JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011110906131Floorbeam · damagedDUE TO A MAJOR REPAIR OF THE BS 324 FLOORBEAM UPPER CHORD DURING HMV 3 VISIT, AN INITIAL FIRST STAGE APPROVAL WAS RECEIVED. THIS REPAIR MUST RECEIVE A NEW 8100-9 SHOWING COMPLAINCE TO 14CFR 25.571 AND 26.43(D) AND DTA INCORPORATED INTO THE AIRCRAFT MAINTENANCSDR FDEA201111094848Floorbeam · corrodedFLOORBEAM AT FR47 BETWEEN SEAT TRACKS NR1-2L UP SIDE CORRODED AT BOTH ENDS REF AMM 53-10-15-06, ZONE 240. REMOVED CORROSION ON FLOORBEAM IAW SRM 51-74-10. FLOORBEAM IS FOUND TO BE OUT OF LIMITS DUE TO MORE THAN 50 PERCENT MATERIAL LOSS. MATERIAL THICKNESSSDR UALA2011110906129Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 852 LBL-11 (100% MATERIAL LOSS). REMOVED FLOORBEAM AT STA 852 DUE TO OUT OF LIMITS IAW SRM 53-00-51. FABRICATED UPPER TEE CHORD, ANGLES AND FILLER IAW B767 SRM 53-00-51. ALODINED AND PRIMED IAW 767 SRM 51-20-04. INSTALLED REPASDR UALA2011110906127Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 323 RBL 40.5 AND 60.0. MAJOR REPAIR ACCOMPLISHED: CORROSION AT STA 324 RBL 40.5 AND 60 REPAIRED PER INSTRUCTIONS ON EA PD57-53-225 AND UA EVA 81467 WITHOUT DEVIATION. CF CREATED FOR DTA.SDR ASOA201102141Floorbeam · corrodedFS 280 FLOORBEAM HAS CORROSION RT SIDE. CORROSION OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. REPAIRED IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 51-42-22-001-001-A01.SDR ASOA201102140Floorbeam · corrodedFS 280 FLOORBEAM HAS CORROSION LEFT SIDE. FOUND FLOORBEAM CRACKED BEYOND REPAIRABLE LIMITS. REMOVED FLOORBEAM IAW SRM 51-42-06-001-001-A01. INSTALLED FLOORBEAM IAW SRM 51-42-06-001-001.SDR FDEA201111094829Floorbeam · corrodedCABIN, FLOORBEAM AT STA 333.5 LBL 50 HAS CORROSION ON UPPER CHORD. R & R IAW SRM 51-40-02, REV 104. REPAIR CLASSIFIED AS MAJOR.SDR CNMA20111109043Floorbeam · corrodedCORROSION ON FLOORBEAM BS 1660 LBL 52 TO RBL 52 . REPAIRED FLOORBEAM IAW MESSAGE NR FSA-OAE-11-0002-06B.SDR USAA2011121900008Floorbeam · corroded2S CHECK - CORROSION ON FLOORBEAM BETWEEN FR66 TO FR70, -Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR70, -Y765 IAW A320 SRM 51-72-11 & EA 200143A.SDR USAA2011121600016Floorbeam · corroded2S CHECK - CORROSION ON FLOORBEAM BETWEEN FR67+17 INCHES TO FR69+5 INCHES, -Y1162. REPLACED FLOORBEAM BETWEEN FR67+17 INCHES TO FR69+5 INCHES, -Y1162 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472780.SDR ASOA201102129Floorbeam · corrodedCOCKPIT FLOORBEAM AT FS.280.00 IS CORRODED. R & R FLOORBEAM IAW SRM 51-42-06-001-001-A01.SDR AALA20111108TUL03Floorbeam · crackedCRACKED FLOORBEAM AT STATION 700 LEFT BUTTLINES 24 TO 48. INSTALLED DOUBLER PER SRM 53-00-51-2R.SDR CNMA20111108044Floorbeam · corrodedBOTTOM FLANGE OF FLOORBEAM BS 1681, LBL 47 CORRODED. REPAIRED FLOORBEAM IAW MESSAGE FSA-OAE-11-0003-01C.SDR SWAA117749Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED BETWEEN BS 707 TO BS 712, RBL 24.5. REPAIRED WEB IAW EA.SDR R61A20110355Floorbeam · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND AFT RIGHT FLOORBEAM AT FRAME 85 AND 87 CORRODED. MAINTENANCE REMOVED AND REPLACED AFT RIGHT FLOORBEAM AT FRAME 85 AND 87 IAW EMB 175 SRM 51-43-01, AND 