JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021042759660Floorbeam · corrodedCORROSION ON FLOOR SUPPORT SPLICE AT AFT CARGO BAY BS773 LBL20 TO RBL20 WL157. / NO ALLOWABLE DAMAGE LIMITS IN SRM; REPAIR BY REPLACEMENT. REPLACED ACB FLOOR SUPPORT SPLICE AT BS 773 IAW SRM 51-40-02 AND BOEING DWG 146A7500SDR SWAA2021042759659Floorbeam · corroded***CORROSION*** ON FLOOR SUPPORT SPLICE AT AFT CARGO BAY BS727D+6 LBL20 TO RBL20 WL156. / NO ALLOWABLE DAMAGE LIMITS IN SRM; REPAIR BY REPLACEMENT. REPLACED ACB FLOOR SUPPORT SPLICE AT BS 727D+6' IAW SRM 51-40-02 AND BOEING DWG 146A7500SDR REXA2021032500266Floorbeam · corrodedR/H ANGLE FOR PANEL 221ALF IS CORRODED. - C/A: REMOVED AND REPLACED ANGLE IAW CRJ 700 SRM 51-40-11-001-001-A01 & 51-42-06-001-001-A01SDR DALA2021032601800Floorbeam · crackedSHIP 3241 WINGS / CENTER WING / FRONT SPAR AT FR36 / FLOOR BEAM & VERTICAL STIFFENER / CRACKS. CORRECTIVE ACTION: COMPLIED WITH ER/A 32-587692. (1764327)SDR SWIA202158240Floorbeam · cracked* 280.00 BEAM CRACKED ON AFT SIDE AT RBL18 (MARKED). (C-CHECK RO 5/20/2021) REMOVED AND REPLACED NEW RH FLOORBEAM P/N CC670-34094-2S AT FS280 REF CRJ700 SRM51-42-06-001-001-A01, SRM51-42-22-001-001-A01 AND DWG NO. CC670-34010 REV -K. SEE CONTINUE CARD FSDR AALA202104219014Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CABIN FLOOR BEAM LOCATED AT STA 986.5 RBL 43. REPAIRED PER EA 326601 AND SRM 53-00-51-2R-1.SDR AALA202104169003Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED FLOOR BEAM LOCATED AT STA 986.5 RBL 45. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R AND EA 326630.SDR AALA202104159011Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOORBEAM AT STA 946.5 AND RBL 6, MEASURING L=0.75 IN, W=0.75 IN, D=0.066 IN. ACCOMPLISHED PERMANENT REINFORCING REPAIR WITH NESTED ANGLES IAW SRM 53-70-51-2R-5.SDR AALA202104159026Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND CORRODED FLOOR BEAM LOCATED AT STA 986.5. REPAIRED FLOOR BEAM WITH REINFORCEMENT PER SRM 53-00-51-2R AND EA 326599.SDR IPXA2021040867941Floorbeam · corrodedINSPECTION TYPE:C2AFT CARGO COMPT FLOOR SUPPORT ANGLE CORRODED AT STA.1841 BETWEEN STR 42L-STR 42R.REMOVED,FABRICATED AND REPLACED FLOOR SUPPORT ANGLE IAW SRM 51-35-01 AND 51-33-01 (MINOR).SDR AALA202103269007Splice · damagedAIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLE FLOOR BEAM SPLICE Y1292 AT FR66 LOWER OUTBOARD SPLICE AT AFT GALLEY. REPLACED SPLICE COUPLING.SDR DALA2021032501774Floorbeam · corrodedSHIP 3255 CORROSION FLOOR BEAM -Y765 AT LEVEL FR 68 RH SIDE IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1763778)SDR SWIA202158061Floorbeam · corrodedF.S.280 L/H FLOOR BEAM CORRDED BETWEEN LBL11 AND BL0. (C-CHECK RO 5/3/2021) REMOVED AND INSTALLED NEW LH FS280 FLOORBEAM REF CRJ 900 SRM 51-42-13-001-001-A01, 51-42-22-001-001-A01, 53-11-10-201-004-A01 AND DWG CC670-34010 REV K. COMPLIED WITH 51-900-10SDR SWAA2021050358602Floorbeam · crackedCRACK FLOOR BEAM LOCATED BS 