JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023013080288Floorbeam · crackedCRACK STIFFENER FLOOR STRUCTURE LOCATED AT BS 540 BETWEEN BL0 AND LBL 24.75 WL 208.1 CENTER SECTION 2022-691469<[01] REPLACED STIFFENER LOC FLOOR STRUCTURE AT BS 540 BETWEEN BL0 AND LBL 24.75 WL 208.1 CENTER SECTION PASSENGER CABIN IAW B737-700 SRM 51-10-02; ISDR R61A2022122900800Floorbeam · corrodedCF III, FR 80. AFT CARGO RH CENTER FLOOR SUPPORT CORRODED BETWEEN STR 29R AND 29L. REMOVED AND REPLACED FLOOR SUPPORT IN CF III IN AFT CARGO AT FR80 BETWEEN STR 29R AND STR 29L. IAW SRM 51-41-01SDR SWAA2022122980322Splice Strap · corrodedCORROSION ON AFT CARGO COMPARTMENT FLOORBOARD SPLICE STRAP LOCATED ON BS727D PLUS 5IN ON WL156.4 AND BTW LBL21 AND RBL21 2022-688510<[01] REPLACED FLOORBOARD SPLICE STRAP LOCATED ON BS727D PLUS 5IN ON WL156.4 AND BTW LBL21 AND RBL21 AT AFT CARGO COMPARTMENT IASDR FDEA202212102918Floorbeam · corrodedMAIN DECK FLOORBEAM CORRODED BS 1914, RBL 20 TO LBL 20. REMOVED AND FABRICATED FLOOR SUPPORT P/N AGA7085-501 PER DAC DWG AGA7085 - INSTALLED NEW FLOOR SUPPORT P/N AGA7085-501 PER DAC DWG AGA7544, AJC7382 AND SRM 51-38-01-0G 'MAJOR REPAIR'SDR DALA2022121308088Floorbeam · corrodedSHIP 659 AWR. CORROSION ON FLOOR SUPPORT STA 760 BTW RBL 45 AND RBL 62 AT W2 FLOOR STRUCTURE, IN REFERENCE NRC. 00608. CORRECTIVE ACTION: SUMMARY OF NRC 00779. FLOOR SUPPORT STA 760 BTW RBL 45 AND RBL 62 AT W2 FLOOR STRUCTURE WAS REPLACED PER B757-200 SRM. (25SDR CALA2022121203349Intercostal · crackedFLOOR BEAM INTERCOSTAL CRACKED IN MULTIPLE PLACES ALONG THE UPPER L CHANNEL BETWEEN FS1280, BL0. REPLACED NEW UPPER CHORD AT STATION 1260-1288 BL0 IAW SRM 51-40-07 PAR.7. WORKED PERFORMED AT AMES IN ILN ON N/R 152595-0100-0058 BY V931825 AS A MAJOR REPAIR.SDR AALA202303014899Dummy Rail · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOOR DUMMY RAIL AT FR 16 AND +Y503.2. MAINTENANCE REPLACED DUMMY RAIL PER SRM 51-42-11.SDR SWIA2023011367100Floorbeam · crackedSUSPECTED CRACKS AT 280 FLOORBEAM AT RBL9 AND LBL9. REPLACED NEW CLIPS AND ANGLES AT BS 280 FLOORBEAM AT RBL 9.0 AND LBL 9.0 ON CAMP 25925155, JOB 27678791, OP 330.SDR SWIA2022122967064Floorbeam · mechanic errorF.S. 280 TOP OF ANGLE BETWEEN LBL27 TO LBL36 HAS A SNOW MAN HOLE AROUND NUTPLATE. REPAIRED FS280 LBL27 TO LBL36 IAW MHIRJ REO 601R-53-11-3815 REV. -.SDR SWIA202267063Floorbeam · corrodedF.S. 280 FLOORBOARD SUPPORT ANGLE IS CORRODED BETWEEN LBL9 TO RBL9. REMOVED AND REPLACED CORRODED FS280 FLOORBOARD SUPPORT ANGLE BETWEEN LBL9 TO RBL9 IAW REO 601R-53-11-926 REV B.SDR AALA202212207167Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN RIGHT HAND FLOOR SUPPORT BREAK ASSEMBLY LOCATED AB BS 540 AND RBL 1. REPLACED BREAK ASSEMBLY PER AARD 51-00-05 -01.SDR DALA2022121208005Floorbeam · corrodedSHIP 659 CORROSION ON FLOOR STRINGER LBL 16 AND RBL 10, STA 750 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00206. FLOOR STRINGER LBL 16 AND RBL 10, STA 750 AT FWD CARGO COMPARTMENT WERE REPAIRED PER