JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR KCSA201905091112Floorbeam · corrodedMD-29 MAIN DECK FLOOR STATION 2040, LBL 63, UPPER CHORD OF FLOORBEAM IS CORRODED ALL THE WAY OVER TO LBL 115.SDR KCSA201905091111Floorbeam · corrodedMD-20 AFT PIT, MAIN DECK FLOORBEAM UPPER CHORD NUT CLIPS ARE CORRODED AND POSSIBLY BENEATH NUT CLIPS, STATION 1940, LBL APPRX 30 TO LBL 40SDR KCSA201905091110Floorbeam · corrodedEVIDENCE OF CORROSION ON MAIN DECK FLOORBEAM UPPER CHORD STA 1800 RBL 98.SDR SWAA2022030967969Floor Support · crackedFLOOR PANEL SUPPORT IS CRACKED AT B.S. 540; B.L. 0-L .B.L 24.5; W.L. 208.1. / REMOVED AND INSTALLED A NEW FLOOR PANEL SUPPORT AT B.S 540 BL0- LBL 24.5 WL 208.1 IAW SRM 51-40-05; SRM 51-40-02; DWG 143A0060SDR SWAA2022030967970Floor Support · crackedFLOOR PANEL SUPPORT IS CRACKED AT B.S. 540; B.L. 0-R .B.L 24.5; W.L. 208.1. / REMOVED AND INSTALLED A NEW FLOOR PANEL SUPPORT AT B.S 540 BL0- RBL 24.5 IAW SRM 51-40-05; SRM 51-40-02 ; DWG 143A0060SDR SWAA2022030967974Track · crackedCRACK ON ACB FLOOR TRACK IN RADIUS OF FRAME ATTACH TAB STA 727E WL 155 LBL 17 / CLEANED REPAIR AREA OF FOD PER AMM 20-60-02-100-801.SDR CA190521019Fitting · corroded(CAN) LBL 27 FLOOR BEAM END FITTING BLEND (TC# 20190521019)SDR AALA201905289014Floorbeam · corrodedAIRCRAFT IN BASE VISIT: CORROSION FLOORBEAM -Y1292 BTW FR12/FR24 AT FWD GALLEY AREA (1EA) L=1.507"X W=1.1875"X D=0.0490" CORRODED AREA. REPLACED FLOORBEAM -Y1292 BTW FR12/FR24 AT FWD GALLEY AREA (1EA) AND FASTENERS IAW SRM 51-72-11, 51-42-11 AND DRAWING D53115SDR AALA201905239025Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOORBEAM BETWEEN FR 64 AND FR 65 AT +Y1292. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201905229020Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD WET AREA FLOORBEAM BETWEEN FR 12 AND FR 24 AT +Y1292. REPLACED FLOORBEAM PER SRM 51-72-11.SDR SWAA2019051332581Floorbeam · crackedFLOOR SUPPORT CRACKED AT BS. 540, BETWEEN BL 0 TO LBL 24. R&R FLOOR SUPPORT IAW SRM AND DWG.SDR SWAA2019051032519Floorbeam · damagedCOCKPIT FLOOR CREASED ALONG FLOORBEAM BETWEEN BS. 254.5 TO BS. 259.5, LBL 15.33. REPAIRED FLOORBEAM IAW EA.SDR SWAA2019051032518Floorbeam · damagedCOCKPIT FLOOR CREASED ALONG FLOORBEAM BETWEEN BS. 254.5 TO BS. 259.5, LBL 4.33. REPAIRED FLOORBEAM IAW EA.SDR SWAA2022030967966Floorbeam · corrodedCORROSION ON 986 FLOOR BEAM UPPER TEE CHORD SURFACE LBL 43 / BLENDED CORROSION ON BS 986 FLOOR BEAM UPPER CHORDE AT LBL 43; 1.7' X 1' X .030' FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 REPAIRED PER EA 1-53-8241 REV 3SDR SWAA2022030967965Floorbeam · corrodedCORROSION ON 986 FLOOR BEAM UPPER TEE CHORD SURFACE RBL 27 TO 43. / BLENDED CORROSION ON BS986 FLOOR BEAM UPPER CHORD RBL 27 TO RBL 43; DEEPEST BLEND AT RBL36 MEASURING 2' X 1.2' X .041' ALL FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 REPAIRED PER EA 1-A53SDR SWAA2022030977929Crease Beam · crackedCREASE BEAM WEB IS CRACKED AT LIGHTNING HOLE; BS 469 RBL 65; WL 208 / REMOVED CRACK ON CREASE BEAM WEB LIGHTNING HOLE EDGE AT BS 469; RBL 65; WL 208 IAW SRM 53-30-13-1A-1 STEP 4A (1)(A) & SRM 51-10-02-0G-0. AFTER EVALUATE REWORK AREA IT WAS FOUND WITHIN LIMITSSDR ASAA2019050629327Floorbeam · corrodedAFT WET AREA BS 986 FLOORBEAM AT APPROX. RBL 36 HAS AREAS