As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND ON STRINGER 28R, BS 1600. REPAIRED IAW ER/A 52229 2-14. REPAIR APPROVAL LIMITED TO 12 MONTHS VALIDITY. DTE REQUIRED WIT HIN 12 MONTHS. DEFER TO M-CHECK VISIT FEB 2016. GVI WAS ACCOMPLISHED WITH NO DISCREPANCIES FOUND. OK TO MAINTENANCE FERRY FLIGHT FOR M-CHECK. DTA AND SUBSEQUENT ER/A REVISION TO BE ACCOMPLISHED DURING M-CHECK VISIT.