SDR SWAA2019030830452Floorbeam · crackedFLOORBEAM CRACKED AT BS 328 RBL 20 NEAR FLOOR BOARD SCREW HOLE. REPAIRED FLOORBEAM PER SRM.SDR CALA2019030100313Floorbeam · corrodedFLOOR SUPPORT BEAM AT STA 985 LBL46 HAS CORROSION ACCOMPLISHED REPAIR AT FLOOR SUPPORT BEAM BS 986.5 & LBL46 AS PER EC/RA 5310-05874 REV - & SRM 53-70-51 REPAIR 4 ALT 7 FIG 204 ( FOR DETAILS SEE PARTIAL WORK) REF NR 9583653.SDR CALA2019030100312Floorbeam · corrodedFLOOR SUPPORT ANGLE AT BASE OF R2 DOOR HAS SPOTS OF CORROSION ACCOMPLISHED REPAIR AT FLOOR SUPPORT BECAUSE OF R2 DOOR AT BS 986.5 RBL. 20 TO RBL 50 AS PER EC/RA. 5310-05874 REV - AND SRM 53-70-57 REPAIR 4 FIG 204 CELL 1 PO#1251084 ( FOR DETAILS SE PARTIAL WORKSDR DALA2019022801275Floorbeam · crackedCRACK FLOOR SUPPORT ON AFT BULKHEAD IN STA Y=655 UNDER SIDE TIE TRACK RH AND LH. (CCD). NRC 00335: CRACK FLOOR SUPPORT ON AFT BULKHEAD IN STA Y=655 UNDER SIDE TIE TRACK RH AND LH WAS REPLACED PER B717-200 SRM 51-41-01 AND 51-41-02. (LP #0962703)SDR SWAA2022030366100Beam · corroded***CORROSION*** CORROSION ON BS 986 FLOOR BEAM UPPER SURFACE AROUND FLOOR BOARD HOLE LBL 45 / REPAIRED CORROSION ON BS 986 FLOOR BEAM UPPER CHORD SURFACE PER EA 1-A53-8241 REV 3 OF LBL 45SDR SWAA2019050132125Floorbeam · corrodedFLOORBEAM CORRODED AT BS. 344, BETWEEN BL 0 TO LBL 45. REPAIRED FLOORBEAM PER ER AND EA.SDR AALA201903064011Floorbeam · corrodedCORROSION FOUND ON THE AFT GALLEY FLOORBEAM ANGLE AT BS 950 BETWEEN LBL 26 - LBL 49. REPLACED THE THE FLOORBEAM ANGLE IAW RD 51-00-05-1.SDR CA190226001Floorbeam · corroded(CAN) DURING HMV INSPECTION (425-ZL-121-GVI-10000-1) CORROSION (TYPE 3) WAS FOUND BEYOND ALLOWABLE LIMITS ON THE UPPER FLOOR BEAM AT FRAME 17. REFERENCE W.O 33423366 NR00185. TO BE REPAIRED IAW SRM (TC# 20190226001)SDR DALA2019022801351Floorbeam · corrodedCORROSION LEVEL: 2 AFT CARGO FLOORBEAM CORRODED STA 1175, RBL 12. INSTALLED REPAIRED ANGLE. (LP 0962345)SDR CA190227001Floorbeam · corroded(CAN) 4 EA BETWEEN FS610 - FS621 FLOOR BEAM END FITTINGS HAVE CORROSION AT NUT-PLATE LOCATIONS (TC# 20190227001)SDR C77A2020030400009Floorbeam · corrodedDURING BASIC CHECK AT EAMS, CORROSION WAS FOUND ON THE FOLLOWING FORWARD WET AREA
FLOOR STRUCTURE: LH FLOOR SILL P/N 170-03275-005, LH FLOOR SUPPORT P/N 170-13633-001,
LH FLOOR SILL P/N 170-05662-001, LH CENTER FLOOR BEAM P/N 170-07298-003.
