JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2019061433704Floorbeam · corrodedAFT PASSENGER COMPARTMENT FLOOR STRUCTURE FLOOR BEAM NUTPLATE HOLE CORRODED AT BS. 986, RBL 43. / REPAIRED FLOOR BEAM PER SRM.SDR DALA2019053003321Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM -Y1292 LOC FROM FR 12 TO FR 24 FWD GALLEY AREA (1 EA). REPLACED FLOORBEAM -Y12925 LOC FROM FR 12 TO FR 24 FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG #D53110920 ISSUE D RELEASE DATE:07-DEC -19 DWG #53112812. MEASURE OF COSDR REXA2019062790978Strap · corrodedRH F.S. 559 FLOOR SUPPORT STRAP CORRODED BETWEEN RBL27 AND RBL 42. LOCATED AND DRILLED NEW SERVICEABLE STRAP P/N 601R31025-29 IAW SRM 51-40-11, INSTALLED NEW SERVICEABLE STRAP IAW SRM 51-42-06 AND SRM 51-42-13SDR AALA201906039027Floorbeam · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON FLOOR BEAM AT FR66, -Y1292; (1.75"X 1.75" X .046" DEEP AREA OF CORROSION). REMOVED AND REPLACED FLOOR BEAM P/N D53472090010000 IAW SRM 51-51-42 AND DRG D5347209001.SDR CALA2019053100872Floorbeam · corroded[B737-06-3-0049] AFT CABIN FLOORBEAM BS 986.5 BETWEEN RBL 16 AND RBL 45 HAS CORROSION AS MARKED.(REF AAR NR 99835788) REMOVED CORROSION AT FLOORBEAM BS 986.5 BETWEEN RBL 16 AND RBL 45. FOUND OUT OF LIMITS IAW SRM 51-10-02 & EC/RA 53-21-01330. INSTALLED NEW FLOSDR DALA2019052903306Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM -Y765 LOC FROM FR 12 TO FR 24 FWD GALLEY AREA (1 EA). REPLACED FLOORBEAM -Y765 LOC FROM FR 12 TO FR 24 FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG #D53112812. MEASURES OF CORROSION AREA L=2.562" W=0.387" D=0.045".SDR WVER2019070133Floorbeam · corrodedLBL9 FLOORBEAM IS CORRODED BETWEEN FS 597 AND FS 613.SDR WVER2019070132Floorbeam · corrodedRBL9 FLOORBEAM IS CORRODED AT FS 615.SDR DALA2019052903344Floorbeam · corrodedSHIP 682 CORROSION / TRANSVERSE FLOORBEAM / STA:STA 1681 AND BTW LBL 24 TO LBL 60 / CORROSION AND MISSING NUT PLATE AT W4. CORRECTIVE ACITON: SUMMARY IN REF OF NRC 00262 REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REPAIRED PER ERA 568446-14 REV ORIG AND ETI.SDR REXA2019052800741Floorbeam · corrodedINITIAL INSPECTION: CORROSION ON FLOORBEAM LBL9.00 BTW FS1015.00 - FS1051.30 AFTER BAGGAGE BAY (C3)[SM]. SUMMARY: CORROSION LEVEL 2. FLOORBEAM LBL9.00 BTW FS1015.00 - FS1051.30 AFTER BAGGAGE BAY, WAS REPAIRED PER SRM 53-00-41-201-001-A03. NEW BEAM WAS DRILLED SDR DALA2019052903305Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM -Y254 LOC FROM FR 12 TO FR 24 FWD GALLEY AREA (1 EA). REPLACED FLOORBEAM -Y254 LOC FROM FR 12 TO FR 24 FWD GALLEY AREA (1 E/A) ASPER SRM 51-72-11 AND DRAWING #53110920000.SDR DALA2019052903304Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM +Y1292 LOC BTW FR 12 TO FR 24 FWD GALLEY AREA (1 EA). REPLACED FLOORBEAM +Y1292 LOCATED BTW FR12 TO FR24 FWD GALLEY AREA ASPER SRM 51-72-11 AND DRAWING #D53112812. MEASURES OF CORRODED AREA L=0.986", W= 