JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201100485Floorbeam · corrodedCARGO BAY FLOORBEAM CAP AT LBL27 IS CORRODED. R & R FLOORBEAM CAP IAW SRM 51-42-06 AND 51-42-21. MAJOR REPAIR.SDR ASOA201100481Floorbeam · crackedFLOORBEAM STRUCTURE AT FS 589.0 OTBD IS CRACKED AT CARGO DOOR SEAL PLATE. R & R FLOORBEAM AT FS 589 IAW SRM 51-42-06 AND 51-42-21. MAJOR REPAIR.SDR ASOA201100480Floorbeam · corrodedFS 349.00 OTBD OF LBL 27 HAS CORRODED HARDWARE, FLOOR SUPPORT STRUCTURE. REMOVED UNSERVICABLE HARDWARE AND INSTALLED SERVICABLE HARDWARE IAW SRM 51-42-13.SDR REXA201100174Floorbeam · corrodedFLOORBEAM LBL 27 HAS MINOR CORROSION BETWEEN FS 574 AND 621. REPAIRED IAW SRM 51-42-21, 51-42-22, REO 601R53-61-3778.SDR SWAA111788Floorbeam · crackedDURING SCHEDULED 24Y CHECK, FOUND LONGITUDINAL FLOORBEAM CRACKED AT BS 708, RBL 24.5. REPAIRED BEAM PER EA.SDR SWAA111781Floorbeam · corrodedDURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED AT BS 270, BETWEEN LBL 270 TO RBL 10. REPAIRED BEAM PER EA.SDR CALA2011032500195Floorbeam · corrodedAFT FUSELAGE FLOORBEAM AT STA1681 LBL 53 HAS CORROSION UPPER AND UNDER SIDER TEE. REPAIR FLOORBEAM AT STA 1681 LBL 53 REF EC/RA 5310-05356.SDR CALA2011032500189Floorbeam · corrodedCABIN BS 325 LBL 21 TO 55 FLOORBEAM CORRODED. CABIN BS 325 LBL 62.5 - RBL 9 FLOORBEAM UPPER CHORD REPLACED AS PER SRM 53-00-51 FIG 201 REPAIR 1 AND HFEC NIL CRACK CHECK AFT MAINTENANCE.SDR USAA2011032391192Floorbeam · corrodedPIT - C11/SY6 - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FR66, -Y1292. REPLACED FLOORBEAM AT FR66, -Y1292 IAW A320 SRM 51-72-11.SDR USAA2011032391190Floorbeam · corrodedPIT - C11/SY6 - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68 & BETWEEN Y1160 TO Y1292. REPLACED FLOORBEAM BETWEEN FR66 TO FR68 & BETWEEN Y1160 TO Y1292 IAW A320 SRM 51-72-11.SDR USAA2011032391189Floorbeam · corrodedPIT - C11/SY6 - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69, Y1160. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, Y1160 IAW A320 SRM 51-72-11.SDR USAA2011032391188Floorbeam · corrodedPIT - C11/SY6 - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR66 TO FR67, -Y1292. REPLACED FLOORBEAM BETWEEN FR66 TO FR67, -Y1292 IAW A320 SRM 51-72-11.SDR USAA2011032391187Floorbeam · corrodedPIT - C11/SY6 - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69, -Y1292. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, -Y1292 IAW A320 SRM 51-72-11.SDR USAA2011032391186Floorbeam · corrodedPIT - C11/SY6 - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66, Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR66, Y1292 IAW A320 SRM 51-42-11 & EA 117441.SDR SWAA111703Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 663, RBL 24.5. REPAIRED BEAM PER EA.SDR SWAA111702Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 658, RBL 24.5. REPAIRED BEAM PER EA.SDR SWAA111701Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 669, LBL 24.5. REPAIRED BEAM PER EA.SDR SWAA111700Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 665, LBL 24.5. REPAIRED BEAM PER EA.SDR