REFERENCE ETD201SDR SWAA2019032531039Floorbeam · corrodedFLOORBEAM UPPER FLANGE CORRODED AT BS 986, BETWEEN LBL 29 TO LBL 43. REPAIRED FLANGE IAW SRM AND EA.SDR SWIA2019031945655Floorbeam · corrodedCARGO, FLOORBEAM CORRODED FS619 €“ FS621 LBL27. (C-CHECK) RO: 03/18/2019 REMOVED CORROSION ON CARGO FLOORBEAM AT FS619- FS621 LBL27 IAW SRM AND REO.SDR R61A201902240198Floorbeam · corrodedWHILE IN HEAVY CHECK - CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 LT BEAM Y=-10.748" AS MARKED NEXT TO RIVET. REPLACED CENTER FUSELAGE III WET AREA 53-23 LT BEAM Y=-10.748", REF SRM 51-40-08.SDR R61A201902240195Floorbeam · corrodedWHILE IN HEAVY CHECK - CORROSION ON LT FLOORBEAM BETWEEN FR 90-90A AS MARKED. REMOVED AND REPLACED LT FLOORBEAM.SDR R61A201902240194Floorbeam · corrodedWHILE IN HEAVY CHECK - CORROSION ON RT FLOORBEAM BETWEEN FR 87-89 AS MARKED. REMOVED AND REPLACED RT FLOORBEAM P/N 170-65669-004 REF SRM 51-40-08, 51-23-04, 51-40-08.SDR R61A201902240193Splice · corrodedWHILE IN HEAVY CHECK - CORROSION ON LT BEAM SPLICE AT FR 90. REMOVED AND REPLACED LT BEAM SPLICE.SDR SWIA201904035721Strap · corrodedCORROSION ON THE R-H FLOOR SUPPORT STRAP AT FS559.00, RBL27 TO RBL45. (C-CHECK) RO: 04/01/2019 COMPLIED WITH ALL STEPS OF REPAIR OF R/H FLOOR SUPPORT AT FS 559.00 RBL27 TO RBL45, IAW REO.SDR COEA2019042519805Floorbeam · corrodedWO 193437 NR 100024 HEAVY CHECK COE/MAJOR REPAIR: FLOORBEAM 33 HAS LEVEL 2 CORROSION ON UPPER SURFACE BETWEEN LH OUTBOARD SEAT TRACK AND RH INBOARD SEAT TRACK. CORRECTIVE ACTION: FLOORBEAM SPLICE REPAIR PER SRM 530000-300-834-A01.SDR COEA2019022101805Floorbeam · corrodedWO 193437 NR 100032 HEAVY CHECK COE/MAJOR REPAIR: FLOORBEAM 39 HAS LEVEL 2 CORROSION BETWEEN L/H INBOARD SEAT TRACK AND AFT CARGO DOOR THRESHOLD. CORRECTIVE ACTION: FLOORBEAM FLANGE REPAIR PER SRM 530000-300-849-A01.SDR REXA2019022100209Floorbeam · corrodedAWR; HIDDEN CORROSION; DURING REMOTION OF FLOOR PANEL SUPPORT ANGLE TO REMOVE CORROSION, A BEAM WAS FOUND CORRODED [ IN REFERENCE NRC 00136 ]: CORROSION ON FLOORBEAM FWD FACE [ INBD SIDE AND NEAR UPPER/AFT FLANGE ] IN STA. FS= 280, 2RBL AND 3.5RBL AT PAX CABINSDR AALA201903018006Floorbeam · corrodedCORROSION FOUND ON THE AFT GALLEY FLOORBEAM, BS 947, BL 0 - LBL 51. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-2R-5, AND EA 290501.SDR AALA201902262005Floorbeam · corrodedCORROSION FOUND ON THE FORWARD CARGO FLOORBEAM, BS 500I, BETWEEN STRINGERS 25L AND 25R. REPLACED THE FLOORBEAM IAW SRM 51-10-2.SDR FDEA2019022600503Floorbeam · corrodedMAIN CARGO DECK, STA 1281.5, RBL 47.125 TO LBL 47.125, FLOOR BOARD SUPPORT HAS COROSSION/EXFOLIATION PRIMARILY CLIP NUT HOLES. REPLACED DAMAGED FLOOR SUPPORT (FX AEA0187-9) AT STA 1281.5 RBL 47.125 TO LBL 