JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2006UALA00065Floorbeam · damagedSTA 294.5 RBL 37 WL 208 CABIN FLOORBEAM UPPER CAP FLANGE HAVE OVER 10 PERCENT CORROSION. *S/D* FABRICATED AND INSTALLED ANGLE REPAIR REF SRM 53-10-95.SDR 06FDEA0181Floorbeam · corrodedCORROSION STA 312 LBL 30 WL 208 CORROSION ON FLOORBEAM UPPER CHORD. *S/D* REPAIRED FLOORBEAM AT STA 312, LBL 30, WL 208 PER SRM 53-10-8, 53-10-1.SDR 06FDEA0180Floorbeam · corrodedCORROSION STA 328 LBL 30 AND LBL 40 WL 208 CORROSION ON FLOORBEAM UPPER CHORD. *S/D* REPAIRED FLOORBEAM AT BS 328, LBL 30 AND 40, WL 208 PER SRM 53-10-8, 53-10-1, 51-30-02.SDR USAA060020Floorbeam · corrodedFOUND FLOORBEAM CORRODED STA 1640 BETWEEN LBL 60 TO RBL 60 ON FLOORBEAM. REPAIRED PER EA NR 97242, DEFECT SIZE: 2" BY 2" BY .060", 12" BY 2" BY .060", 12" BY 2" BY .050", 2" BY 2" BY .040".SDR USAA060027Floorbeam · corrodedFOUND FLOORBEAM Y1160 RT, BETWEEN FS 66-68. REMOVED AND REPLACED TWO FLOORBEAM SECTIONS PER 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1" BY 1".SDR USAA060026Floorbeam · corrodedFOUND FLOORBEAM CORRODED Y495 FS 12 - 16. REMOVED AND REPLACED BEAM, REPLACED WITH DEFECTIVE PART; CORROSION LEVEL 1; TASK JA-220-53500, DEFECT SIZE: 1/2" BY 1/2" AREA.SDR USAA060030Floorbeam · corrodedFOUND FLOORBEAM CORRODED Y1160 BETWEEN FS 66 AND 68. REMOVED AND REPLACED WITH SAME PARTS PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1" BY 2" BY .046" AND 1" BY 1" BY .028".SDR USAA060029Floorbeam · corrodedFOUND FLOORBEAM CORRODED, SEAT TRACK BEAM Y765, FS 20. REMOVED AND REPLACED FLOORBEAM PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-220-53500 DEFECT SIZE: 1" SQ.SDR USAA0620Floorbeam · corrodedSTA 1640 BETWEEN LBL 60 TO RBL 60 ON FLOORBEAM CORRODED. REPAIRED PER EA 97242, DEFECT SIZE: 2" X 2" X .060", 12" X 2" X .060", 12" X 2" X .050", 2" X 2" X .040".SDR USAA0627Floorbeam · corrodedFLOORBEAM Y1160 RT, BETWEEN FR 66-68 CORRODED. REMOVED & REPLACED TWO FLOORBEAM SECTIONS PER 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1 X 1 INCH.SDR USAA0626Floorbeam · corrodedFLOORBEAM Y495 FR 12 - 16 CORRODED. REMOVED AND REPLACED BEAM, REPLACED WITH DEFECTIVE PART; CORROSION LEVEL 1; TASK JA-220-53500, DEFECT SIZE: .5 X .5 INCH AREA.SDR USAA0630Floorbeam · corrodedFLOORBEAM Y1160 BETWEEN FR 66 & 68 CORRODED. REMOVED & REPLACED WITH SAME PARTS PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1" X 2" X .046" & 1" X 1" X .028".SDR IXXA06SMN031SFloorbeam · corrodedDURING C CHECK, MAIN CARGO COMPT FLOORBEAM UPPER FLANGE CORRODED AT STA 1548.000 BL 0. PERFORMED MAJOR REPAIR IAW DC8 SRM 51-2-1 FIG 1 (SHEET 8), TR NR 51-130 DATED 01-26-04. REMOVED CORROSION IAW DC8 SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW DC8 SRM 53-SDR UPS06246101Floorbeam · corrodedINSPECTION TYPE:C ON REMOVAL OF FLOORBOARD AT BS 360 EVIDENCE OF CORROSION FOUND. UPPER CHORD OF FLOORBEAM REMOVED BETWEEN RBL 12 AND LBL 67 AT BS 360. REPAIR CARRIED OUT IAW SRM NR 53-10-5.SDR AWXA200600183Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y919, FROM FS 66 TO FS 66+6". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 65 TO FS 67 AND AT SDR AWXA200600182Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y1165 AND FS 66. MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 64 TO FS 66 AND AT Y1292 IAW AIRSDR AWXA200600180Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y-1292 AND AT FS 67+7". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 66 TO FS 68 AND AT Y-1292SDR AWXA200600179Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y-1292 AND AT FS 65+21". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 64 TO FS 66 AND AT Y-129SDR AWXA200600178Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y765 AND AT FS 64+10". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 66 TO FS 66 AND AT Y765 IASDR AWXA200600177Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y-765 AND AT FS 67+16". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 66 TO FS 70 AND AT Y-765 SDR AWXA200600174Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y1165 AND AT FR 67+16". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 66 TO FS 68 AND AT Y1165 SDR AWXA200600173Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED LEVEL 2 CORROSION ON FLOORBEAM LOCATED AT Y-1292 AND AT FS 68+8". MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 68 TO FS 69 AND ASDR AWXA200600172Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C7 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y 1582 AND BETWEEN FS 65 TO FS 66. MAINTENANCE FOUND RE-WORK TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-1A FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM FROM FS 65 TO FS 66 ANSDR UPS06246027Floorbeam · corrodedC-CHECK SI REF. NRC 100662 FLOORBEAM TOP CHORD CORROSION WAS REMOVED BS 344 AND FOUND OUTSIDE LIMITS OF SRM . REPLACE TOP CHORD SECTION RBL 80 - LBL 66 . REF SRM 53-10-8 FIG 7 FLOORBEAM TOP CHORD REMOVED IAW SRM 51-30-02. NEW TOP CHORD FABRICATED IAW SRM SDR AWXA200600221Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C4 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y-1292, FROM FS 66 TO FS 68. MAINTENANCE FOUND THE CORROSION TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-14 FIG 102. FLOORBEAM WAS REMOVED AND NEW BEAM WAS INSTALLED FROM FS 6SDR AWXA200600220Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C4 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y-1292, FROM FS 68 TO FS 69. MAINTENANCE FOUND THE CORROSION TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-14 FIG 102. FLOORBEAM WAS REMOVED AND NEW BEAM WAS INSTALLED FROM FS 6SDR AWXA200600219Floorbeam · corrodedSAL - MAJOR REPAIR - DURING C4 CHECK DISCOVERED CORROSION ON FLOORBEAM LOCATED AT Y-464, FROM FS 65 TO FS 67. MAINTENANCE FOUND THE CORROSION TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-00-14 FIG 102. FLOORBEAM WAS REMOVED AND NEW BEAM WAS INSTALLED FROM FS 64SDR RAIA00601029Floorbeam · corrodedDURING 10,000 FH INSPECTION CORROSION WAS FOUND AT THE NUT PLATES OF THE FORWARD DIGITAL AT FRAME 14. MAINTENANCE REMOVED AND REPLACED THE REPAIR ON THE FORWARD DIGITAL AT FRAME 14.SDR ASAA0640022Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER STRUCTUREAT BS 312, WL 208, LBL 11. REMOVED AND REPLACED STRUCTURE IAW SRM AND EA. (K)SDR ASAA0640017Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CHORD. REPAIRED FLOORBEAM IAW SRM. (K)SDR AWXA200600389Floorbeam · crackedMCN - DURING C24 CHECK DISCOVERED FLOORBEAM CRACKED, .25 INCHES, AT BS 663 AND BL 24L. MAINTENANCE STOP DRILLED CRACK IAW AMERICA WEST AIRLINES (AWA) ENGINEERING REPAIR (ER) NR 03-5702-06039-HF1. FABRICATED REPAIR CHANNEL IAW AWA ER 03-5702-06039-HF1. INSTASDR 2006UALA00053Floorbeam · corrodedAFT CABIN STA 947 FROM LBL 25 TO RBL 21 FLOORBEAM UPPER CHORD CORRODED AROUND 5 EA FASTENER HOLES. BLENDED CORRODED