B757-200 SRM. (2529307)SDR DALA2022120807925Floorbeam · corrodedDURING INSPECTION FOUND CORROSION ON FLOOR BEAM ON STA 947 AND LBL 24 AT PAX CABIN FLOOR STRUCTURE (W2). FLOOR BEAM ON STA 947 AND LBL 24 AT PAX CABIN FLOOR STRUCTURE (W2) WAS REPAIRED PER B737-900ER SRM 53-70-51-2R REPAIR 5.SDR CALA2022120703327Floorbeam · crackedFLOORBEAM CRACKED AT STA.490 RBL 11. REMOVED AND REPLACED UPPER TEE, BS 490 RBL 11 IAW SRM 51-40-02, PARA 7.SDR SWAA2023011078638Floorbeam · corrodedCORROSION AT AFT CABIN WET AREA FLOORBEAM FWD FLANGE FASTENER HOLES BS 986.5, LBL 45. REMOVED CORROSION IAW SRM 51-40-02-0G-0, INSTALLED A REPAIR ANGLE AND STRAP IAW SRM 53-70-51-2R-6, ALTERNATIVE 4, FIGURE 205, SRM 51-40-02-0G, SRM 51-40-02-0G-0, AND SRM 5SDR SCNA20230110036Stringer · dentedDEFECT TC 00265 NR 00329: UPON REMOVAL OF EXISTING SKIN REPAIR S-13L AT APPROX. BS 1021 FOUND STRINGER DENTED OUT OF LIMITS. RESOLUTION: EXISTING SKIN REPAIRS STRINGER 13L DENT AT APPROX STA 1021 FOUND TO BE OUT OF LIMITS IAW B737 SRM 53-00-03-1A-1 STEP 4 (ASDR SWIA2022122967062Floorbeam · corrodedLBL9 FLOOR BEAM IS CORRODED BETWEEN F.S. 409+64 TO F.S. 409+80. INSTALLED NEW SERVICEABLE FLOOR BEAM IAW REO 601R-53-31-1256 REV.SDR SWIA2022122967061Floorbeam · corrodedRBL9 FLOOR BEAM IS CORRODED BETWEEN F.S. 409+32 TO F.S. 409+48. INSTALLED NEW SERVICEABLE RBL9 FLOOR BEAM CAP FROM F.S 409.00+5 F.S 409.00+118 IAW MHIRJ REO 601R-53-31-1254 DATED: 2022-12-12 REV: -- , CRJ 200 SRM 51-42-21 AND 51-42-06.SDR SWAA2022122979009Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 LBL0 WL 208.1 CENTER SECTION 2022-688143<[01] TOOL USED: DIGITAL CALIPER P/N: 500-196-30; S/N:A21033538; DUE DATE: 25-SEP-23.;[02] REPLACED ANGLE AND FASTENERS ON FLOOR STRUCTURE LOCATED AT BS 695 BL0 WL 208.1 CENTSDR SWAA2022122979011Stiffener · crackedCRACK STIFFENER FLOOR STRUCTURE PLATE LOCATED AT BS 540 BETWEEN LBL 24.5 AND LBL 45 WL 208.1 CENTER SECTION 2022-688200<[01] REPLACED STIFFENER FLOOR STRUCTURE PLATE LOCATED AT BS 540 BETWEEN LBL 24.5 AND LBL 45 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-10-0SDR SWAA2022122979012Stiffener · crackedCRACK STIFFENER FLOOR STRUCTURE LOCATED AT BS 540 BETWEEN BL0 AND LBL 24.5 WL 208.1. CENTER SECTION 2022-688188<[01] REPLACED STIFFENER FLOOR STRUCTURE LOCATED AT BS 540 BETWEEN BL0 AND LBL 24.5 WL 208.1. CENTER SECTION IAW B737-700 SRM 51-40-02 AND DRAWING 14SDR SWAA2022122979013Stiffener · crackedCRACK STIFFENER FLOOR STRUCTURE LOCATED AT BS 540 BETWEEN BL0 AND RBL 24.5 WL 208.1 CENTER SECTION 2022-688184<[01] REPLACED STIFFENER FLOOR STRUCTURE LOCATED AT BS 540 BETWEEN BL 0 AND RBL 24.5 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DRAWING 143SDR DALA2022120707861Floorbeam · crackedFRONT SPAR AT FRAME 36 FLOORBEAM & VERTICAL STIFFENER CRACKED. COMPLIED WITH ERA 599001-14 REV A SECTION II. (2527658)SDR AALA202212204851Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM AT STA 986.5 AND RIGHT BUTT LINE 44. INSTALLED REINFORCING MODIFICATION PER SRM 