328 RBL 24 AT FWD GALLEY AREA / REPAIRED FLOOR BEAM LOCATED BS 328 BTW LBL 5 TO RBL 60 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-7 REPAIR 7SDR IPXA2021041268126Floorbeam · crackedINSPECTION TYPE:C2FWD. CARGO FLOOR BEAM IS CRACKED AT STA. 6-70, X= -57.5 AND Z= -98.REPAIRED CRACKED FLOOR BEAM AT STA. 6-70, X= -57.5 AND Z= -98 IAW SRM 53-40-51 REPAIR 1 FIG. 202. (MAJOR)SDR HNAA2021033000126Floorbeam · corrodedFORWARD DIGITAL AFT LH SIDE (LH BEAM) CORRODED AT PREVIOUS REPAIR ON NUTPLATE....REMOVED DAMAGED PREVIOUS REPAIR DOUBLER ON GALLEY FWD DIGITAL AFT LH SIDE AT LH BEAM AND FABRICATED AND INSTALLED NEW DOUBLER IAW EMB-145 SRM 53-21-10 ITEM 2 AND EO1-05-21-0052.SDR HNAA2021033000116Floorbeam · corrodedFWD DIGITAL IS CORRODED AT LH OUTBD SCREW HOLE AT FR 15....PERFORMED CUTOUT AS REQUIRED TO REMOVE DAMAGE FROM FWD GALLEY DIGITAL AT LH OUTBD NUTPLATE HOLE AND FABRICATED AND INSTALLED DOUBLER AND FILLER IAW EMB-145 SRM 53-21-10 ITEM 2. AND EO-1-05-21-0052 SEE SDR HNAA2021033000114Floorbeam · corrodedAFT DIGITAL IS CORRODED AROUND SCREW HOLE ON LH BEAM AT FR 17.(PREVIOUS BLEND)....PERFORMED CUT-OUT AND FABRICATED REPAIR DOUBLER/FILLER AND INSTALLED ON AFT DIGITAL ON LH BEAM AT FR 17.(PREVIOUS BLEND) IAW ETD-2021-145-006649 AND EO1-05-21-0052 SEE TURNOVER FSDR DALA2021032401752Floorbeam · corrodedSHIP 3235 CORROSION FLOOR BEAM +Y1162.5 LOCATED AT LEVEL FR68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11. (1762761)SDR DALA2021032301712Floorbeam · corrodedSHIP 3235 CORROSION FLOOR BEAM -Y1162.5 LOCATED AT LEVEL FR68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1761969)SDR DALA2021032301710Floorbeam · corrodedSHIP 3254 CORROSION FLOOR BEAM -Y1292 AT LEVEL OF FR20 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER SRM A320 51-72-11. (1761690)SDR SWIA2021071459576Floorbeam · corrodedL/H F.S. 310 CROSSBEAM SUPPORT FITTING CORRODED AT FLOOR LEVEL. (C-CHECK RO 7/10/2021) REMOVED AND REPLACED L/H F.S. 310 CROSSBEAM SUPPORT FITTING IAW CRJ700 SRM 51-42-21-001-001-A01SDR REXA2021041300201Angle · corrodedFS 280.00 FWD ""J"" ANGLE IS CORRODED BETWEEN LBL9 AND RBL9. REMOVED AND REPLACED FWD 280 ""J"" ANGLE IAW CRJ 900 SRM 51-42-06-001-001 AND 51-40-11-001-001-A01. WVAC EMP #603145SDR DALA2021032301701Floorbeam · corrodedSHIP 3255 CORROSION FLOOR BEAM -Y450 LOC AT LEVEL FR 68 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED BEAM PER SRM A320 51-72-11. (1760993)SDR CALA2021032200358Floorbeam · corrodedB757-53-3-0551 FLOOR BEAM 377.7 BL0-LBL24 HAS CORROSION. REPAIRED FLOORBEAM AT BS 377.7 BL0-LBL59 PER B757 SRM 53-00-51 R EPAIR 10 DWG 141N5161 REV AG. REF HAECO GSO MECH V932840, INSP QC418/V901877SDR SWIA202158227Floorbeam · cracked*COCKPIT RBL12 FLOOR BEAM APPEARS TO HAVE A CRACK AT THE FS280 ATTACH FLANGE (C-CHECK RO 5/20/2021) COMPLIED WITH REPAIR OF COCKPIT RBL12 FLOOR BEAM REF CRJ-700 SRM 53-11-43-201-003-A01. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWIA202158044Floorbeam · crackedRH COCKPIT FLOORBEAM CRACKED AT FS274, RBL12. (C-CHECK RO 5/3/2021) REMOVED DAMAGED FLOORBEAM SEGMENT AT RBL 12 FS 274 AND REPLACED WITH NEW FLOORBEAM SEGMENT REF CRJ 900 SRM 53-11-43-201-003-A01 TYPE IV, SRM 51-42-06-001-001-A01 & SRM 51-42-21-001-001-SDR SWAA2021040757078Floorbeam · corrodedCORROSION AT FWD CARGO AFT BULKHEAD FLOOR SUPPORT STA 500D; S-25L TO S-25R; WL 154. / REMOVED AND INSTALLED NEW FLOOR SUPPORT AT FWD CARGO STA 500D BETWEEN STR 25L AND 25R IAW B737-700 SRM 51-40-02-0G-0SDR CALA2021032200351Floorbeam · corrodedB757-53-0579 FLOOR BEAM UPPER SURFACE BS1640 RBL48 - RBL54 HAS L IGHT CORROSION AROUND FASTENER HOLES. REF HAECO GSO NR 9281256 REPAIRED FLOORBEAM AT BS 1640 PER B757 SRM 53-00-51 REPAIR 8.SDR DU4R2021031900045Floorbeam · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND A CRACK INDICATION IN FLOOR BEAM LAYER OF MAIN CABIN, FLOOR BEAM LBL 24.82, HOLE AT BS 660 4TH OPEN HOLE. S/O 660004 N/R 44935SDR CALA2021031900343Floorbeam · corrodedREF AMES NR 0869. DURING PANEL INSTALL FOUND CORROSION ON FLOOR PANEL SUPPORT FRAME AT STA 1197+88 FLOOR PANEL SUPPORT FRAME BLENDED TO REMOVE CORROSION AT STA 119 7+88 ORIGINAL THICKNESS .063" MATERIAL REMOVED .030" REMAINING T HICKNESS .033". FOUND TO BE OUTSDR SWIA202158587Floorbeam · corroded* CORROSION DETECTED ON CRAWLWAY FLOOR "SUPPORT" ANGLE, ON AFT SIDE OF F.S. 280.00 BETWEEN STGR 26L AND 26R, AROUND NUT PLATE HOLES (MARKED). (C-CHECK RO 5/25/2021) REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW CRJ-900 SRM 53-11-10-001-003-A01. INSDR SWIA202158585Floorbeam · corroded*CORROSION ON FLOOR BEAM PACKER ON FS 333.00, LBL9. MARKED. (C-CHECK RO 5/25/2021) REMOVED AND REPLACED F.S.333.00 LBL9 PACKER IAW CRJ-900 SRM 51-42-06-001-001-A01.SDR SWIA202158527Floorbeam · corroded*CORROSION ON FLOOR SUPPORT BEAM BETWEEN RBL27 -RBL36, FS 333.00 (C-CHECK RO 5/25/2021) PERFORMED FLANGE REPAIR ON FLOOR SUPPORT BEAM BETWEEN RBL27 - RBL36, FS333 REF MHIRJ REO 690-53-21-1340 REV -- DATED 2021-04-05. COMPLIED WITH TASK CARD 51-900-1002-SDR SWIA202158524Floorbeam · cracked*COCKPIT FLOOR BEAM RBL9 IS CRACKED AT FS 280.00. (C-CHECK RO 5/25/2021) INSTALLED NEW COCKPIT FLOOR BEAM SECTION @ RBL9 FS280.00 PER CRJ-900 SRM 53-11-43-201-003-A01, NO FURTHER DEFECTS NOTED. / COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKYSDR SIMA20210318002Floorbeam · corrodedRH CENTER FLOOR BEAM CORRODED JUST AFT OF FR 89. CORROSION LEVEL 2-C/A-REMOVED AND REPLACED RH CENTER FLOOR BEAM JUST AFT OF FR 89 IAW EMB 175 SRM 51-40-08, 51-40-02 AND 51-43-03.SDR CALA2021031900337Floorbeam · corrodedREF AMES NR 0867. DURING PANEL INSTALL FOUND CORROSION ON STATIO N 1197 FLOOR PANEL SUPPORT FRAME REMOVED CORROSION STA 1197+110 ORIGINAL THICKNESS .063" REMOVED .050" FOUND TO BE OUT OF LIMITS REPLACED INNER CHORD IAW B767 SR M 53-00-07 AND BOEING DWG 146T106SDR DU4R2021031800043Floorbeam · corrodedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND EXFOLIATED