JASC 5315
Service difficulty reports · 44,205
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR VNAA20251015032Floorbeam · corrodedFLOORBEAM AT FS333.00 RBL 9.00 IS CORRODED. REPAIRED IAW MHIRJ REO 670-53-21-25485 REV-- DATED 2025-02-18SDR REXA2026052800838Floorbeam · crackedAFTER CUT DOOR POST RBL12 AT FS 280.00 LOWER SECTION OF THE BULKHEAD POST, CRACK ON FLOORBEAM WAS FOUND. FLOORBEAM WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01SDR SWIA2025101475368Floorbeam · crackedFLOORBEAM AT BS 280 AND RBL 12 CRACKED ON THE AFT OUTBOARD FLANGE FROM APPROX WL 70.00 - WL 72.50. COMPLIED WITH REO 670-53-11-896 REV-. GENERIC REPAIR TO CENTER COCKPIT FLOORBEAM BS 280, WL70 - 72.50. AND REO 670-53-11-2195 REV -. REPAIR TO CENTER COCKPISDR AALA202510154678Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CARCK IN PASSENGER CABIN FLOORBEAM ASSEMBLY PANEL LOCATED AT BS 540, LBL 2. REPLACED FLOORBEAM ASSEMBLY PANEL PER AARD 51-00-05-1.SDR N6WA2025101401Floorbeam · corrodedFLOOR BOARD ATTACHED BRACKET AT FS280.00 HAS CORROSION. REMOVED AND REPLACED FLOORBOARD ATTACHED BRACKET AT FS280.00 IAW CRJ SRM 51-42-21SDR FDEA202510131975Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT BEAM CORRODED AT FR58 Y-805 - Y-1470 REPAIRED THE AFT CARGO COMPARTMENT CORRODED FLOOR SUPPORT BEAM AT FR58 Y-805 - Y- 1470 PER A300-600 SRM53-10-15-201 FIGURE 207 AND EA: 6-5321-T0385357 P1. TITLE: FUSELAGE - CARGO COMPSDR CALA2025101410068Floorbeam · corrodedMAIN CABIN AFT WET AREA CORROSION AT FLOORBEAM STA 947.5 LBL 53". ACCOMPLISHED REPAIR AT LT AFT WET AREA FLOORBEAM 947.5" LBL 53" PER B737-800 SRM 53-70-51-2R-5 AND SRM 51-40-02-0G-0SDR CALA2025102610536Floorbeam · corrodedB737-53-3-0737 MAIN CABIN AFT WET AREA R/H STA 987 RBL43 FRAME HAS CORROSION MARKED. REMOVED DAMAGE ONLY .150 MATERIAL LOSS .040 REMAINING .110 FOUND TO BE OUT OF LIMITS REF SRM 53-70-51-1A-1 FLOORBEAM REPAIRED.SDR CALA2025102610534Floorbeam · corrodedMAIN CABIN AFT WET AREA R/H STA 947 O/B LAV MOUNT, FRAME HAS CORROSION MARKED. REMOVED DAMAGE,HFEC NO DEFECTS NOTE,FABRICATED,LOCATED DRILLED, INSTALLED,AND RESTORED ,COUTINGS REF B737-800 SRM 53-70-51-2R-5 THIS IS A CAT A REPAIR NO FURTHER ACTION REQUIRED.SDR N6WA2025101403Floorbeam · corrodedCORROSION ON FLOOR PANEL ANGLE SUPPORT IN COCKPIT AT 280 BEAM. REMOVED AND REPLACED FLOOR PANEL ANGLE SUPPORT AT 280 IAW CRJ SRM 51-42-06SDR FDEA202510111961Floorbeam · crackedHIGH FREQUENCY EDDY CURRENT INSPECTION ON RIGHT HAND SIDE OVERWING FLOORBEAM UPPER FLANGE AT STATION Y = 1275.25. X = - 104.25 FOUND CRACK INDICATION APPROX X 0.8". CABIN - CRACK AT RIGHT HAND OVERWING FLOOR BEAM UPPER FLANGE STATION Y = 1275.25, X= - 104.25SDR DALA2025101307448Floorbeam · corrodedCABIN FLOORBEAM FOUND CORRODED AT Y-1959 TO Y-2462 FR 76. REMOVED AND REPLACED THE CABIN