47.125 REF SRM 51-31-01 VOL 2 & DWG AEA 0187SDR REXA2019021900195Floorbeam · corrodedAWR; HIDDEN CORROSION; DURING REMOTION OF FLOOR PANEL SUPPORT ANGLE TO REMOVE CORROSION, A BEAM WAS FOUND CORRODED [ IN REFERENCE NRC 00136 ]: CORROSION ON FLOORBEAM FWD FACE [ INBD SIDE AND NEAR UPPER/AFT FLANGE ] IN STA. FS= 280 AND 0LBL AT PAX CABIN FWD WETSDR A6WA2019022146408Floorbeam · crackedFS 280 BEAM AFT ANGLE IS CRACKED AT LBL 9 AND RBL 9. REPAIREDSDR SWIA201904035718Floorbeam · corrodedCORROSION AT FS 280.0 FLOOR SUPPORT FROM RBL 9 TO LBL 9. (C-CHECK) RO: 04/01/2019 / REMOVED AND REPLACED FS.280 FLOOR SUPPORT FROM LBL.9-RBL.9 IAW SRM.SDR FDEA2019022860512Floorbeam · corrodedMAIN CARGO AT APPROX STA 1481 LBL75 - 105 AFTER REMOVING MYLAR TAPE AND NUT PLATES FOUND UNDER SIDE OF FLOOR SUPPORT HAS EXFOLIATION CORROSION MARKED #19 REMOVED AND REPLACED FLOOR SUPPORT, MAIN CARGO, STA 1481 LBL 75-105 IAW REF DAC DWG AEA0364, SRM 51-35SDR FDEA201902260491Floorbeam · corrodedMAIN CARGO DECK, STA 1561, BETWEEN RBL = 76 TO RBL = 100, FLOOR BOARD SUPPORT LAND CORROSION AROUND SCREW HOLES REMOVED AND REPLACED FLOORBOARD SUPPORT AT MAIN CARGO DECK STA-1561, BETWEEN RBL=76 TO RBL=100, REF DOUGLAS DRWG NFA6398 AND SRM-51-33-01, VOL-ISDR FDEA201902160490Floorbeam · corrodedMAIN CARGO DECK, STA 1561, APPROX RBL=60, FLOOR BOARD SUPPORT HAS EXFOLIATING COROSSION. REMOVED AND REPLACED FLOORBOARD SUPPORT AT MAIN CARGO DECK STA-1561, APPROX RBL=60, REF DOUGLAS DRWG NFA6398 AND SRM-51-33-01, VOL-II.SDR AALA2019030649006Floorbeam · corrodedCORROSION FOUND ON THE FORWARD GALLEY FLOORBEAM. FRAME 16, +Y765. REPLACED THE FLOORBEAM IAW SRM 51-72-11.SDR AALA2019030649003Floorbeam · corrodedCORROSION FOUND ON THE AFT GALLEY FLOORBEAM, FRAME 70, -Y765. REPLACED THE FLOORBEAM IAW SRM 51-72-11.SDR A6WA2019021846401Floorbeam · corrodedFS280.00 BEAM CORRODED FROM LBL9 TO RBL9. REPAIRED BEAM IAW REO 601R-53-11-926 REV-B.SDR A6WA2019021846402Floorbeam · crackedFS280.00 BEAM FWD ANGLE CRACKED AT LBL 9 AND RBL9.SDR CALA2019021700263Floorbeam · corrodedB757-53-3-0488 FLOOR BEAM AT STA 365.25 HAS A PREVIOUS REPAIR WI TH CORROSION FROM RBL 12 TO RBL 25 ON UPPER SURFACE. REF N /R 0049140 FOUND STA 365 FLOOR BEAN UPPER CHORD OUT OF LIMITS IAW B757-200 SRM 53-00-51 FIG 101 L=3.0 W=2.0 D=.015. REMOVED EXISTING REPSDR SWAA2022030326254Splice · corroded***CORROSION*** ON ACB FLOOR T SPLICE STA 767+6 LBL 9 RBL 12 WL 169 (MARKED) / OUT OF LIMITS - NO SRM LIMITS GIVEN. RECEIVED NEW PART ACB FLOOR T SPLICE STA. 767+6; LBL 9 - RBL 12; WL 169 P.O. # 723471/1 TO BE INSTALLED ON SWA CARD NO: JPANEL-141-CLOSESDR SWAA2022030339900Floorbeam · corroded***CORROSION*** DISCREPANCY TRANSFERRED FROM LOG BOOK PAGE 066459: AFTER AFT GALLEY FLOOR PANEL