JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA201010010128Strap · crackedRT FAIL-SAFE STRAP CRACKED AND CORRODED AT LWR FASTENER COMMON TO STRAP AND FITTING. REPAIRED RIGHT FAIL-SAFE STRAP IAW REA B653-58935-SB & REA B653-58851-MR.SDR ABXA201010010127Strap · corrodedLT FAIL-SAFE STRAP BLEEDING CORR OUTBOARD SIDE STA 955 BETWEEN SIDE LOAD FITTING AND AT UPPER BOLT AROUND BUSHING COMMON TO STRAP AND FITTING. LT FAIL-SAFE STRAP WAS REPAIRED ON REA B653-58932-MR AND B654-58937-SB. CORROSION FOUND. PERFORMED PREVENTATIVE RESDR QXEA2010092700562Frame · corrodedC-CHECK - FRAME AT STA 94.800 LOWER ATTACH FLANGE BETWEEN STR 31 AND 32R HAS MINOR CORROSION. REMOVED CORROSION REF SRM 51-21-00, REMOVED 5 RIVETS TO FOM REF 51-40-07. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .039 REF HORIZON NTM 4.2.0-1. REMOVED FRAME SDR QXEA2010092700554Frame · corrodedC-CHECK - FRAME AT STA 301.000 LOWER ATTACH FLANGES BETWEEN STR 31L AND 31R HAVE MINOR CORROSION. REMOVED CORROSION FROM FLANGES IAW SRM 51-21-00. REMOVED RIVETS TO FOM IAW SRM 51-40-07. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .044" REF HORIZON NTM 4.2SDR FDEA201009233695Frame · damagedRT APU ACESS DOOR AT STA 1894.6 HAS A FRAME INSTALLATION AT BS 1894.6 THAT HAS EXISTING DAMAGE AND ELONGATED HOLES. DOOR FRAME OF RT APU ACCESS DOOR AT STA 1894.6 REPAIRED IAW EA F-5240-142334. (RT APU DOOR FRAME ELONGATED HOLES REPAIR). REPAIR IS CLASSIFIESDR USAA2010100892230Frame · corrodedSAL - C22 - MAJOR REPAIR - CORROSION ON FUSELAGE FRAME AT BS 967 BETWEEN S26R TO S27R. REPAIRED FUSELAGE FRAME AT BS 967 BETWEEN S26R TO S27R IAW B737 SRM 53-00-07 REPAIR 10.SDR FDEA201009223648Frame Splice · crackedUPPER CABIN, LONGERON 27L, FRAME SPLICE 1996L HAS COOROSION AND CRACKS THROUGH FASTENERS. CLEANED AREA AT FRAME SPLICE STA. 1996 AND LONGERON 27L IAW AMM 12-22-02-7. PERFORMED HFEC INSPECTION IAW NTSM 06-10-01. NO CORROSION OR CRACKS FOUND. NO REQUIREMENT FSDR AALA20100922TUL07Frame · crackedAFT ACCY STATION 1510 RIGHT LOWER FRAME CRACKED AT ALIGNMENT PIN. INSTALLED NEW SECTION OF FRAME AND DOUBLER PER SRM 53-01 FIGURE 2.SDR USAA2010092792119Frame · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON FUSELAGE FRAME AT FORWARD SERVICE DOOR CUTOUT AT FR16, S23R. REPAIRED FUSELAGE FRAME AT FORWARD SERVICE DOOR CUTOUT AT FR16, S23R IAW EA 133071.SDR USAA2010092792118Frame · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON FUSELAGE FRAME AT FORWARD SERVICE DOOR CUTOUT AT FR20, S23R. REPAIRED FUSELAGE FRAME AT FORWARD SERVICE DOOR CUTOUT AT FR20, S23R IAW EA 133071.SDR SWAA105682Frame · crackedDURING SCHEDULED 12Y CHECK, FOUND FRAME CRACKED AT BS 292, STR 17R. REPAIRED FRAME PER SRM.SDR SWAA105672Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 380, STR 8L. REPAIRED FRAME PER EA.SDR SWAA105671Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 663, STR 3L. REPAIRED FRAME PER EA.SDR SWAA105663Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 767, BETWEEN STR 25L TO STR 26L. REPAIRED FRAME PER EO.SDR SWAA105660Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 344, BETWEEN STR 24L TO STR 23L. REPAIRED FRAME PER EO.SDR SWAA105656Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 