SDR SWAA2019062634181Floorbeam · corrodedFLOOR BEAM UPPER SURFACE CORRODED AT BS. 986, RBL 45. / REPAIRED FLOOR BEAM PER EA AN ER.SDR ASAA2019061029616Floorbeam · corrodedAFT MAIN CAIN FLOOR SUPPORT STRUCTURE AT FRAME 68 APPROX. LBL 48 IS CORRODED GROUNDED - YES. REPAIRED SUPPORT STRUCTURE IAW A319 SRM53-41-14. REMOVED AND REINSTALLED WEB IAW A319 SRM 51-42-11 & DWG # D53480019SDR R61A2019060522580Floorbeam · crackedCOCKPIT FLOOR STRUCTURE AT FR 12 BL 0, ANGLE FOUND CRACKED. COCKPIT FLOOR STRUCTURE AT FR 12 BL 0 ANGLE REPLACED IAW SRM 51-41-01. A/C REMAINS OUT OF SERVICE.SDR R61A2019060522578Floorbeam · crackedCOCKPIT FLOOR STRUCTURE AT FR 12 LBL 36, ANGLE FOUND CRACKED. COCKPIT FLOOR STRUCTURE AT FR 12 LBL 36 ANGLE REPLACED IAW SRM 51-41-01. PSE 53-10-26. A/C REMAINS OUT OF SERVICE .SDR SWAA2019060433259Floorbeam · corrodedFLOOR BEAM UPPER CHORD CORRODED AT BS. 270, BETWEEN LBL 11 TO RBL 11. / REPAIRED FLOOR BEAM PER EA.SDR AALA201905239019Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD WET AREA FLOORBEAM BETWEEN FR 12 AND FR 24 AT -Y1292. REPLACED FLOORBEAM PER SRM 51-72-11.SDR REXA2019062710980Strap · corrodedLH FS 559 FLOOR SUPPORT STRAP CORRODED BETWEEN LBL27 AND LBL42. LOCATED AND DRILLED NEW SERVICEABLE STRAP PN 601R31025-291AW IAW SRM 51-40-11, INSTALLED NEW SERVICEABLE STRAP IAW CRJ 200 SRM 51-42-06 AND SRM 51-42-13.SDR REXA2019062710979Floorbeam · corrodedLH FLOOR SUPPORT ANGLE ATTACHED TO FS 621 PRESSURE BULKHEAD CORRODED BETWEEN LBL27 AND LBL42.
REPAIRED IAW BOMBARDIER REO 601R-53-61-7009.SDR REXA2019052710953Floorbeam · corrodedRT FLOOR BEAM CAP CORRODED AT FS 559 INBD SIDE OF RBL9. REPAIRED AREA IAW REO 601R-53-41-2483.SDR AALA201905229012Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FORWARD WET AREA FLOORBEAM BETWEEN FR 12 AND FR 24 AT -Y1292. REPLACED FLOORBEAM PER SRM 51-72-11.SDR REXA2019060419790Floorbeam · corroded"AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTI
ON PLATE SUPPORT IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERV
ICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
"
"LEVEL CORROSION 2. PROTECTION PLATE SUPSDR FDEA201905191096Floorbeam · crackedMAIN CABIN FLOOR STRUCTURE-STA.580 STUB FLOORBEAM AT LBL 45.5 HAS A CRACK ON AFT FLANGE AS SEEN FROM FWD CARGO COMPARTMENT. COMPLIED WITH EA F- 5310-T0347001 P1, FUSELAGE - MAIN FRAME - STA. 580 FLOORBEAM SPLICE SEGMENT UPPER AFT FLANGE CRACK REPAIR.SDR REXA2019060418789Floorbeam · corroded"INITIAL INSPECTION: CORROSION ON FLOOR BEAM [ UPPER/AFT FLANGE ] IN ST
A. FS= 280 AND 11LBL AT PAX CABIN FWD WET AREA. (W1) (CPAX) TCI: 53-10
-219
"
"SUMMARY:SUMMARY: LEVEL CORROSION 2. FLOSDR REXA2019060417788Floorbeam · corroded"INITIAL INSPECTION: CORROSION ON FLOOR PANEL SUPPORT ANGLE OF ACCESS P
ANEL 221ALF IN STA. FS= 280 BETWEEN 11 LBL/RBL AT COCKPIT. (CPIL) TCI
53-10-219
"