0.848", D=0.060".SDR DALA2019052903302Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM +Y765 LOC FROM FR 12 TO FR 24 AT FWD GALLEY AREA (1 EA). REPLACED FLOORBEAM ON FWD GALLEY AREA LOC BTW FR12 TO FR 24+ Y765 AS PER SRM 51-42-11-001, 51-72-11-401 AND DWG #D53110920. MEASURE OF REWORK AREA ARE: L=1.726", W=SDR DALA2019052903300Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM -Y1162.5 AT AFT GALLEY AREA (1 EA) (SSI 534147). REPLACED FLOORBEAM -Y1162.5 AT AFT GALLEY AREA (1EA)AS PER SRM 51-72-11 AND DRAWING #D53472780. MEASURE OF CORROSION AREA ARE: L=1.300" W= 1.067", D=0.061".SDR DALA2019052903299Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM +Y1162.5 AT AFT GALLEY AREA (1 EA) (SSI 534147). REPLACED FLOORBEAM +Y1162.5 AT AFT GALLEY AREA (1EA) AS PER SRM 51-72-11 AND DWG #D5347278. MEASURE OF CORROSION AREA ARE L=1.300", W=1.067" D=0.061".SDR DALA2019052903298Floorbeam · corrodedCORROSION LEVEL: 2 CORROSION FLOORBEAM +Y1732 LOC BTW FRAME 65 TO FRAME 66 AT AFT GALLEY AREA (1 EA) (SSI 534147). REPLACED FLOORBEAM +Y1732 LOCATED BTW FRAME 65 TO FRAME 66 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG 53474250 ISSUE V RELEASE DATE: 11FEB04 SDR REXA2019052700740Floorbeam · corrodedINITIAL INSPECTION: CORROSION ON FLOORBEAM LBL27.00 BTW FS1000.00 - FS1051.30 AFTER BAGGAGE BAY (C3)[SM]. SUMMARY OF NRC 306: LEVEL CORROSION 2. FLOORBEAM LBL27.00 BTW FS1000.00 - FS1051.30 AFTER BAGGAGE BAY, WAS REPAIRED PER SRM 53-00-41-201-001-A03.SDR AALA201907019065Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOORBEAM AT BS 986.5 BETWEEN LBL 50 AND RBL 50. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-4.SDR REXA2019062760977Floorbeam · crackedLH FS 484.00 FLOOR SUPPORT INTERCOSTAL ANGLE CRACKED AT LBL 27. REMOVED AND REPLACED LH FS 484.00 INTERCOSTAL ANGLE AT LBL 27 IAW CRJ200 SRM 51-42-21. REMOVED TAPE. WVAC 712.SDR FDEA2019052861172Floorbeam · corrodedMAIN CABIN R/H SIDE FLOOR T CHORD AT RBL.45 STA.324. REMOVED CORR. IN MAIN CABIN T CHORD STA.324 RBL.45. ORIG MAT.120, LOSS .042, REMAIN. .078 OUT OF LIMITS, CUT OUT DAMAGED SECTION OF T CHORD FROM RBL.32 TO RT OB END AND INSTALLED REPAIR SECTION.IAW B757 SDR FDEA2019052861170Floorbeam · corrodedMAIN CABIN STA.365 BETWEEN RBL.15 - RBL.47 CORROSION ON FLOOR BEAM T CHORD. UPON FURTHER EVALUATION FOUND CORR. ON "T" CHORD STA.365 RBL.15 - RBL.47 TO BE OUT OF LIMITS DUE TO CORR. BEING ON EXISTING REPAIR. REMOVED AND REPLACED "T" CHORD SECTION OF EXISTISDR FDEA2019052861171Floorbeam · corrodedMAIN CABIN STA.1200 BETWEEN BL.0- LBL.24.5 FLOOR BEAM T CHORD CORRODED. REMOVED CORR. IN MAIN CABIN FLOOR BEAM STA.1200 BL.0 -LBL.24.5. ORIG. THICKNESS .125" LOSS .028 ,REMAIN. .093 OUT OF LIMITS , CUT OUT DAMAGED SECTION OF UPPER CAP OF FLOOR BEAM RBL.10 SDR AALA201906039022Floorbeam · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON FLOOR BEAM AT FR 66, Y1292, RBL 50.5 P/ND5347209001100 (.5"L X.375"W X.038"D