JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2017060400691Floorbeam · corrodedLEFT BS 280 FLOORBEAM CORRODED OUT OF LIMITS. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06, 51-42-13, & 51-42-21.SDR REXA2017060400690Floorbeam · corrodedFLOORBEAM AT BS 280, RBL 45, IS CORRODED OUT OF LIMITS. REPAIRED THE FLOORBEAM IAW REO 670-53-21-139, REV B.SDR REXA2017060400686Floorbeam · corrodedFLIGHT DECK FLOORBEAM ANGLE AT BS 280 IS CORRODED BETWEEN LBL 12 AND RBL12. OUT OF LIMITS. REMOVED AND REPLACED WITH NEW FLOORBEAM ANGLE IAW SRM 51-42-06,& 51-42-21.SDR SWAA2022012472728Floorbeam · elongatedFASTENER HOLE ELONGATED AT FLOOR BEAM 767 +6 RBL 14. / REPAIRED PER EA 1-A53-4982SDR SWAA2022012472722Strip · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION FRO STA.727E-STA.747. / REMOVED AND REPLACED SECTION OF R/H TRANSITION ANGLE BS 727C+10 - BS 767; PER SRM 53-00-53-2R-5 AND SRM 51-40-02SDR ASAA2017060121076Floorbeam · corrodedRIGHT AFT WET AREA CORRODED ON FLOORBEAM BS 986.5. ACFT GROUNDED. REMOVED AND REPLACED FLOORBEAM TEE FITTING IAW SRM 53-70-51-2R-4, REPAIR 4.SDR ASAA2017060121057Floorbeam · corrodedBS 986 FLOORBEAM FOUND CORRODED AT MULTIPLE AREAS BETWEEN RBL 40 AND RBL 54. ACFT GROUNDED. REPAIRED THE FLOORBEAM IAW SRM 53-00-51-2R-1.SDR ASAA2017060121047Floorbeam · corrodedAFT R SIDE WET AREA CORRODED ON THE FLOORBEAM BS 947.5. ACFT GROUNDED. REMOVED AND REPLACED THE FLOORBEAM TEE IAW SRM 53 70 51 2R 5, REPAIR 5.SDR ASAA2017060120994Floorbeam · corrodedLEFT AFT WET AREA CORRODED ON FLOORBEAM AT BS 986. ACFT GROUNDED. REMOVED AND REPLACED THE FLOORBEAM TEE IAW SRM 53-30-51-2R-4, REPAIR 4 FROM LBL 9.5 - 52.SDR CALA2017060201654Floorbeam · corrodedCORROSION AT BS 365 FLOORBEAM. REPLACED IAW EC/RA 5310-05536,SDR SWAA2017062114539Floorbeam · corrodedFLOORBEAM HORIZONTAL FLANGE CORRODED AT BS 1016, LBL TERMINATING END. REPAIRED FLOORBEAM IAW ER & EA.SDR ASOA201705311630Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM ANGLE BS 280 BETWEEN LBL 9 AND RBL 9. R & R THE FLOORBEAM ANGLE IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, & 51-40-11-001-001-A01.SDR ASOA201705311606Floorbeam · corrodedFS 280 FLOORBEAM CORRODED ON FWD SIDE. REMOVED AND REPLACED THE LT SIDE FLOORBEAM IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, AND 51-42-22-001-001-A01.SDR ASAA2017053021167Floorbeam · corrodedBS 270 FLOORBEAM CORRODED AT RBL 10. ACFT GROUNDED. REPAIRED THE FLOORBEAM IAW EA 700-53EA-18927.SDR V0XD20170619004Floorbeam · corrodedBS 280 FLOORBEAM LT AND RT CORRODED OUT OF LIMITS. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06, 51-42-21, 51-42-22, 51-42-13, 53-11-41 AND AMM 20-70-00.SDR ASAA2017053021091Floorbeam · corrodedBS 947 FLOORBEAM CORRODED AT MULTIPLE AREAS BETWEEN LBL 50 AND RBL 50. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS. REPAIRED IAW SRM 53-70-51-2R-5.SDR ASAA2017053020997Floorbeam · corrodedBS 986 FLOORBEAM CORRODED MULTIPLE AREAS BETWEEN LBL 50 AND 40. ACFT GROUNDED. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-W4-6, REP 6.SDR REXA2017052800671Floorbeam · corrodedCRAWLWAY FLOORBEAM ON THE BACK SIDE OF BS 280 HAD CORROSION, JUST ABOVE STRINGERS 26L AND 26R, IN THE FWD E & E BAY. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-06, AND 51-42-21.SDR YENA201705280445Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM Y 464 FRAME 66. R & R THE FLOORBEAM IAW SRM 51-42-11, AND 53-41-14, FIG 016.SDR YENA201705280429Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE LT FLOORBEAM AT FRAME 87 +5, LBL 10 ON THE UPPER SURFACE. REMOVED CORROSION, FOUND TO OUT OF LIMITS. INSTALLED DOUBLER REPAIR, TREATED, PRIMED, AND TOPCOATED IAW 51-10-03, 53-23-10, 51-23-04, 51-23-05SDR SWIA201743514Floorbeam · crackedBS 280 FLOORBEAM CRACKED AT LBL 9 AND RBL 9. REPAIRED IAW REO.SDR SWIA201743512Floorbeam · crackedFLOORBEAM ANGLE CRACKED AT BS 621 BETWEEN LBL 27 AND 36. REMOVED AND REPLACED THE FLOORBEAM ANGLE IAW REO.SDR SWAA2022012678587Angle · elongatedOUTBOARD SUPPORT ANGLE FOR INTERCOSTAL AT RBL 8; BS 986 HAS AN ELONGATED FASTENER HOLE. / REPAIRED OUTBOARD SUPPORT ANGLE FOR INTERCOSTAL AT RBL 8; B.S. 986 IAW ER 17-02794 REV IR & EA 1-753-31347 IRSDR SWAA2017061914447Floorbeam · corrodedFLOORBEAM UPPER SURFACE AROUND FASTENER HOLES CORRODED BETWEEN BS 986.5, BETWEEN RBL 40 TO RBL 47. REPAIRED FLOOR BEAM IAW EA.SDR SWAA2017061914446Floorbeam · corrodedFLOORBEAM UPPER SURFACE AROUND FASTENER HOLE CORRODED AT BS 967, RBL 28. REPAIRED FLOOR BEAM IAW SRM.SDR SWAA2017061914445Floorbeam · corrodedFLOORBEAM UPPER SURFACE AROUND FASTENER HOLE CORRODED AT BS 328, LBL 35. R&R FLOORBEAM IAW SRM.SDR SWAA2017061914444Floorbeam · corrodedFLOORBEAM UPPER SURFACE AROUND FASTENER HOLE CORRODED AT BS 328, LBL 25. R&R FLOORBEAM IAW SRM.SDR AALA201706089053Floorbeam · corrodedCORROSION ON AFT CABIN FLOORBEAM ANGLE AFT OF BS 986.5, LBL 32 TO LBL 45. REMOVED AND REPLACED FLOORBEAM ANGLE IAW 51-00-05-1 AND DRAWING 147A5700.SDR AALA20170524011Floorbeam · corrodedCORROSION ON AFT MAIN CABIN FLOORBEAM AT BS 1480, BETWEEN RBL 50 AND 70. REPAIRED IAW SRM 53-00-51-2R-1.SDR SWAA2017061314293Floorbeam · corrodedFLOORBEAM CORRODED AT BS 986, BETWEEN RBL 50 TO LBL 44. REPAIRED FLOOR BEAM IAW EA & ER.SDR REXA2017052400658Floorbeam · corrodedBS 280 FLOORBEAM UPPER FLANGE HAS CORROSION BETWEEN LBL 12 AND LBL 18. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06, 51-42-13, & 51-42-21.SDR REXA2017052400657Floorbeam · crackedBS 280 FLOORBEAM RBL 9 OTBD ANGLE IS CRACKED. REMOVED AND REPLACED THE FLOORBEAM ANGLE IAW SRM 51-42-21.SDR DALA2017052504273Floorbeam · corrodedFWD CARGO BAY FLOORBEAM CHANNEL BS 740, LBL 10 - 14 HAS CORROSION. REMOVED THE CORROSION IAW SRM 51-10-02, PARA 15. 