FLOORBEAM AT Y-1959 TO Y -2462 FR 76 IAW SRM 51-42-00. (1245712)SDR JJBA20251112025Floorbeam · corrodedCORROSION ON FLOOR BEAM FRAME 37 TO 38 STR 16L. REMOVED AND REPLACED OF FLOOR SILL BETWEEN FRAMES 35-39, STRINGER 16LSDR IPXA2025110593368Floorbeam · corrodedMAIN DECK CARGO COMPARTMENT BELOW ACCESS PANNEL FLOOR 231XSF HAS CORROSION. ACCOMPLISHED REPAIR PER EO-95804-REQ1 AND VT-SAA EA 757-5310-01-B0586, REV. IR, PRIOR TO FURTHER FLIGHT.SDR IPXA2025110593910Floorbeam · corrodedMAIN DECK CARGO COMPARTMENT STA 620 RBL-45.5 TO RBL-54.9 BELOW ACCESS PANNEL FLOOR 232XPF HAS CORROSION ON FLOORBEAM LOWER AREA, INSTALLED REPAIR PARTS AND TWO ANGLES ON FLOORBEAM UPPER CHORD APPROX. STA 620 BETWEEN RBL 45.5 AND RBL 62 IAW SRM 53-00-51-2R-6 RSDR IPXA2025110598112Floorbeam · corrodedMAIN DECK CABIN FLOORBEAM UPPER CHORD HAS CORROSION AT APPROX BS 1600, LBL 45.50 THRU LBL 62.22, ACCOMPLISHED REPAIR PER VT-SAA EA 757-5300-01-B0603, REV IR.SDR IPXA2025110598146Floorbeam · corrodedMAIN DECK CABIN FLOORBEAM LOWER CHORD HAS CORROSION ONTO SEVERAL AREAS AT APPROX BS 1360, BL 0 THRU LBL 45.50, ACCOMPLISH REPAIR PER EO-95790-REQ1 AND VT-SAA EA 757-5310-01-B0588, REV. IR, PRIOR TO FURTHER FLIGHT.SDR DALA2025101407505Floorbeam · corrodedAFT CABIN FLOORBEAM AT STA 986.5 LBL 13 TO LBL 44 CORRODED AROUND FASTENER HOLES. REPAIRED AFT CABIN FLOORBEAM AT STA 386.5 LBL 13 - LBL 44 IAW SRM 53-70-51-2R PROCEDURE 4.SDR SWAA2025111123048Floorbeam · corrodedCORRODED FLOORBEAM, BS 986.5, RBL 43, WL 208.1. REPAIRED THE FLOORBEAM IAW EA 25-153-02825-WIP1, EA 25-153-02825-WIP2, AND EA 25-153-02825.SDR JJBA20251110017Floorbeam · corrodedSURFACE CORROSION LOCATION: FLOOR BEAM, CENTER ISLE, UNDER PANEL 231FF. INSTALLED NEW FLOOR BEAM, CENTER AISLE, UNDER PANEL 231FFSDR AALA202510142819Floorbeam · brokenAIRCRAFT IN BASE MAINTENANCE: BROKEN PASSENGER CABIN FLOOR SUPPORT BREAK ASSEMBLY PANEL LOCATED ON LEFT HAND SIDE AT BS 540. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1.SDR AALA202510145138Floorbeam · brokenAIRCRAFT IN BASE MAINTENANCE: BROKEN PASSENGER CABIN FLOOR SUPPORT BREAK ASSEMBLY PANEL LOCATED ON RIGHT HAND SIDE AT BS 540. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1.SDR CALA2025101309954Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER TEE ANGLE HAS CORROSION AT BS 380 RBL 0. REMOVED CORROSION IAW IAW SRM 53-30-51. FOUND TO BE OUT OF LIMITS IAW 53-36-51, ORIG .125, MAT LOSS .038, REM .087 FABRICATED A STRAP AND FILLERS IAW REO-G25602 AND REO-25602 FIGURE 2. ALODSDR CALA2025101309953Floorbeam · corrodedMAIN CABIN FWD WET AREA FLOORBEAM, STA 312 LBL45 HAS CORROSION. CUT OUT CORRODED SECTION OF TEE CHORD AND REPAIRED WITH TEE CHORD, ANGLES AND STRAPS IAW SRM 53-10-51. REPAIR 12SDR AALA202510133528Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CARCK