JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202110041600Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 16 AND +Y1292. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR YENA2021093000619Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM -Y765 AND FR66 AT AFT GALLEY AREA (CPCP RELATED R EFER TO THE MPD TASK 534195-01) (REF NR 2021-408113); ACCOMPLISHED RAPAIR OF CORROSION AFFECTING AFT FUSELAGE FUSELAGE SEAT TRACK PN:D5347220927000 LOCATED BETWEENSDR YENA2021093000618Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION FLOOR BEAM +160.5 AND FR68 AT AFT GALLEY AREA (CPCP RELATED REFER TO THE MPD TASK 534195-01) (REF NR2021-4081111); R & R FLOOR BEAM Y160.5 LOC BTW FR 68 TO FR 70 AFT GALLEY AREA IAW A321 SRM 51-42-11, SRM 51-72-11 AND DRAWINSDR IPXA2021102075151Floorbeam · corrodedINSPECTION TYPE:3C AFT CARGO HAS A FLOOR SUPPORT ANGLE FOUND WITH CORROSION AT STA Y=1841 BETWEEN X=-20 AND X=-57. REPAIRED CORRORED FLOOR SUPPORT ANGLE AT STA Y=1841 BETWEEN X-20 AND X=-57 IAW EA 011-5310-01-A9383 REV I/R AND UPS EO MD11-5310-81009-A (MAJORSDR AALA202110015820Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=1.00 IN, W=1.50 IN, D=0.15 IN, ON FLOOR BEAM LOCATED AT STA 987 AND LBL 28 TO LBL 42. REPAIRED PER EA 330804 AND SRM 53-00-51R.SDR SWAA2021110319942None · corrodedCABIN FLOOR BEAM 380 TOP CAP HAS LIGHT CORROSION 20' RIGHT OF CENTERLINE ; / [01] CLEANED AREA NO CORROSION FOUND AT CABIN FLOOR BEAM 380 TOP CAP 20' RIGHT OF CENTER LINE; [02] SOPM 20-30-03; [03] VERIFIED STEP # 1 AND # 2; [04] OK TO TREAT AND PRIME; [05] TRESDR AALA202110029825Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM FASTENER HOLE LOCATED AT STA 987 AND LBL 43. REPAIRED PER EA 330762 AND SRM 53-00-51-2R-1.SDR SWAA2021101320236None · corrodedPASSENGER CABIN FLOOR;STA.947 FLOOR BEAM CORRODED AT GALLEY FITTING RBL 50 WL 208 / REMOVED CORROSION FROM PASSENGER CABIN FLOOR; STA 947 FLOOR BEAM AT RBL 50; WL 208 IAW B737 SRM 51-10-02-0G-0. FOUND OUT OF LIMITS .180' ORIG .118' REMAIN .062' REMOVED IAW B73SDR SWAA2021101320234None · corrodedPASSENGER CABIN FLOOR;STA.986 FLOOR BEAM OUTBD FASTNER HOLE CORRODED RBL 45 WL 208 / BLENDED CORROSION AT PASSENGER CABIN FLOOR STA 986 FLOOR BEAM OTBD FASTENER HOLE RBL 45 WL 208. ORIGINAL THICKNESS .150'; REMAINING .132'; LOSS OF .013' FOUND OT OF LIMITS IAWSDR SWAA2021101321135None · corrodedPASSENGER CABIN FLOOR;STA.947 FLOOR BEAM CORRODED AT GALLEY FITTING RBL 50 WL 208 / REMOVED CORROSION FROM PASSENGER CABIN FLOOR; STA 947 FLOOR BEAM AT RBL 50; WL 208 IAW B737 SRM 51-10-02-0G-0. FOUND OUT OF LIMITS .180' ORIG .118' REMAIN .062' REMOVED IAW B73SDR SWAA2021101321133None · corrodedPASSENGER CABIN FLOOR;STA.986 FLOOR BEAM OUTBD FASTNER HOLE CORRODED RBL 45 WL 208 / BLENDED CORROSION AT PASSENGER CABIN FLOOR STA 986 FLOOR BEAM OTBD FASTENER HOLE RBL 45 WL 208. ORIGINAL THICKNESS .150'; REMAINING .132'; LOSS OF .013' FOUND OT OF LIMITS IAWSDR MASA20210917449Floorbeam · corrodedCORROSION AFFECTING THE FLOOR BEAM AT FS1015, LBL 9.00. PERFORMED PERMANENT REPAIR IAW CRJ700/900 SRM 53-61-43-991-801, ITEM 1B, EA 80-2021-136.SDR SWAA2021101318316Floorbeam · crackedCRACKED FLOORBEAM, BS 540, BL 0 - LBL 24.5, WL 208.1. REMOVED FLOORBEAM IAW SRM 