CORROSION). REMOVED AND REPLACED FLOOR BEAM IAW SRM 51-51-42 AND DRAWING D53472090.SDR REXA2019062750965Floorbeam · crackedFS 280 FLOOR SUPPORT BEAM PREVIOUS REPAIR CLIPS CRACKED INBD AND OB. LOCATED, DRILLED, AND INSTALLED I/B AND O/B FS 280.00 CLIPS PN 601R3113-57 AT LBL 9.0 IAW CRJ 200 SRM 51-42-21, 51-40-11, TR 51-42 AND RE-MOVED TAPE. WVAC 712SDR REXA2019052750946Floorbeam · crackedFS 280 BEAM UPPER J-ANGLE PREVIOUS REPAIR ANGLE CRACKED OUTBD OF RBL 9. INSTALLED NEW ANGLE P/N 601R-53-137-6 AT FS 280 IAW CRJ 200 SRM 51-42-06.WVAC 769SDR IPXA2019062194518Floorbeam · crackedINSPECTION TYPE:3CFWD LOWER CARGO FLOOR BEAM IS CRACKED AT STA. 6-70 ABOVE LONGERON 43 RT.REPAIRED CRACKED FWD LOWER CARGO FLOOR BEAM AT STA. Y=6-70, X=-57.5 AND Z=-98 IAW MD-11 SRM 53-40-51 REPAIR 1, FIGURE 202. (MAJOR)SDR R61A201906110593Floorbeam · corrodedCORROSION-AFT WET AREA FR. 90 I/B FLOOR SPLICE HAS CORROSION AS MARKED. REMOVED AND REPLACED AFT WET AREA FR.90 R.HAND I/B FLOOR SPLICE REF. EMB 175 SRM 51-40-08, SRM 51-40-02, SRM 51-23-04 SEE EAMS W/O H6837 SN 301 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVSDR R61A201906110592Floorbeam · corrodedCORROSION-AFT WET AREA FR. 90 R.HAND O/B FLOOR SPLICE. REMOVED AND REPLACED AFT WET AREA FR.90 R.HAND O/B SPLICE REF. EMB 175 SRM 51-40-08, SRM 51-40-02, SRM 51-23-04. SEE EAMS W/O H6837 SN 299 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR R61A201906110591Floorbeam · corrodedCORROSION-AFT WET AREA FR. 89 R.HAND I/B FLOOR SPLICE HAS CORROSION AS MARKED. REMOVED AND REPLACED AFT WET AREA FR.89 R.HAND FLOOR SPLICE REF. EMB 175 SRM 51-40-08, SRM 51-40-02, SRM 51-23-04. SEE EAMS W/O H6837 SN 37 FOR WORK DETAILS. AIRCRAFT REMAINS IN SDR DALA2019052403215Floorbeam · corroded(LOG 1088977) DURING INSPECTION FOUND CORROSION FLOORBEAM LOC . STA 344 LBL 10 AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FLOORBEAM BS 344 LBL 10A AT PASSENGER CABIN ASPER ER/A 578344-14, REVISION ORIGINAL AND PRI NO 578344-14 REVISION 0 AND 1.SDR DALA2019052503181Floorbeam · corrodedCORROSION FLOORBEAM +Y1162.5 LOCATED BETWEEN FR68 TO FR 69 AT AFT GALLEY AREA, REPLACED FLOORBEAM Y1162.5 LOC BTW FR68 TO FR69 AT AFT GALLEY AREA ASPER SRM 51-72-11 AND DRAWING #D534725000.SDR DALA2019052503180Floorbeam · corrodedCORROSION FLOORBEAM +Y1227 LOCATED BETWEEN FR 66 TO FR 68 AT AFT GAL LEY AREA, REPLACED FLOORBEAM +Y1227 LOCATED BTW FR 66 TO FR 68 AT AFT GALLEY AREA (1EA) ASPER SRM 51-72-11 AND DWG D53472000.SDR DALA2019052503179Floorbeam · corrodedCORROSION FLOORBEAM -Y1225 LOCATED BETWEEN FR66 TO FR 68 AT AFT GALLEY AREA, REPLACED FLOORBEAM Y-1225 LOC BTW FR66 TO FR68 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DRAWINGD53472000.SDR SWAA2022030906113Splice · corroded***CORROSION*** ON FLOOR PANEL SUPPORT SPLICE AT AFT CARGO BAY BS727D+6 LBL20 TO RBL20 WL155. MARKED / REMOVED AND REPLACED FLOOR PANEL SUPPORT SPLICE IAW AMM 25-52-10-000-801 59366U 6/15/19 