IN PASSENGER CABIN FLOORBEAM ASSEMBLY PANEL LOCATED AT BS 540, LBL 2. REPLACED FLOORBEAM ASSEMBLY IAW AARD 51-00-05-1.SDR AALA202510132791Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CARCK IN PASSENGER CABIN FLOORBEAM ASSEMBLY PANEL LOCATED AT BS 540, RBL 2. REPLACED FLOORBEAM ASSEMBLY PANEL PER AARD 51-00-05-1.SDR JR2R20251009278Floorbeam · corrodedAFT WET AREA, PANEL SUPPORT ON FWD SIDE OF FR87 JUST OUTBOARD OF RBL24 IS CORRODED. REPLACED.SDR SWI2026F00024Floorbeam · corrodedRBL9 HAS MULTIPLE SPOTS OF CORROSION ON TOP PLATE BETWEEN BS 409 TO BS 409+64. REPAIRED MULTIPLE SPOTS OF CORROSION ON TOP PLATE OF FLOORBEAM CAP REF SRM 53-00-43, REPAIR 2, STEP 5 A (7) FIG. 203 , REO. 601R-53-31-1354, REV--, STEPS 1 - 9, ALL OTHER REQUIRESDR SIMA20251028007Floorbeam · corrodedSSI 53-23-005: AFT GALLEY LH FLOOR BEAM CORRODED AT FR 87 (MAJOR REPAIR) (LEVEL 2 CORROSION). RAR THE LH FLOOR BEAM AT FR87 IAW ERJ 175 SRM 51-40-08SDR SIMA20251008006Floorbeam · corrodedSSI 53-23-005: AFT GALLEY RH CENTER FLOOR BEAM SPLICE CORRDED AT FR 89 (LEVEL 2 CORROSION). RAR AFT GALLEY RH CENTER FLOOR BEAM SPLICE AT FR 89 IAW ERJ 175 SRM 51-40-08.SDR SIMA20251008002Floorbeam · corrodedSSI 53-23-005: AFT GALLEY RH CENTER FLOOR BEAM SPLICE CORRDED AT FR 90 (LEVEL 2 CORROSION) RAR AFT GALLEY RH CENTER FLOOR BEAM SPLICE AT FR 90 IAW ERJ 175 SRM 51-40-08SDR CALA2025101610169Floorbeam · corrodedAFTER REMOVAL OF HARD POINTS FOUND CORROSION OUT OF LIMITS ON FLOORBEAM STA 947 BETWEEN RBL 30 AND RBL 55 (REF AAR NR 100005391 1 ) REPAIRED, INSTALLED REPAIR PARTS ON FLOOR BEAM STA 947 BETWEEN RBL 30 AND RBL 55 ALL WORK DONE IAW B373-800 SRM 53-70-51-2R-5,SDR CALA2025101009896Floorbeam · corrodedMAIN CABIN AFT WET AREA,CORROSION AROUND SCREW HOLES ON FLOORBEAM AT STA 947.5,BETWEEN LBL-10 AND RBL-10. ACCOMPLISHED REPAIR AT STA 947.5 FLOOR BEAM IN REF WITH B737 -900 ER SRM 53-00-51-2R-1, AAR ESR 20-12933 AND ECRA 5370-01199, PENDING ESFR ENTRY, NO DIP SDR CALA2025100909855Floorbeam · crackedDURING OK TO INSTALL, FOUND FWD CARGO BAY CEILING AREA FLOORBEAM INTERCOSTAL BS 700, RBL 24 CRACKED. REMOVED AND REPLACED INTERCOSTAL(WEB) AT FWD CARGO COMP CEILING AREA BS 700, RBL 2H IAW SRM 51-40-02-0G-0 REF DWG 140 N2506.SDR JJBA20251112026Floorbeam · corrodedCORROSION ON FLOOR BEAMS FRAME 44-45 AT STR 16L. REMOVED MOP SILL FROM FR 42 TO FR 48 AND REPLACED WITH NEW.SDR VNAA20251110001Floorbeam · crackedCRACK ON FLOORBEAM RBL 12.0 BTW FS 221.73 TO FS 229.00 AT FWD FUSELAGE INTERNAL STRUCTURE (FLIGHT COMPARTMENT FLOOR STRUCTURE BELOW WL79.50). FLOORBEAM RBL 12.0 BTW FS 221.73 TO FS 229.00 AT FWD FUSELAGE INTERNAL STRUCTURE (FLIGHT COMPARTMENT FLOOR STRUCTURSDR JJBA20251110020Floorbeam · corrodedLH FLOOR BEAM AT FR61 STR 4L HAS CORROSION. INSTALLED NEW FROM STOCK LH FLOOR BEAM GUSSET PLATE AT