SDR CALA0800850Floorbeam · corrodedCORROSION ON FLOORBEAM AT BODY STATION 270 FROM LBL 10 - RBL 10 LOCATED AT AFT SIDE OF NLG DOWNLOCK VIEWER PANEL. REPAIRED CORRODED FLOORBEAM AT BODYSTATION 270 FROM LBL 10 - RBL 10 LOCATED AT AFT SIDE OF NLG DOWNLOCK VIEWER PANEL PER CAL EC/RA5320-01701.SDR DHLA2008745667Floorbeam · crackedUPPER FUSELAGE MAIN CABIN STA 1130 LBL 8 WL 201 FLOORBEAM LOWER CHORD CRACKED. REPAIRED FUSELAGE FLOORBEAM UPPER CHORD SECTION AT BS 1130 FROM LBL 5 TO LBL 54 AND LOWER CHORD SECTION FROM LBL 67 TO RBL 67 DUE TO CORROSION AND CRACK IAW COOPESA EO COO-2-53-269SDR DHLA2008745585Floorbeam · corrodedUPPER FUSELAGE MAIN CABIN STA 1110 BETWEEN RBL 15 AND LBL 63 FLOORBEAM UPPER CHORD WITH CORROSION SEVERAL PLACES. REPAIRED FUSELAGE FLOORBEAM UPPER CHORD SECTION AT BS 1110 FROM LBL 13.750 TO RBL 70 IAW EO COO-2-53-272-08 DTD 9/14/08 DOCUMENTED ON FAA FORM 81SDR USAA920081775Floorbeam · corrodedCLT - MAJOR REPAIR - Q1 CHECK, LEVEL 2 CORROSION ON FLOORBEAM T-CAP, BS 312, LBL 34- RBL 22. REPLACED FLOORBEAM T-CAP , BS 312, LBL 34 - RBL 22 IAW UB737 SRM 53-10-51-2R5.SDR SWAA084859Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM CORRODED AT BS 1016, LBL 12. REPAIRED FLOORBEAM PER SRM.SDR HNAA2009012700031Floorbeam · corrodedDURING 'C' CHECK INSPECTIONS, AN UNRECORDED REPAIR AND CORROSION WAS DISCOVERED ON THE LT SIDE OF THE FLOOR BEAM LOCATED AT X270.5 AND Y9.25 UNDER THE SEAT RAIL. THE CORRODED FLOOR BEAM SECTION WAS REMOVED, REPAIR ANGLES AND A PACKER FABRICATED AND INSTALLED SDR USAA920081641Strap · crackedCLT Q1 MAJOR REPAIR NR 03C20553006/001. STRAP CRACKED ON LOWER PORTION OF FLOORBEAM AT BS312. BLO. REPLACED STRAP ON LOWER PORTION OF FLOORBEAM AT BS312, BLO IAW B737 SRM 51-10-02.SDR 08FDEA03703Floorbeam · corrodedFOUND CORROSION ON CROSSBEAM C 56 LT OUT OF LIMIT. SPLICE REPAIR PERFORMED IAW. SRM 53-10-15 FIG.207SDR SWAA084818Floorbeam · corrodedDURING SCHEDULED 8Y CHECK, FOUND FLOORBEAM CORRODED AT BS 986.5, RBL 5 TO RBL 43. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA084817Floorbeam · corrodedDURING SCHEDULED 8Y CHECK, FOUND FLOORBEAM CORRODED AT BS 328, RBL 11 TO RBL 36.5. REPAIRED FLOORBEAM PER SWA EA.SDR 2008UALA05559Floorbeam · corrodedCABIN FLOORBEAM FRAME CORRODED STA 284 RBL 17. *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF FLOORBEAM TEE AND FABRICATED A NEW TEE REPAIR ANGLE. DAMAGED T-CAP REMOVED BETWEEN RBL 17 - RBL 22 AND WL 208.
