SDR SWIA2019123147490Floorbeam · cracked* FS 280 LBL 9 INBOARD AND OUTBOARD CLIPS ARE CRACKED AT UPPER RADIUS (C-CHECK) RO 12/27/2019 COMPLIED WITH BOMBARDIER REO. PERFORMED CUT OUT AT LBL 9.0 INBOARD AND OUTBOARD BEAM. REMOVED ALL BURRS AND SHARP EDGES. FABRICATED, DRILLED AND LOCATED 2EA CLIP P/SDR REXA2019112631673Floorbeam · corroded"INITIAL INSPECTION: CORROSION ON FLOOR PANEL SUPPORT ANGLE STA FS 280AT CABIN PAX (W1) (TCI 53-10-219)
"SUMMARY: ON NRC. 00162 CORROSION LEVEL 2, FLOOR PANEL SUPPORT ANGLE STA FS=280 WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01
"SDR DALA2019111546709Floorbeam · corroded(AIRCRAFT 6715, L/P 1358663) CORROSION ON BEAM STA 365 BTW LBL 5 TO RBL 30. CORRECTIVE ACTION: CORROSION LEVEL 2: BEAM STA 365 BTW LBL 5 TO RBL 30 WAS REPAIRED PER B757-200 SRM 53-00-51 REPAIR 10 FIG 201.SDR SWAA2022051165606Floorbeam · deformed(SKYLINE DTIP) REPAIR ON CENTER SECTION LOWER BEAM CHORD AT BS 545 TO BS 550; RBL 41.5 TO RBL 42.5 REQUIRES REPLACEMENT. (REF ESR #19-05466) / REPAIRED CENTER SECTION LWR BEAM CHORD B.S 545 RBL 41.5 TO RBL 42.5 IAW EA 1-757-16680 REV IR AND ATS ER 19-05678 REVSDR FDEA2020011640128Floorbeam · corrodedMAIN CARGO DECK, STA1346 RBL105 CORROSION (MARKED) WORKED ACOMPLISHED ON N/R 664 AND 884 PER EA. 1-5710-T0351898SDR SWAA2019112539091Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR BOARD SUPPORT CORRODED AT BS. 807, RBL 14. / REPAIRED FLOOR TRACK IAW SRM.SDR DALA2019112116810Floorbeam · corrodedCORROSION LEVEL: 2 FLOOR BEAM FOUND CORROSION AT RBL 88, STA 325. C/W ERA 582360-14. (LP 1355039)SDR FDEA201911268087Floorbeam · crackedCENTER CARGO COMPT: APPROX STA 1741 , CENTERLINE CARGO STOP. UNDER THE CARGO STOP THE FLOOR BEAM IS CRACKED.(UNDERSIDE OF STOP) REMOVED DAMAGED FLOOR BEAM IN CTR CARGO AT STA 1741. INSTALLED NEW FLOOR BEAM SECTION AND REPAIR PARTS PER SRM 51-31-01-0G.SDR DALA2019112276832Floorbeam · damagedDRAWING 16D12N00101, SHEET 3, FOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+44 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350862)SDR DALA2019112276831Floorbeam · damagedFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+22 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350854)SDR DALA2019112146814Floorbeam · damagedFOUND MISDRILLED FASTENER HOLE ON FLOOR BEAM AT STA 654A+88 RBL 33.00 & LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350872)SDR DALA2019112136812Floorbeam · corrodedFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 522 LBL 33.00 REPAIRED AS PER SRM 53-00-51 (LP 1350766)SDR DALA2019112136811Floorbeam · corrodedFOUND MISDRILLED FASTENER HOLE ON FLOOR BEAM AT STA 522 RBL 33.00 REPAIRED AS PER SRM 53-00-51. (LP 1350761)SDR DALA2019111406673Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+66 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350869)SDR DALA2019111406672Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+66 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350864)SDR DALA2019111406671Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+44 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350858)SDR DALA2019111406670Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A+22 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350857)SDR DALA2019111436664Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 654A RBL 33.00 & LBL33.00, SRM 53-00-51. (LP 1350852)SDR DALA2019111436663Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 632 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350846)SDR DALA2019111436662Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 632 RBL 33.00 . REPLACED PER SRM 53-00-51. (LP 1350843)SDR DALA2019111436661Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 610 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350821)SDR DALA2019111436660Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 610 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350808)SDR DALA2019111436659Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 588 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350798)SDR DALA2019111436658Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 566 LBL 33.00. REPAIRED PER SRM 53-00-51. 