What was found
FOUND FLOORBEAM CORRODED Y1160 BETWEEN FS 66 AND 68. REMOVED AND REPLACED WITH SAME PARTS PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1" BY 2" BY .046" AND 1" BY 1" BY .028".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM CORRODED Y1160 BETWEEN FS 66 AND 68. REMOVED AND REPLACED WITH SAME PARTS PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1" BY 2" BY .046" AND 1" BY 1" BY .028".