JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA200501374Floorbeam · corrodedGYR - DURING C10 CHECK, DISCOVERED FLOORBEAM AT BS 345, WL 208.10 AND BL 60R CORRODED. MAINTENANCE REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT AND REMOVED FLOORBEAM AT STA 345, WL 208.10 AND BL 60R IAW BOEING 757-200 SRM 53-00-51. FABRICATED CHSDR 05FDEA03490Floorbeam · corrodedBS 480 FLOORBEAM UPPER CHORD CORRODED AT RBL 48, WL 208. [OPEN]SDR 05FDEA03484Floorbeam · corrodedMDCC - FLOORBEAM BS 344 LBL-14-40 HAS SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-10-6, BEFORE REMOVED MATERIAL 0.110 AFTER 0.104 WITHIN LIMITS IAW SRM 51-10-1. TREATED AND PRIMED IAW SRM 51-10-2.SDR 05FDEA03483Floorbeam · corrodedMDCC - FLOORBEAM CORRODED BS 312 LBL-42. REMOVED CORROSION IAW SRM 53-10- 1 MATERIAL LOSS OF 0.007 ORIGINAL THICKNESS 0.080 , FOUND TO BE WITHIN LIMITS PER SRM 53-10-1 FIG 5. TREATED AND PRIMED AREA IAW SRM 51-10-2.SDR 05FDEA03482Floorbeam · corrodedMDCC - FLOORBEAM BS 560 LBL21 HAS CORROSION. REMOVED CORROSION IAW SRM 53-10-1MAT LOSS OF .001 ORIGINAL THICKNESS OF 0.230 FOUND TO BE WITHIN LIMITS IAW SRM 51-10-6 TREATED AND PRIMED IAW SRM 51-10-2.SDR ASAA0540558Floorbeam · corrodedPAE - FOUND CORROSION ON FLOORBEAM. REMOVED DAMAGED UPPER CHORD, FABRICATED NEW UPPER CHORD, REPAIR PARTS AND INSTALLED IAW 737-400 SRM 53-00-51. (M)SDR USAA051232Floorbeam · corrodedFOUND CORROSION STA 397 RBL 51, WL 208.10; CORROSION LEVEL 1; TASK C53-222-03. FABRICATED AND INSTALLED FLOOR SUPPORT PER SRM 53-00-51, 51-40-02, DWG 141N5170, DEFECT SIZE: 4" BY 3" BY .030".SDR USAA051237Floorbeam · corrodedSTA 1640 RBL 56 AND LBL 56 MAIN CABIN FLOORBEAM CORRODED. REPLACED NEW UPPER CHORD AND SPLICE PER TYP REP 53-15-01 AND SRM 51-40-02, DEFECT SIZE: 10" L BY 1.5" W BY .97"D.SDR ABXA060034Floorbeam · crackedMAIN CABIN, STA 900, RIGHT BUTT LINE 54, FLOORBEAM CRACKED ON AFT SIDE UPPER CAP, FROM OUTBOARD END OF BEAM TOWARD INBOARD THROUGH TWO FASTENER HOLES. REPAIRED AREA IAW REA D853-52925 BY TRIMMING OUT CRACKED AREA AND INSTALLING A FILLER.SDR ABXA060026Floorbeam · corrodedMAIN CABIN, BS 120, RIGHT BUTT LINE 50, FLOORBEAM HAD EXCESSIVE MATERIAL LOSS. REMOVED DAMAGED AREA AND REPLACED WITH ANGLE DOUBLER AND FILLER ON FLOORBEAM BS 120, RIGHT BUTT LINE 50 IAW DC8 SRM 51-1-8, 53-2-0, 51-3-0, 53-7-3, 53-0, 51-2-0, 51-1-8, 51-3-1, 51SDR ABXA050366Floorbeam · corrodedFOUND MAIN CABIN, STA 70, RIGHT BUTT LINE 43-51, LOWER SIDE OF FLOORBEAM CORRODED OUT OF LIMITS. FOUND LOWER SIDE OF FLOORBEAM CORRODED OUT OF LIMITS AT STA 70, RIGHT BUTT LINE 43-51. FABRICATED FILLER AND DOUBLER AND INSTALLED. ALL WORK IAW DC8 SRM 51-1-8,SDR ABXA050352Floorbeam · corrodedFOUND MAIN CABIN, STA 920, RIGHT BUTT LINE 31, FLOORBEAM CORRODED AT NUTPLATES. REMOVED CORROSION STA 920, RIGHT BUTT LINE 31. MATERIAL LOSS OUT OF LIMITES. FABRICATED REPAIR ANGLES AND INSTALLED IAW DWG K04881 OUT OF 7075 "0", PO NR 1108502 0.063", HEAT TRSDR ABXA050351Floorbeam · corrodedFOUND MAIN CABIN, STA 680, RIGHT BUTT LINE 26, LOWER SIDE OF FLOORBEAM CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8, ORIGINAL MATERIAL THICKNESS 0.178", REMAINING THICKNESS 0.107" AND OUT OF LIMITS IAW DC8 SRM 53-2-0. VERIFIED REPAIR AINGLE AS AND10134-1407SDR 05FDEA03458Floorbeam · corrodedFLOORBEAM HAS SEVERAL CORRODED FASTENERS NUT PLATES AND SURFACE UNDER NUT PLATES. BS 1166 FROM RBL 27 TO OB END. REMOVED CORRODED NUT PLATES IAW SRM 51-31-2 REMOVED CORROSION IAW SRM51-10-6,CHECKED LIMITS . ORIGINAL MATERIAL: .125 AFTER REWORK: .118 WITH ISDR 05FDEA03457Floorbeam · corrodedMAIN CARGO COMP FLOORBEAM CORRODED, STA 344 FROM LBL36 TO RBL18. REMOVED, FABRICATED, ALODINED, PRIMED, PAINTED AND INSTALLED FLOORBEAM REPAIR AT STA 344 FROM LBL36 TO RBL18 ALL IAW SRM 51-30-2, 51-10-2, 51-20-031-7 AND SRZ SR27-53-007.**S/D COMING**SDR 05FDEA03456Floorbeam · corrodedFLOORBEAM 380 HAS CORROSION AT RBL 53 TO RBL 56. REMOVED, FABRICATED, HEAT TREATED, CAD PLATED, ALODINED, PRIMED, PAINTED AND INSTALLED FLOORBEAM REPAIR AT STA 380 FROM RBL 53 TO RBL 56 ALL IAW FX SRZ SR27-53-034E REPAIR 5, BAC5619, AMS-QQ-P-416, B727 SRM'S 5SDR SWAA053285Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT BS 360, BETWEEN RBL 51 TO RBL 61. REPAIRED FLOORBEAM PER SRM.SDR SWAA053284Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM UPPER CAP CORRODED AT BS 986. REMOVED AND REPLACED FLOORBEAM UPPER CAP PER SWA EA.SDR ASOA05885Floorbeam · corrodedDURING HANGAR MAINTENANCE IN MCN, THE FLOORBOARD SUPPORT BEAM, JUST INBOARD OF THE AIRSTAIR DOOR SILL, WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE WILL REMOVE AND REPLACE THE FLOORBOARD SUPPORT BEAM, INBOARD OF THE AIRSTAIR DOOR SILL. OPERATIONAL CHESDR USAA051219Floorbeam · corrodedLEFT AFT ENTRY SILL BEAM (FR 66 & Y1492) HAS CORROSION. DOUBLERS INSTALLED PER SRM 53-41-14, DEFECT SIZE: 1.5 X 1 INCH AREA.SDR USAA051217Floorbeam · corrodedAT SPLICE PLATE Y1292 FR 66 TO 68 FLOORBEAM; CORROSION LEVEL 1; TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 51-72-11, DEFECT SIZE: .030 TO .060 INCH DEEP.SDR USAA051213Floorbeam · corrodedY505, FRAME C-12 TO C-16; CORROSION LEVEL 1; TASK JA-220-53500. REMOVED & REPLACED FLOORBEAM PER SRM 53-11-14, DEFECT SIZE: 1 X 4 INCH.SDR USAA051215Floorbeam · corrodedY1292 BEAM AT SPLICE AT FR 66; CORROSION LEVEL 2; TASK