JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011031791127Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66 + 5 INCHES TO FR67 + 15 INCHES, -Y1292. REPLACED FLOORBEAM BETWEEN FR66 + 5 INCHES TO FR67 + 15 INCHES, -Y1292 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2011031791126Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR64 TO FR67, -Y512. REPLACED FLOORBEAM BETWEEN FR64 TO FR67, -Y512 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472816.SDR USAA2011031791125Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66 + 5 INCHES TO FR70, Y765. REPLACED FLOORBEAM BETWEEN FR66 + 5 INCHES TO FR70, Y765 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2011031791124Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 FILIFORM CORROSION ON FLOORBEAM AT FR66, S23L, Y1292. REPLACED FLOORBEAM AT FR66, S23L, Y1292 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR SWAA111870Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND CORROSION ON UPPER CHORD FLOORBEAM FWD PAX COMPARTMENT, STA 344, BETWEEN LBBL 10 AND RBBL 10. REPAIRED CHORD PER SRM.SDR SWAA111838Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACK, BETWEEN STA 708 AND STA 710, BL 0. REPAIRED PER SI.SDR DALA1116439877Floorbeam · crackedRT FLOOR STUB BEAM UPPER CHORD AND WEB CRACKED FWD AND AFT SIDES STA 712 UNDER CUSP WEB AREA. REMOVED, FABRICATED, RT FLOOR STUB BEAM WEB, IAW SRM 51-30-3, PG 19 AND DWG 9923410, TREATED AND PRIMED WEB IAW SRM 51-10 -4, PG1 AND INSTALLED WEB IAW SRM 51-30SDR SWAA111524Floorbeam · crackedDURING SCHEDULED 18Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 664, RBL 24.5. REPAIRED CHORD PER EA.SDR SWAA111523Floorbeam · crackedDURING SCHEDULED 18Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 24.8. REPAIRED BEAM PER EA.SDR U2RA478DHN011Floorbeam · damagedSTA 1640, RBL 56, TOOLING DAMAGE BELOW FLOORBEAM NEAR HI-LOCK COLLAR.SDR ASOA201100451Floorbeam · crackedFS 280 WEB CRACKED OTBD OF RBL 9 APPROX .250". FLOORBEAM CLIPS INBD OF LBL 9 AND RBL 9 ARE CRACKED. OTBD OF LBL 9 CRACKED.SDR ASOA201100445Floorbeam · crackedFS 280.0 FLOORBEAM CLIPS CRACKED AT RBL 9 AND LBL 9. REMOVED AND REPLACED FLOORBEAM FWD CLIPS IAW SRM 51-42-21, REO 60R-53-11-2088 & REO 601R-53-11-926.SDR ASOA201100437Floorbeam · corrodedFLOOR PANEL 141ALF FORWARD SUPPORT ANGLE AT FS 280 IS CORRODED. REMOVED PANEL 161ALF IAW SRM 51-41-02. OK TO INSTALL, INSTALLED PNL 131ALF IAW SRM 51-41-02. REMOVED CORRODED SUPPORT ANGLE FROM FRAME AT FS 280 LBL 9 TO RBL 9 IAW SRM 51-42-06. LOCATED,DRILLESDR DALA1116149870Floorbeam · chafedMAIN CABIN STA 294 RBL 3 TO 19 FLOORBEAM CHAFED. REMOVED REPAIR STRAP IAW DC9 SRM 51-30-1. FABED NEW IAW DC9 SRM 53-05. PRIMED IAW DC9 SRM 51-10-3. BLENDED FLOORBEAM RBL 3-19 CHAFED AND FOUND TO BE WITHIN LIMITS IAW DC9 SRM 53-01. ORG THICKNESS .125 REMOVSDR IPXA1565841Floorbeam · damagedINSPECTION TYPE:C3, MCB