CORROSION IN MAIN CABIN FLOOR STRUCTURE LATERAL CROSSBEAM AT BS 767, RBL 35.00. S/O 660004 N/R 44993SDR DALA2021031801554Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON CABIN FLOOR BEAM AROUND STA 303, LBL 55. REPAIRED PER SRM 53-00-51. (LP 1758084)SDR SWIA202158521Floorbeam · corroded* LBL9 FLOOR BEAM HAS CORROSION ON THE UPPER SURFACE AT APPROXIMATELY FS1033 (MARKED). (C-CHECK RO 5/25/2021) REPAIRED LBL9 FLOOR BEAM AT APPROXIMATELY FS1033 BY REPLACING DAMAGED SECTION FROM FS1027 TO FS1039. REF: CRJ-900 SRM 53-00-41-201-001-A03, FIGSDR SWIA202158520Floorbeam · corroded* FS1015 CROSSBEAM HAS CORROSION ON RH OUTBOARD END UPPER SURFACE (MARKED). (C-CHECK RO 5/25/2021) REMOVED CORROSION AND APPLIED REINFORCEMENT ANGLE TO RH OB LOCATION OF FS1015 REF REO 690-53-61-986 REV -- 2021-04-06. COMPLIED WITH TASK CARD 51-900-1002SDR SWAA2021040656275Floorbeam · crackedPASSENGER CABIN FLOOR SUPPORT ANGLE CRACKED AT B.S. 540 L.BL. 1'.(51-004) / REMOVED AND REPLACED FLOOR SUPPORT AT MAIN CABIN; STA 540; LBL 1' TO LBL 23' REF B-737-700 SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 DW: 143A5240.SDR SWAA2021040656277Floorbeam · crackedPASSENGER CABIN FLOOR SUPPORT CRACKED AT B S. 540 R.BL.1'.(51-005) / REMOVED AND REPLACED FLOOR SUPPORT AT MAIN CABIN; STA 540; RBL 1' TO RBL 23' REF B-737-700 SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 DW: 143A5240.SDR AALA202103309016Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM STA 987, LEFT BUTT LINE 64. REMOVED CORROSION BY OVERSIZED DRILLING AND INSTALLED REINFORCING REPAIR PER EA 326386.SDR FDEA202103170686Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1661 LBL 50-60 MAIN DECK FLOORBOARD CORRODED AT NUTCLIPS REMOVED AND REPLACED FLOORBOARD SUPPORT AT STA 1661 LBL50-60 PER DWG 3853 AND SRM51-31-01 VOLIISDR CALA2021031900332Floorbeam · corrodedB757-53-3-0551 FLOOR SUPPORT BS 338 LBL24 HAS CORROSION. REF H AECO GSO NR 9281263SDR DU4R2021031700042Floorbeam · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND MAIN CABIN UNDER FLOOR BEAM HAS EVIDENCE OF CORROSION AT BS 887 LBL 70.53 - RBL 70.53. S/O 660004 N/R 44834SDR SWIA202158116Floorbeam · corrodedA-BAY FLOOR SUPPORT ANGLE ON AFT SIDE OF FS280 CORRODED AS MARKED (C-CHECK RO 5/3/2021) REMOVED AND REPLACED CORRODED A BAY FLOOR SUPPORT ANGLE REF. CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-13-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01.SDR SWIA202158003Floorbeam · corrodedFS 280 COCKPIT FLOOR PANEL SUPPORT ANGLE CORRODED AS MARKED (C-CHECK RO 5/3/2021) REMOVED AND REPLACED FS280 FLOOR PANEL SUPPORT ANGLE IN REF DWG CC670-33052, REV G, CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01. SEE CONTINUATION CSDR SWAA2021032256211Floorbeam · crackedFWD CARGO BREAK ASSY-PNL AT BS 537 CRACKED. CRACK MEASURES APPOXIMATELY 1.5IN. (P/N 143A5240-36) REF IPC 53-42-11-66 ITEM 330 / REMOVED AND REPLACED FWD CARGO BREAK ASSY AT BS 537 PER SRM 51-40-02
Back to JASC 5315