JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011112400004Floorbeam · corrodedC11/SY6 CHECK, CORROSION ON FLOOR BEAM AT FR 66 - 3" AT -Y1292 AND Z-500. REPLACED FLOOR BEAM AT FR 66 - 3" AT -Y1292 AND Z-500 IAW A321 SRM 51-42-11 AND 51-72-11.SDR USAA2011112300023Floorbeam · corrodedC11 CHECK - LEVEL 2 CORROSION ON FLOORBEAM AT FR66, -Z500, Y1292. REPLACED FLOORBEAM AT FR66, -Z500, Y1292 IAW A321 SRM 51-72-11.SDR USAA2011112300022Floorbeam · corrodedC11 CHECK - LEVEL 2 CORROSION ON FLOORBEAM BETWEEN FR66 TO FR69, -Z500, Y1292. REPLACED FLOORBEAM BETWEEN FR66 TO FR69, -Z500, Y1292 IAW A321 SRM 51-72-11.SDR USAA2011112300021Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR70, -Z500, Y765. REPLACED FLOORBEAM BETWEEN FR64 TO FR70, -Z500, Y765 IAW A321 SRM 51-42-11.SDR USAA2011112300020Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR23, -Z500, -Y180. REPLACED FLOORBEAM BETWEEN FR20 TO FR23, -Z500, -Y180 IAW A321 SRM 51-42-11, 51-72-11 & AIRBUS DRAWING D53111406.SDR USAA2011112300019Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR23, -Z500, Y254. REPLACED FLOORBEAM BETWEEN FR20 TO FR23, -Z500, Y254 IAW A321 SRM 51-72-11, 51-42-11 & 51-21-11.SDR USAA2011112300017Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR12 TO FR16, -Z500, -Y81. REPLACED FLOORBEAM BETWEEN FR12 TO FR16, -Z500, -Y81 IAW A321 SRM 53-11-14, 51-43-00 & 51-42-00.SDR USAA2011112300016Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR12 TO FR24, -Z500, -Y254. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, -Z500, -Y254 IAW A321 SRM 51-72-11 & AIRBUS DRAWING D53112816.SDR VNAA2011111500011Floorbeam · crackedDURING SCHEDULED MAINTENANCE THE FS 280.0 FLOOR TRAVERSE BEAM WAS FOUND CRACKED. THE FS 280.0 FLOOR TRAVERSE BEAM WAS INSPECTED AND REPAIRED USING AIRCRAFT MAINTENANCE MANUALS. AIRCRAFT WAS RELEASED FOR SERVICE.SDR USAA2011111800012Floorbeam · corrodedC11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR16, Z500, Y502.3. REPLACED FLOORBEAM AT FR16, Z500, Y502.3 IAW A321 SRM 51-72-11 & 51-42-11.SDR DU4R20111115018Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FWD CABIN FLOORBEAM BS 312, RBL 12 TO LBL 56.SDR MALA110262Floorbeam · corrodedRT 280 FLOORBEAM HAS CORROSION AT THE TOP SIDE IN CABIN. REMOVED AND INSTALLED NEW RT FLOORBEAM IAW SRM 51-42-06 AND 51-42-21 ALONG WITH EO R53117.SDR AALA20111114TUL02Floorbeam · corrodedFLOORBEAM CORRODED STATION 1681. ACCOMPLISHED FLOORBEAM REPAIR.SDR ASOA201102183Floorbeam · crackedFS 460 SUPPORT ON OTBD SIDE OF RBL 9 PRESSURE FLOORBEAM IS CRACKED. REMOVED CRACKED SUPPORT FITTING IAW SRM 51-42-06, 51-42-21 & 51-40-11. INSTALLED NEW SUPPORT IAW SRM 51-42-06 & 51-42-21.SDR ASOA201102182Floorbeam · crackedFS 280 FLOORBEAM ANGLE CRACKED AT LBL 10 FROM MLG ALT EXT PULLEY BRACKET UPPER OTBD BOLT. REMOVED ANGLE IAW SRM 51-42-06 AND 51-42-20. INSTALLED ANGLE IAW REO 601R-53-11-926.SDR ASOA201102181Floorbeam · crackedFS 280, LBL 9 OTBD FLOORBEAM CLIP IS CRACKED IN UPPER PANELS. REPAIRED.SDR UALA2011111506244Floorbeam · corrodedSTA 325, RBL 45 FLOORBEAM CORRODED. MAJOR REPAIR ACCOMPLISHED DUE TO 100 PERCENT MATERIAL LOSS RMV'D AREA IAW B767 SRM. FABRICATED, TREATED, PRIMED AND INSTALLED REPAIR PARTS ON FLOORBEAM AT STA 325 RBL 45 IAW B767 SRM 53-00-51 REPAIR 2.SDR UHLA2011111300413Floorbeam · corrodedLEVEL 