AND SOPM 20-50-01 AND DWG 146A9401 IN AFT CARGO BAY BS727D+6 LBL20 TOSDR CA190527007Floorbeam · corroded(CAN) FS280 FLOOR SUPPORT CORROSION REMOVAL LBL9.0 TO RBL9.0 (TC# 20190527007)SDR SWAA2019062654113Floorbeam · crackedFLOORBEAM CRACKED AT BS. 540, BETWEEN BL 0 TO RBL 25. / R & R FLOORBEAM TEE IAW AMM & DWG.SDR SWAA2019062534093Floorbeam · crackedFLOORBEAM CRACKED AT BS 540, BETWEEN BL 0 TO LBL 25. R&R THE FLOORBEAM IAW SRM AND DWG.SDR SWAA2019062534092Floorbeam · corrodedFLOOR SUPPORT CORRODED AT BS. 540, BETWEEN LBL 25 TO LBL 45. R&R FLOOR SUPPORT IAW SRM, DWG AND AMM.SDR SWAA2019061833822Floorbeam · corrodedFORWARD CARGO BAY ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE CORRODED AT BS. 500D, BETWEEN LBL 23 TO RBL 21. / R&R ANGLE IAW SRM AND DWG.SDR SWAA2019061833793Floorbeam · corrodedBEAM UPPER CHORD CORRODED AT BS. 986, BETWEEN BL 0 TO RBL 12. / REPAIRED CHORD IAW SRM.SDR SWAA2019060733435Floorbeam · corrodedFORWARD CABIN FLOOR BEAM TOP SURFACE CORRODED AT BS 328, RBL 45. / REPAIRED FLOOR BEAM IAW SRM.SDR SWAA2019060733431Floorbeam · corrodedAFT CARGO BAY FLOOR PANEL SUPPORT CORRODED AT BS. 887, BETWEEN LBL 21 TO RBL 21. R&R SUPPORT IAW SRM & DWG.SDR AALA201906039021Floorbeam · corrodedAIRCRAFT IN BASE VISIT: AREA OF CORROSION AROUND MOUNT HOLE 1"X1"X .064" DEEP ON FLOOR BEAM FR65, -Y765. REMOVED AND REPLACED FLOOR BEAM P/N D5347209000300 IAW SRM 51-42-11.SDR AALA201906039020Floorbeam · corrodedAIRCRAFT IN BASE VISIT: 4 AREAS OF CORROSION EACH MEASURES APPROX. 1"X1" WITH A MAX DEPTH OF .080" AT ONE LOCATION ON FLOOR BEAM AT FR68, -Y765; P/N D5347219320000. REMOVED AND REPLACED FLOOR BEAM IAW SRM 51-42-11.SDR AALA201905319021Floorbeam · corrodedAIRCRAFT IN BASE VISIT: FLOORBEAM HAS L=1.0", W=1.3" & D=.064" AREA OF CORROSION. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-00 AND DRAWING D53472816.SDR DALA2019052403264Floorbeam · corrodedSHIP 682 CORROSION ON FLOOR BEAM STA 345 LBL= 8, 12. CORRECTIVE ACTION: SUMMARY OF NRC 00258 CORROSION WAS REPAIRED PER ER/A 578237-14 REV ORIG AND ETI-57-19 -073 REV. 2. (1088433)SDR DALA2019052303163Floorbeam · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 67 TO FR 68 -Y 765 AT AFT GALLEY AREA, REPLACED FLOORBEAM -Y765 LOC. BTW FR67 TO FR68 AFT GALLEY AREA ASPER SRM 51-72-11 AND DRAWING # D53472000.SDR DALA2019052303162Floorbeam · corrodedCORROSION FLOORBEAM -Y1162.5 LOCATED FR68 TO FR69 AT AFT GALLEY AREA, REPLACED FLOORBEAM 1162.4 LOC FR68 TO FR69 AT AFT GALLEY AREA. AS PER SRM 51-72-11 AND DRAWING # D53472000.SDR SWAA2022030906094Beam · corroded***CORROSION*** 986 FLOOR BEAM UPPER SURFACE HAS CORROSION LBL 41-LBL 45 / CORROSION ON BS 986 FLOOR BEAM UPPER SURFACE AT LBL 41- LBL 45 WAS REPAIRED IAW EA 1-A53-8241 REV 3SDR CA190522010Floorbeam · corroded(CAN) FS621 FLOOR SUPPORT ANGLE FOUND TO BE CORRODED. CORROSION HAS BEEN BLENDED AT 2EA LOCATION BETWEEN LBL 9 & LBL 27. (TC# 20190522010)
Back to JASC 5315