51-40-02-0G-0. LOCATED & DRILLED NEW FLOORBEAM IAW SRM 51-40-05-0G-0, AND DWG 143A0060, SHEET 46. INSTALLED THE NEW FLOORBEAM IAW SRM 51-40-02-0G-0, AND DWG 143A0060.SDR DALA2021091705555Floorbeam · corrodedSHIP 6807 CORROSION ON FLOOR STRUCTURE BEAM BSTA 1280 BTW BL0 TO LBL 40 PAX CABIN. CORRECTIVE ACTION: SUMMARY OF NRC 00554 FLOOR STRUCTURE BEAM BSTA 1280 BTW BL0 TO LBL 40 PAX CABIN WAS REPAIRED PER ER/A 481634-14MA REV. B; SECTION I: PERMANENT REPAIR. (194783SDR MASA20210914419Floorbeam · crackedCOCKPIT FLOOR BEAM AT FS 280, RBL 12.00 WAS FOUND WITH CRACK DAMAGE. PERFORMED PERMANENT REPAIR IAW CRJ 700/900 SRM 53-11-43, FIGURE 53-11-43-991-801 ITEM 109D, EA 72-2021-146.SDR MASA20210914402Floorbeam · crackedCOCKPIT FLOOR BEAM AT FS 280, LBL 12.00 WAS FOUND WITH CRACK DAMAGE. PERFORMED PERMANENT REPAIR IAW CRJ 700/900 SRM 53-11-43, FIGURE 53-11-43-991-801 ITEM 108G , EA 72-2021-145.SDR VNAA202109139995Floorbeam · crackedCOPILOT SIDE FLIGHT COMPARTMENT FLOOR BEAM BETWEEN RBL9 TO RBL18 IS CRACKED ON FWD SIDE OF FS 280.00.SDR FDEA202109112315Floorbeam · corrodedMAIN DECK FLOOR PANEL SUPPORT ANGLE AT STA 1661 RBL 75 TO 107 CORRODED AROUND SEVERAL CLIPNUTS REMOVED AND REPLACE FLOOR SUPPORT REF DOUGLAS DRAWING AFA-3853.SDR FDEA202109112316Floorbeam · corrodedMAIN DECK FLOORBOARD SUPPORT ANGLE STA. 1661 LBL=107.25 EXFOLIATED/CORRODED. (MRKD) REMOVED AND REPLACED WITH NEW FABRICATED FLOOR BOARD SUPPORT P/N AFA3853-501 REF DAC DWG AFA3853 AND SRM 51-33-01 VOL. 2SDR CALA2021091301561Floorbeam · corrodedREF AMES N/R 0870 UPPER AFT PASSENGER CABIN. FOUND CORROSION IN AREAS OF THE BS 1640 FLOOR BEAM AND THE R4 DOO R INTERCOSTAL BLENDED, DAMAGE FOUND TO BE OUT OF LIMITS, REPAIRED IAW B757 SRM 53-00-51-02 ON 1640 FLOOR BEAM / R4 DOOR. SEE BACK AND PWS 1-4 FOR PARSDR CALA2021091001553Floorbeam · corrodedREF AMES N/R 0870 UPPER AFT PASSENGER CABIN. FOUND CORROSION IN AREAS OF THE BS 1640 FLOOR BEAM AND THE R4 DOO R INTERCOSTAL BLENDED, DAMAGE FOUND TO BE OUT OF LIMITS, REPAIRED IAW B757 SRM 53-00-51-02 ON 1640 FLOOR BEAM / R4 DOOR. SEE BACK AND PWS 1-4 FOR PARSDR DALA2021091305416Floorbeam · corrodedSHIP 649 DURING EXECUTION OF NRC 1001 HAS BEEN NOTICED CORROSION ON FLOOR CHANNEL SUPPORT STA 297 FROM RBL31 TO RBL36. PASSENGER CABIN. CORRECTIVE ACTION: SUMMARY OF NRC 1011: FLOOR CHANNEL SUPPORT STA 297 FROM RBL 31 TO RBL 36 WAS REPAIRED PER B757-200 SRM 51SDR DALA2021091005338Floorbeam · corrodedSHIP 649 CORROSION ON FLOOR CHANNEL SUPPORT STA 340 FROM 34/39 LBL AT PASSENGER CABIN FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY NRC 00770 FLOOR CHANNEL SUPPORT WAS REPLACED PER B757-200 SRM. (1941314)SDR SWAA2021110932927None · corrodedITEM TO ADD MISSING MEASUREMENT FOR ITEM CORROSION AFT PASSENGER COMPARTMENT FLOOR STRUCTURE; FLOOR BEAM TOP SURFACE HAVE SURFACE CORROSION BETWEEN BS 986.5 AND RBL -24.7 TO RBL 46. [TTG8Q006ELS6] ; / [01] ADDED MISSING CORROSION MEASUREMENTS FOR TASKCARD TTG8SDR AALA202109245922Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR BEAM ON UPPER SURFACE AT FR66, WL -500, AND BL 1162.5, MEASURING L=0.5 IN, W=0.5 IN, D=0.02 IN. REPLACED FLOOR BEAM WITH NEW IAW SRM 51-72-11 AND DRAWING D53472815.SDR AALA202109228083Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM LOCATED AT FR 66, WATERLINE Z-500, AND BUTT LINE Y765. 