500C, STR 26L. REPAIRED FRAME PER EO.SDR SWAA105655Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 639, STR 10R. REPAIRED FRAME PER EO.SDR SWAA105645Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 500D, BETWEEN STR 26L TO STR 27L. REPAIRED FRAME PER SRM.SDR SWAA105644Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 500D, BETWEEN STR 27R TO STR 28R. REPAIRED FRAME PER SRM AND BAC DWG.SDR SWAA105643Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 500C, BETWEEN STR 26L TO STR 27L. REPAIRED FRAME PER SRM.SDR SWAA105642Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 500A, BETWEEN STR 28L TO STR 28R. REPAIRED FRAME PER SRM.SDR SWAA105641Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 520, BETWEEN STR 20L TO STR 21L. REPAIRED FRAME PER SRM.SDR USAA2010101292260Frame · crackedCLT - Q6 - MAJOR REPAIR - CRACK IN DOUBLER ON WEB OF FUSELAGE FRAME AT BS 303.9, S16L. REPLACED DOUBLER ON WEB OF FUSELAGE FRAME AT BS 303.9, S16L IAW B737 SRM 51-10-02.SDR USAA2010093092160Frame · crackedCLT - Q6 - MAJOR REPAIR - CRACK ON FUSELAGE FRAME AT BS 500 AT S24R. REPAIRED FUSELAGE FRAME AT BS 500 AT S24R IAW EA 102174.SDR ASOA201001420Frame · corrodedFS 605 FRAME CORRODED FWD & AFT SIDE AT STR 26L - 26R. THIS MWC IS A CONTINUATION OF MWC CO 7327210. REPAIRED IAW SRM 51-42-06 AND 51-42-21.SDR FDEA201009203590Frame · corrodedFWD CARGO COMPT. - FRAME WEB FOUND CORROSION AT STR49R-50R , FR37 BLENDED OUT CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.055" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA6-5310-141626 FLAP SDR FDEA201009203589Frame · corrodedAVIONICS COMPT- FRAME 17, STRINGER 45L-44L FRAME LOWER FLANGE FOUND CORROSION BLENDED OUT, CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.195" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-531SDR FDEA201009203587Frame · corrodedAVIONICS COMPT- FRAME 15 STRINGER 45L-44L FRAME LWR FLANGE FOUND CORROSION BLENDED OUT CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.078" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA6-5310-141SDR FDEA201009203586Frame · corrodedAVIONICS COMPT - FRAME 15, S44L-37L FRAME BOTTOM FLANGE FOUND CORROSION BLENDED OUT, CORROSION IAW SRM 51-74-10 REMAINING THINKNESS IS 0.048" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310-14161SDR FDEA201009203585Frame · corrodedAVIONICS COMPT-FRAME 14, S41-37L FRAME BOTTOM FLANGE FOUND CORROSION BLENDED OUT, CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.046" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA6-5310-141616 SDR SWAA105640Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 400, STR 8L. REPAIRED FRAME PER EA.SDR SWAA105624Frame · crackedDURING SCHEDULED SPV CHECK, FOUND FRAME CRACKED AT BS 500B, BETWEEN 20L TO STR 21L. REPAIRED FRAME PER SRM.SDR SWAA105621Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 663, STR 3L. REPAIRED FRAME PER ER AND EA.SDR SWAA105620Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 663, BETWEEN STR 2R TO STR 3R. REPAIRED FRAME PER ER AND EA.SDR SWAA105617Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME WEB CRACKED AT BS 639, LBL 66. REPAIRED FRAME PER ER AND EA.SDR