SDR 2008UALA05558Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP CORRODED AT BS 1502 AND LBL 28. *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF T-CAP. FABRICATED A-1 AND -2 REPAIR ANGLES, -3 STRAP AND 4 EACH SHIM AND INSTALLED.
SDR 2008UALA05557Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP CORRODED UNDER STEEL SUBFLOOR AT BS 1518 AT BL 0. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED T-CAP SECTION. FABRICATED AND INSTALLED A NEW T-CHORD, SPLICE ANGLES & SPLICE STRAPS.SDR 2008UALA05546Floorbeam · corrodedBEAM 255 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED BEAM. BEGAN INSTALLING FLOORBEAM 255 IN A/C. COMPLETED INSTALLATION OF FLOORBEAM 255. INSPECTED INSTALLATION OF BEAM 255 FOR SAFETY AND SECURITY.SDR SWAA084813Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM CORRODED AT BS 1016, LBL 12. REPAIRED FLOORBEAM PER SRM.SDR COMA086377Floorbeam · crackedRT FLOOR SUPPORT ANGLE AT STA 621 RBL 5 IS CRACKED. REPAIRED PER CRJ SRM 51-42-21 PG 1-21, SRM 51-42-06 PG 1-20 AND REO 601R-53-61-117 REV A.SDR COMA086374Floorbeam · crackedLT FLOOR SUPPORT ANGLE AT STA 621 LBL 45 IS CRACKED. PERFORMED REPAIR IAW REO 601R-53-61-117 REV A.SDR USAA920081602Floorbeam · corrodedSAL C19 MAJOR REPAIR NR 6097669 CORROSION ON FLOORBEAM BETWEEN BS 986.5 & BS 1006, RBL 15. REPAIRED FLOOR BEAM BETWEEN BS 986.5 & BS 1006, RBL15 IAW B737 SRM 53-00-51-2R.SDR 2008UALA05532Floorbeam · corrodedFLOORBEAM 250 CORRODED (MARKED). ALSO HAS 8 EA SHEARED FASTENERS ON OUTBOARD SIDE OF BEAM (MARKED). MAJOR REPAIR ACCOMPLISHED. BEAM REMOVED, TRANSFERRED FASTENER HOLES TO NEW BEAM. BEGAN INSTALLING FLOORBEAM 250 IN AC. COMPLETED INSTALLATION OF FLOORBEAM SDR CALA0800839Floorbeam · corrodedAFT CARGO STATION 773 RBL 13.84 FLOOR SUPPORT HAS MILD CORROSION. FABRICATED AND INSTALLED REPAIR PER ECRA 5321-01562.SDR SWIA200820450Floorbeam · crackedC-CHECK, FLOOR SUPPORT ATTACH CLIPS AT FS 280 RBL 9 CRACKED. REPLACED PER SRM.SDR SWIA200820449Floorbeam · crackedC-CHECK, FLOOR SUPPORT ATTACH CLIP AT FS 280 LBL 9 CRACKED. REPLACED PER SRM.SDR KCSA081427Floorbeam · crackedAFT BILGE FLOOR BEAM UPPER CHORD IS CRACKED AT STA 2100, RBL 23.SDR 2008UALA05502Floorbeam · corrodedFLOORBEAM 225 CORRODED AROUND FWD NUT PLATE HOLE (MARKED). MAJOR REPAIR ACCOMPLISHED: REMOVED BEAM, DRILLED BEAM AND ATTACH ANGLES. INSTALLED FLOORBEAM 225 IN A/C.SDR 2008UALA05505Floorbeam · damagedMAIN CABIN, BLEND OUT ON UPPER CHORD OF BS 1661 FLOORBEAM AT RBL 60. *S/D* MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED AREA. FABRICATED & INSTALLED A NEW T-SECTION AND SPLICES.SDR 2008UALA05485Floorbeam · corrodedFLOORBEAM 245 CORRODED (MARKED). MAJOR REPAIR ACCOMPLISHED. REMOVED BEAM. TRANSFERRED ATTACHING PARTS AND IS READY FOR FIT INTO AC. BEAM INSTALLED. INSPECTED