JASC 5314
Service difficulty reports · 2,917
Reports filed under 5314 · Fuselage Main, Keel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5314' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5314' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202265885None · corrodedSTGR26L IS CORRODED MULTIPLE AREAS. FS953.00 €“ FS969.00. (MARKED) (C-CHECK RO 6/6/2022) INSTALLED NEW STRINGER SECTION REF. REO 670-53-00-690 REV. -- DATED 2022-05-09, AND DWG. SH670-37060 REV. G. LEAK CHECK GOOD AT THIS TIME. COMPLIED WITH 51-900-100SDR SWIA202265741None · corrodedAVIONICS BAY STRINGER 27 CORRODED, BETWEEN FS333.00 AND FS364.00. (C CHECK RO 5/23/22) REPLACED AVIONICS BAY STRINGER 27 BETWEEN FS333.00 TO FS364.00 REF DWG SH690-31350 REV. M, CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK SDR SWIA202265360None · noneDURING THE INSTALLATION OF ISPS EA ERJ3468-23 (STC ST04435AT), 1 HOLE WAS MIS-DRILLED ON STRINGER 20L BETWEEN FRAMES 30 AND 31 NEXT TO STRUCTURE BAY DRAIN HOLE ON STRINGER 20L. (FILED - CLOSED) COMPLIED WITH REPAIR OF STRINGER 20L BETWEEN FRAMES 30 AND 31SDR SWIA202265852None · crackedL/H SIDE FS 625 CLIP IS CRACKED AT STR 15L (C-CHECK RO 6/1/2022) REMOVED AND INSTALLED NEW FS625 STGR15L CLIP REF DWG 601-35012 REV-B, CRJ200 SRM 51-42-21 AND CRJ 200 SRM 51-42-06. RESTORED FINISH. COMPLIED WITH TASK CARD 51-900-1003-SKY. SEE CONTINUE CSDR SWAA2022042992074None · crackedCUSTOMER REQUEST-CRACK ON VAPOR BARRIER LWR LEFT WEB STA 663.75 LBL 48 2022-192849 / [01] TOOL USED CALIPER P/N 500-197-30; S/N A18234378; DUE DATE: 21-SEP-22.;[02] TOOL USED= HOT BONDER P/N: HCS9200B-AV; S/N: 18196119; DUE DATE: 24-FEB-23.;[03] TOOL USED= SCASDR DALA2022040602376None · noneSHIP 3171 - PROFILE IS CRACKED ON BELLY FAIRING SUPPORT STRUCTURE AT FR41 BETWEEN -Y254 TO -Y354. CORRECTIVE ACTION: REMOVED AND REPLACED PROFILE CAP ANGLE (2185025)SDR DALA2022040602375None · noneSHIP 3171 - R/H TI ANGLE @ FRAME 42 IN R/H BELLY HYDRAULIC BAY HAS CRACK. CORRECTIVE ACTION: WORK WAS PERFORMED ON WORK CARD 5353-01006-03(2184558)SDR SWIA202265739None · damagedREMOVE FRAME SEGMENT AT FS629 FROM STGR 20R TO STGR 16R TO FACILITATE STGRS 18R, 19R, 20R AND 21R REPLACEMENT, AFTER STRINGERS REPLACEMENT, REINSTALL FRAME SEGMENT BY SPLICE REPAIR. REF MHI 690-53-00-478, REV --(P1), DATED ON 2022-03-29 AND CAMPS MX TRANS #€™SDR SWIA202265597None · crackedR/H SIDE STR 14 FS 625 CLIP IS CRACKED. (C-CHECK RO 5/16/2022) REMOVED AND REPLACED FS625 CLIP AT STGR 14R REF. CRJ 200 SRM 51-42-06 AND DWG 601-35012 REV. D. / COMPLIED WITH TASK CARD 51-900-1003-SKYSDR SWIA202265596None · crackedL/H SIDE STR 14 FS 625 CLIP IS CRACKED. (C-CHECK RO 5/16/2022) REMOVED