JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GAIA03150STFrame · dentedDURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED IN RADIUS BS 700 ABOVE STR 17 RT. REF FASI N/R NR 61833, CUTOUT DAMAGE AND INSTALLED REPAIR DOUBLER 8 INCH BY 5.5 INCH PER B727 SRM 51-40-3 FIG 3. (M)SDR GAIA03137STFrame · crackedDURING C-CHECK INSPECTION FOUND FUSELAGE FRAME CRACKED BS 480 LEFT SIDE IN AREA OF SILL BEAM. REF FASI N/R NR 61678, CUT OUT DAMAGE AND INSTALLED REPAIR PER B727 SRM 53-10-4 FIG 11. (M)SDR GAIA03149STFrame · dentedDURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED IN RADIUS BS 680 ABOVE STRINGER 17 RT. REF FASI N/R NR 61832, CUT OUT DAMAGE 1 INCH BY 1 INCH AND INSTALLED REPAIR DOUBLER 8 INCH BY 6 INCH PER B727 SRM 51-40-3 FIG 1. (M)SDR GAIA03147STFrame · dentedDURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED BS 500 ABOVE STRINGER 17 RT. REF FASI N/R NR 61829, CUT OUT DAMAGE AND INSTALLED 9 INCH BY 6 INCH REPAIR DOUBLER PER B727 SRM 51-40-3 FIG 1. (M)SDR EIA2003152Frame · damagedNOSE SECTION STR 40 AND 41 FS 330 RT REMOVED TO FOM STA 340 FRAME REWORK. FABBED AND INSTALLED STR 40 AND 41 REPAIR AT STA. 330-340 RT IAW SRM 53-10-03 FIG 3 AND 51-30-02.SDR GAIA03136STFrame · crackedDURING C-CHECK INSPECTION FOUND C-2 DOOR CUTOUT AFT FRAME BS 990 INNER CHORD IS CRACKED AND CORRODED AT STR 27 RT. REF FASI N/R NR 61484, CUT OUT DAMAGE AND INSTALLED ANGLE REPAIR PER B727 SRM 51-40-4 FIG 3. (M)SDR GAIA03122STFrame · crackedDURING C-CHECK INSPECTION FOUND AMIN CABIN FRAME DENTED BS 520 AT STRINGER 17 RT. REF FASI N/R NR 61416, CUT OUT DAMAGE 2.5 INCH BY 1.5 INCH INSTALLED DOUBLER REPAIR PER SRM 51-40-3 FIG 1. (M)SDR SWAA032349Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE STUB FRAME CRACKED AT BS 294, WL 208, RBL 53. REPAIRED FRAME PER ER.SDR GAIA03123STFrame · dentedDURING C-CHECK INSPECTION FOUND CABIN FRAME DENTED BS 540 STRINGER 17 RT. REF FASI N/R NR 61417, CUT OUT DAMAGE, INSTALLED DOUBLER REPAIR 8 INCH BY 5 INCH PER B727 SRM 51-40-3 FIG 1. (M)SDR USAA030216Frame · crackedFOUND FRAME CRACKED .75 INCH, STATION 360 1 INCH BELOW STRINGER 14R CLIP. REPAIRED PER SRM 53-00-07. (M)SDR UPS03841525Frame · crackedINSPECTION TYPE: C2, FRAME CRACKED ACROSS UPPER FLANGE AT STATION 1440 AT LONG 25R. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW EO DC8-5310-11728.SDR MWEA030428Frame · crackedCRACK AT FUSELAGE FRAME STATION 718 LEFT OUTBOARD FORWARD FLANGE HAS GROWN FROM 6 INCHES TO 7.6250. -- INSTALLED DOUBLER.SDR AT0700051Frame · damagedA/C STRUCK BY CATERING TRUCK UNDERNEATH GALLEY SERVICE DOOR. FORMERS AT STA 200 DAMAGED. FABRICATED REPLACEMENT SECTION OF FORMERS STATION 200, MATERIAL 7075 T6 INSTALLED PER B717-SRM 53-00-06 FIG 2.SDR AT0700050Frame · damagedA/C STRUCK BY CATERING TRUCK UNDERNEATH GALLEY SERVICE DOOR. FORMERS AT STA 180 DAMAGED. FABRICATED REPLACEMENT SECTION OF FORMERS STATION 180, MATERIAL 7075 T6 INSTALLED PER B717-SRM 53-00-06 FIG 2.SDR GAIA03113SPFrame · dentedDURING B-CHECK AT DFW, A FUSELAGE FRAME AT BS 560 WAS FOUND DENTED BY STRINGER 17R. THE FRAME WAS REPAIRED PER THE B727 SRM. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR AUS20031088Frame · cracked(AUS) CABIN BELT FRAME CRACKED. FOUND DURING INSPECTION IAW SERVICE LETTER CC7-SL-036.SDR DHL2003807537Frame · crackedFWD ACCESSORY COMPT FRAME 1.000 CRACK AT STA 55.000 L-24L. PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 2. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. TRIMMED OUT FRAME CRACKED SEGMENT AND FABRICATED NEW FRAME SEGMENT AND 2EA SPLICE ANGLES (ALCLAD 7075-0 0.071) IASDR DHL2003807538Frame · crackedFWD ACCESSORY COMPT FRAME CRACK 1.000 STA 55.000 L-24R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 2. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. TRIMMED OUT FRAME CRACKED SEGMENT AND FABRICATED NEW FRAME SEGMENT AND 2EA SPLICE ANGLES IAW SRM 53-2SDR EIA2003158Frame · corrodedUPPER DECK STA. 520 STR 1 LT HAS CORROSION NEAR LAP SEAM. REMOVED DAMAGED, FABBED AND INSTALLED NEW REPAIR IAW SRM 51-10-02, 53-30-03 AND 51-30-02.SDR 03FDEA01057Frame · corrodedNR 174 CORROSION (C53-132-02) BS 870, LWR CHORD LBL 12-16, WL 148. R/R CHORD.SDR SWAA032310Frame · corrodedDURING SCHEDULED 1/4D CHECK, FOUND FUSELAGE FRAME CORRODED AT BS 727 LBL 7 TO RBL 3. REPAIRED FRAME PER SRM AND ERO.SDR SWAA032290Frame · corrodedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CORRODED AT BS 1006, WL 195 AT LBL 29-33 AND WL 196 AT RBL 30. REPAIRED FRAME PER SRM.SDR SWAA032288Frame · corrodedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CORRODED AT BS 380, LBL 20. REPAIRED FRAME PER SRM.SDR UPS03841606Frame · corrodedINSPECTION TYPE: C3, AFT PIT FS 1020 CORROSION UNDER NUTPLATES ON LOWER SURFACE OF UPPER FRAME FLANGE FROM L36-L34R. REMOVED CORROSION IAW DC8 SRM 51-1-8. ORIG .080, REMOVED .060 REMAIN .020 FOUND OUT OF LIMITS IAW DC8 SRM 53-2-0. FRAME CAP OUT OF LIMITS IAWSDR EIA2003160Frame · crackedLARGE CRACKS IN RT FS 340 FRAME WEB BETWEEN STR. 24 THRU 26. REMOVED DAMAGED, NDT AREA, FABBED AND INSTALLED REPAIR IAW ECRA 479-53-183-2.SDR SWAA032277Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 500, WL 154 AND RBL 1.5. REPAIRED FRAME PER SRM.SDR SWAA032275Frame · corrodedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CORRODED AT BS 807, BL 0. REPAIRED FRAME PER SRM.SDR SWAA032274Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 188, WL 207 AND LBL 30. REMOVED AND REPLACED FRAME PER SRM.SDR ASAA0380672Frame · chafedOKC - DURING 30K CHECK, FOUND EDGE OF FRAME CHAFED. REPAIRED FRAME. (M)SDR ASAA0380665Frame · gougedOKC - DURING 30K CHECK, FOUND FRAME 522 ABOVE LONGERON 6L GOUGED AND CRACKED. REPAIRED PER SRM. (M)SDR ASAA0380653Frame · corrodedOKC - DURING 30K CHECK, FOUND CORROSION ON FRAME 1060. REPLACED FRAME CAP. (M)SDR ASAA0380640Frame · crackedOKC - DURING 15K CHECK, FRAME IS CRACKED IN AFT CARGO BAY AT FS 1231. REPLACED DAMAGED SECTION AND SPLICED IN NEW SECTION PER SRM 53-05. (M)SDR UPS03841603Frame · corrodedINSPECTION TYPE: C3, FWD PIT STA 280 TORQUE BOX HAS AREA OF LIGHT