THE INSTALLATION OF BEAM 245 FOR SECURITY AND FOUND SECURE.SDR 2008UALA05474Floorbeam · corrodedFLOORBEAM 235 CORRODED (MARKED). MAJOR REPAIR ACCOMPLISHED. INSTALLED TIE DOWN FITTINGS FOR LAV AND GALLEY MODULES ONTO NEW FLOORBEAM 235. FITTED BEAM 235 TO ACFT (PICKED UP HOLES) AND FITTED 2EA. NEW SPLICES AT FWD END OF BEAM 235. INSTALLED FLOORBEAM 23SDR SWAA084687Floorbeam · corrodedDURING SCHEDULED 8Y CHECK, FOUND FLOORBEAM TEE CAP CORRODED AT BS 986.5, BETWEEN RBL 14 AND LBL 40. REPAIRED TEE CAP PER SWA EA.SDR COMA086361Floorbeam · crackedFLOOR SUPPORT FRAME JUST O/B OF RBL9 AT FS280 IS CRACKED ON LWR AFT SIDE. CORRECTIVE ACTION: CUT OUT DAMAGE AND INSTALLED PERMANENT REPAIR PARTS PER REO 601R-53-11-171.SDR 2008UALA05448Floorbeam · corrodedFLOOR BEAM 205 IS CORRODED (MARKED). *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 205. REMOVED ANGLES, WORKING ON BENCH. INSTALLED GALLEY ATTACH POINTS, DRILLED NEW SPLICE ANGLES. INSTALLED NEW SPLICE ANGLES.SDR 2008UALA05447Floorbeam · corrodedFLOORBEAM 200 IS CORRODED (MARKED). MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 200. REMOVED ANGLES ATTACHED TO BEAM 165, DRILLED SPLICE ANGLES FOR BEAM 200 TO 205. COMPLETED INSTALLATION.
SDR 2008UALA05446Floorbeam · corrodedFLOORBEAM 165 CORRODED (MARKED). MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 165. REMOVED ANGLES. TRANSFERRED BRACKETS AND ATTACHED BEAM 165 AND 200 WITH SPLICE ANGLES WORKING ON BENCH. COMPLETED INSTALLATION.SDR 2008UALA05445Floorbeam · corrodedFLOORBEAM 210 IS CORRODED (MARKED). MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 210. TRANSFERRED ATTACH BRACKETS AND STARTED ATTACHING TO BEAM 175. BEAMS 210 AND 175 ARE TOGETHER AND NEED THE FWD END DRILLED TO BRACKETS IN A/C. PICKED UP REMAINING HOLESSDR 2008UALA05444Floorbeam · corrodedFLOORBEAM 175 IS CORRODED (MARKED). MAJOR REPAIR ACCOMPLISHED. REMOVED FLOORBEAM 175. TRANSFERRED CABLE ATTACH BRACKETS AND STARTED ASSEMBLY WITH BEAM 210. BEAM 175 AND 210 ARE TOGETHER AND NEED FWD END OF BEAM PUT INTO AC AND DRILL FWD ATTACH HOLES. PICSDR SWAA084632Floorbeam · corrodedDURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED AT BS 767, LBL 12.50. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA084631Floorbeam · corrodedDURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED AT BS 500, STR 26R. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA084629Floorbeam · corrodedDURING SCHEDULED SPV CHECK, FOUND FLOORBEAM CORRODED AT BS 947, LBL 6. REPAIRED FLOORBEAM PER SRM.SDR F3LA200800584Floorbeam · corrodedREFERENCE NON ROUTINE CO50117. DURING C3 C-CHECK, INSP NOTED LT FLOORBEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM FRAME 66 TO FRAME 68 (L2 DOOR AREA). MX R&R THE FLOORBEAM IAW THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR 19-53R-30587. UPON CSDR KCSA081422Floorbeam · dentedFORWARD BILGE HAS A DENT IN FLOORBEAM WEB AT STA 720, LBL 46, WL 108. (S)SDR USAA920081843Floorbeam · corrodedSAL - C19 - MAJOR REPAIR, CORROSION ON FLOORBEAM UPPER CHORD AT BS 986.5, BETWEEN LBL 44 TO RBL 42. REPAIRED FLOORBEAM UPPER CHORD AT BS 986.5, BETWEEN LBL 44 TO RBL 42 IAW B737 SRM 53-00-51.SDR USAA920081677Floorbeam · corrodedCORROSION ON FLOORBEAM BETWEEN BS 986.5 TO 1006, RBL 15. REPAIRED FLOORBEAM IAW SRM 53-00-51. (K)SDR USAA920081657Floorbeam · corrodedSAL C19 MAJOR REPAIR NR 6097659 GALVANIC CORROSION ON FLOOR BEAM UPPER CORD AT BS967, RBL 28. REPAIRED FLOOR BEAM UPPER CORD AT BS967, RBL28 IAW B737 SRM 53-00-51.SDR TRAX200801083Strip · brokenJOB 8752721 OPERATION 251 LBL 27 FLOOR BEAM FILLER STRIP BETWEEN FS 574 TO FS 621 IS BROKEN IN SEVERAL PLACES. REMOVED BROKEN LBL 27 FLOOR BEAM FILLER STRIP BETWEEN FS 576 TO 621 AND INSTALLED NEW SERVICEABLE FILLER STRIP IAW CRJ 200 SRM 51-41-04.SDR TRAX200801082Floorbeam · corrodedJOB 8752721 OPERATION 239. FLOORBEAM OTBD FLANGE AT FS 574 TO FS 621, LBL 27 HAS CORRODED NUTPLATE HOLES. REMOVED FILLER STRIP TO ACCESS BEAM CAP REMOVAL IAW CRJ 200 SRM 51-41-02. REMOVED HARDWARE. 7 BOLTS FROM LT ELEV PULLEY BRACKET JUST FWD OF FS 621 BULSDR F3LA200800583Floorbeam · corrodedREFERENCE NON ROUTINE CO50040. DURING C3 C-CHECK, INSP NOTED FLOOR BEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM RT HAND FRAME 67 TO FRAME 68. MAINTENANCE INSTALLED NEW FLOOR BEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11 AND ENGINEESDR F3LA200800582Floorbeam · corrodedREFERENCE NON ROUTINE CO50039. DURING C3 C-CHECK, INSP NOTED FLOOR BEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM RT HAND FRAME 66 TO FRAME 67. SUPPLEMENTAL INFORMATION WILL BE PROVIDED AS SOON AS CORRECTIVE ACTION INFORMATION BECOMES AVAILABLE. MX SDR F3L2008F00004Floorbeam · corrodedREFERENCE NON ROUTINE C050039. DURING C3 C-CHECK, INSP NOTED FLOOR BEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM RT HAND FRAME 66 TO FRAME 67. SUPPLEMENTAL INFORMATION WILL BE PROVIDED AS SOON AS CORRECTIVE ACTION INFORMATION BECOMES AVAILABLE. (OSDR 08FDEA03559Floorbeam · corrodedMAIN CARGO FLOORBEAM HAS CORROSION AT BS 345, LBL 21 TO 34. MINOR CORROSION REMOVED, TREATED AND IS WITHIN ALLOWABLE DAMAGE LIMIT IAW SRM 53-00-51 REV. 93, FIG. 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR 08FDEA03558Floorbeam · corrodedMAIN CARGO FLOORBEAM AT BS 377, LBL 22 HAS CORROSION. MINOR CORROSION ON FLOORBEAM REMOVED, TREATED, AND IS WITHIN ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-51 REV 93, FIG 101. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR SWIA200820429Floorbeam · crackedC-CHECK, FS 280 COCKPIT FLOOR SUPPORT ANGLE CRACKED. REPAIRED PER REO.