. REPAIRED FWD CARGO LT STA 680 FRAME IAW SRM 53-00-07-2R, REPAIR 5, DETAIL 3.SDR IPXA12570983Frame · dentedINSPECTION TYPE:CK, FWD CARGO LEFT BS 720 FRAME DENTED 20" FROM FLOOR CUT OUT DAMAGE, CUT OUT MEASURES 1.1" X 1.0" FABRICATED REPAIR DOUBLER FROM 7075-0-.071 AND HEAT TREATED TO T6 CONDITION, REPAIR DOUBLER FNA L LENGTH IS 11" REPAIR INSTALLED IAW SRM 53-00-0SDR ASOA201200022Frame · corrodedCORROSION FOUND ON FRAME AT FS 310 FROM S25R TO S25L. R & R FRAME SECTION IAW SRM 53-21-06-101-002-A02 AND REO 670-53-21-790.SDR COEA2012010302801Frame · corrodedHEAVY CK COE / LEVEL 2 CORROSION: FRAME 44 HAS CORROSION ON AFT SIDE BL 0, BOTH SIDES OF THE FLOORBOARD FLANGE AND THE UPPER FLANGE OUTBOARD OF LT & RT OUTBOARD SEAT TRACKS (LENGTH 5", WIDTH 2", DEPTH .05"). REMOVED CORROSION AND REPLACED FRAME WITH OEM PART.SDR JR2R2012010300001Frame · corrodedFS 517 STUB FRAME CORRODED BETWEEN FBBD LINTEL AND UPPER LONGERON. REMOVED CORRODED STUB FRAME AT FS517 BTWN FBBD LINTEL AND UPPER LONGERON AND INSTALLED NEW IAW SRM 51-42-21.SDR UIEA2012011900019Frame · damagedDISTORTED ON THE FRAME OF MAIN DECK CARGO COMP AT STA 1840 S11R. REPAIR IAW EO NR T2012A53B-087 REV 00. AND REV 01.SDR UALA2012010300011Frame · corrodedCORROSION ON FRAME STA 916, NEAR STR 20L. CORROSION OUT OF LIMITS, FABRICATED AND INSTALLED REPAIR PER SRM ON PEMCO NR 3872N 00597.SDR DALA1171640194Strap · crackedFOUND AT PSV, (REF OPN 8701) CRACK IN FAIL SAFE STRAP RT WHEEL WELL STA 955. REPAIRED PER ERA 498766-14AD. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPSSDR QXEA2011123001450Frame Splice · damagedDAMAGED STRAP SPLICE BETWEEN STRINGERS 28P AND 28S AT FUSELAGE STA X-21.300 TO X-18.250 REQUIRES REPLACEMENT IAW MFG. REMOVED STRAP SPLICE IAW SRM 51-42-05-02-01. FABRICATED NEW STRAP SPLICE IAW DWG 85300602. INSTALLED NEW STRAP SPLICE IAW SRM 51-42-05-02-0SDR CA120314002Frame · cracked(CAN) CRACKING OF TOP FRAME SEGMENT, BS 447, RBL 27.SDR CHQA201200009Frame · crackedDURING INSPECTION, THE COCKPIT LEFT FRAME 10, JUST BELOW THE SIDE WINDOW WAS FOUND CRACKED. THE COCKPIT LEFTD FRAME 10, JUST BELOW THE SIDE WINDOW, WAS REPLACED. THE NEW PART WAS INSTALLED WITH A SOLID RIVET IN ACCORDANCE WITH SRM 51-40-02.SDR SWAA120029Frame · crackedDURING SCHEDULED 16Y CHECK FOUND, LT FRAME I/B CHORD CRACKED AT BS 348, WL 208.5. REMOVED AND REPLACED CHORD IAW SRM.SDR IPXA2571149Frame · dentedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FRAME AT STA 600, STRINGER 16R DENTED. CUT OUT DENT. FABRICATED AND INSTALLED REPAIR IAW EA 111751 IR AND EO B757-5310-45583-A.SDR USAA2012010900011Frame · crackedQ6 CHECK - CRACK ON FUSELAGE FRAME AT BS 663.75, S2L. REPAIRED FUSELAGE FRAME AT BS 663.75, S2L IAW EA 103552 & B737 SRM 53-00-07 REPAIR 9.SDR QXEA2011123001453Frame · corrodedFRAME 1.0 FLANGES ARE CORRODED STR 31P TO 31S. REMOVED CORROSION IAW 51-21-00-00-01. MINIMUM REMAINING THICKNESS NOTED .045", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344. CSDR QXEA2011123001456Frame · corrodedFRAME 94.8 FLANGES ARE CORRODED STR 31P TO 30S. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .036", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. SDR QXEA2011123001455Frame · corrodedFRAME 258.5 FLANGE IS CORRODED STR 27P TO 28P. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .037", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRSDR QXEA2011123001454Frame · corrodedFRAME 547 FLANGE IS CORRODED STR 24S TO 23S. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .060", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. COMPLETSDR USAA2011122900018Frame · crackedFPBH/CDFI VISIT - CRACK IN FUSELAGE FRAME AT BS 500E BETWEEN S20R TO S21R. REPAIRED FUSELAGE FRAME AT BS500E BETWEEN S20R TO S21R IAW B737 SRM 53-00-07-2R-13.SDR ASOA201102450Frame · corrodedFRAME FS 349 CORRODED BETWEEN S24L TO 24R. REMOVED CORROSION.SDR ASOA201102448Frame · corrodedFRAME FS 364.00, CORRODED FWD SIDE BEWTEEN ST 26L AND 26R. REMOVED CORROSION FROM FRAME IAW SRM 51-21-06. FOUND TO BE WITHIN LIMITS IAW SRM 51-21-06. APPLIED ALODINE, PRIMER & TOP COAT IAW SRM 51-21-11.SDR QXEA2011123001448Frame · corrodedFRAME -18.25 FLANGES AND VERTICAL SURFACE ARE CORRODED STR 29P TO 28S. REMOVED CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS .037" CONFIRMED CRACK FREE IN BLEND AREA REF NTM 51-00-02-250-801 AND 51-00-02-250-801. BLENDED FOUND TO BE WITHIN LIMITS IAW RDSDR DALA1202851604Frame · crackedM/D STA 903 STR 20L-STR 21L FRAME INNER CHORD CRACKED. REPAIRED PER ERA 497674-14 REV ORIG.SDR QXEA2011123001457Frame · corrodedFRAME 584.5 FLANGES ARE CORRODED STR 32P TO 31S. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .042", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344. SDR NSVA2011367Frame · corrodedTHE AFT UPPER FLANGE ON THE BOTTOM FRAME AT ATA 258 HAS PREVIOUS REPAIR NOT IN DAMAGE LOG OR ON FILE. BOTH FORWARD AND AFT UPPER FLANGES HAVE SEVERE CORROSION FROM LBL 10.5 TO RBL 15.13. NUMEROUS RIVET HOLES IN THE VERTICAL WEB FROM THE PREVIOUS REPAIR ARE MSDR QXEA2011123001452Frame · corrodedFRAME 604.5 FLANGE IS CORRODED STR 31P TO 32P. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .045", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344. CSDR QXEA2011123001451Frame · corrodedFRAME 604.5 FLANGE IS CORRODED STR 31S TO 32S. REMOVED CORROSION IAW 51-21-00-00-01. MINIMUM REMAINING THICKNESS NOTED .045", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344. CSDR NSVA2011361Frame · crackedFUSELAGE BOTTOM FRAME AT STA 294 HAS MODERATE TO SEVERE CORROSION FROM LBL 25 TO RBL 10.5 AND A CRACK AT RBL 19.5. REFER TO SAAB STATEMENT 340SDS023466 DATED 12-14-2011, TD 340-53-11-93 AND MM409#407125 FOR REPAIR DETAILS UNDER CONTROL# 202-25.SDR QXEA2011122801438Frame · corrodedFRAME 49.5 FLANGES ARE CORRODED STR 33 TO 31S. BLENDED CORROSION IAW RD 8/4-53-2344. FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344. TRIMMED OUT FLANGE IAW RD 8/4-53-017. FLANGE IS WITHIN LIMITS, ORIGINAL THICKNESS .050", REMAINING THICKNESS .047" IAW RD 8/4SDR QXEA2012010201458Frame · corrodedFRAME 196 FLANGES ARE CORRODED STR 31P TO 33. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .036", CONFIRMED CRACK FREE AREA REF NTM 51-00-02-250-801 AND 51-00-01-250-801. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRISDR QXEA2012010301459Frame · corrodedFRAME 281 FLANGES ARE CORRODED STR 32S TO 29S. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .039", CONFIRMED CRACK FREE AREA REF NTM 51-00-02-250-801 AND 51-00-01-250-801. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344, ARE STORED SUSDR USAA2012011700005Frame · crackedQ6 CHECK - CRACK ON FRAME INNER CHORD AT BS 639, S17R. REPAIRED FRAME INNER CHORD AT BS 639, S17R IAW TYPICAL REPAIR TR737-5362-10-0098A AND EA103537, EA103558.SDR CHQA201200005Frame · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE RIGHT FRAME 23, JUST UNDER SILL NUMBER 1. THE RIGHT FRAME 23, JUST UNDER SILL NUMBER 1, WAS REPAIRED IN ACCORDANCE WITH ETD 2011-145-109968 AND SRM 53-00-04.SDR USAA2011122800002Structure · crackedFPBH & CDFI DROP IN - CRACK ON INNER CHORD AT BS 616, S16R, WL 208, RBL 45.5. REPLACED INNER CHORD AT BS 616, S16R, WL 208, RBL 45.5 IAW B737-400 SRM 51-40-02.
Back to JASC 5311