JA-260-53500. REMOVED & REPLACED PER SRM 51-72-11, IPC 53-41-04, DEFECT SIZE: 2 X 4 X .030 INCH DEEP.SDR USAA051214Floorbeam · corrodedY1162 BEAM AT SPLICE FR 68 & 69; CORROSION LEVEL 2; TASK JA-260-53500. REMOVED & REPLACED PER SRM 51-72-11 & IPC 53-41-04, DEFECT SIZE: 3 X 3 X .030 INCH DEEP.SDR USAA051223Floorbeam · corrodedFOUND FLOORBEAM WEB CORRODED STA 331 RBL 1, FLOORBEAM WEB; LEVEL 1;TASK C53-222-03. REMOVED AND REPLACED FLOORBEAM; LEVEL 1; TASK C53-222-03, DEFECT SIZE: 1.9"L BY 1.6"W BY .080"D.SDR ASAA0540556Floorbeam · corrodedPAE - FOUND CORROSION ON FLOORBEAM. REMOVED CORRODED UPPER CHORD, FABRICATED AND INSTALLED NEW CHORD, REPAIR SPLICES, AND ANGLES IAW 737-400 SRM 53-10-51. (M)SDR SWIA200515748Floorbeam · crackedCARGO COMPT; FLOORBEAM ANGLE IS CRACKED; FS 621.0 - LBL 40.0. ITEM FOUND AT C-CHECK INSPECTION.SDR SWIA200515743Floorbeam · crackedFUSELAGE; UPPER TRANSVERSE BEAM ANGLE CRACKED; FS 280.00 LBL 12.0. ITEM FOUND AT C-CHECK INSPECTION.SDR 05FDEA03448Floorbeam · crackedN00474 E&E BAY FLOORBEAM WEB BS 295 LBL 30 WL 200 CRACK EXTENDING UP FROM STOP DRILL. STOP DRILLED CRACK AND REPAIRED WEB AT CRACK IN E&E BAY FLOORBEAM WEB BS 295 LBL 30 WL 200 IAW SRM 51-10-1 AND SRM 51-40-2SDR 05FDEA03445Floorbeam · crackedAFT INTERMEDIATE FUSELAGE, FLOORBEAM LOWER CAP FOUND CRACK AT STA 1801 LBL 8 TO RBL 8. REPAIRED AS PER EA 1-5310-87655. CLASSIFIED MAJOR REPAIR PER GMM 6-2-100.SDR SWAA053243Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND COCKPIT FLOOR Z-CHORD CORRODED AT BS 270, BETWEEN LBL 11 TO RBL 11. REPAIRED Z-CHORD PER SRM.SDR LR7A05137Floorbeam · corrodedDURING C-6 CHECK PER HC5312, FOUND CORROSION DAMAGE IN LOWER FORWARD UNDERDECK FLOOR SUPPORT CHANNEL FS 210, BL 0 WL146. REPLACED FLOOR SUPPORT CHANNEL IAW SRM SMP 583 51-70, NR 0307.SDR LR7A05136Floorbeam · corrodedDURING C-6 CHECK PER HC5312, FOUND CORROSION DAMAGE LOWER FORWARD UNDERDECK FLOOR SUPPORT ANGLE, FS 200, RBL9 WL146. REPLACED FLOOR SUPPORT ANGLE IAW SRM SMP 583 51-70 AND ED05-025-02, NR 0307.SDR LR7A05135Floorbeam · corrodedDURING C-6 CHECK PER HC5312, FOUND CORROSION DAMAGE LOWER FORWARD UNDERDECK FLOOR SUPPORT ANGLE, FS 200, LBL9 WL146. REPLACED FLOOR SUPPORT ANGLE IAW SRM SMP 583 51-70 AND ED05-025-02, NR 0307.SDR CALA0500366Floorbeam · corrodedSEVERAL CLIP HOLES CORRODED AT BS 986.5, FROM RBL 51- LBL51. REPAIRED PER ECRA 5321-01300.SDR ASAA0540552Floorbeam · damagedPAE - MECHANICAL DAMAGE TO FLOORBEAM. REMOVED AND REPLACED FLOORBEAM UPPER CHORD AT BS 294.5 IAW 737-400 SRM 53-10-81. (M)SDR ASAA0540551Floorbeam · corrodedPAE - FOUND CORROSION ON FLOORBEAM. REMOVED AND REPLACED FLOORBEAM UPPER CHORD AT BS 312 WL 208, LBL 65-23, IAW 