2 CORROSION L FLOORBEAM IN FRONT OF CF I IN SEVERAL AREAS. REMOVED AND REPLACED CF I LT FLOORBEAM IAW EMB 170 SRM 51-41-02, 51-43-01, AND 51-43-02.SDR MALA110261Floorbeam · corrodedLT 280 FLOORBEAM HAS CORROSION BUBBLING THRU THE FASTENERS, AT THE TOP SIDE. REMOVED AND INSTALLED NEW LT 280 FLOORBEAM IAW SRM 51-42-06 AND 51-42-21.SDR UHLA2011111300398Floorbeam · corrodedLEVEL 2 CORROSION FLOORBEAM FWD OF CFI AREA ON RT SIDE. REMOVED AND REPLACED RT LWR FWD CFI SEAT TRACK EXTENSION IAW EMB 170 SRM 51-40-02, 51-40-04, 51-41-01, 51-41-02, 51-43-01, AND 51-43-02.SDR IPXA11M70334Floorbeam · damagedLOWER FWD CARGO BAY FLOORBEAM DAMAGED, BS 979. REPAIRED IAW EO MD11-5310-41454-C.SDR UALA2011111406200Floorbeam · corrodedAFT DECK AREA AT STA 1681 FLOORBEAM AT RBL 32 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND BLEND OUT OF LIMITS OF SRM. CUT OUT DAMAGED AREA & ACP NDT OF OF OPEN HOLES COMMON TO REPAIR AREA FOR CRACKS. NONE FOUND. ACP INSURANCE CUT. SDR UALA2011111406193Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 1640 BL 0 - RBL 62. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND BLEND OUT OF SRM LIMITS. CUT OUT DAMAGED UPPER CHORD SECTION OF FLOORBEAM FROM LBL 10 TO RIGHT END OF FLOORBEAM REF PEMCO EA PD57-53-231 & SRM 53-00-51 FISDR AALA20111119TUL07Floorbeam · corrodedFLOORBEAM CORRODED AT STATION 312 RIGHT BUTTLINE 20. INSTALLED REPAIR DOUBLER PER 53-00-51-2R REPAIR 1.SDR SWIA201128596Floorbeam · crackedFS 280 FLOORBEAM CRACKED. (C-CHECK) REPLACED FLOORBEAM PER SRM.SDR CNMA20111112048Floorbeam · corrodedCORROSION ON TOP FLANGE OF FLOORBEAM (TOP AND BOTTOM OF FLANGE) BS 1640. REPAIRED FLOORBEAM IAW MESSAGE FSA-OAE-11-0001-15B.SDR CALA2011111400730Floorbeam · corrodedSUPPORT TASK AFT CABIN FLOORBEAM AT STA 947.5 HAS HEAVY CORROSION AT LBL 48 AT AFT O/B LAV MOUNT. TRIMMED OUT DAMAGED SECTION AND INSTALLED REPAIR REF SRM 53-70-51 REPAIR 5.SDR USAA2011112900004Floorbeam · corrodedS2 CHECK, CORROSION ON FLOORBEAM AT FR 73 AND Y+1278. REPLACED FLOORBEAM AT FR 73 AND Y+1278 IAW A330 SRM 53-41-14, 51-42-11 AND 51-72-11.SDR USAA2011112900003Floorbeam · corrodedS2 CHECK, CORROSION ON LONGITUDINAL FLOORBEAM AT FR 74 AND Y-1137.1. REPLACED LONGITUDINAL FLOORBEAM AT FR 74 AND Y-1137.1 IAW A330 SRM 53-00-15, 51-44-11, 51-72-11 AND 51-42-11.SDR USAA2011112100036Floorbeam · corrodedS2 CHECK - GALVANIC CORROSION ON FLOORBEAM BETWEEN FR75 TO FR76, -Y1447.8. REPLACED FLOORBEAM BETWEEN FR75 TO FR76, -Y1447.8 IAW A330 SRM 53-00-15 & 51-42-11.SDR USAA2011112100035Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR71 TO FR73, -Y2462. REPLACED FLOORBEAM BETWEEN FR71 TO FR73, -Y2462 IAW A330 SRM 53-31-15 FIG 101, 51-42-11 & 51-44-11.SDR USAA2011111800029Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR76, -Y2462. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR76, -Y2462 IAW A330 SRM 53-41-14 FIG 103 & 51-42-11.SDR USAA2011111800028Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR78, -Y350. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR78, -Y350 IAW A330 SRM 53-41-14 FIG 103 & 51-42-11.SDR USAA2011111800027Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR78, Y350. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR78, Y350 IAW A330 SRM 53-41-14 FIG 103 & 51-42-11.SDR FDEA201111114878Floorbeam · corrodedR2 DOOR ENTRANCE FLOORBEAM CORRODED, BS 324.0, RBL 30.0-62.0. REMOVED CORROSION, ORIGINAL MATERIAL .125 THICK AFTER REWORK .070 THICK L=5', W=2'D=.055, IAW SRM 51-10-02, FOUND OUT OF LIMITS IAW-SRM-53-00-51. R & R TOP FLOORBEAM TEE IAW SRM-51-40-02. CAT "ASDR USAA2011120500013Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM AT FR78, Y1137.1. REPLACED LONGITUDINAL FLOORBEAM AT FR78, Y1137.1 IAW A330 SRM 53-41-14, 51-44-11, 51-74-00 & 51-42-11.SDR USAA2011120500008Floorbeam · corrodedS2 CHECK - LEVEL 2 FILIFORM CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR78 TO FR80, Y450. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR78 TO FR80, Y450 IAW A330 SRM 53-41-14 FIG 103 & 51-42-11.SDR USAA2011120500007Floorbeam · corrodedS2 CHECK - LEVEL 2 FILIFORM CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR76, Y794.3. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR76, Y794.3 IAW A330 SRM 53-41-14 FIG 103.SDR USAA2011120500006Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR74 TO FR76, Y1137.1. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR74 TO FR76, Y1137.1 IAW A330 SRM 51-74-00, 53-41-14 & 51-42-11.SDR USAA2011120500005Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR80+4 INCHES, Y450. REPLACED FLOORBEAM AT FR80+4 INCHES, Y450 IAW A330 SRM 51-42-11, 51-74-00 & 53-41-14.SDR USAA2011112100038Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR73, Y2462. REPLACED FLOORBEAM AT FR73, Y2462 IAW A330 SRM 53-00-15 & 51-42-11.SDR USAA2011112100037Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR78, Y=0. REPLACED FLOORBEAM AT FR78, Y=0 IAW A330 SRM 53-41-14 & 51-42-11.SDR USAA2011111800026Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR76, Y1447.8. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR75 TO FR76, Y1447.8 IAW A330 SRM 53-00-15 & 51-42-11.SDR USAA2011111800025Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL FLOORBEAM AT FR70, Y1447.8. REPLACED LONGITUDINAL FLOORBEAM AT FR70, Y1447.8 IAW A330 SRM 53-00-15 & 51-42-11.SDR USAA2011111700007Floorbeam · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR73+10 INCHES & BETWEEN Y1447 TO Y1959. REPLACED FLOORBEAM AT FR73+10 INCHES & BETWEEN Y1447 TO Y1959 IAW A330 SRM 51-42-11.SDR UALA2011111106156Floorbeam · corrodedCABIN FLOORBEAM STA 1640 LBL 33 TO RBL 58 HAS CORROSION ON UPPER CAP. ITEM REPAIRED IAW SCAL EC RA 5310-05411, EVA 81444, AND CAL NR 9952002.SDR UALA2011111106155Floorbeam · damagedCABIN FLOORBEAM UPPER CAP STA 365 FROM BL 0 TO RBL 63. (P54-221-011). MAJOR REPAIR ACCOMPLISHED: ITEM REPAIRED IAW SCAL EC RA 5310-05413, EVA81445, AND SCAL NR 9952160.SDR UALA2011111106154Floorbeam · corrodedCABIN FLOORBEAM STA 324, RBL 44 IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REPLACED UPPER T-CHORD SECTION AT STA 324 BETWEEN LBL 14 TO RT FRAME JOINT PER SCAL ECRA 5310-05412 AND EVA 81446.SDR ASOA201102152Floorbeam · corrodedCORROSION ON FLOORBEAM AT FS 349. RBL 41 TO RBL 42. REPAIRED IAW REO 601R-53-21-2224, STEP 1 & 2.SDR IPXA11M70306Floorbeam · corrodedINSPECTION TYPE:C, CENTER CARGO AT BS 1841, X=-31 TO 52, FLOORBEAM LOWER TEE FOUND CORRODED. CORROSION REMOVED & FOUND EXCEED LIMITS IAW SRM 53-00-00, FIG 205. CORROSION TRIMMED OFF IAW EN:1350-11. HFEC INSPECTION CARRIED OUT, NO CRACK EVIDENT. REPAIR CHAN
Back to JASC 5315