SDR ASAA2016011614992Stringer · crackedUPON REMOVAL OF TRANSITION PANEL FOUND STR CLIP AT BS 500F, STR 26R TO BE CRACKED. ACFT GROUNDED. R & R STR CLIP IAW SRM 51-40-02-0G-0.SDR DALA2016011900504Stringer · corrodedCORROSION ON STRINGER 42L BETWEEN FRAMES 56 AND 57. REMOVED STR 42L BETWEEN FRAMES 55 AND 58. FABRICATED AND INSTALLED STRINGER SECTION AND COUPLING/SPLICE IAW SRM 53-00-13.SDR DALA2016011900483Stringer · corrodedFOUND CORROSION ON STRINGER 43L BETWEEN FRAMES 56 AND 57. REMOVED STR 43L BETWEEN FRAME 55 TO 59. INSTALLED NEW STRINGER SECTION IAW SRM 53-00-13.SDR DALA2016011700413Longeron · crackedCRACKED LONGERON 5L WITH FRAME BS 1437. LONGERON REPAIRED IAW SRM 53-02, FIG 18.SDR SWIA201641840Stringer · corrodedCORROSION FOUND ON STR 27 BETWEEN FS 280.00 AND FS 300.00. R & R STR 27, PN: SH670-31642-1 IAW SRM. LEAK CHECK GOOD.SDR SWAA2016021649146Stringer Splice · corrodedSTRINGER SPLICE CORRODED AT BS 908, STRINGER 22R. R & R SPLICE IAW SRM & DWG.SDR SWAA2016021148976Stringer Splice · corrodedSTRINGER SPLICE CORRODED AT BS 847, STRINGER 21R. R & R SPLICE IAW SRM & DWG.SDR SWAA2016021148975Stringer Splice · corrodedSTRINGER SPLICE CORRODED AT BS 847, STRINGER 22R. R & R SPLICE IAW SRM & DWG.SDR SWAA2016021148974Stringer Splice · corrodedAFT CARGO COMPARTMENT, STRINGER SPLICE CORRODED AT BS 847, STRINGER 23R. R & R SPLICE IAW SRM & DWG.SDR SWAA2016021048910Stringer Splice · corrodedSTRINGER SPLICE CORRODED AT BS 847, STRINGER 24R. R & R SPLICE IAW SRM & DWG.SDR YENA20160114027Stringer · corrodedSTRINGER 29R HAS AREA OF CORROSION TWELVE INCHES AFT OF FRAME 76. REPAIRED IAW TASK CARD NR E16-007-01.SDR YENA20160114026Stringer · corrodedSTRINGER 29R HAS AREA OF CORROSION TEN INCHES AFT OF FRAME 76. COMPLIED WITH TASK CARD NR E16-007-01.SDR YENA20160114025Stringer · corrodedSTRINGER 29R HAS AREA OF CORROSION EIGHT AND A HALF INCHES AFT OF FRAME 76. REPAIRED IAW TASK CARD NR E16-007-01.SDR YENA20160114024Stringer · corrodedSTRINGER 29R HAS AREA OF CORROSION SIX INCHES AFT OF FRAME 76. COMPLIED WITH TASK CARD NR E16-007-01SDR YENA20160114023Stringer · corrodedSTRINGER 29R HAS CORROSION FOUR INCHES AFT OF FRAME 76, REPAIRED IAW TASK CARD E16-007-01SDR DALA2016011500362Longeron · crackedCRACK LONGERON 11R WITH FRAME, BS 1380. CARD 07, ZONE 61. LONGERON WAS REPLACED IAW SRM 51-30-2, 53-14-4, 51-30-5, 51-10-4 AND 51-10-3, PAR 14 AND 21.SDR DALA2016011400309Stringer · corrodedCORROSION ON 43L BETWEEN FRAMES 56 AND 57 IAW 53-00-13, FABRICATED STR SPLICE ER/A 542941-14AD, REV 0, 1, 2, 3.SDR DALA2016011400308Stringer · corrodedCORROSION ON STR 42L BETWEEN FRAMES 56 AND 57, REMOVED STR 42L BETWEEN STA 55 AND 58 IAW 53-00-13, REF PRI /ER/A 542941-14AD, REV 0, 1, 2, 3.SDR DALA2016011400302Longeron · crackedCRACKED LONGERON 13L BS 1437. THE LONGERON WAS REPLACED IAW SRM 53-14-4 AND 51-30-2 AND 51-30-5.SDR DALA2016020100804Stringer · corrodedCORROSION FOUND ON STRINGER 28R, BS 