737-400 SRM 53-10-51. (M)SDR CALA0500364Floorbeam · corrodedRT GALLEY FLOORBEAM ANGLE CORRODED AFT OF STA 986.5, RBL 50. REPLACED FLOOR SUPPORT ANGLE PER SRM 51-40-02.SDR SWAA053195Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 328, RBL 21, RBL 28 & RBL 36. REPAIRED FLOORBEAM PER SRM.SDR SWAA053194Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FUSELAGE FLOORBEAM T-CHORD CORRODED AT BS 312, BETWEEN LBL 54 TO RBL 54. REMOVED AND REPLACED T-CHORD PER SRM.SDR SWAA053205Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 986, BETWEEN LBL 45 TO RBL 45. REPAIRED FLOORBEAM PER BFG ER.SDR ABXA050335Floorbeam · corrodedMAIN DECK AFT ACCESSORY COMPARTMENT, STA 1660, LEFT BUTT LINE 44, LONGERON 22 LEFT, FLOORBEAM HAD CORROSION. CLEANED UP SURFACE CORROSION WITH NEGLIGIBLE MATERIAL LOSS EXCEPT FOR AROUND ONE FASTENER HOLE. REPAIRED CORROSION DAMAGE IAW DC8 SRM 51-1-8, PG 20, SDR EIA2005196Floorbeam · damagedU/D BS 520 FLOORBEAM UPPER CHORD FWD FLANGE FLOOR PANEL ATT HOLE FOUND SHORT OF E/D AT LBL 73", 77", 80", 84", & 91". REPAIRED PER SB747-53A2452 FIG 9.SDR EIA2005193Floorbeam · crackedU/D BS 600 FLOORBEAM UPPER CHORD HORIZONTAL AFT FLANGE RBL 25 FLOOR PANEL ATT HOLE CRACKED RUNNING FWD AND AFT APPROX .125" LONG. REPAIRED PER SB 747-53A2452 FIG 13.SDR EIA2005203Floorbeam · damagedBS 380 FLOORBEAM UPPER CHORD FWD FLANGE FLOOR PANEL AT HOLE FOUND SHORT OF E/D AT LBL 36", 30", 21", 16", RBL 9.5', 16.5", 20", AND 25". REPAIRED DEFECTIVE FLOORBEAMS UPPER CHORD PER SB 747-53A2452 FIG 7.SDR EIA2005200Floorbeam · damagedBS 380 UPPER DECK FLOORBEAM UPPER CHORD FWD FLANGE FLOOR PANEL ATT HOLE FOUND SHORT OF E/D AT LBL 44" AND 56". REPAIRED FLOORBEAM UPPER CHORD LBL 40 THRU 49, AND 51 THRU 61, PER SB747-53A2431 FIG 8.SDR 2005UALA01139Floorbeam · crackedBS 700 CABIN FLOORBEAM UPPER CAP HAS DAMAGE. BS 700 LBL 25 FLOORBEAM UPPER CHORD SPLICE REPAIR ACP'D PER MM 53 00 98 825 DUE TO CRACK IN RADIUS.SDR CALA050361Floorbeam · corrodedAFT CABIN FLOORBEAM CHORD HEAVILY CORRODED AT STA 986.5. REPAIRED CHORD PER ECRA 5311-01241.SDR DL73S050615Floorbeam · crackedTHE RBL 24 LONGITUDINAL OVERWING FLOORBEAM HAS BEEN PREVIOUSLY MODIFIED PER 3-056673-3AD. THE C-CHANNEL INSTALLED PER THIS EO DOES NOT MEET EXISTING AD REQUIREMENTS. CRACKS WERE FOUND IN THE UPPER CHORD, BEAM AFT WEB, AND WEB DOUBLERS. THE C-CHANNEL WAS REPSDR DL73S050614Floorbeam · crackedTHE LBL 24 LONGITUDINAL OVERWING FLOORBEAM WAS MODIFIED USING A PREVIOUSLY ACCEPTALBE C-CHANNEL THAT IS NOT ACCEPTABLE PER AD 2001-17-18. CRACKS WERE FOUND IN THE BEAM AFT WEB AND WEB DOUBLER. C-CHANNEL WAS REPLACED. WEB REPAIR DOUBLER WAS INSTALLED, AND CR
Back to JASC 5315