AND REPLACED FS625 CLIP AT STGR 14L REF. CRJ 200 SRM 51-42-06 AND DWG 601-35012 REV D. / COMPLIED WITH TASK CARD 51-900-1003-SKYSDR SWAA2022050494161Vapor Barrier · debondedCUSTOMER REQUEST DEBONDED EXISTING REPAIR ON VAPOR BARRIER LT AT BS663 2022-168583 / [01] TOOL USED: CALIPER P/N 500-464 S/N 15331926 DUE DATE 28-SEP-22.;[02] TOOL USED HOT BONDER P/N HCS9000B-AV S/N 14081912 DUE DATE 04-JUN-22;[03] TOOL USED SCALE P/N CL5000 SDR SWIA202265734None · corrodedSTRINGER JOINT SPLICE 22R CORRODED AT FS333. (C CHECK RO 5/23/22) INSTALLED NEW 22R STRINGER SPLICE AT FS333.00 IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG:SH670-32420 REV E. SEE CONTINUATION CARD FOR DETAILS. PRESSURE LEAK CHECK OF REPAIR AREA CHECKED GSDR SWIA202265733None · corrodedSTRINGER JOINT SPLICE 21R CORRODED AT FS333. (C CHECK RO 5/23/22) EVALUATED SPLICE AT STGR 21R, FS333.00 HAS PITTING CORROSION THROUGH PART. 100% MATERIAL LOSS. FOUND TO BE OUT OF LIMITS. REF. CRJ 900 SRM 53-00-00-101-001-A01. REMOVED AND REPLACED DAMAGESDR SWIA202265732None · corrodedSTRINGER JOINT SPLICE 27 CORRODED AT FS333. (C CHECK RO 5/23/22) JOINT SPLICE 27 FS333 FOUND TO BE OUT OF LIMITS REF. CRJ-900 SRM, 53-00-00-101-001-A01. REMOVED AND REPLACED STRINGER JOINT SPLICE 27 AT FS333 REF. CRJ-900 SRM, 51-42-06-001-001-A01 AND DWGSDR SWIA202265731None · corrodedSTRINGER JOINT SPLICE 26L CORRODED AT FS333. (C CHECK RO 5/23/22) INSTALLED NEW STRINGER JOINT SPLICE 26L AT FS333.00 IAW CRJ900 SRM 51-42-06-001-001-A01 AND DWG: SH670-32420 REV E. PRESSURE LEAK CHECK OF REPAIR AREA CHECKED GOOD, NO LEAKS NOTED REF. CRJSDR SWIA202265730None · corrodedSTRINGER JOINT SPLICE 25L CORRODED AT FS333. (C CHECK RO 5/23/22) REPLACED STRINGER JOINT SPLICE 25L AT FS333 REF DWG SH670-32420 REV. E, CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265729None · corrodedSTRINGER JOINT SPLICE AT 24L CORRODED AT FS333. (C CHECK RO 5/23/22) REPLACED STRINGER JOINT SPLICE AT 24L AT FS333 REF DWG SH670-32420 REV. E, CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265728None · corrodedSTGR 23R CORRODED BETWEEN FS333 - FS379. (C CHECK RO 5/23/22) REPLACED STGR 23R BETWEEN FS333 TO FS379 REF DWG SH670-31350 REV. A, CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265727None · corrodedSTRINGER JOINT SPLICE CORRODED AT 22L / FS333. (C CHECK RO 5/23/22) CORROSION ON JOINT SPLICE AT STGR 22L, FS333 TO BE OUT OF LIMITS REF. CRJ-900 SRM, 53-00-00-101-001-A01. REMOVED AND REPLACED STRINGER JOINT SPLICE 22L AT FS333 REF. CRJ-900 SRM 51-42-0SDR SWIA202265726None · corrodedSTGR 22R CORRODED BETWEEN FS333 - FS349. (C CHECK RO 5/23/22) REPLACED STGR 22R BETWEEN FS333 TO FS349 