1600. REPAIRED IAW ER/A 52229 2-14. REPAIR APPROVAL LIMITED TO 12 MONTHS VALIDITY. DTE REQUIRED WIT HIN 12 MONTHS. DEFER TO M-CHECK VISIT FEB 2016. GVI WAS ACCOMPLISHED WITH NO DISCREPANCIES FOUND. OK TO MAINTENANCE FESDR SWIA201641839Stringer · corrodedCORROSION ON STR JOINT PIECE AT FS 333 COMMON TO STR 26L. R & R STR JOINT PIECE AT FS 333.00 STR 26L IAW SRM. PRESSURIZED THE ACFT AND CHECKED FOR LEAKS IN THE REPAIR AREA IAW AMM. NO LEAKS NOTED.SDR SWIA201641838Stringer · corrodedCORROSION FOUND ON STR 27 BETWEEN FS 333 AND FS 350. R & R STR 27 BETWEEN FS 333.00 TO FS 350.00 IAW SRM. LEAK CHECK GOOD.SDR SWIA201641837Stringer · corrodedCORROSION FOUND ON STR 27 BETWEEN FS 305 AND FS 333. R & R NEW STR 27 BETWEEN FS 305.00 AND FS 333.00 IAW SRM. PRESSURIZED THE ACFT AND CHECKED FOR LEAKS IN THE REPAIR AREA IAW AMM. NO LEAKS NOTED.SDR DALA2016011400301Longeron · crackedCRACK ON LONGERON 4 LT BS 541 AT CABIN STRUCTURE. LONGERON WAS REPAIRED IAW SRM 53-02, FIG 18, 51-30-2 AND 51-10-3 PAR 14, 21.SDR DALA2016011300246Longeron · corrodedAFT CARGO LONGERON 30 CORRODED AT BS 954. BLENDED CORROSION ON LONGERON 30 AT BS 954 ORIGINAL MATERIAL THICKNESS .125, .063 REMAINING AT DEEPEST POINT. INSTALLED REPAIR IAW SRM 53-00-05, REPAIR 3. WIP: BLENDED CORROSION ON LONGERON 30 AT BS 954 ORIGINAL MATESDR FDEA201601120115Stringer · corrodedAV COMPARTMENT BELOW RT FLOOR FUSELAGE INTERNAL STRUCTURE, BETWEEN FRAME 11 & 11A, FOUND CORROSION ON BOTTOM STRINGER. COMPLIED WITH EA 6-5310-T0323047 P 1. REPLACED NLG BULKHEAD, RT SIDE LATERAL KEEL BEAM AT FRAME 11 - 11A. MAJOR REPAIR IAW GMM 6-2-100.SDR SWIA201641835Stringer · corrodedSTRINGER 26R HAS CORROSION AROUND FASTENERS BETWEEN FS 333 AND FS 364. R & R NEW STR 26R BETWEEN FS 333.00 AND FS 364.00 IAW SRM. PRESSURIZED THE ACFT AND CHECKED FOR LEAKS IN THE REPAIR AREA IAW AMM. NO LEAKS NOTED.SDR ASAA2016011114895Stringer · crackedSTRINGER ANGLE FORWARD OF R1 DOOR WL 247. ACFT GROUNDED. R & R CRACKED ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA2016011114894Stringer · crackedSTRINGER ANGLE FORWARD OF R/1 DOOR WL 239. ACFT GROUNDED. R & R CRACKED ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA2016011114893Stringer · crackedSTRINGER ANGLE FORWARD OR R1 DOOR WL 253. ACFT GROUNDED. R & R CRACKED ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA2016011114892Stringer · crackedSTRINGER ANGLE FORWARD OF R1 DOOR. ACFT GROUNDED. R & R CRACKED ANGLE IAW SRM 51-40-02-0G-0.SDR DALA2016011200260Stringer Splice · corrodedCORROSION ON STR 43L SPLICE REPAIR COUPLING BETWEEN FRAMES 56 AND 57. REPLACED STR 43L SPLICE IAW SRM 53-00-13, FIG 201.SDR DALA2016011200259Stringer · corrodedCORROSION ON STR 42L BETWEEN FRAMES 56 AND 57. REPLACED STR SPLICE 42L IAW SRM 53-00-13, FIG 201.SDR DALA2016011200201Longeron · crackedCRACKED LONGERON NR 16, LT BS Y=1437. LONGERON 16 LT WAS REPLACED IAW SRM 53-14-4, FIG 4.SDR ASAA2016011015362Stringer · corrodedSTR 21R