1.250 INCHES LONG BY 0.500 INCHES WIDE BY 0.035 INCHES DEEP. REMOVED AND REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA202109220278Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM LOCATED AT FR70 - 5", WATERLINE Z-500 AND BUTT LINE Y765 0.750 INCHES LONG BY 0.750 INCHES WIDE BY 0.040 INCHES DEEP. REMOVED AND REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA202109214654Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR BEAM AT FR70-5 IN, WL -500, AND BL -765, MEASURING L=0.5 IN, W=0.5 IN, D=0.025 IN. REPLACED FLOOR BEAM WITH NEW IAW SRM 51-72-11.SDR AALA202109215766Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR BEAM AT FR66, WL -500, AND BL Y-512.5, MEASURING L=0.5 IN, W=0.5 IN, D=0.025 IN. REPLACED FLOOR BEAM WITH NEW IAW SRM 51-72-11.SDR AALA202109218119Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR BEAM AT FR66, WL -500, AND BL Y-515, MEASURING L=1.0 IN, W=1.0 IN, D=0.025 IN. REPLACED FLOOR BEAM WITH NEW IAW SRM 51-72-11.SDR AALA202109210587Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR BEAM AT FR64+10 IN, WL -500, AND BL Y-765, MEASURING L=1.5 IN, W=1.0 IN, D=0.015 IN. REPLACED FLOOR BEAM WITH NEW IAW SRM 51-72-11.SDR R61A2021091900751Floorbeam · corrodedCFIII CORROSION FOUND ON FLOORBOARD SUPPORT AT FR86, ON CROSSBEAM APPROX RBL 36, REPLACED FLOOR SUPPORT P/N 170-66796-001 IAW SRM 51-41-01 PSE 53-23-005SDR AALA202109146257Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM LOCATED AT STA FR 70, WATERLINE Z-500, BUTT LINE Y 160.5. REMOVED AND REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA202109137513Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM AT FR 70 AND -Y150.5. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR DALA2021090705229Floorbeam · corrodedSHIP 3250 CORROSION FLOOR BEAM -Y765 FR20 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11, AND A320 SRM 51-72-11. (1936802)SDR DALA2021090705228Floorbeam · corrodedSHIP 3250 CORROSION FLOOR BEAM +Y765 AT FR16 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11, AND A320 SRM 51-72-11. (1936718)SDR DALA2021090705227Floorbeam · corrodedSHIP 3250 CORROSION FLOOR BEAM -Y1292 AT FR20 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11, AND A320 SRM 51-72-11. (1936706)SDR CALA2021090601510Floorbeam · corrodedB757-53-3-0571 FLOOR BEAM AT STA 1640 BL0 IS CORRODED.SDR IPXA2021090273490Floorbeam · corrodedINSPECTION TYPE:SEG4MAIN DECK FLOOR BEAM STA 1600 BETWEEN KBK 24.75 AND 45.50 HAS SEVERAL CORROSION.REPAIRED PER EO B757-5310-81449-A. RCD 217045 AND VT MAE EA 757-5360-A2675.SDR CALA2021090101486Floorbeam · corrodedREF AMES NR 0499 CORROSION FOUND ON FLOOR SUPPORT NEXT TO SEAT T RACK AT STA 720 RBL 33 UNDER FLOOR PNL 232LF. REMOVED FLOOR SUPPORT BY SEAT TRACK AT STA 720, RBL 33 FOUND TO BE OUT OF LIMITS, FABRICATED NEW FLOOR SUPPORT USING 7075-T6-071 PO # 0179415 IAW B75SDR SWAA2021100513360None · corrodedCORROSION FLOOR BEAM BS 987 RBL 44 AT PASSENGER CABIN ; 2021-393051 / PERFORMED PERMANENT REPAIR LOCATED BS 986.5 AND BTW RBL RBL 19 TO RBL 51 IAW B737-700 SRM 53-70-51-2R-4 REPAIR 4 ALTERNATIVE 2 FIG 205 RIISDR REXA2021090900710Floorbeam · corroded"FS 280.00 CROSSBEAM 5 ANGLE IS CORRODED.