REF DWG SH670-31350 REV. A, AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265725None · corrodedSTGR 21R CORRODED BETWEEN FS333 - FS349. (C CHECK RO 5/23/22) REMOVED DAMAGE AND EVALUATED REPAIR. REPAIR FOUND TO BE BE OUT OF LIMITS. REMOVED AND REPLACED STRINGER 21R SECTION FROM FS333 - FS349, P/N SH670-31383-1, REF: CRJ900 SRM 51-42-06-001-001-A01,SDR SWIA202265724None · corroded25L CORRODED BETWEEN FS333 -FS349. (C CHECK RO 5/23/22) REPLACED STRINGER 25L FROM FS333 TO FS364 REF DWG SH670-32050 REV. J, CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265723None · corrodedSTGR 24L CORRODED BETWEEN FS333 - FS349. (C CHECK RO 5/23/22) CORROSION ON STGR 24L BETWEEN FS333-FS349 FOUND TO BE OUT OF LIMITS IN REF TO CRJ900 SRM 53-21-03-101-006-A04. CUT AWAY SECTION OF STGR 24L FROM APPROX FS370-FS333 AND INSTALLED NEW STRINGER SSDR SWIA202265722None · corrodedSTGR 22L CORRODED BETWEEN FS349 / FS364. (C CHECK RO 5/23/22) CORROSION ON STGR 22L BETWEEN FS349-FS364 FOUND TO BE OUT OF LIMITS REF. CRJ-900 SRM, 53-21-03-101-006-A04. REPAIRED AND INSTALLED STGR 22L NEW SECTION AND REPAIR SPLICE FROM FS333-FS370.50 SDR SWIA202265721None · corrodedSTGR 21L CORRODED BETWEEN FS349 / FS364. (C CHECK RO 5/23/22) REPLACED STRINGER 21LH BETWEEN FS333 TO FS379 IN REF TO CRJ900 SRM 51-42-06-001-001-A01 AND DWG SH690-31350 REV M. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265719None · corrodedSTRINGER 27 CORRODED BETWEEN FS310.00/FS333.00. (C CHECK RO 5/23/22) REPLACED STRINGER 27 BETWEEN FS310.00 TO FS333.00 REF DWG SH670-31630 REV. K, CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECKSDR SWIA202265718None · corrodedSTRINGER 27 CORRODED BETWEEN FS280.00/FS295.00. (C CHECK RO 5/23/22) INSTALLED NEW STRINGER 27 FROM FS280.00 TO FS303.00 IN REF TO CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01 AND DWG: SH670-31630 REV K. SEE CONTINUATION CARD FOR DETASDR SWIA202265717None · corrodedSTRINGER 26RH CORRODED BETWEEN FS295.00/FS310.00. (C CHECK RO 5/23/22) REPLACED STRINGER 26RH BETWEEN FS280.00 TO FS333.00 REF CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01 AND DWG SH670-31630 REV.K. COMPLIED WITH 51-900-1002-SKY. LSDR SWIA202265716None · damagedREMOVE AND REPLACE STR21R FROM FS477.00 TO FS621.00. (C CHECK RO 5/23/22) REMOVED STRINGER STGR21R FROM FS477.00 TO FS 693.00 REF. CRJ900 SRM 51-42-06-001-001-A01 / INSTALLED NEW STRINGER P/N: 690-33211-3A PO: T57891 STGR21R FROM FS477.00 TO FS 693.00 RSDR SWIA202265715None · damagedREMOVE AND REPLACE STR18R FROM FS477.00 TO FS661.00 +96. (C CHECK RO 5/23/22) - REMOVED STGR18R SECTION FROM FS477 TO FS661+96, REFERENCE CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01. / - INSTALLED NEW REPLACEMENT STGR18R SECTION SDR SWIA202265819None · corrodedRH STRINGER 18 BETWEEN FS. 485.00 AND FS. 517.00 HAS CORROSION. (C CHECK RO 5/23/22) REMOVED CORROSION FROM STR 18R REF. CRJ 900 SRM 51-21-06-001-001-A01. ORIGINAL MATERIAL THICKNESS OF STR 18R BETWEEN FS485.00 AND FS517.00 IS .080 REF. CRJ 900 SRM 53-31SDR SWIA202265818None · corrodedRH STRINGER 18 BETWEEN FS. 565.00 AND FS. 581.00 HAS CORROSION. (C CHECK RO 5/23/22) REMOVED CORROSION FROM STR 18R REF. CRJ 900 SRM 51-21-06-001-001-A01. ORIGINAL MATERIAL THICKNESS OF STR 18R BETWEEN FS565.00 AND FS581.00 IS .080 REF. CRJ 900 SRM 53-31SDR SWIA202265817None · corrodedRH STRINGER 18 BETWEEN FS. 613.00 AND FS. 629.00 HAS CORROSION. (C CHECK RO 5/23/22) REMOVED CORROSION FROM STR 18R REF. CRJ 900 SRM 51-21-06-001-001-A01. ORIGINAL MATERIAL THICKNESS OF STR 18R BETWEEN FS613.00 AND FS629.00 IS .080 REF. CRJ 900 SRM 53-31SDR SWIA202265816None · corrodedRH STRINGER 18 BETWEEN FS. 661.00+32 AND FS. 661.00+74 HAS CORROSION. (C CHECK RO 5/23/22) REMOVED CORROSION FROM STR 18R REF. CRJ 900 SRM 51-21-06-001-001-A01. ORIGINAL MATERIAL THICKNESS OF STR 18R BETWEEN FS661.00+32 AND FS661.00+74 IS .080 REF. CRJ 9SDR SWIA202265711None · corrodedSTRINGER SPLICE AT R/H STR21 AND FS477.00 HAS CORROSION. (C CHECK RO 5/23/22) CORROSION ON STR 21R SPLICE AT FS477.00 IS DEEP PITTING CORROSION ON MULTIPLE SURFACES AND IN A NO DAMAGE ALLOWED AREA AND IS FOUND TO BE OUT OF LIMITS REF. CRJ 900 SRM 53-31-0SDR SWIA202265710None · corrodedRH STRINGER 20 BETWEEN FS. 437.00 AND FS. 453.00 HAS CORROSION. (C CHECK RO 5/23/22) REMOVED DAMAGED SECTION OF STGR 20R FROM FS349 TO FS477 AND REPLACED WITH NEW STRINGER SECTION REF. CRJ-900 SRM, 51-42-06-001-001-A01 AND DWG SH670-31401 REV A. COMPLIESDR SWIA202265709None · corrodedRH STRINGER 19 BETWEEN FS. 437.00 AND FS. 453.00 HAS CORROSION. (C CHECK RO 5/23/22) CORROSION ON RH STGR19R BETWEEN FS437.00 AND FS453.00 FOUND TO BE OUT OF LIMITS REF. CRJ-900 SRM, 53-21-03-101-007-A04. REMOVED AND REPLACED RH STGR 19R BETWEEN FS349 TOSDR SWAA2022032886265Bracket · crackedKEEL BEAM STA 460 ANGLE BRACKET CRACKED / [01] R&R'ED KEEL BEAM STA 460 L/H ANGLE BRACKET IAW SRM 51-40-02.SDR SWIA202265748None · corrodedSTGR 23R CORRODED BETWEEN FS280 - FS333. (C CHECK RO 5/23/22) REMOVED AND INSTALLED NEW STGR23R BETWEEN FS280.00 AND FS333.00 REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01 AND DWG SH670-31630 REV K, COMPLIED WITH SKYWEST TASK CARD SDR SWIA202265701None · corrodedSTGR 22R CORRODED BETWEEN FS295 - FS310. (C CHECK RO 5/23/22) REPLACED STGR 22R BETWEEN FS295 TO FS310 REF DWG SH670-31630 