IS CORRODED STA 980-990. ACFT GROUNDED. REMOVED DAMAGE, FOUND TO BE OUT OF LIMITS REMOVED DAMAGE STRINGER AND REPLACED WITH NEW STRINGER IAW SRM 51-10-02-0G-0 PAR 14, SRM 53-00-03-1A-1, AND SRM 51-40-02-0G-0.SDR DALA2016011100175Stringer · corrodedCORROSION ON STR 43L BETWEEN FRAMES 56 AND 57, STRINGER SPLICE REPAIR FWD OF FRAME 56 AND AFT OF FRAME 57 ON S-43L IAW SRM 53-00-13, FIG 201 AND PRI 542888-14, REV 0.SDR SWIA201641833Longeron · corrodedLEFT LONGERON BETWEEN FS 333 AND FS 364 HAS CORROSION AROUND FASTENERS. R & R NEW SERVICEABLE LT LONGERON 25L IAW SRM.SDR DALA2016011400269Stringer Splice · corrodedBS 958-974 S30 SPLICE IS CORRODED. MARKED, REF ORNRC 63165-0100-0037, REPLACED SPLICE IAW SRM 51-41-05.SDR FDEA201601080090Stringer · dentedSTATION 430, STRINGER 18R, AFTER REMOVAL OF SKIN REPAIR, FOUND STRINGER DENTED. EVALUATED DENT IN STRINGER, FOUND NO ALLOWABLE DAMAGE FOR S/F ACFT. R & R STRINGER, STATION 395 - 439, STRINGER 18R IAW SRM 51-40-02. CAT A MAJOR REPAIR.SDR DALA2016091606675Stringer · damagedPERFORMED PERMANENT REPAIR ON STRINGER 43L BTW FR 55 TO FR56 IN AFT CARGO COMPARTMENT AS PER SRM 53-00-13 FIGURE 201, ER/A 542785-14AD REV. ORIGINAL, AND ER/A 549949-14 REV.A,SDR SWIA201641830Stringer Splice · corrodedCORROSION ON STRINER SPLICE 25R AT BS 333. R & R IAW SRM.SDR SWIA201641829Stringer Splice · corrodedCORROSION ON STRINGER SPLICE 25R AT BS 333 COMMON TO STR 26R. INSTALLED STRINGER SPLICE IAW SRM.SDR SWIA201641828Stringer · corrodedCORROSION ON STRINGER 25L JOINT PIECE AT FS 333. R & R S IAW SRM. PRESSURE CHECKED GOOD.SDR SWIA201641819Stringer · corrodedSTRINGER 26L HAS CORROSION AROUND FASTENER BETWEEN FS 333 AND FS 364. R & R STR 26L BETWEEN FS 333.00 AND FS 364.00 IAW SRM. NO PRESSURE LEAKS NOTED.SDR DALA2016011400270Stringer Splice · corrodedBS 927- 946, S30 & SPLICE IS CORRODED. REPLACED THE STRINGER SPLICE IAW SRM 51-41-05.SDR DALA2016010800117Stringer · corrodedFOUND CORROSION ON STRINGERS 43L AND 42L BETWEEN BS 56 AND BS 57, REMOVED CORROSION FROM STRINGERS 42L AND 43L BETWEEN FRAMES 56 AND 57 IAW SRM 51-73-00, 917648. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-21-13 COMPLIED WITH ERA 542785-14.SDR DALA2016010700060Longeron · crackedCRACK AT LONGERON 5LT BS 207. DAMAGE LONGERON WAS REMOVED IAW SRM 51-30-2, NEW LONGERON WAS ADJUSTED AND DRILLER IAW SRM 51-10-4, NEW LONGERON WAS TREATED AND PAINTED IAW SRM 51-10-3, P 14, 21 AND NEW LONGERON WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.SDR SWIA201641825Longeron · corrodedRIGHT LONGERON 25R BETWEEN FS 333 TO FS 364 HAS CORROSION AROUND FASTENERS. R & R WITH NEW SERVICEABLE LONGERON IAW SRM.SDR SWIA201641822Stringer · corrodedSTRINGER 26R HAS CORROSION AROUND FASTENERS FROM BS 280 TO 333. R & R THE STRINGER IAW SRM.SDR SWIA201641821Stringer · corrodedSTRINGER 25L HAS CORROSION AROUND FASTENERS FROM FS 280 TO FS 333. R & R STRINGER IAW SRM. PRESSURE CHECK GOOD.
Back to JASC 5313