53-70-51-2R-6.SDR SCNA20230105011Floorbeam · corrodedCORROSION ON FLOORBEAM BS 986 RBL 45. CORROSION ON FLOORBEAM WAS REPAIRED IAW SRM 57-30-51-2R-6, PAR 4, FIG 205.SDR SCNA20230105010Floorbeam · corrodedCORROSION ON BS 986 FLOORBEAM LBL45. CORROSION ON 986 FLOOR BEAM LBL45 WAS REPAIRED IAW B737-800 SRM 53-70-51-2R-6 PAR. 4, FIG. 205 AND TABLE 204.SDR SWIA2022122767040Floorbeam · crackedINBOARD CLIPS FOUND CRACKED AT FS280 RBL9 AND LBL9 BEAMS. REMOVED AND REPLACED CRACKED INBD CLIPS WITH NEW CLIPS IAW REO 601R-53-21-3587 REV-, DWG 601R311011 REV C, AND SRM 51-42-21.SDR AALA202212092080Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FASTWENER HOLES OF UPPER SPLICE / SECTION CONECTING LOCATED INBOARD SIDE OF FLOOR BEAM AT FR 68 AND +Y1225. MAINTENANCE REPLACED SPLICE / SECTION CONECTING PER SRM 51-72-11.SDR DALA2022120507745Floorbeam · corrodedCABIN FLOORBEAM BS 347, RBL 40, FOUND CORRODED, FLOORBEAM REMOVED AND REPAIRED IAW PRI 603589.SDR DALA2023010900117Shim · corrodedCABIN FLOORBEAM, FOUND ONE SHIM CORRODED AT BS 945, LBL 11. REPAIRED THE SHIM IAW PRI 603755-14, REV 0, AND PRI 603755-14, REV 1.SDR AALA202212142634Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM LOCATED AT BS 986.5 AND LBL 43. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R PROCEDURE 4.SDR AALA202212148726Floorbeam · gougedAIRCRAFT IN BASE MAINTENANCE: GOUGE IN MAIN CABIN FLOORBEAM BS 727B, LBL 55. REPAIRED FLOORBEAM IAW EA 340488.SDR ASAA2022120241105Floorbeam · corrodedSTA 947 FLOOR BEAM L/H O/B LAV MOUNT CORRODED. GROUNDED - YES. DAMAGE FOUND TO BE OUT OF LIMITS CUT OUT DAMAGED SECTION OF FLOOR BEAM AND REPAIRED IAW B737-900 SRM 53-70-51-2R-5W=3 O=.180 R=0 L=6 D=.180.SDR YENA2022120801218Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION FOUND FLOORBEAM FRAME 87, Y=260 LH. CORROSION REMOVED AND FOUND OUT OF LIMITS IAW SRM 51-12-01, SRM 51-10-03, AND SRM 53-23-10/AD52. REPAIRED IAW SRM 53-23-10/R53. MAJOR REPAIR.SDR CALA2022120503284Floorbeam · corrodedCABIN STA303 LBL32&38 FLOOR BEAM FOUND CORROSION AS PER JC 63 -5310-1-2637 CARRIED OUT FLOOR BEAM REPAIR AT STA303 LBL32-LBL38 AS PER ECRA 5315-01181.THIS ECRA PROVIDES AN INSTRUCTION TO ACCOMPLISH A CATEGORY A REPAIR BASED ON THE INSTRUCTION PROVIDED BY SR 4-SDR CALA2022120503283Floorbeam · corrodedCABIN FLOOR BEAM FOUND CORROSION AT STA1582 LBL5-RBL5 AS PER JC 63-5300-1-2003 CARRIED OUT FLOOR BEAM AT STA1582 LBL5-RBL5 AS PER ECRA:5365 -01104.THIS ECRA PROVIDES AN INSTRUCTION TO ACCOMPLISH A CATEGORY A REPAIR BASED ON THE INSTRUCTION PROVIDED BY SR 4-567SDR CALA2022120503282Floorbeam · corrodedCABIN FLOOR BEAM FOUND CORROSION AT STA1562 LBL0-5 AS PER JC 63 -5300-1-2003 CARRIED OUT FLOOR BEAM REPAIR AT STA1562 LBL0-5 AS PER ECRA 5365-01105,THIS ECRA PROVIDES AN INSTRUCTION TO ACCOMPLISH A CATEGORY A REPAIR BASED ON THE INSTRUCTION PROVIDED BY SR 4-56SDR CALA2022120503281Floorbeam · crackedFLOOR BEAM CRACKED AT STA.490 BL 11. REFERENCE NR IS 151231-0200-0246.SDR ASAA2022120141271Floorbeam · corrodedSTA 947.5 HAS CORROSION AT I/B AND O/B LAV ATTACH POINTS. GROUNDED - YES. REPAIRED FLOOR BEAM STA 947.5 IAW 737-700 SRM 53-70-51-2R-5 REPAIR 5.W= 2" O= .180 R= 0.000 L= 67.5" D= .180.SDR SWIA2022122767039Floorbeam · corrodedDURING THE AUDIT OF THE 48 MONTH, TASK CARD 53-140-505, FOUND POSSIBLE CORROSION AROUND THE NUTPLATES ON TOP OF THE FS 280 BETWEEN RBL 9 AND RBL 27. REMOVED DAMAGE AND EVALUATED REPAIR. REPAIR FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FWD FLOORBEAM ANGLSDR CALA2022120203266Floorbeam · corrodedCABIN STA347 LBL25 FLOOR BEAM FOUND CORROSION AS PER JC 63-5310 -1-2637. CARRIED OUT FLOOR BEAM REPAIR AT STA347 LBL25 AS PER ECRA 5315-01182.SDR A6WA2023012638444Floorbeam · corrodedCORROSION ON CABIN FLOOR STRUCTURE SUPPORT P/N 601R38672-1 AT FS349.0 AND RBL19.0 TO RBL21. REMOVED CORROSION BY BLENDING CABIN FLOOR STRUCTURE SUPPORT. PERFORMED HFEC WITH NO INDICATIONS. RESTORED SURFACE PROTECTIVE FINISH. ALL WORK WITHIN LIMITS PERFORMED ISDR A6WA2023012638443Floorbeam · corrodedCORROSION ON CABIN FLOOR STRUCTURE CROSSBEAM AT FS349.0 AND RBL19.0 TO RBL24. REMOVED CORROSION BY BLENDING CABIN FLOOR STRUCTURE CROSSBEAM P/N 601R32005-149 AT FS349.0 AND RBL19.0 TO RBL24. FABRICATED STRAP FROM 0.050Ï¿½ ALUM. SHEET MATERIAL HEAT TREATED TOSDR A6WA2023012308441Floorbeam · corrodedCORROSION ON CABIN FLOOR STRUCTURE SUPPORT ANGLE AT SERVICE DOOR FS349 AND RBL28 TO RBL42. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED ANGLE SUPPORT ANGLE AT SERVICE DOOR FS349 AND RBL28 TO RBL42. RESTORED PROTECTIVE FINISH. ALL WORK WITHIN LIMITSSDR AALA202212149639Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM LOCATED AT BS 947.5 AND LBL 26. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5.SDR REXA2022120102665Floorbeam · crackedCKPT FLOOR PANEL 221ALF, LBL 12 AND RBL 12 SUPPORT ANGLES CRACKED JUST FORWARD OF FS280.00. REMOVED AND REPLACED SUPPORT ANGLES AT FS280 LBL 12 AND RBL 12 IAW CRJ900 SRM TASKS 51-40-11-001-001-A01 AND 51-42-06-001-001-A01.SDR REXA2022120102664Floorbeam · corrodedCKPT FLOOR PANEL 221ALF, LBL 12 AND RBL 12 SUPPORT ANGLES CRACKED JUST FORWARD OF FS280.00. REMOVED AND REPLACED SUPPORT ANGLES AT FS280 LBL 12 AND RBL 12 IAW CRJ900 SRM TASKS 51-40-11-001-001-A01 AND 51-42-06-001-001-A01.SDR REXA2022120102644Floorbeam · corrodedRH FS 280 FLOORBEAM FOUND TO BE CORRODED. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06-001-001-AO1 ,51-42-13-001-001-AO1 , 51-42-21-001-001-AO1.SDR SWAA2023011076567Floorbeam · corrodedCORROSION AT AFT CABIN WET AREA FLOOR BEAM FWD FLANGE FASTENER HOLES STA 986.5 LBL24 TO LBL 45. REMOVED CORROSION AT AFT CABIN WET AREA FLOOR BEAM FWD FLANGE FASTENER HOLE STA 986.5 AND LBL45 REF SRM 51-40-02-0G-0.<OUT OF LIMITS REF. SRM 53-70-51-1A-1; FIGURESDR SWIA2022122767031Floorbeam · corrodedCORROSION ON FLOORBEAM TOP FLANGE AT FS 424, LBL 27. BLENDED CORROSION ON FLOORBEAM TOP FLANGE IAW SRM 51-21-06. FOUND TO BE WITHIN LIMITS IAW REO 601R-53-41-3113, REV-.
Back to JASC 5315