OF CORROSION. GROUNDED - YES. REPAIRED 986 FLOORBEAM UPPER CHORD IAW SRM 53-00-01-2R-1, W-1" O-.150" R-.116" L-1" D-.034".SDR FDEA201905061008Floorbeam · crackedSTA 580 FLOORBEAM CRACKED - LBL45 , UPPER CORD AFT FLANGE. COMPLIED WITH EA F- 5310 - T0346588 P1 TITLE : FUSELAGE MAINFRAME STA.580 FLOORBEAM SPLICE SEGMENT UPPER AFT FLANGE CRACK REPAIR.SDR ASAA2019050629312Floorbeam · corrodedAFT WET AREA BS 986 FLOORBEAM HAS AREA OF CORROSION ON FWD FLANGE AT LBL3. GROUNDED - YES. REPAIRED FLOORBEAM IAW SRM 53-70-51-2R-6W-1" O-.150", R-.107", L-2" D-.043".SDR DALA2019050602810Floorbeam · corrodedCORROSION FLOORBEAM -Y765 LOCATED FR64 TO FR66 RT SIDE AT AFT GALLEY AREA (1 EA). REPLACED FLOORBEAM -Y765 LOCATED FR64 TO FR66 RT SIDE AT AFT GALLEY AREA (1E/A) AS PER SRM 51-72-11 AND DRAWING #14N00031. MEASURE OF CORROSION ARE L=0.455" W=0.270", D=0.047".SDR RJEY2019052800006Floorbeam · corrodedCORROSION FLOORBEAM LOC. AT LEVEL OF -Y189 APPROX BTW FR20 TO FR21 IN PASSENGER CABIN.SDR CA190527002Floorbeam · corroded(CAN) INSPECTION FOUND CORROSION DAMAGE ON CROSS BEAM LOCATED AT FS1000.00 AND RBL41.00. (TC# 20190527002)SDR SWAA2022030848098Splice Strap · corrodedAFT CARGO BAY FLOOR SPLICE STRAP AT BS772 HAS CORROSION LBL10 TO RBL10 WL156 / RECEIVED NEW ACB FLOOR SPLICE STRAP FOR B.S 772 ON PO# 717082 NEW PART WILL BE INSTALLED ON CUST.CARD #753-140-00-02Y.SDR SWAA2019052933152Floorbeam · corrodedFLOOR STRUCTURE FLOOR BEAM CORRODED AT BS. 344, BETWEEN RBL 9 TO LBL 20. REPAIRED T-CAP IAW EA.SDR N6WA2019050202Floorbeam · crackedRT 280 FLOORBEAM CRACKED. COMPLETED RT 280 FLOORBEAM REPAIR.SDR REXA2019050100653Floorbeam · corrodedINITIAL INSPECTION : CORROSION ON FLOORBEAM 27LBL BTW FS=1006 TO FS=1041 AT REAR FUSELAGE INTERNAL STRUCTURE (FUS) ( TCI:53-30-310). FLOORBEAM WAS REPAIRED PER SRM 53-00-42-201-001-A01.SDR AALA201905099020Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLOORBEAM BETWEEN FR 12 AND FR 24 AT +Y254. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201905089026Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM BETWEEN FR 64 AND FR 66 AT +Y1292. REPLACED FLOORBEAM PER SRM 51-72-11.SDR KCSA201905011104Floorbeam · corrodedCORRODED CLIP NUTS AND HARDWARE ON MAIN DECK FLOORBEAM UPPER CHORD STA 1640 RBL 80.SDR RJEY2019052800005Floorbeam · corrodedCORROSION ON FLOORBEAM -Y1292 BTW FR16 AND FR20 FLOOR STRUCTURE PAX CABIN FWD GALLEY AREA.SDR RJEY2019052800002Floorbeam · corrodedCORROSION FLOORBEAM -Y765 AT LEVEL OF FR20 FLOOR STRUCTURE PAX CABIN FWD GALLEY AREA.SDR DALA2019043002794Floorbeam · corroded(LOG 1052710) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE STA. 986.5 AND RBL 34 AND RBL 43 AT AFT GALLEY AREA. REMOVED AND REPLACED RILLER ON FLOORBEAM BS 986.5 RBL 43 AS PER INSTRUCTION REPAIR PARTS STEP 5 AND EVALUATED REWORKED AREA ON RBL 34 ASPER INSSDR KCSA201904301103Floorbeam · corrodedCORROSION ON MAIN DECK FLOOR BEAM AT STA 860 RBL 78SDR KCSA201904301101Floorbeam · corrodedMAIN DECK FLOOR FRAME UPPER CHORD HAS CORROSION @ STA 2360 RBL 12 (NOTE: FOUND TO BE FLOOR BEAM)SDR KCSA201904301097Floorbeam · corrodedEVIDENCE OF CORROSION ON TOP OF MAIN DECK FLOOR BEAM AT STA 1740 RBL 91SDR KCSA201904301096Floorbeam · corrodedMD-26, MAIN DECK FLOOR RBL APPRX 12 TO RBL APPRX 32 FLOOR BEAM LOWER SURFACE