FLOORBEAM HAS AREAS OF MECHANICAL DAMAGE ON UPPER SURFACE, BS 1100, WL 208, LBL 2 TO LBL 40 (MARKED). REPAIRED FLOORBEAM IAW ER 11-01830 AND EO B757-5310-42081-A.SDR IPXA1565840Floorbeam · gougedINSPECTION TYPE:C3, MAIN CARGO BAY THE UPPER FLANGE OF THE BS 1200 FLOORBEAM IS GOUGED LBL 60-RBL 60, WL 208. REPAIRED FLOOR BEAM IAW ATS WE11-01829 AND EO B757-5310-42083-A.SDR IPXA1565732Floorbeam · corrodedINSPECTION TYPE:C3, FLOOR SUPPORT HAS CORROSION ON UPPER SURFACE, BS 1055, LBL46-57, WL 208. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G.SDR IPXA1565722Floorbeam · damagedINSPECTION TYPE:C3, FLOORBEAM HAS MECHANICAL DAMAGE BS 1054 RBL 1 TO RBL 24. R & R FLOORBEAM IAW SRM 51-40-02-0G.SDR IPXA1565721Floorbeam · damagedINSPECTION TYPE:C3, FLOORBEAM HAS MECHANICAL DAMAGE BS 1020 RBL 1 TO RBL 24 R & R FLOORBEAM IAW SRM 51-40-02-0G.SDR IPXA1565720Floorbeam · damagedINSPECTION TYPE:C3, FLOORBEAM HAS MECHANICAL DAMAGE BS 1020, RBL 25.5 TO RBL 44.5. R & R FLOORBEAM IAW SRM 51-40-02-0G.SDR SWAA111835Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND UPPER CHORD OF FLOORBEAM AT STA 727B, LBL 24.8 CENTER CABIN FLOOR STRUCTURE CRACKED. REPAIRED BEAM PER EA.SDR SWIA201125766Floorbeam · crackedFS 280 FLOORBEAM IS CRACKED ON BOTH SIDES. (C-CHECK) REPLACED FLOORBEAM PER SRM.SDR IPXA11565186Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY 1540 FLOORBEAM UPPER AFT FLANGE IS CORRODED AT LBL 37, WL 208. VALIDATED REPAIR IAW SRM 53-60-51-1A, FIG 1 AND 53-00-51-1A, FIG 101. REMOVED CORROSION L1.75" X 2.0"W X .002" D ORIGINAL THK .220", REMAINING THK .218" AT BS 15SDR IPXA11565185Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 719, LBL 1. VALIDATED REPAIR IAW SRM 53-00-51-1A-1. REMOVED CORROSION 15" W X 1.5"L ORIGINAL THK .220", REMOVED .022" REMAINING THK .198" AT BS 720, RBL 27 TO RBL 42 IAW 51-10-02SDR IPXA11565183Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1681 FLOORBEAM NUT PLATE STRAP IS CORRODED RBL 52, WL 207 ON FWD UPPER FLANGE LOWER SIDE. AFTER INVESTIGATION NO ALLOWABLE DAMAGE AVAILABLE IN SRM FOR NUT PLATE STRAP. REMOVED NUT PLATE STRAP AT BS 1681, RBL 52, WL 207 ISDR IPXA11565182Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1540 FLOORBEAM UPPER AFT FLANGE IS CORRODED RBL 36.5 AND 40 WL 208. VALIDATED REPAIR IAW SRM 53-60-51-1A, FIG 1 AND 53-00-51-1A, FIG 101. REMOVED CORROSION L2.5" X 1.5" WX.002D ORIGINAL THICKNESS .220". REMAINING THICKNESDR DALA1115709878Floorbeam · corrodedFORWARD WET AREA STA 160 LBL 49-52, FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION MATERIAL LOSS OUT OF LIMITS IAW SRM 53-01. REMOVED FLOOR SUPPORT IAW SRM 51-30-02. FABBED NEW SUPPORT IAW SRM 51-10-04. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-30-02. P180.SDR UALA2011030701093Bolt · shearedBOLT SHEARED THAT APPEARS TO ATTACH FLOORBEAMS TOGETHER. LOCATION IS AFT PIT, FWD WALL, ABOVE UPPER RT CORNER. REPLACED BOLT FOR FLOORBEAMS. REINSTALLED FLOOR AND SIDE WALL PANELS.SDR CALA2011030700125Floorbeam · corrodedCABIN - BS303 LBL20-30 FLOOR SUPPORT FOUND CORRODED CABIN BS303 LBL20-30 FLOORBEAM UPPER CHORD CORROSION REMOVED OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT AND FLOORBEAM UPPER CHORD CORRODED AREA REPAIRED AS PER SRM 53-00-51 FIG 201 REPAIR 1 AT BS 30SDR DALA1115699878Floorbeam · crackedMAIN CABIN STA 636 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CRACKED AND HAS CORROSION. REMOVED CRACKED FLOOR SUPPORT AND FABRICATED NEW FROM IAW SRM 53-13-2, FIG 4 LOCATED AND DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3 INSTALLED IAW SRM 51-30-5SDR DALA1115659878Floorbeam · chafedMAIN CABIN STA 636 BETWEEN BL-0 AND LBL-22 TOP FLOORBEAM CHAFED. CORRECTED, REMOVED PREVIOUS REPAIR, STAINLESS STEEL STRIP AND FABRICATED NEW IAW SRM 53-05 FIG 20. LOCATED AND DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 53-SDR V0XR413Y030511003Floorbeam · corrodedFS 280.00 FROM LBL 9 TO RBL 9 CORRODED FLOOR CHANNEL SUPPORT. REMOVED FLOOR CHANNEL SUPPORT FS 280.00 IAW SRM 51-42-06. REPLACED FLOOR CHANNEL SUPPORT FS 280.00 IAW SRM 53-11-10. INSTALLED FLOOR CHANNEL SUPPORT FS 280.00 IAW SRM 51-42-06.SDR USAA2011040491323Floorbeam · crackedCLT - Q5/QX6 - CRACKS ON FLOORBEAM BETWEEN BS 658 TO BS 668, RBL 24.8. REPAIRED FLOORBEAM BETWEEN BS 658 TO BS 668, RBL 24.8 IAW EA 102736.SDR UALA2011030401072Floorbeam · corrodedCORROSION ON TOP OF FLOORBEAM AT STA 324 RBL 51- RBL 55. ACCOMPLISHED REPAIR OF FLOOR BEAM IAW PD57-53-093 AND EVA 80627.SDR UALA2011030701089Floorbeam · crackedFLOORBEAM WEB CRACKED, MAIN DECK STA 2020 LBL 108. MAJOR REPAIR ACCOMPLISHED: REMOVED STIFFENERS. FABRICATED AND INSTALLED NEW STIFFENERS IAW 747EN-53-0328.SDR CALA2011030700123Floorbeam · corrodedCABIN - BS 325 LBL 23-59 FLOOR SUPPORT FOUND CORRODED CABIN BS 325 LBL 23"-59" FLOORBEAM UPPER CHORD CORROSION REMOVED OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT AND FLOORBEAM CORRODED UPPER CHORD REPAIRED AS PER SRM 53-00-51 FIG 201 REPAIR 1 AT BS 3SDR FDEA201103030833Floorbeam · misalignedSTA 700 INCOMING REPAIR AT RBL40 WILL INTERFERE WITH PTF MOD. R & R FLOORBEAM AT STA 700, BETWEEN RBL 70 TO LBL 70". BAC1518-338/18A, BATCH NR 0001922129, IAW SRM 53-30-51, FIG 1, PAG-4 AND SRM 51-40-02, AND REINSTALLED ATTACH PARTS, FROM ITEM 3 THRU 12, IAWSDR FDEA201103030830Floorbeam · corrodedCORROSION TOP TEE CAP FLOORBEAM MAIN CABIN STA 620 BL 0 - LBL 25. WORK ACCOMPLISHED ON NR N00384 AND SDR 11-0817.SDR FDEA201103030831Floorbeam · corrodedCORROSION TOP TEE CAP FLOORBEAM MAIN CABIN STA 560 LBL 25 - LBL 45. CUTOUT DAMAGED AREA, FABRICATED 2 ANGLES AND FILLER, TREATED AND PRIME PARTS AND AREA, INSTALLED FLOORBEAM REPAIR AT BS 560 BETWEEN LBL 25 - LBL 45 IAW SRM 53-10-8, FIG 8 AND SRM 51-30-5, SRMSDR DALA1116349870Floorbeam · chafedMAIN