10X MAG VERIFIED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1, DETAIL V. REMOVED THE FLOORBEAM CHANNEL IAW SRM 51-40-02, PARA 6. LOCATSDR ASOA201705241602Angle · corrodedBS 280 FLOORBEAM ANGLE IS CORRODED. REMOVED AND REPLACED THE FLOORBEAM ANGLE IAW SRM 51-40-11-001-001-A01, SRM 51-42-00-001-001-A01, AND 51-42-21-001-001-A01.SDR ASOA201705241601Floorbeam · corrodedBS 280 FLOORBEAM ANGLE IS CORRODED. REMOVED AND REPLACED THE FLOORBEAM ANGLE IAW SRM 51-40-11-001-001-A01, SRM 51-42-00-001-001-A01, AND 51-42-21-001-001-A01.SDR SWAA2017061514380Floorbeam · corrodedFLOORBEAM UPPER SURFACE CORRODED AT BS 986, BETWEEN RBL 30 TO RBL 45. REPAIRED FLOORBEAM IAW ER AND EA.SDR SWAA2017060814230Floorbeam · crackedFLOORBEAM UPPER ''T'' CAP UNDER CREASE BEAM WEB CRACKED AT BS. 294, RBL 51. REPAIRED T CAP IAW EA.SDR SWAA2017060614157Strap · corrodedAFT CARGO BAY FLOORBEAM STRAP CORRODED AT BS 767, LBL 12. REPAIRED THE STRAP IAW SRM.SDR SWAA2017060614156Strap · corrodedAFT CARGO BAY FLOORBEAM STRAP CORRODED AT BS 767, LBL 8. REPAIRED THE STRAP IAW SRM.SDR SWAA2017060614155Strap · corrodedAFT CARGO BAY FLOORBEAM STRAP CORRODED AT BS 767, RBL 8. REPAIRED THE STRAP IAW EA.SDR SWAA2017060614142Floorbeam · corrodedFLOORBEAM CORRODED AT BS 328, RBL 50. REPAIRED THE FLOORBEAM IAW SRM.SDR AALA20170524018Floorbeam · corrodedCORROSION FOUND ON THE AFT CABIN FLOORBEAM ANGLE AT BS 693, LBL 33 AND 45. REPLACED THE FLOORBEAM ANGLE IAW SRM 53-70-51-1A.SDR AALA20170523009Floorbeam · corrodedCORROSION ON AFT CABIN G4 GALLEY FLOORBEAM ANGLE AT BS 993, RBL 33 TO 45. REMOVED AND REPLACED FLOORBEAM ANGLE IAW 51-00-05-1, SRM 53-70-51-1A, AND DRAWING 147A5700.SDR AALA20170523008Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 951, RBL 27 TO 49. REMOVED AND REPLACED THE FLOORBEAM IAW 51-00-05-1, AND DRAWING 147A5700.SDR DALA2017052304194Channel · corrodedFWD CARGO BAY FLOORBEAM CHANNEL BS 690, LBL 10 - 14 CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS.IAW SRM 53-00-53-1A-1, DETAIL 5. REMOVED AND REPLACED THE CHANNEL IAW DRAWING 453N1172, AND SRM 51-40-02.SDR JR2R20170522276Floorbeam · corrodedFLOORBEAM HAS CORROSION FRAME 89. REMOVED AND REPLACED THE FLOORBEAM SPLICE IAW SRM 51.43-03.SDR AALA201706069025Floorbeam · corrodedCORROSION ON AFT GALLEY FLOORBEAM -Y765 AND FRAME 67 + 2 INCHES. REPLACED THE FLOORBEAM IAW SRM A319 5172-11.SDR A6WA2017052445023Floorbeam · crackedRBL 9 FLOORBEAM OTBD ANGLE CRACKED AT BS 280. REPLACED THE FLOORBEAM ANGLE IAW SRM 51-42-21.SDR A6WA2017052445024Floorbeam · crackedLBL9 FLOORBEAM ANGLE CRACKED AT BS 280. REPLACED THE FLOORBEAM ANGLE IAW SRM 51-42-21.SDR A6WA2017052445025Floorbeam · crackedLBL 9 FLOORBEAM OTBD ATTACH ANGLE CRACKED AT BS 280. REPLACED THE FLOORBEAM ANGLE IAW SRM 51-42-21.
Back to JASC 5315