REV. K, CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOSDR SWIA202265700None · corrodedSTGR 20R CORRODED BETWEEN FS280 - FS319. (C CHECK RO 5/23/22) REMOVED AND INSTALLED NEW STGR20R BETWEEN FS280.00 AND FS319.00 REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01 AND DWG SH670-31630 REV K, COMPLIED WITH TASK CARD 51-900-1SDR SWIA202265699None · corrodedSTRINGER SPLICE AT 23R / FS333 CORRODED. (C CHECK RO 5/23/22) REPLACED STRINGER SPLICE AT 23R AT FS333 REF DWG SH670-32420 REV. E, AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265698None · corrodedSTRINGER SPLICE AT 24R / FS333 CORRODED. (C CHECK RO 5/23/22) REPLACED STRINGER SPLICE AT 24R AT FS333 REF DWG SH670-32420 REV. E AND CRJ900 SRM 51-42-06-001-001-A01. COMPLID WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202265696None · corrodedCORROSION FOUND ON STGR 24R BETWEEN FS364 - FS333. (C CHECK RO 5/23/22) REPLACED STGR 24R SECTION FROM FS333 TO APPROX. FS370 REF CRJ900 SRM 53-00-03-201-001-A02. COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD.SDR EE4Y20225241510Keelbeam · corrodedDURING THE STRUCTURAL INSPECTION, IT WAS FOUND ON FWD CARGO COMPT. BETWEEN BS 500G AND BS 520, (S-28L LEVEL) THE KEEL BEAM LOWER FLANGES CORRODED. THE REPAIR WAS CARRIED OUT UNDER ASAP E.O. #5322-020 REV-IR A INSTRUCTIONS WITH FAA FORM 8110-3 APPROVAL.SDR SWAA2022042086158Bracket · crackedCRACK SUPPORT BRACKET BODY STATION 540 RBL6 KEEL BEAM 2022-148145 / [01] REPLACED SUPPORT BRACKET BODY STATION 540 RBL6 KEEL BEAM IAW SRM B737-700 51-10-02. TOOL USED DIGITAL CALIPER P/N: 500-197-30N S/N: A21043225; DUE DATE: 10/AUG/22.;[02] REPLACED SUPPORT BSDR AALA202203310838Support Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED KEEL BEAM HORIZONTAL SUPPORT ANGLE AT BS 663 AND RBL 12. REPAIRED SUPPORT ANGLE PER SRM 57-10-10-2R-5SDR SWIA202265692None · corrodedSTGR 26L HAS CORROSION ON LOWER FLANGE BETWEEN FS280.00 AND FS310.00. (C CHECK RO 5/23/22) REPLACED STGR 26L BETWEEN FS280.00 AND FS333.00 REF DWG SH670-31630 REV. K AND CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01. COMPLIED WITH 5SDR SWIA202265691None · corrodedSTGR 25L HAS CORROSION ON LOWER FLANGE BETWEEN FS295.00-FS310.00. (C CHECK RO 5/23/22). (C CHECK RO 5/23/22) REPLACED STGR 25L FROM FS280.00 TO FS333.00 REF DWG SH670-31630 REV. K, CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01. CSDR SWIA202265690None · corrodedSTGR 24L HAS CORROSION ON LOWER FLANGE BETWEEN FS295.00 AND FS310.00. (C CHECK RO 5/23/22) REPLACED STGR 24L FROM FS280.00 TO FS333.00 REF DWG SH670-31630 REV. K, CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01. COMPLIED WITH 51-900-100
Back to JASC 5314