REMOVED (ADJACENT AFT ENTRY DOOR); FOUND ONE FASTENER HOLE ON FLOOR BEAM CORRODED; TRANSFERRED FROM NRC G630473 / REPAIRED BS 986 FLOORBEAM IAW ATS ER 19-01813 REV SDR SWAA2022030331205Track · corrodedR BL 13.8 FLOOR TRACK HAS CORRODED NUT PLATE HOLES FROM 947 TO 887 / REMOVED AND REPLAED FLOOR TRACK PER SRM 51-40-02 REF SA-M 326 - A1133985SDR SWAA2022030331208Track · corrodedRBL 13.8 FLOOR TRACK HAS PITTING CORROSION AT NUT PLATE; APPROXIMATLEY 13' FWD OF BELT FRAME 947 / REMOVED AND REPLACED FLOOR TRACK PER SRM 51-40-02SDR SWAA2022030331206Track · corrodedLBL 3 FLOOR TRACK; VERY AFT NUT PLATE HOLE CORRODED / REMOVED AND REPLACED FLOOR TRACK PER SRM 51-40-02SDR SWAA2022030331196Channel · corrodedCORROSION AT RBL 13.8 SPLICE AT BELT FRAME 887. CORROSION IS ON INSIDE OF 'U' CHANNEL OF SPLICE. / REMOVED AND REPLACED 'U' CHANNEL AT RBL 13.8 AT STA 887. PER SRM 51-40-02 REF SA-M 326 - A1133988SDR SWAA2019030630386Splice · corrodedAFT CARGO BAY FLOOR T SPLICE CORRODED AT BS 887, BETWEEN LBL 9 TO RBL 12. R&R T SPLICE PER SRM AND DWG.SDR ASAA2019021428446Floorbeam · corrodedMAIN CABIN AFT WET AREA FLOORBEAM UPPER SURFACE AT STA 986.5 RBL 28 HAS CORROSION. GROUNDED - YES. REMOVED CORROSION ON THE UPPER SURFACE OF THE FLOORBEAM AT STA 986.5, RBL 28, ORIGIAL THICKNESS 0.150, REMAINING THICKNESS 0.130, REMOVED 0.020 FOUND TO BE OUT OSDR SWAA2022022839797Floorbeam · corrodedAFTER AFT GALLEY FLOOR PANEL REMOVED; (ADJACENT AFT ENTRY DOOR) FOUND ONE FASTENER HOLE ON FLOOR BEAM CORRODED. / TRANSFER TO LOG PAGE 0660459.SDR ASAA2019021328444Floorbeam · corrodedMULTIPLE AREAS OF CORR ON FS 986.5. GROUNDED - YES. REPAIRED 986.5 FLOORBEAM IAW SRM 53 70 51 2R 4 W 3.0 O .150 R .110 L 3.0 D .040.SDR REXA2019021300183Floorbeam · corrodedLBL 9 HAS CORROSION SPOTS ON THE O/B FLOOR PANEL LANDING BETWEEN FS 574 AND FS 605, IN THE CARGO BAY. REMOVED CORODED LBL 9 FLOORBEAM AND REPLACED WITH NEW BEAM IAW SRM 51-40-11 TR 51-42.SDR ASAA2019022738366Floorbeam · wornMAIN CABIN FLOOR STRUCTURE, STA 520 FLOORBEAM UPPER T-CAP HAS DEEP WEAR MARK APPROX. RBL 10. GROUNDED - YES. REMOVED DAMAGE TO UPPER T CAP REF: B737-800 SRM 53-00-51-2R-1. ORIGINAL MATERIAL .125 MATERIAL REMOVED 100%, LOCATED AND DRILLED REPAIR ANGLES #1 AND #SDR DALA201902154101Floorbeam · corrodedCORROSION FLOOR BEAM +Y1225 LOC.FR67 AT AFT GALLEY AREA, REPLACED FLOOR BEAM +Y1225 LOC.FR67 AT AFT GALLEY AREA PER A319 SRM 51-72-11 AND DWG D53472780SDR AALA201902153002Floorbeam · crackedCRACKED CABIN FLOORBEAM, BS 540 BETWEEN LBL 2 AND LBL 16. REPLACED THE FLOORBEAM ANGLE IAW RD 51-00-05-1, AND SRM 51-40-02.SDR SWAA2019040131221Floorbeam · corrodedFLOORBEAM AROUND HOLES TOP AND BOTTOM CORRODED AT BS 986, BETWEEN RBL 36 TO RBL 42. REPAIRED CHORD PER ER AND EA.