What was found
AFT WET AREA BS 986 FLOORBEAM HAS AREA OF CORROSION ON FWD FLANGE AT LBL3. GROUNDED - YES. REPAIRED FLOORBEAM IAW SRM 53-70-51-2R-6W-1" O-.150", R-.107", L-2" D-.043".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA BS 986 FLOORBEAM HAS AREA OF CORROSION ON FWD FLANGE AT LBL3. GROUNDED - YES. REPAIRED FLOORBEAM IAW SRM 53-70-51-2R-6W-1" O-.150", R-.107", L-2" D-.043".