CABIN STA 655 BETWEEN BL-0 AND LBL-22 FLOORBEAM CHAFED ON TOP SIDE. BLENDED AREA IAW SRM 53-01. ORIGINALTHICKNESS WAS .125 IAW SRM 53-13-2, AFTER BLEND THICKNESS IS .073 OUT OF LIMITS IAW SRM 53-01. FABRICATED 5 EA REPAIR PLATES IAW SRM 53-05, FIG 20. SDR DALA1116339870Floorbeam · chafedMAIN CABIN STA 636 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CHAFED. CORR BY FILLING IM 316479 BLENDED SUPPORT IAW SRM 51-10-3. ORIGINAL THICKNESS WAS .050 IAW SRM 53-13-2, AFTER BLEND THICKNESS IS .027 OUT OF LIMITS IAW SRM 53-01, FIG 1 FABBED NEW SUPPORT IAW SSDR COEA2011030301903Floorbeam · damagedHEAVY CHECK / COE / MAJOR REPAIR: WHILE WORKING REPAIR ON LONGITUDINAL FLOORBEAM AT FR 26 & 25.5 RBL FOUND INTERSECTING FASTENER HOLES IN TOP FLANGE OF FLOORBEAM 26. REPAIRED PER SRM / COMPLEX BUT CONSIDERED MINOR REPAIR.SDR ASAA1149130Floorbeam · corrodedCORROSION ON FUSELAGE FLOORBEAM BS 986.5 LBL 20 AND RBL 45. REPAIRED FLOORBEAM IAW ASA EA 400 53EA 04881.SDR FDEA201103020825Floorbeam · corrodedCENTER CARGO COMPARTMENT FLOORBEAM CORRODED/EXFOLIATED AT BS 1781, RBL 36.SDR FDEA201103020817Floorbeam · corrodedCORROSION TOP TEE FLOORBEAM MAIN CABIN STA. 620 LBL 25 - LBL 45. CUTOUT DAMAGED AREA IAW SRM 53-10-8 FIG 3. FABRICATED REPAIR PARTS IAW SRM 53-10-8 FIG 3. TREATED & PRIMED AREAS IAW SRM 51-10-2, INSTALLED REPAIR PARTS IAW SRM 53-10-8 FIG 3, INSTALLED STIFFESDR DALA1114829878Floorbeam · crackedMAIN CABIN STA 775 BETWEEN BL-0 AND RBL-22 FLOOR SUPPORT CRACKED AND HAS CORROSION. REMOVED CORROSION FROM FLOOR SUPPORT IAW SRM 51-10-3.ORG MAT THICKNESS .050 IAW SRM 53-13-3. REMOVED.003 REMAINING .047 IN LIMITS IAW SRM 53-01. REMOVED CRACKED FLOOR SUPPORSDR DALA1114789877Floorbeam · corrodedFLOORBEAM JUST LEFT OF AC CENTER BEAM AT STA 200 HAS CORROSION. REMOVED CORROSION ON UPPER FLANGE ON FLOOR PANEL BEAM AT STA 200 FROM X1 TO X 20, DAMAGE FOUND OUT OF LIMITS IAW DC-9 SRM 53-01 PARA 3 SHEET 3 FIG 1. REMOVED AND REPLACED FLOOR PANEL BEAM SUPPORSDR DALA1114769873Floorbeam · crackedMAIN PASSENGER CABIN-FLOOR SUPPORT CRACKED STA 617 LBL1 TO LBL18. REMOVED CRACKED FLOOR SUPPORT/ZEE IAW SRM 51-30-2. FABRICATED NEW FLOOR SUPPORT/ZEE FROM .050 2024T3 PO 1120351 IAW SRM 53-13-3 FIG 4 SHEET 1 AND 2 AND 51-10-4. INSTALLED NEW FLOOR SUPPORT/ZSDR DALA1115289870Floorbeam · corrodedMAIN CABIN STA 200, RBL 24 TO 43 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3. ORIGINAL THICKNESS WAS .060 IAW SRM 53-13-1, FIG 11, AFTER BLEND MATERIAL THICKNESS IS .010 OUT OF LIMITS IAW SRM 53-01. REMOVED SUPPORT IAW SRM 51-30-5. FABRISDR DALA1115279870Floorbeam · corrodedMAIN CABIN STA 200, LBL 1 TO 20, FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION, MATERIAL LOSS FOUND TO BE MORE THAN 50 PERCENT, REMOVED FLOOR SUPPORT. RECEIVED NEW PN 52652479, TRIMMED, LOCATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW SUPPORT IA
Back to JASC 5315