FR 61.SDR AALA202510148583Floorbeam · elongatedAIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLES LOCATED ON FR24 INBOARD SPLICE FLOOR BEAM -Y254 FWD GALLEY AREA (0.222 IN). MAINTENANCE REPLACED SPLICE LOCAED ON FR24 INBOARD FLOOR BEAM -Y254 FWD GALLEY AREA IAW A321 51-42-11-801, SRM 51-72-11-911-001 AND DWG D5SDR CALA2025101410056Floorbeam · corrodedMAIN CABIN AFT WET AREA CORROSION AT FLOORBEAM AROUND FITTING STA 947.5 RBL 52" (REF AAR N/R 99954162) ACCOMPLISHED REPAIR AND INSTALLED REPAIR PARTS AT MAIN CABIN AFT WET AREA FLOORBEAM BS 947.5" RBL 34" TO RBL 60" PER SRM 53-70-51-2R-5 AND ECRA 5370-01201.SDR AALA202510131809Floorbeam · wornAIRCRAFT IN BASE MAINTENANCE: FORWARD CABIN FLOOR BEAM OUTBOARD SPLICE HAS WORN / ELONGATED HOLES AT FR 24 AND -Y254. REPLACED SPLICE PER SRM 51-72-11.SDR DALA2025100907369Floorbeam · corroded(LOG 1239122) CABIN FLOORBEAM AT STA 986.5 FROM RBL 23 TO RBL 44 CORRODED AROUND FASTENER HOLES. REPAIRED AFT CABIN FLOORBEAM AT STA LOCATED AT RBL 44 AS PER REF SRM 53-70-581-212-G FIG 205.SDR IXXA20251006002Floorbeam · crackedBULK CARGO FLOOR SUPPORT BEAM CRACKED @ STA1480, RBL14SDR CALA2025100809793Floorbeam · corrodedMAIN CABIN AFT WET AREA CORROSION AT FLOOR BEAM PREVIOUS REPAIRSTA 986.5 RBL 45"-LBL 45". REMOVED AND INSTALLED REPAIR PARTS (T-CHORD -1 , ANGLES -2 , ANGLES -3, STRAP -4) AT STA 986.5 FROM LBL 51 TO RBL 51 IAW SRM 53-70-51-2R-4.SDR CALA2025100709742Floorbeam · corrodedFORWARD PASSENGER CABIN FLOORBEAM UPPER SURFACE HAS CORROSION SPOT B.S. 380 LBL. 56". REMOVED CORROSION ON CABIN FLOORBEAM UPPER SURFACE B.S. 380 LBL 56", AND ACCOMPLISHED REPAIR IAW REF. AAR-MIA ESR-WI#13-12756 REV. ORIGINAL.SDR JR2R20251005210Floorbeam · corrodedRH FLOORBEAM UPPER STRAP AT RBL 10 BETWEEN FR85-FR86 IS CORRODED OUT OF LIMITS. REPLACEDSDR SWIA2025121200004Floorbeam · corrodedSIGNS OF CORROSION NOTED AT FLOORBEAM FS280 RBL12. R & R THE FLOORBEAM IAW SRM 53-00-00, AMM 20-70-00, SRM 51-42-06, SRM 51-42-21, SRM 51-42-13, SRM 53-11-10, SRM 51-24-21, SRM 51-40-11, SRM 51-21-11, SRM 51-25-06, AND SRM 51-25-16. PERFORMED NDT INSPECTION,SDR JJBA20251112028Floorbeam · corrodedMID FLOOR BEAM AT FR 61, STR 1R HAS CORROSION. REMOVED DAMAGED GUSSET AND INSTALLED NEW MID FLOOR BEAM GUSSET PLATE AT FR61SDR JJBA20251112027Floorbeam · corrodedRH FLOOR BEAM AT FR 61, STR 4R HAS CORROSION. REMOVED AND REPLACED GUSSET PLATE AT FR 61 STR 4RSDR AALA202510283227Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOORBEAM UPPER CHORD (T-CAP) AT STA 947.5, LBL 24. REPLACED UPPER CHORD PER SRM 53-70-51-2R-4.SDR SWAA2025102721477Floorbeam · crackedCRACKED BRAKE PANEL FLOORBEAM LOCATED BS 540, BL 0 TO RBL 24.75 AT PASSENGER CABIN REPLACED FLOORBEAM AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 143A0060, SHEET 36, REV A.
Back to JASC 5315