OF UPPER CHORD HAS MULTIPLE SMALL AREAS OF CORROSION STATION 2360SDR KCSA201904301095Floorbeam · corrodedSTA 2260 / RBL 81 M/D FLOOR BOARD BEAM UPPER CORD - CORROSIONSDR NACA2019070800052Floorbeam · corrodedDISCREPANCY: STA 986 MAIN CABIN RBL 24-45 FLOORBEAM HAS CORROSION. CORRECTIVE ACTION: STA 986 MAIN CABIN RBL 24-45 FLOORBEAM REPAIRED IAW AEI EO 8512 REV IR SEE FAA FORM 8110-3 FOR APPROVAL FOR THE REPAIR ACCOMPLISHED TO BS986 UPPER FLOORBEAM CAP.SDR NACA2019070800040Floorbeam · corrodedSTA 320, BL48 RT, R1 DOOR ENTER WAY. FLOORBEAM TOP CAP CORRODED AROUND ANCHOR NUTS. STA 328 BL48 RT, R1 DOOR ENTRY WAY FLOORBEAM TOP CAP REPAIRED IAW SRM REV 119 CH 53-10-51.SDR NACA2019070800039Floorbeam · corrodedSTA 344 BL 30-25 RH FLOOR BEAM TOP LAP REPAIRS IAW AEI EO 8326 REV IR AND B737-300 SRM REV 119 CH 53-10-51, SEE ATTACHED FAA 8110-3 APPROVAL.SDR FDEA201904290967Floorbeam · corrodedCORROSION FOUND STA 1681 RBL 13 FLOORBEAM UNDER LIP OF THE TOP "T" CAP. COMPLIED WITH EA F-5310-T0346723 P1. TITLE: FUSELAGE-MAINFRAME - CORROSION ON STA 1681 FLOORBEAM UPPER CHORD, REINFORCING REPAIR, BL 0 TO RBL 45.7.SDR R61A201905110479Doubler · corrodedRT FLOORBEAM DOUBLER CORRODED AT FR90 AS MARKED. REMOVED CORRODED RT FLOORBEAM DOUBLER AT FR90. LOCATED, DRILLED, AND APPLIED ALODINE TO NEW RT FLOORBEAM DOUBLER CORRODED INSTALLED RT FLOORBEAM DOUBLER AT FR90 PER REF SRM 51-40-08 APPLIED PRIMER TO RT FLOORBEASDR SWAA2019050732352Floorbeam · corrodedFLOORBEAM VERTICAL FLANGE CORRODED AT BS. 986, RBL 20. REPAIRED FLANGE PER SRM AND EA.SDR LR7A2019042901511Floorbeam · crackedDURING SCHEDULED C-13 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND THE FS180.5 FLOOR SUPPORT BEAM CRACKED AT RBL20, WL169. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM, CH. 51-60 & 51-70. NR# 2120.SDR QXEA2019050100198Floorbeam · crackedFLOORBEAM AT FSX 683.00,Y-30 AT FLOOR BOARD SUPPORT BRACKET IS CRACKED. REMOVED FLOORBEAM @ FSX683.00 Y30 IAW SRM 51-40-07-02-01. INSTALLED NEW SECTION OF FLOORBEAM @ FSX683.00 Y30 LT IAW SRM 51-40-07-02-01 & 51-42-05-02-01.SDR A6WA201904306592Floorbeam · crackedPRESSURE FLOOR INTERCOSTAL AT FS 484 RBL 27-RBL 36 IS CRACKED AT O/B SIDE REPAIRED PRESSURE FLOOR INTERCOSTAL AT FS 484 RBL 27 - RBL 36 IAW ASAP EA#: AWAC-CRJ253-01224 REV IRSDR A6WA201904306591Floorbeam · crackedPRESSURE FLOOR INTERCOSTAL AT FS 484 LBL27-LBL36 IS CRACKED O/B SIDE REPAIRED PRESSURE FLOOR INTERCOSTAL AT FS 484 LBL27-LBL36 IAW ASAP EA# AWAC-CRJ253-01225 REV 1RSDR C77A2019042860001Floorbeam · damagedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE ON CONDITION REPLACEMENT OF A DAMAGED OR PREVIOUSLY REPAIRED RH FLOOR BEAM P/N 170-65669-004 (Y = +260) BETWEEN FRAMES 86 AND 89. THE DAMAGED STRUCTURE WILL BE REPLACED BY USING EMBRAER PRODUCTISDR C77A202002250021Floorbeam · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE ON CONDITION REPLACEMENT OF A DAMAGED OR PREVIOUSLY REPAIRED RH FLOOR BEAM P/N 170-65669-004 (Y = +260) BETWEEN FRAMES 86 AND 89. THE DAMAGED STRUCTURE WILL BE REPLACED BY USING EMBRAER PRODUCTISDR SWIA2019060545944Floorbeam · corrodedFLOOR SUPPORT BRACKET MOUNTED TO RIGHT HAND FRAME FS319.70 IS CORRODED. (C-CHECK) RO: 06/02/2019 REMOVED AND REPLACED WITH NEW FLOOR SUPPORT BRACKET AT FS319 IAW SRM.
Back to JASC 5315