What was found
CTR CARGO, AFT WALL FLOORBEAM ANGLE CORRODED ON AFT SIDE (AS VIEWED FROM AFT CARGO). R & R LT FLOORBEAM ANGLE SECTION, REF AFA3871, CLEANED AND TREATED CTR AND RT FLOORBEAM ANGLE SECTIONS, REF SRM 51-21-01, VOL II, LT FLOOR SUPPORT ANGLE 13 CORRODED BEYOND REPAIR, FABRICATED FLOORBEAM ANGLE IAW DWG AFA 3871.