SWAA111699Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 658, LBL 24.5. REPAIRED BEAM PER EA.SDR SWAA111675Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 663, BL 0. REPAIRED BEAM PER SRM.SDR SWAA111674Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 661, BL 0. REPAIRED BEAM PER SRM.SDR SWAA111590Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORRODED AT BS 344, RBL 1. REMOVED AND REPLACED BEAM SECTION PER SRM.SDR USAA2011040891379Floorbeam · corrodedPIT - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, -Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, -Y765 IAW A319 SRM 53-41-14.SDR USAA2011040891378Floorbeam · corrodedPIT - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR65 TO FR66, -Y464. REPLACED FLOORBEAM BETWEEN FR65 TO FR66, -Y464 IAW A319 SRM 52-41-11.SDR USAA2011040891377Floorbeam · corrodedPIT - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR70, Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR70, Y765 IAW A319 SRM 53-00-14.SDR FDEA201103110938Floorbeam · corrodedCORROSION TOP TEE CAP FLOORBEAM MAIN CABIN STA 420, RBL 45 TO RBL 61. REMOVED CORROSION FROM FLOORBEAM IAW SRM 51-10-6 ORIG MAT. .125, LOSS, MAT. .015, REM MAT. .110, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1, FIG 4B. CUTOUT DAMAGE AREA FABRICATED FILLER, FASDR F3LA2011031500613Floorbeam · corrodedACFT C-CHECK: NON ROUTINE NR 31644; MAIN CABIN FLOORBEAM HAS CORROSION 6" OF FR 66, Y 1732. CORROSION NOTED IS EXFOLIATION AND OUT OF LIMITS IAW SRM 53-41-14 P 103/104, R & R FLOORBEAM ASSY.SDR A6WA201140223Floorbeam · crackedCRACK AT STA 280 IN FLOORBOARD SUPPORT AT APPROX 12 LBL CUT AWAY DAMAGE SECTION AT STA 280 IN FLOORBOARD SUPPORT ANGLE AND INSTALLED NEW REPAIR ANGLE AND SPLICE ANGLES IAW REO 601R-53-11-138, REV A.SDR DALA1125170687Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 345 FROM LBL 60 TO RBL 60. REPAIRED FLOORBEAM IAW 51-40-02.SDR DALA1125150687Floorbeam · corrodedCORRODED FLOORBEAM UPPER SURFACE ON LBL 3, STA 1640. REPAIRED FLOORBEAM UPPER SURFACE IAW SRM 53-00-51 REPAIR 3 FIG 201.SDR DALA1125140687Floorbeam · corrodedCORROSION ON MAIN DECK FLOORBEAM BS 700 FROM RBL 15 TO LBL 62. REPAIRED FLOORBEAM IAW SRM 53-00-51 FIG 201.SDR DALA1125130687Floorbeam · corrodedCORROSION ON MAIN DECK FLOORBEAM BS 680 LBL 18.5. REPAIRED FLOORBEAM IAW SRM 53-00-51 REPAIR III.SDR IPXA1B65791Floorbeam · corrodedINSPECTION TYPE:D, BULK CARGO COMPT STA 2044 LBL53" TO RBL53" FLOORBEAM CORRODED. STA 2044, LBL 53- RBL 53 FLOORBEAM REPLACED IAW SRM 51-10-02, REV 18 AND INSTALLED IAW SRM 51-40-02, REV 18, PN 69B03459-2.SDR SWAA111877Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND CRACK IN LONGITUDINAL FLOORBEAM, STA 727B, RBL 24.5. REPAIRED PER EA/ER.SDR ASOA201100463Floorbeam · corrodedFS 280 TRANSVERSE BEAM FWD "J" CHANNEL CORRODED FROM LBL 9 TO RBL 9. INSTALLED NEW CHANNEL IAW SRM 51-42-06.SDR ASOA201100462Floorbeam · corrodedFS 280 TRANSVERSE BEAM UPPER AFT "J" CHANNEL IS CORRODED FROM LBL 18 TO RBL 36 AT SEVERAL LOCATIONS. FOUND TO BE WITHIN ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-00 