51-41-01. AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR SWIA201130927Floorbeam · corrodedCORROSION ON FLOORBEAM OUTBOARD FLANGE AT FS 615.0 LBL 27.0. (C-CHECK) REPAIRED IAW REO.SDR AALA20111107TUL03Floorbeam · corrodedSTATION 1640 UPPER FLOORBEAM REPAIR UPPER DOUBLER AND FRAME CORRODED LEFT BUTTLINE 6 TO RIGHT BUTTLINE 12. REPAIRED LATERAL I BEAM/FLOOR SUPPORT BY INSTALLING T CAP REPAIR PER SRM 53-00-51-2, REPAIR 3.SDR SWAA117675Floorbeam · corrodedDURING SCHEDULED 18Y CHECK, FOUND AFT CARGO BAY FLOOR BEAM CORRODED BETWEEN BS 727D+2 TO BS 727D+6, RBL 13. REMOVED AND REPLACED BEAM IAW SRM AND DWG.SDR EE4Y201111070616Floorbeam · corrodedDURING THE ACFT MX SERVICE, FOUND THE UPPER FUSELAGE PAX CABIN STA FR21- Y254 FLOORBEAM WITH CORROSION. REPLACED FLOORBEAM, UPPER FUSELAGE PAX CABIN YSTA 254-FR21 IAW SRM 51-72-11.SDR EE4Y20110595Floorbeam · corrodedDURING THE INSPECTION, FOUND THE UPPER FUSELAGE PAX CABIN FR21, YSTA 254 FLOORBEAM WITH COROSION.SDR EE4Y201111070594Floorbeam · corrodedDURING THE INSPECTION FOUND THE UPPER FUSELAGE PAX CABIN STA FR 66 Y STA 1292 FLOORBEAM WITH COROSION.SDR SWAA117612Floorbeam · corrodedDURING SCHEDULED 26Y CHECK, FOUND FLOORBEAM CORRODED AT BS 986, RBL 50. REPAIRED BEAM PER SRM.SDR AALA20111109TUL02Floorbeam · corrodedCORROSION ON FLOORBEAM FROM RIGHT BUTTLINES 12 TO 56 AT STATION 1680. ACCOMPLISHED NESTED ANGLE REPAIR PER SRM 53-00-51-2, REPAIR 2.SDR DALA1166150695Floorbeam · corrodedSUPP INFO FOR NRC 200978 - MAIN CABIN FLOORBEAM CORRODED STA 1640 RBL 30-LBL 30. REMOVED CORROSION ON FLOORBEAM STA 1640, FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED SECTION OF FLOORBEAM, FABRICATED REPLACEMENT UPPER CHORD AND REPAIR ANGLES AND INSTALLED REF SDR DALA1162570695Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED STA 1640 RBL 30-LBL 30.SDR A6WA201140962Floorbeam · crackedFLOORBEAM CRACKED AT THE 280 BULKHEAD, RBL 9. REPAIRED FLOORBEAM IAW REO 601R-53-11-136, 601R-53-11-2225 AND 601R-53-11-171.SDR DALA1163446310Floorbeam · crackedCRACK WAS FOUND ON FLOORBEAM WEB AT STA 840 RBL 5 WL 305 IN CABIN. L=1.5 SCEPTRE LOG PAGE ENTERED AND DEFERRED FOR SDR REPORTING. PERFORMED CATEGORY "B" REPAIR PER SRM 53-00-51 REPAIR 1 (B747-400). VISUALLY INSPECT THE REPAIR PARTS, UPPER AND LOWER CHORDS ANSDR SWIA201128451Floorbeam · crackedFS 280 FLOORBEAM CRACKED. (C-CHECK) REPLACED FLOORBEAM PER SRM.SDR A6WA201141058Floorbeam · crackedFLOORBEAM IS CRACKED AT BS 280 BULKHEAD. LT SIDE IS JUST OTBD OF LBL9. R & R DAMAGED IAW REO 601R-53-11-171 & 601R-53-11-138.SDR UALA2011110305953Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 365.25 RBL 5 TO RBL 65. MAJOR REPAIR ACCOMPLISHED: CORROSION IS BEYOND LIMITS PER B757 SRM. REMOVED PART AND FABRICATED A NEW CHORD REPAIR ANGLE 2&3, REPAIR STRAP 4 & 5 IAW B757 SRM. TREATED AND PRIMED ALL PARTS IAW B757 AND TSDR SWAA117587Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDNAL FLOORBEAM WEB CRACKED BETWEEN BS 706 TO BS 711, BBL 0.07. REPAIRED BEAM IAW SI.SDR A6WA201141057Floorbeam · corrodedBS 559.0+112 LBL 27 FLOORBEAM CAP CORRODED. R & R LBL 27 FLOORBEAM CAP IAW FORM 412 AND SRM.SDR ASOA201102244Bracket · crackedREMOVED BRACKETS FROM FS 280 FLOORBEAM AT LT AND RT BL 9. UPON REMOVAL FOUND LT & RT TEE BRACKET TO BE CRACKED REMOVED BY SRM 51-42-21-001-001-A01. DRILLED UP NEW TEE BRACKET LT & RT AND INSTALLED ON ACFT AFTER FS280 REPAIR IAW SRM 51-42-21-001-001-A01. THISDR ASOA201102097Floorbeam · corrodedFS 349.00, RBL 27 TO SILL FLOORBEAM CORRODED. REMOVED CORROSION IAW REO 601R-53-21-2222. FOUND OUT OF LIMITS.SDR ASOA201102094Floorbeam · crackedFLOORBEAM RBL 27 AT FS 484 IS CRACKED IN UPPER RADIUS. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-21.SDR ASOA201102093Floorbeam · crackedFLOORBEAM RBL 9 AT FS 484 IS CRACKED IN UPPER RADIUS. R & R FLOORBEAM IAW SRM 51-42-06 & REO 601R-53-41-1514, STEPS 1 & 2.SDR SWAA117544Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED BETWEEN BS 660 TO BS 673, LBL 24.5. REPAIRED CHORD IAW ER AND EA.SDR SWAA117530Floorbeam · crackedDURING SCHEDULED SPV CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED BETWEEN BS 639 TO BS 640, WL 202. REPAIRED WEB IAW ER AND EA.SDR DALA1160911703Floorbeam · crackedFLOORBEAM UPPER CHORD CRACKED AT FS 654+44 LBL 13 IN FWD CARGO COMP.SDR EIAA2011245Floorbeam · corrodedCORROSION ON FLOORBEAM CAP AT NUT PLATE BS 2220 LBL 60. REMOVED CORROSION, REMOVED AND REPLACED SECTION OF FLOORBEAM AT BS 2220 LBL 60 PER 747-400 SRM 51-70-12 FIG 201 REPAIR 1.SDR EIAA2011244Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 2140 LBL 72. REMOVED CORROSION, FABBED AND INSTALLED REPAIR PER 747-400 SRM 51-70-12 FIG 201.SDR EIAA2011243Floorbeam · corrodedFLOORBEAM BS 2240 LBL 72 HAS CORROSION. REMOVED CORROSION AND INSTALLED REPAIR PER B747-400 SRM 51-70-12 PAGES 201-202.SDR HYIA836HC201121Floorbeam · damagedDURING HEAVY CHECK FLOORBEAM FR13 WAS BEING REPLACED. DURING THE INSTALLATION THE OEM DESIGNED CONTROL CABLE GUIDE THROUGH-HLOES WERE ACCIDENTALLY DRILLED ON THE WRONG (OPPOSITE) SIDE OF THE BL0. REPAIRED IAW STS EA 09-2011-227. REPAIR PERFORMED BY TECH SERSDR USAA2011111500023Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, Y512.5. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, Y512.5 IAW A320 SRM 51-72-11.SDR USAA2011111500021Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, Y512.5. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, Y512.5 IAW A320 SRM 51-72-11.SDR USAA2011111500016Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR Z-BEAM BETWEEN FR68 TO FR70, Y1162.5. REPLACED FLOOR Z-BEAM BETWEEN FR68 TO FR70, Y1162.5 IAW A320 SRM 51-72-11.SDR USAA2011111500015Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR Z-BEAM BETWEEN FR66 TO FR68, Y1162.5. REPLACED FLOOR Z-BEAM BETWEEN FR66 TO FR68, Y1162.5 IAW A320 SRM 51-42-11.SDR USAA2011111500014Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR Z-BEAM BETWEEN FR64 TO FR66, Y1292. REPLACED FLOOR Z-BEAM BETWEEN FR64 TO FR66, Y1292 IAW A320 SRM 51-42-11.SDR DALA1162546816Floorbeam · corrodedMAIN CABIN FLOORBEAM HAS EXISTING SCRIBE LINE, HOLES WITH NO ED AND CORROSION STA 1640 RBL 60 LBL 60.SDR USAA2011110700005Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON UPPER SURFACE OF FLOORBEAM AT FR65+22", S23L, Y765. REPLACED FLOORBEAM AT FR65+22", S23L, Y765 IAW A320 SRM 51-42-00.
Back to JASC 5315