CORROSION. ACCOMPLISHED REPAIR IAW REO G09550 REV A.SDR SWIA200312581Frame · crackedLEFT FRAME 9 CLIP UNDER DV WINDOW CRACKED. DISCOVERED DURING C-CHECK. REPAIRED FRAME 9 LEFT SIDE PER SERVICE BULLETIN 120-53-0073 REV 00 DATED 21 JUL 99.SDR SWIA200312580Frame · crackedRIGHT FRAME 9 CLIP UNDER DV WINDOW CRACKED. DISCOVERED DURING C-CHECK. REPAIRED FRAME 9 RIGHT SIDE PER SERVICE BULLETIN 120-53-007 REV 00 DATED 21 JUL 99.SDR ABXA030414Frame · crackedFRAME CRACKED AT FS 1076 AND LONGERON 19 LEFT. REPAIRED FRAME AT FS 1076 IAW DC-9 SRM 53-03.SDR SWAA032261Frame · crackedDURING SCHEDULED 1/4D CHECK, FOUND 2 EA CRACKS AT FUSELAGE FRAME, BS 440 WL 208. REPAIRED FRAME PER SWA EA.SDR 2003UALA00775Frame · dentedFORWARD PIT FRAME STA 740 APPROX. RBL 51 HAS DENT IN THE HORIZONTAL FLANGE OF THE CHORD. MAJOR REPAIR ACCOMPLISHED. INSTALLED NESTED ANGLE REPAIR.SDR MWEA030419Skin · corrodedAFT GALLEY DOOR JAMB, FORWARD SIDE, INNER LAYER OF SKIN IS EXFOLIATED BETWEEN LONGERON 16 LEFT AND 17 LEFT. FABRICATED AND INSTALLED REPAIR AND FILLER.SDR AUS20031235Frame · fractured(AUS) FORWARD FUSELAGE FRAME AND SUPPORTING CROSS BEAM FRACTURED. NOSE LANDING GEAR AFT ATTACHMENT FITTING IS ATTACHED TO THE FRAME.SDR MALA030459Frame · chafedDURING 4Y-2Y INSPECTION IN CWA, RT CARGO FRAME STA 658.5, 11.5 INCHES ABOVE SL 1620 CHAFE. MAINTENANCE REPAIRED DAMAGE IAW EO S53152 INSTALLATION OF DOUBLER.SDR SWAA032237Frame · crackedDURING SCHEDULED D CHECK, FOUND RT FUSELAGE FRAME CRACKED AT BS 188, WL 207, RBL 30. REMOVED AND REPLACED FRAME ASSY PER SRM.SDR QXEA200301287Frame · chafedPDX- AFT BAGGAGE COMPARTMENT AFT FRAME 653.349 CHAFED AT FLOOR LEVEL AT OUTBOARD SIDE. REPAIRED IAW DHC-8 SRM 51-20-11 AND SRM 51-20-36.SDR CALA0300598Beltframe · corrodedFBB BELTFRAME AT STATION 500D HAS CORROSION OUTBOARD OF STRINGER S27L. INSTALLED REPAIR FBB BELTFRAME AT STATION 500D.SDR MALA030458Frame · corrodedDURING 4Y/2Y INSPECTION IN CWA, FRAME TOP AT STA 272 HAS CORROSION RT OF BL0. MAINTENANCE COMPLETED REPAIR IAW EO NR 53102. A/C RELEASE DATE 10/12/2003. REFER 409 NR 195719 FOR DETAIL.SDR MALA030457Frame · corrodedDURING 4Y/2Y INSPECTION IN CWA, FOUND FRAME AT STA 225 CORRODED. COMPLETED REPAIR IAW EO NR 53182. A/C RELEASE DATE 10/12/2003. REF 409 NR 195723 FOR ADDITIONAL DETAIL.SDR COMA0360451Doubler · cracked718 FRAME DOUBLER CRACKED, COMPLIED WITH EO 53-077, IAW MAJOR WORK ORDER NR 71396.SDR MALA030456Frame · corrodedDURING 4Y/2Y INSPECTION IN CWA, CORROSION FOUND ON FRAME 294 RBL 24, BLENDED OUT DAMAGE, FABRICATED DOUBLER IAW EO NR 53102. A/C RELEASE DATE 10/12/2003. REFER LOG PAGE 195763 FOR DETAIL.SDR COMA0360452Doubler · crackedFRAME 718 DOUBLER CRACKED. COMPLIED WITH EO 53-027, PER MAJOR WORK ORDER 71396.SDR AWXA200301473Frame · crackedLCQ - MAJOR REPAIR - DURING C-14 CHECK 2 EACH CRACKS WERE FOUND IN FASTENER HOLES ON THE RT FUSELAGE FRAME AT BS 727, BETWEEN WL 195 AND WL 202. MAINTENANCE OVERSIZED HOLES AND PERFORMED HFEC INSPECTION TO VERIFY CRACKS CONTAINED, NO CRACK INDICATIONS WERE NO
Back to JASC 5311