JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR EIAA2011054Floorbeam · damagedUPPER DECK FLOOR BS 600 LBL TO LBL 77 TOP CAP ON FLOORBEAM HAS 6 EA DOUBLE DRILLED HOLES. REMOVED DAMAGE, FABBED REPAIR PARTS AND INSTALLED PER B747 SRM 53-10-07 FIG 21.SDR EIAA2011051Floorbeam · damagedFLOORBEAM UPPER CHORD INSERT DAMAGED AT BS 2220 BL 0. REMOVED DAMAGE, FABBED AND INSTALLED REPAIR PER B747 SRM 51-40-04 FIG 1.SDR SWAA114447Attach Fitting · crackedDURING SCHEDULED 14Y CHECK, FOUND LONGITUDINAL FLOORBEAM ATTACH CLIP CRACKED AT BS 639, LBL 45.5. REMOVED AND REPLACED CLIP ER AND EA.SDR MALA110150Floorbeam · corrodedFLOOR SUPPORT ANGLE FWD OF 280 CROSSBEAM HAS MINOR SURFACE CORROSION. REMOVED MINOR SURFACE CORROSION ON FLOOR SUPPORT ANGLE IAW SRM 51-21-06-001-001-A01.SDR AALA20110616TUL04Floorbeam · damagedFLOORBEAM STATION 1702 TO 1721 RIGHT BUTTLINE 15 DAMAGED. REPLACED FLOORBEAM PER SRM 51-10-02-OG.SDR AALA20110616TUL03Floorbeam · damagedFLOORBEAM STATION 1702 TO 1721 RIGHT BUTTLINE 39.5 DAMAGED. REPLACED FLOORBEAM PER SRM 51-10-02 OG.SDR AALA20110616TUL01Floorbeam · damagedFLOORBEAM STATION 1702 TO 1720 DAMAGED. REPLACED FLOORBEAM PER SRM 51-10-02-OG.SDR SWAA114398Floorbeam · crackedDURING SCHEDULED 14Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED BETWEEN BS 709 TO BS 713. REPAIRED WEB PER EO.SDR SWAA114380Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM CRACKED AT BS 673.75, RBL 24.5. REPAIRED BEAM PER EA.SDR SWAA114379Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM CRACKED AT BS 707, LBL 24.5. REPAIRED BEAM PER EA.SDR SWAA114378Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM CRACKED AT BS 671, LBL 24.5. REPAIRED BEAM PER EA.SDR K11A2012060616007Floorbeam · corrodedUPPER FLOORBEAM CAP TOP SIDE HAS SEVERAL AREAS OF CORROSION (1X1 INCHES).SDR USAA2011070100025Strap · crackedMCN - C23 CHECK - CRACK ON FLOORBEAM STABILIZING STRAP AT BS 344, BL 0. REPAIRED FLOORBEAM STABILIZING STRAP AT BS 344, BL 0 IAW B737 SRM 53-10-51 FIG 201.SDR USAA2011062700005Floorbeam · corrodedMCN - C11 - LEVEL 2 EXFOLIATION CORROSION FLOORBEAM BETWEEN FR68 TO FR69, -Z240, -Y1292. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, -Z240, -Y1292 IAW A319 SRM 51-72-11.SDR USAA2011062300026Floorbeam · corrodedMCN - C11 - LEVEL 2 EXFOLIATION CORROSION FLOORBEAM AT FR66, -Z240, Y1292. REPLACED FLOORBEAM AT FR66, -Z240, Y1292 IAW A319 SRM 51-42-11.SDR UALA2011061602959Floorbeam · corrodedCORROSION FOUND AT STATION 287, RBL 88.5 FWD OF DOOR R-1 ON FLOORBEAM. MAJOR REPAIR ACCOMPLISHED: ON PEMCO NR 2682N00490 EMP 600025 AND INSP 842. REMOVED DAMAGE AT UPPER FLOORBEAM CAP. NDT IAW B767 NDTM. NO CRACKS INDICATED. FABRICATED REPAIR STRAP PER ESDR FDEA201106152274Floorbeam · corrodedSTA 377, RBL 4 TO RBL 12 FLOORBEAM CORRODED MAIN CABIN. BLENDED AREA FOUND TO BE OUT OF LIMITS IAW SRM-53-00-51, FIG 101, DETAIL III ORIGINAL. MATERIAL .125 REMOVED .016, REMAINING MATERIAL .109. R & R FLOORBEAM IAW SRM 51-40-02. MAJOR REPAIR.SDR FDEA201106152273Floorbeam · corrodedSTA 395, RBL 54 FLOORBEAM CORRODED MAIN CABIN. REMOVED CORROSION IAW SRM 51-10-02. FOUND OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III. REMOVED FLOORBEAM IAW SRM 51-40-02. DRILLED AND LOCATED NEW FLOORBEAM IAW SRM 53-10-51 DETAIL II AND SRM 51-40-05.SDR FDEA201106152272Floorbeam · corrodedSTA 365, BL 0 TO RBL 17 CORROSION ON FLOORBEAM MAIN CABIN. REMOVED CORROSION IAW SRM 51-10-02. ORIGINAL MATERIAL .125 MATERIAL REMOVED .015 REMAINING MAT .110. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III. REMOVED FLOORBEAM IAW SRM 51-40SDR FDEA201106142425Floorbeam · corrodedFLOORBEAM AT BS 680, LBL 45 TO RBL 25 HAS CORROSION. REMOVED CORROSION, CUTOUT DAMAGED AREA IAW SRM 51-10-6, FABRICATED REPAIR PARTS IAW SRM 53-10-8, INSTALLED REPAIR PARTS IAW SRM 51-30-5, 51-10-2, 51-30- 2.SDR USAA2011062300007Floorbeam · corrodedBFM - C3 - LEVEL 2 WIDESPREAD EXFOLIATION CORROSION ON LONGITUDINAL BEAM AT FR68, Y1162.5. REPLACED LONGITUDINAL BEAM AT FR68, Y1162.5 IAW A320 SRM 53-00-14, 51-42-11 & 51-72-11.SDR USAA2011062300006Floorbeam · corrodedBFM - C3 - LEVEL 2 WIDESPREAD EXFOLIATION CORROSION ON LONGITUDINAL BEAM BETWEEN FR66 TO FR68, Y1292. REPLACED LONGITUDINAL BEAM BETWEEN FR66 TO FR68, Y1292 IAW A320 SRM 53-00-15, 51-73-00, 51-21-1 & 51-75-12.SDR USAA2011062300005Floorbeam · corrodedBFM - C3 - LEVEL 2 EXFOLIATION CORROSION ON LONGITUDINAL BEAM AT FR66, Y1292. REPLACED LONGITUDINAL BEAM AT FR66, Y1292 IAW A320 SRM 53-00-14, 51-74-00, 51-42-11 & 51-75-12.SDR DALA1139736802Floorbeam · corrodedDURING PSV IN ATL, MAINT NOTED CORROSION TO THE UPPER CAP OF THE FLOORBEAM AT STA 1640. SUBJECT CAP WILL BE CUT FROM LBL 13 TO THE RT END. A REPLACEMENT CAP WILL BE SPLICED INTO THE WEB AND THE REMAINING UNDAMAGED SECTION. SUBJECT CAP IS 7075-T6511, EXTRUSSDR SWAA114324Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 24.8. REPAIRED CHORD PER EA.SDR SWAA114323Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND T-CAP CORRODED AT BS 986, BETWEEN LBL 5 TO RBL 14. REPAIRED T-CAP PER SRM.SDR SWAA114315Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED AT BS 709, LBL 0.07. REPAIRED WEB PER SI.SDR SWAA114282Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND T-CAP CORRODED AT BS 986, RBL 14. REPAIRED T-CAP PER SRM.SDR SWAA114281Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND T-CAP CORRODED AT BS 986, RBL 5. REPAIRED T-CAP PER SRM.SDR SWAA114280Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND T-CAP CORRODED AT BS 986, LBL 5. REPAIRED T-CAP PER SRM.SDR SWAA114277Structure · corrodedDURING SCHEDULED 8Y CHECK, FOUND AFT CARGO COMPARTMENT FLOOR STRUCTURE CORRODED AT BS 727E+6, LBL 6. REPAIRED STRUCTURE PER SRM.SDR A6WA201140638Floorbeam · crackedLT FS 484, CLIP CRACKED AT LBL 27.0. R & R LT FS 484 CLIP IAW SRM 51-42-06 & 51-42-21.SDR USAA2011062200011Floorbeam · corrodedBFM - C3 - LEVEL 2 EXFOLIATION CORROSION ON LONGITUDINAL FLOORBEAM BETWEEN FR66 TO FR68, -Y1292. REPLACED LONGITUDINAL FLOORBEAM BETWEEN FR66 TO FR68, -Y1292 IAW A320 SRM 53-00-14, 51-42-11 & 51-75-12.SDR USAA2011062200010Floorbeam · corrodedBFM - C3 - LEVEL 2 EXFOLIATION CORROSION ON LONGITUDINAL FLOORBEAM AT FR68, -Y1162.5. REPLACED LONGITUDINAL FLOORBEAM AT FR68, -Y1162.5 IAW A320 SRM 53-00-14, 51-42-11 & 51-75-12.SDR ASOA201101171Angle · corrodedANGLE THAT FLOORBOARD 141 ALF ATTACHES TO ON FS 280 RIB IS CORRODED. R & R CORRODED ANGLE IAW SRM 51-42-06,51-42-13 & 51-42-21.SDR UALA2011061402929Floorbeam · corrodedCORROSION AT FLOORBEAM STA 365 AT RBL 38. MAJOR REPAIR ACCOMPLISHED: CORROSION WAS BEYOND SRM LIMITS & THE UPPER CHORD OF THE FLOORBEAM REQUIRED REPLACEMENT PER THE INSTRUCTIONS ON PEMCO EA PD57-53-137 WITHOUT DEVIATION. THIS IS CONSIDERED A PERMANENT REPAISDR FDEA201106122213Floorbeam · corrodedMDC UNDERFLOOR TEE HAS 1 SQ INCH OF CORROSION FWD OF SEAT TRACK NR LT AT FR 12A. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. REMOVED AND REPLACED TEE FWD OF SEAT TRACK NR 3 AT FR 12A IAW SRM 51-72- 10.SDR FDEA201106112206Floorbeam · corrodedCTR CARGO, AFT WALL FLOORBEAM ANGLE CORRODED ON AFT SIDE (AS VIEWED FROM AFT CARGO). R & R LT FLOORBEAM ANGLE SECTION, REF AFA3871, CLEANED AND TREATED CTR AND RT FLOORBEAM ANGLE SECTIONS, REF SRM 51-21-01, VOL II, LT FLOOR SUPPORT ANGLE 13 CORRODED BEYOND RSDR UALA2011061302879Floorbeam · corrodedCORROSION AT CABIN FLOOR SUPPORT SHEAR TIE STA 1681.8, BL 0 - RBL 40. MAJOR REPAIR. REPAIRED AFT DECK WEB AT STATION 1680 - 1690 RBL 27-53 IAW EA PD 57-53-134.SDR JR2R2011061100260Floorbeam · corrodedRIGHT 280 BEAM CORRODED.SDR JR2R2011061100259Floorbeam · corrodedLEFT 280 BEAM CORRODED.SDR DALA1138980669Floorbeam · corrodedDURING HMV CORROSION WAS FOUND ON FLOOR CABIN BEAM STA 1640 TOP SURFACE. REMOVED FABRICATED AND INSTALLED NEW T-CHORD AND ANGLE IAW SRM 53-00-51 FIG 201 REPAIR 3.SDR DALA1138960669Floorbeam · corrodedDURING HMV CORROSION WAS FOUND ON CABIN FLOORBEAM STA 1660 RBL 50. FLOORBEAM WAS REPAIRED IAW SRM 53-00-51 FIG 201 REPAIR 5.SDR SWAA114227Floorbeam · crackedDURING SCHEDULED 16Y CHECK FOUND, LONGITUDINAL FLOORBEAM WEB CRACKED AT BS 639, RBL 45.5. REPAIRED WEB PER ER AND EA.SDR SWAA114207Floorbeam · corrodedDURING SCHEDULED 6Y CHECK FOUND, AFT CARGO FLOORBEAM JOGGLE HOLES CORRODED AT BS 772, RBL 8. REPAIRED BEAM PER EA.SDR SWAA114206Floorbeam · corrodedDURING SCHEDULED 6Y CHECK FOUND, AFT CARGO FLOORBEAM JOGGLE HOLES CORRODED AT BS 772, LBL 18. REPAIRED BEAM PER EA.SDR SWAA114205Floorbeam · corrodedDURING SCHEDULED 6Y CHECK FOUND, AFT CARGO FLOORBEAM JOGGLE HOLES CORRODED AT BS 772, LBL 13. REPAIRED BEAM PER EA.SDR SWAA114204Floorbeam · corrodedDURING SCHEDULED 6Y CHECK FOUND, AFT CARGO FLOORBEAM JOGGLE HOLES CORRODED AT BS 772, LBL 8. REPAIRED BEAM PER EA.SDR SWAA114203Floorbeam · corrodedDURING SCHEDULED 6Y CHECK FOUND, AFT CARGO FLOORBEAM JOGGLE HOLES CORRODED AT BS 772, LBL 3. REPAIRED BEAM PER EA.SDR AALA20110610TUL03Floorbeam · damagedFLOORBEAM AT STATION 1309 HAS TOOLING DAMAGE AT UPPER FORWARD RADIUS AND AN ELONGATED HOLE FROM INTERCOSTAL REMOVAL (CENTER-LINE OF A/C). INSTALLED REPAIR DOUBLER PER EA MD80-017424.
Back to JASC 5315