"SUMMARY: AREA WAS MEASURED AND FOUND WISDR REXA2019051600725Floorbeam · corrodedSUPPLEMENTAL INFORMATION FS 621/ LBL27 FLOORBEAM FITTING IS CORRODED. REPAIRED FLOORBEAM.SDR SWIA2019070346030Floorbeam · corrodedFLOORBEAM CORRODED AROUND FLOOR BOARD SCREW HOLES. FS409+6 €“ FS409+118, RBL9. (C-CHECK) RO: 07/02/2019 A NEW FLOORBEAM CAP WAS INSTALLED IAW SRM AND REO.SDR AALA201906031005Floorbeam · corrodedAIRCRAFT IN BASE VISIT: FWD CARGO: FLOORBOARD SUPPORT ANGLE HAS CORROSION ON UPPER SURFACE AT STA. 500I BETWEEN STRS. 25L-25R. INSTALLED FWD CARGO: FLOORBOARD SUPPORT ANGLE PART #143A9485Y35 AT STA. 500I BETWEEN STRINGERS. 25L-25R PER AARD 51-00-05-1 AND BOINGSDR R61A2019060150571Floorbeam · crackedWHILE AIRCRAFT WAS OUT OF SERVICE FOR HEAVY CHECK, FLOOR SUPPORT BRACKET FOUND CRACKED AT CENTER FUSELAGE III.SDR KCSA201905151128Floorbeam · corrodedCORROSION ON MAIN DECK FLOOR BEAM AT STA 2280 RBL 42 AFT SIDE.SDR KCSA201905151124Floorbeam · corrodedEVIDENCE OF CORROSION ON TOP OF MAIN DECK FLOORBEAM STA 2160 LBL 12.SDR SWAA2019061833838Floorbeam · corrodedAFT CARGO BAY FLOOR PANEL SUPPORT CORRODED AT BS. 887, BETWEEN LBL 9 TO RBL 21. / R&R FLOOR SUPPORT PER SRM AND DWG.SDR REXA2019061730871Floorbeam · crackedINITIAL INSPECTION: CRACKED LONGITUDINAL FLOOR BEAM RBL 12 AND FS 280. BELOW COCKPIT. CRACKED LONGITUDINAL FLOOR BEAM RBL 12 AND FS 280. BELOW COCKPIT WAS REPAIRED PER REO: 690-53-11-1141.REV.SDR REXA2019061730870Floorbeam · crackedINITIAL INSPECTION: CRACKED LONGITUDINAL FLOOR BEAM LBL 12 AND FS 280. BELOW COCKPIT.
CRACKED LONGITUDINAL FLOOR BEAM LBL 12 AND FS 280. BELOW COCKPIT WAS REPAIRED PER REO: 690-53-11-1141.REV.SDR SWAA2019061433745Floorbeam · crackedFLOOR PANEL SUPPORT CRACKED AT BS. 540, BETWEEN BL 0 TO LBL 24.5. / R&R SUPPORT PER SRM & DWG.SDR SWIA2019060545949Floorbeam · corrodedFLOOR BEAM CAP @ FS559+55 RBL 9 IS CORRODED. (C-CHECK) RO: 06/02/2019 REPAIRED FS559+55 RBL 9 FLOORBEAM CAP IAW REO. C/W ALL STEPS OF PERMANENT REPAIR.SDR ABXA2019060313108Floorbeam · corrodedCORROSION ON UPPER T-CHORD OF AFT LOWER COMPARTMENT FLOOR FRAME AT FUSELAGE STATION 1219. THE T-CHORD WAS REPLACED. THE AIRPLANE WAS GROUNDED.SDR ABXA2019060313107Floorbeam · corrodedCORROSION ON UPPER T-CHORD OF AFT LOWER COMPARTMENT FLOOR FRAME AT FUSELAGE STATION 1263. THE T-CHORD WAS REPLACED. THE AIRPLANE WAS GROUNDED.SDR ABXA20190513073Floorbeam · corrodedCORROSION ON THE UPPER CHORD OF THE FLOORBEAM AT FUSELAGE STATION 1540, STRINGER 33L. THE CHORD WAS REPAIRED. THE AIRPLANE WAS GROUNDED.SDR SCNA20190513049Floorbeam · corrodedSTATION 986.5, IN FRONT OF R2, CORROSION ON THE "T" CAP OF STAATION ABOUT 3 FEET INBOARD, MARKED WITH STREAMER A5/038. REPAIRED FLOORBEAM @ STATION 986.5 FROM L-2 TO R-2 DOOR.SDR SCNA20190513045Floorbeam · corrodedUNDER FLOOR PANEL 241ABF, STATION 986.5, THERE ARE FOUR SCREW HOLES THAT HAVE A LIGHT CORROSION ON TOP OF STATION, MARKED A5/034. T-CAP REPAIR COMPLETED.SDR AALA201906209018Floorbeam · damagedAIRCRAFT IN BASE MAINTENANCE: AFT WET AREA FLOOR BEAM SPLICE HAS ELONGATED HOLE AT FR 68 BETWEEN +Y1162 AND +Y1225. REPLACED SPLICE PER SRM 51-72-11.SDR AALA201905309009Floorbeam · corrodedAIRCRAFT IN BASE VISIT: CORROSION FLOORBEAM +Y765 BTW FR 12 TO FR 24 FWD GALLEY AREA (1 EA), L=0.657'' W=0.621'' D=0.048'' CORRODED AREA. REPLACED FLOORBEAM +Y765 BTW FR12 TO FR24 FWD GALLEY AREA IAW SRM51-72-11 AND DWG NO.D53112812, D53115054.SDR AALA20190512009Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT BS 947.5 AND RBL 50. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-5.SDR AALA201905289020Floorbeam · corrodedAIRCRAFT IN BASE VISIT: CORROSION FLOORBEAM +Y1292 BTW FR12/FR24 AT FWD GALLEY AREA (1EA) L=1.507", W=0.902", D=0.065". REPLACED FLOORBEAM +Y1292 BTW FR 12/ FR 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG # D53112812.SDR AALA201905229016Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD WET AREA FLOORBEAM BETWEEN FR 12 AND FR 24 AT -Y765. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201905139045Strap · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOORBEAM STRAP AT BS 348 AND BL 0. REPLACED STRAP PER SRM 53-00-51-2R-13.SDR AALA20190510004Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOORBEAM AT BS 947.5 AND LBL 50. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-5.SDR AALA20190510003Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOORBEAM AT BS 986 BETWEEN LBL 26 AND LBL 41. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-4 AND EA 293227.SDR VNAA2019051099904Floorbeam · corrodedRBL 9 FLOORBEAM, I/B FLOOR SUPPORT FLANGE, IS CORRODED AT FS 591 TO FS 621 AROUND NUT PLATE PULL RIVETS. C/A: INSTALLED NEW SERVICEABLE FLOORBEAM AT RBL 9 BETWEEN FS 574-605 IAW REO #601R-53-61-3780 REV. A DATED 2011-07-15.SDR VNAA2019051099903Floorbeam · corrodedLBL 9 FLOORBEAM, I/B FLOOR SUPPORT FLANGE, IS CORRODED AT FS 595 AROUND NUT PLATE PULL RIVETS. C/A: INSTALLED NEW SERVICEABLE FLOORBEAM AT LBL 9 BETWEEN FS 574-605 IAW REO #601R-53-61-3780 REV. A DATED 2011-07-15.SDR VNAA2019051099902Floorbeam · corrodedRBL9 FLOORBEAM HAS CORROSION AROUND FLOOR NUTPLATE HOLES BETWEEN FS409 AND FS409+128. C/A: REMOVED AND REPLACED RBL9 FLOORBEAM CAP IAW SRM 51-40-11, 51-42-06, 51-42-21 AND REO 601R-53-31-1010 DATED 2019-05-02.
.SDR VNAA2019051099901Floorbeam · corrodedLBL9 FLOORBEAM HAS CORROSION AROUND FLOOR NUTPLATE HOLES BETWEEN FS409 AND FS409+128. C/A: REMOVED AND REPLACED LBL9 FLOORBEAM CAP IAW SRM 51-40-11, 51-42-06, 51-42-21 AND REO 601R-53-31-1010 DATED 2019-05-02.SDR SWAA2019053133207Floorbeam · crackedFLOOR SUPPORT CRACKED AT BS. 540, BETWEEN BL 0 TO LBL 24.5. R&R FLOOR SUPPORT IAW SRM.SDR KCSA201905091123Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 580 RBL 24 (MAIN DECK).SDR KCSA201905091121Floorbeam · corrodedM/D FLOORBEAM UPPERCORD SEVERAL HOLES CORROSION STA 1540 RBL 44.SDR KCSA201905091120Floorbeam · corrodedEVIDENCE OF CORROSION ON MAIN DECK FLOORBEAM UPPER CHORD STA 640 LBL 100 TO 115.SDR KCSA201905091119Floorbeam · corrodedMD-33, MAIN DECK FLOORBEAM UPPER CHORD IS CORRODED STATION 2040, LBL APPRX 36 TO APPRX LBL 80 AROUND FASTENER HOLES.SDR KCSA201905091117Floorbeam · corrodedMD-31, MAIN DECK FLOOR, STATION 2100, LBL APPRX 72 TO LBL APPRX 85 UPPER CHORD AND FLOOR PLATE IS CORRODED UPPER AND LOWER SURFACESSDR KCSA201905091115Floorbeam · corrodedEVIDENCE OF CORROSION ON FLOORBEAM TOP SURFACE AT STA 2100 LBL 104 TO LBL 97.SDR KCSA201905091114Floorbeam · corrodedEVIDENCE OF CORROSION ON TOP SURFACE OF FLOORBEAM AT STA 2140 LBL 85 TO 94.