9LP 1350783)SDR DALA2019111436657Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 566 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350780)SDR DALA2019111436656Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 544 RBL 33.00 & LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350769)SDR DALA2019111436655Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 500 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350757)SDR DALA2019111436654Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 500 RBL 33.00 REPAIRED PER SRM 53-00-51. (LP 1350751)SDR DALA2019111436653Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 478 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350698)SDR DALA2019111436652Floorbeam · mechanic errorDURING MIDLIFE MOD FOUND MISDRILL FASTENER HOLE ON FLOOR BEAM STA 478 RBL 33.00. REPAIRPED PER SRM 53-00-51. (LP 1350695)SDR DALA2019111436651Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 434 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350694)SDR DALA2019111436650Floorbeam · mechanic errorFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 434 LBL 33.00. REPLACED PER SRM 53-00-51. (LP 1350683)SDR DALA2019111436649Floorbeam · damagedFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 412 LBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350677)SDR DALA2019111436648Floorbeam · damagedFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 412 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350670)SDR DALA2019111486640Floorbeam · damagedFOUND MISDRILL FASTENER HOLE ON FLOOR BEAM AT STA 588 RBL 33.00. REPAIRED PER SRM 53-00-51. (LP 1350786)SDR DALA2019111296588Floorbeam · corroded(LOG 1351261) DURING INSPECTION FOUND CORROSION ON BEAMS STA 986 STA LBL 60 AND RBL 60 AT W2. BEAM STA 986 STA LBL 60 AND RBL 60 AT W2 WAS REPAIRED PER B-737/800 ERA 582867-14 REV ORIG AND ETI-37-19-343 REV 1.SDR SWIA2019121846987Floorbeam · crackedF.S. 280.00 I/B AND O/B FLOOR BEAM ATTACHMENT ANGLES ARE CRACKED AT RBL 9.0. (C-CHECK) RO 12/14/2019 REMOVED AND REPLACED I/B AND O/B FS 280.00 FLOORBEAM ATTACHMENT ANGLES AT RBL 9.0 IAW CRJ 200 SRM. SEE CONTINUATION CARD FOR DETAILS.SDR SWAA2019112639169Angle · corrodedAFT CARGO FLOOR SUPPORT RAIL REPAIR CORRODED AT BS. 767+6, LBL 12.5 ON INSIDE OF ANGLE. / R&R ANGLE IAW SRM AND EA.SDR FDEA2019111572905Floorbeam · corrodedFORWARD WET AREA CORROSION STA 345 FLOORBEAM UPPER SURFACE OF UPPER CHORD, FORWARD AND AFT FLANGES, APPROX LBL 5 - LBL 23 AND LBL 56. BLENDED OUT CORROSION AREA AT FLOORBEAM STA 345 UPPER SURFACE OF UPPER CHORD AND FOUND OUT OF LIMITS AT LBL 5 AND LBL 23 IAW SDR SWAA2019111838873Floorbeam · corrodedAFT CARGO FLOOR SUPPORT RAIL CORRODED AT BS. 727D+5, LBL 3, ON LOWER SURFACE AROUND NUT PLATES. / REPAIRED RAIL IAW EA & SRM.SDR SWAA2019111138753Floorbeam · corrodedFORWARD CARGO COMPARTMENT FLOOR SUPPORT AT AFT BULKHEAD CORRODED BS. 500I, BETWEEN LBL 24 TO RBL 24. / R&R FLOOR SUPPORT ANGLE IAW SRM & DWG.SDR IPXA2019110878746Floorbeam · wornINSPECTION TYPE:C14 MAIN CARGO DECK BEAMS AT STA 879 HAVE DEEP WEAR MARKS FROM WRONG HARDWARE INSTALLED IN FLOORBOEARD SUPPORT. DOT # 29-211. REMOVED DISCREPANT FILLER, WHICH HAS WEAR MARKS, FORM EXISTING REPAIR. 2. FABRICATE AND INSTALL NEW FILLER PER EA 757-SDR SWAA2019120239285Floorbeam · corrodedFLOOR BEAM UPPER SURFACE CORRODED AT BS. 947, BETWEEN RBL 9 TO RBL 15. / REPAIRED FLOOR BEAM UPPER CHORD IAW SRM.SDR SWAA2019112739192Floorbeam · corrodedFLOOR BEAM CORRODED AT BS. 986, BETWEEN RBL 28 TO RBL 51, UPPER SURFACE. / REPAIRED FLOOR BEAM IAW SRM.SDR AALA201911139028Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT FLOOR SUPPORT AT BS 500I BETWEEN LBL 24 AND RBL 24. REPLACED FLOOR SUPPORT PER SRM 51-40-02.SDR SWIA2019110646721Floorbeam · corroded* LH FLOOR BEAM LBL27 CORRODDED ON OUTBD LIP AT FASTNERS FROM APROX FS 621 TO AROX 580 MARKED. (C-CHECK) RO: 11/05/2019 THE CORRODED L/H FLOOR BEAM AT LBL 27, OUTBD LIP AT FASTENERS FROM APPROX. F/S 580 TO F/S 621 HAD 4EA NUTPLATES REMOVED, THE CORROSION BLESDR SWAA2022040613472Floorbeam · corroded***CORROSION*** ON 294 FLOORBEAM BETWEEN RBL 12-51 ON UPPER SURFACE; WL 208. (MARKED) / REPAIRED BS 294 FLOORBEAM IAW ER#19-05573 REV IR & EA#1-753-36031 REV IR.SDR R61A2019112351313Floorbeam · crackedFWD FUSELAGE FLOOR STRUCTURE ANGLE FOUND CRACKED. R&R'D ANGLE IAW 51-41-02SDR R61A201911235312Floorbeam · crackedFWD FUSELAGE FLOOR STRUCTURE AT FR 12 BL 0, CROSSBEAM ANGLE FOUND CRACKED. R&R'D ANGLE I.A.W. SRM 51-41-02SDR FDEA2019110752872Floorbeam · crackedMAIN CABIN STA 1640 AT APPROX RBL 45 FLOOR BEAM SUB-STRUCTURE IS CRACKED VIEWED FROM BELOW (STREAMER ATTACHED) REPAIRED STA 1640 @ RBL 45 FLOOR BEAM SUB STRUCTURE STRAP PER B757 53-00-51-2R