SWAA105616Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME WEB CRACKED AT BS 639, RBL 66. REPAIRED FRAME PER ER AND EA.SDR AALA20100920TUL15Frame · crackedCRACKED FRAME AT STATION 1418 AND LONGERON 2 LEFT. INSTALLED DOUBLER PER AARD 5310-00-15 AND SRM 51-30-05.SDR AALA20100920TUL09Frame · crackedFRAME CRACKED AFT SIDE 1418 LONGERON 2 RIGHT. INSTALLED REPAIR ANGLE DOUBLER PER AARD 53-10-00-15.SDR FDEA201009203571Frame · corrodedMAIN CARGO COMPARTMENT BULKHEAD UPPER CHORD HAS CORROSION BS 324 ENTIRE LENGTH. REMOVED CORROSION UPPER CHORD IAW SRM 51-10-02 . BLENDED AREA L= 44" W=3.0 " D=.039, ORIG MAT .125 REMAINING . 086 OUT OF LIMITS IAW SRM 53-10-08, FIG 101, DET 9. R & R UPPESDR FDEA201009203558Frame · corrodedAVIONICS COMPT - FRAME 16A, STRINGER 45L-44L FRAME LWR FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10 REMAINING THINKNESS IS 0.089" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310-1SDR FDEA201009203557Frame · corrodedAVIONICS COMPT - FRAME 16, STRINGER 45L-44L FRAME LWR FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10, REMAINING THINKNESS IS 0.085" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310SDR FDEA201009203556Frame · corrodedAVIONICS COMPT - FRAME 15A STRINGER 45L-44L FRAME LWR FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.107" IAW NTM 51-10-04. NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310SDR FDEA201009203555Frame · corrodedAV COMPT - FRAME 14, STRINGER 45L-44L FRAME LWR FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10 REMAINING THINKNESS IS 0.065" IAW NTM 51-10-04. NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310-141616SDR FDEA201009203554Frame · corrodedAVIONICS COMPT - FRAME 14A, STRINGER 45L-44L FRAME LWR FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10 REMAINING THINKNESS IS 0.092" IAW NTM 51-10-04. NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310-SDR FDEA201009203553Frame · corrodedAVIONICS COMPT - FRAME 13A, STRINGER 45L-44L, FRAME LWR FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.107" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-531SDR FDEA201009203551Frame · corrodedAVIONICS COMPT - FRAME 13, STINGER 44L-45L FRAME LOWER FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.048" IAW NTM 51-10-04. NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-531SDR FDEA201009203549Frame · corrodedAVIONICS COMPT - FR12A, S45-44L FRAME LOWER FLANGE FOUND CORROSION. BLEND OUT CORROSION IAW SRM 51-74-10. REMAINING THINKNESS IS 0.112" IAW NTM 51-10-04 NO CRACK FOUND IAW NTM 51-10-18 AND NTM 51-10-08 WITHIN ALLOWABLE DAMAGE LIMIT IAW EA 6-5310-141616. RSDR GLBA20100920FFrame · crackedMAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSP MX FOUND A CRACK IN THE FRAME AT THE STRINGER CUTOUT 4R AT FS 288, .4" IN LENGTH. MX REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO10-1900-53-056. MATERIALS UTILIZED ARE INCLUDED INSDR KCSA101126Doubler · crackedBS 400 FUSELAGE FRAME DOUBLER CRACKED AT STR 15L.SDR USAA2010100792212Frame · corrodedMCN - C4 - MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FUSELAGE FRAME AT BS 922, LBL 50. REPAIRED FUSELAGE FRAME AT BS 922, LBL 50 IAW B757 SRM 51-70-12.
Back to JASC 5311