AREAS & FOUND BLEND OUT OF LIMITS. FABRICATED & INSTALLED NESTED ANGLE REPAIRS TO UPPER CHORD OF FLOOR BEAM REF MM 53-10-95.SDR USAA060016Floorbeam · corrodedFOUND SHEET METAL CORRODED ON FLOORBEAM STA 328 RBL 21. INSTALLED DOUBLER IAW SRM 53-00-51 FIG 201, DEFECT SIZE: SHEETMETAL ITEM 1030M EVIDENCE OF CORROSION ON FLOORBEAM 1" BY 2", STA 328 RBL 21.SDR USAA060011Floorbeam · corrodedFOUND FLOORBEAM CORRODED BS 986.5 CABIN FLOORBEAM LBL 18, 21,24,30. REPLACED "T" CAP IAW TR 53-60-01A, DEFECT SIZE: SEVERAL 1" BY 1" CORRODED AREAS.SDR USAA0616Floorbeam · corrodedCORROSION ON FLOORBEAM STA 328 RBL 21 CORROSION. INSTALLED DOUBLER IAW SRM 53-00-51 FIG 201, DEFECT SIZE: SHEETMETAL ITEM 1030M EVIDENCE OF CORROSION ON FLOORBEAM 1 X 2 INCH, STA 328 RBL 21.SDR USAA0611Floorbeam · corrodedBS 986.5 CABIN FLOORBEAM LBL 18, 21, 24, 30 CORROSION. REPLACED T-CAP IAW TR 53-60-01A, DEFECT SIZE: SEVERAL 1 X 1 INCH CORRODED AREAS.SDR USAA0516Floorbeam · corrodedCORROSION ON FLOORBEAM STA 328 RBL 21. INSTALLED DOUBLER IAW SRM 53-00-51 FIG 201, DEFECT SIZE: SHEETMETAL ITEM 1030M EVIDENCE OF CORROSION ON FLOORBEAM 1 X 2 INCH, STA 328 RBL 21.SDR USAA0511Floorbeam · corrodedBS 986.5 CABIN FLOORBEAM LBL 18, 21, 24, 30 CORRODED. REPLACED T-CAP IAW TR 53-60-01A, DEFECT SIZE: SEVERAL 1INCH X 1INCH CORRODED AREAS.SDR C2XA06TY005Floorbeam · corrodedGALLEY AREA RT OMEGA BEAM CORRODED. BLENDED OUT CORROSION, APPLIED HYSOL, FABRICATED REPAIR DOUBLER, DRILLED COUNTERSANK, ALODINED, PRIMED. INSTALLED PAINT. ALL WORK C/W IAW EMB135/145 SRM 51-10-03, 51-20-03, 51-40-06, 51-40-02 AND 53-21-10 AND CPM 51-21-04SDR A6WA200640035Floorbeam · crackedFLOORBEAM WEB AFT ANGLE AT FS 559.00 + 48, LBL9, IS CRACKED APPROX .2500 INCH LONG, MAINTENANCE CUTOFF CRACKED FLANGE AND INSTALLED REPAIR ANGLE IAW EO. (K)SDR 06FDEA0106Floorbeam · corrodedAFT CARGO, FLOORBEAM LOWER FLANGE CORRODED AT BS 1070, LBL 28, WL 201. REPAIRED PER SRM 53-10-8.SDR SWAA060102Floorbeam · corrodedDURING SCHEDULED 1/4D CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 727A, RBL 3. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA060100Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 986.5, BETWEEN LBL 35 TO RBL 43. REPAIRED FLOOR BEAM PER BFG ER.SDR ASOA06071Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS FOUND ON THE TRANSVERSE FLOOR BEAM END, AT FS 34B, RBL 44. MAINTENANCE REPAIRED THE TRANSVERSE FLOOR BEAM END, AT FS 346, RBL44, IAW REO. (K)SDR C2XA06SH003Floorbeam · corrodedSHV - DURING C CHECK, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 17-25. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SWAA060081Floorbeam · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FLOORBEAM CRACKED AT BS 947.5, LBL 53.5. REPAIRED FLOORBEAM IAW BFG ER.SDR SWIA200616538Floorbeam · crackedFUSELAGE, LOWER TRANSVERSE BEAM IS CRACKED, FS 280.00, LBL 11.0. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED REF REO 601R-53-11-171 REV C.SDR ASOA05018SCap · corrodedDURING A C-CHECK, CORROSION WAS FOUND ON THE TRANSVERSE FLOORBEAM CAP AT FS 559.112, RBL 27-45. AFTER MAINTENANCE ALODINED, PRIMED, AND BLENDED THE TRANSVERSE FLOORBEAM CAP AT FS 559, RBL 27-45, IT WAS FOUND TO BE WITHIN ACCEPTABLE LIMITS. (K)SDR MJYA0601019Floorbeam · crackedFUSELAGE AFT CARGO COMPARTMENT DOOR LOWER BEAM REPAIRED DUE TO CRACK.SDR MJYA0601041Floorbeam · corrodedREPAIRED MAIN CARGO CABIN FLOORBEAM UPPER CHORD DUE TO CORROSION.
Back to JASC 5315