" "REMOVED AND REPLACED 280 J ANGLE PN CC690-34095-1 IAW SRM
51-42-21-001-001-A01, 51-42-06-001-001-A01.
CORRECT PN CC670-34095-1.
WVAC EMP STAMP # 703 MTC. SDR AALA202109173529Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM LOCATED AT STA 312 AND LEFT BUTT LINE 45.6. INSTALLED REINFORCEMENT ANGLES PER SRM 51-40-02.SDR FDEA202108262106Floorbeam · crackedMAIN FLOOR BEAM AT STA 580 LBL 45.5 IS CRACKED. REPAIRED FLOOR BEAM AT STA 580 LBL 45.5 IAW FEDEX E.A. F-5310-T0363608 AND FEDEX STANDARD REWORK DRAWING SR57-53-004.SDR CALA2021082501433Floorbeam · corrodedA3NB-53-3-6185 MAIN CABIN FLOOR SUPPORT Y1292 FR68 CORRODED.(DOT 38-27)() REPLACED FLOOR SUPPORT P/N: D5347218820400 BTCH: 0002716528 IAW A320 SRM 51-42-11 AND SRM 51-72-11-911-001. ATTACHED FORMS 46-00 24 AND 44-0008. EMP# V934700 WORK ACCOMPLISHED AT ST ENGISDR SWAA2021100410765None · corrodedCORROSION ON BS 986 FLOOR BEAM UPPER CHORD LBL 44 WL 208 ; / [01] WORK COMPLETED ON CARD NO. M-21-153-00612 (2529).; [02] VERIFIED WORK COMPLETED ON CARD NO. M-21-153-00612 (2529).SDR SWAA2021100410764None · corrodedCORROSION ON BS 986 FLOOR BEAM UPPER CHORD RBL 44 WL 208 ; / [01] REMOVED CORROSION ON BS986 FLOOR BEAM UPPER CHORD RBL44 WL208 IN AREA OF 0.9' BY 1.1' BY A DEPTH OF 0.065' PER SRM 51-10-02-0G-0 AND SRM 53-70-51-1A-1. OUT OF LIMITS PER SRM 53-70-51-1A-1.; [02]SDR AALA202109016652Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND A CORRODED AREA ON FLOORBEAM LOCATED AT STA 986, RIGHT BUTT LINE 51.INSTALLED STRAP REPAIR FOR OVER SIZED HOLE PER SRM 53-70-81-2R-6.SDR IPXA2021082473105Floorbeam · corrodedINSPECTION TYPE:SEG4CORROSION ON MAIN CARGO FLOOR SUPPORT BEAM STA 1200 BETWEEN RBL 45.5 AND RBL 24.75REPAIRED IAW EO B757-5310-81278-A AND VT MAE EA 757-5360-27-A2661 REV-SDR CALA2021082501426Floorbeam · corrodedA3NB-53-3-6185 MAIN CABIN FLOOR SUPPORT Y765 HAS CORROSION AT FR 66.(DOT 38-39)() AFTER CHECKING THE DAMAGE IS OUT OF LIMITS CORROSION IN HARD POI NT EXCLUDED AREA IAW SRM 53-00-14-283-002 FIG 00, REMOVED DAMAGE AREA IAW SRM 51-42-11. INSTALLED NEW FLOOR SUPPO