AND REMOVED CORROSION IAW SRM 51-21-06.SDR ASOA201100461Floorbeam · corrodedFLOORBEAM AT FS 349.00 HAS CORROSION FROM RBL 27 TO RBL 36. REMOVED FLOORBEAM IAW SRM 51-21-06. REPAIRED FLOORBEAM THREATED FOR CORROSION PREVENTION IAW SRM 51-21-11, SRM 51-25-06 AND SRM 51-25-16. AND REINSTALLED IAW SRM 51-42-13, 51-42-15 AND 51-45-00.SDR DALA1117065521Floorbeam · corrodedAT LBL 62 BET FLOORBEAM STA 365 TO STA 377 BOX BEAM HAS CORROSION AS MARKED. REMOVED CORROSION, AFTER REWORK, DEPTH (.014) ORIGINAL MAT (.050) OUT OF LIMITS PER SRM 53-00-51, FIG 101 FABRICATED NEW BOX BEAM PER STAM TRAVELER T11/873094. INSTALLED BOX BEAM SUSDR FDEA201103090918Floorbeam · crackedMAIN CABIN OVERWING FLOORBEAM TEE CRACKED AT RADIUS BS 760.9 RBL 45. REMOVED MAIN CABIN OVERWING FLOORBEAM TEE, FABRICATED NEW TEE, AND INSTALLED IAW DWG 65-16279, SRM 51-30-2 AND 51-10-2.SDR SWAA111814Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORROSION AT STA 847+5, RBL 3 AT NUT PLATE HOLE. REPAIRED FLOORBEAM PER EA.SDR SWAA111813Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOOR BEAM CORROSION AT STA 847+5, RBL 8 AT NUT PLATE HOLE. REPAIRED FLOORBEAM PER EA.SDR SWAA111812Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORROSION AT STA 847+5, LBL 8 AT NUT PLATE HOLE. REPAIRED FLOORBEAM PER EA.SDR SWAA111811Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORROSION AT STA 847+5, LBL 3 AT NUT PLATE HOLE. REPAIRED FLOORBEAM PER EA.SDR SWAA111810Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORROSION AT STA 847+5, LBL 13 AT NUT PLATE HOLE. REPAIRED FLOORBEAM PER EA.SDR DALA1116735521Floorbeam · corrodedPREVIOUS REPAIR AT BS 1640 CORRODED AT 4 LOCATIONS BETWEEN LBL 15 AND LBL 60. REMOVED CORROSION AT STN 1640 FLOORBEAM PER SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101. REMOVED AND REPLACED UPPER CHORD AT BS 1640 FROM LBL 64 TO LBL 15 IAW SDR AALA20110309TUL03Floorbeam · corrodedSTATION 1661 CORROSION ON FLOORBEAM CAP AT RIGHT BUTTLINE 57. REPAIRED FLOORBEAM CAP AT STATION 1661 AT RIGHT BUTTLINE 57 IAW BOEING DRAWING LOR5L53005, AND EA 757-53-015670.SDR IPXA1B65792Floorbeam · corrodedINSPECTION TYPE:D, BULK CARGO COMPT, STA 2018, LBL 8" TO RBL 8" FROM PANEL SUPPORT SURFACE FOUND CORRODED. BULK CARGO COMPT STA 2018, LBL 8 TO RBL 8 FLOOR PANEL SUPPORT REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 18, PN 146U5092-13.SDR IPXA1B65789Floorbeam · corrodedINSPECTION TYPE:D, BULK CARGO COMPARTMENT, STA 2002, LBL 8" TO RBL 8" FLOOR PANEL SUPPORT SURFACE FOUND CORRODED BULK CARGO COMPARTMENT STA 2002, LBL 8 TO RBL 8 FLOOR SUPPORT REPLACED & INSTALLED IAW SRM 51-10-02 AND 51-40-02, REV 18, PN 146U5092-13.SDR USAA2011031791129Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR67 + 18 INCHES, -Y765. REPLACED FLOORBEAM AT FR67 + 18 INCHES, -Y765 IAW A320 SRM 51-72-11.SDR USAA2011031791128Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR67 + 15 INCHES TO FR69 + 4 INCHES, -Y1292. REPLACED FLOORBEAM BETWEEN FR67 + 15 INCHES TO FR69 + 4 INCHES, -Y1292 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.
Back to JASC 5315