JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200300062Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED FLOORBEAM CAP AT STA 1006 CORRODED IN VARIOUS AREAS FROM CENTERLINE EXTENDING TO LEFT SIDE. REPAIRED PER SRM 53-10-9, FIG 7.SDR F3LA200300061Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON CARGO FLOORBEAM AT NUT PLATE ON UNDERSIDE OF UPPER FLANGE, STA 794, LBL 8. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-01. FABRICATED AND INSTALLED REPAIR PER SRM 53-10-05, SRM 53-10-05, FIG 11, SHEET SDR AWXA200300146Seat Track · misalignedLCQ - MAJOR REPAIR - DURING C-18 CHECK THE L/H OUTBOARD SEAT TRACK SPLICE WAS FOUND INTERFERING WITH THE SEAT ATTACH POINT BS 847. MAINTENANCE REMOVED SEAT TRACK FROM BS 807 TO BS 847, LBL 45; FABRICATED A NEW REPLACEMENT SEAT TRACK; INSTALLED REPAIR PART IAW SDR AUS20030291Floorbeam · corroded(AUS) AFT CARGO FLOORBEAM ANGLE CONTAINED LEVEL 2 CORROSION IN AREALOCATED AT BS 1166 ABOVE STRINGER 27L BETWEEN BL16L AND BL23L. FOUND DURING INSPECTION IAW CPCP C53-113-01.SDR UPS03840232Floorbeam · corrodedINSPECTION TYPE: C1, FLOORBEAM UPPER FLANGE IS CORRODED BEYOND LIMITS AT STA 1580 AT LBL 5. CUT OUT DAMAGED AREA, NDT VERIFIED NO CRACKS AT CUTOUT. FABRICATED AND INSTALLED ANGLE DOUBLER AND FILLER IAW SRM 53-2-0 FIG 1G.SDR 2003UALA00177Stiffener · crackedSTA 246 FLOOR BEAM HAD CRACKED STIFFENER AT LBL 26.26 MAJOR REPAIR ACCOMPLISHED. REPLACED STIFFENER.SDR 03FDEA00120Floorbeam · corrodedCORROSION ON FLOORBEAM BS 1070, LBL 18, WL 200. ** SD ** COMINGSDR BJNA03027Floorbeam · corrodedDURING A SCHEDULED MAINTENANCE VISIT, LEVEL 2 CORROSION WAS DISCOVERED ON A FLOORBEAM LOCATED IN THE FORWARD CARGO COMPARTMENT AT FS 500 PLUS 40 INCH BL 12R, AREA OF CORROSION IS APPROXIMATELY 3 INCHES BY 1 INCH ON THE FRAME LOWER FORWARD FLANGE. REMOVED THE SDR 2003UALA00172Floorbeam · crackedSTATION 246 FLOORBEAM WAS CRACKED AT RBL 38.5 AND LBL 38.5. MAJOR REPAIR ACCOMPLISHED. BOTH CRACKS WERE REPAIRED AT 'C' CHECK.SDR SWAA030329Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT RBL 8, BS 845 AND BS 825. REPAIRED FLOORBEAM PER SWA RA.SDR 03FDEA00118Floorbeam · corrodedCORROSION AROUND LOWER FLOORBEAM ANGLE NUT PLATE HOLES. BS 1070, LBL 41, RBL 51, WL 201. REPLACED BS 1070 FLOORBEAM LOWER ANGLE IAW EA 7-5310-68182.SDR SIMA200304808Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, A PREVIOUS REPAIR ON THE FORWARD DIGITAL WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED EXISTING SHIM AND DOUBLERS. REMOVED SECTION OF THE FORWARD DIGITAL. FABRICATED TWO DOUBLERS AND SHIMS. PREPARED NEW SECTION STRAP.SDR QXEA0300267Floorbeam · chafedPDX - AFT BAG PIT X783 Y25L ANGLE HAS CHAFE DAMAGE FROM A FLOORBOARD. REPAIRED IAW RD 8/4-53-417, STEPS 4/6 AND DHC-8 Q400 SRM 51-14-00-350-804.SDR SWAA030318Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAMS CORRODED AT BS 770 AT LBL 13, BS 860 AT RBL 8, BS 860 AT LBL 3, BS 847 AT LBL 6 AND BS 813 AT LBL 3. REPAIRED FLOORBEAMS PER SWA ER.SDR AUS20030494Floorbeam · corroded(AUS) FLOORBEAMS CONTAINED LEVEL 2 CORROSION BETWEEN FR 64 AND FR 69.THE FOLLOWING FLOORBEAMS WERE AFFECTED:- 1) FLOORBEAM (PN D5347217220390) FROM FR66 TO FR68 RT IN TWO AREAS AT Y1292.0 RT 2) FLOORBEAM (PN D5347218920200) ON AFT OF FR69 AT Y1162.5 RT.SDR AWXA200300159Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON LONGITUDINAL FLOORBEAM 6 INCHES FORWARD OF FR 18, RBL 49. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOORBEAM FR 18, RBL 49; FSDR AWXA200300152Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM MOUNT HOLE JUST FORWARD OF FR 66, BS 3155. MAINTENANCE REMOVED DAMAGED SECTION OF FLOORBEAM BETWEEN FR 64 - 66, BS 3155; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM; INSTSDR AWXA200300151Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK INTERGRANULAR CORROSION WAS FOUND AT TWO HOLES ON UPPER SURFACE OF FLOORBEAM BETWEEN FR 65 - 66, BS 3101 - 3158. MAINTENANCE REMOVED DAMAGED FLOORBEAM BETWEEN FR 65 - 66, BS 3101 - 3158; FABRICATED A NEW REPLACEMENT FLOORSDR AWXA200300150Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND AROUND SEVEN FASTENER HOLES ON LT FLOORBEAM BETWEEN FR 66 - 68, BS 3158. MAINTENANCE REMOVED DAMAGED LT FLOORBEAM BETWEEN FR 66 - 68, BS 3158; FABRICATED A NEW REPLACEMENT FLOORBEAM; INSTALSDR AWXA200300149Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM MOUNT HOLE FR 64 - 65, BS 3O72. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOORBEAM BETWEEN FR 64 - 66, BS 3072; FABSDR AWXA200300148Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON THE RT FLOORBEAM BETWEEN FR 66 - 67, BS 3231. MAINTENANCE REMOVED DAMAGED SECTION OF FLOORBEAM BETWEEN FR 66 - 67, BS 3231; FABRICATED A NEW REPLACEMENT SECTION OF FLOORBEAM; INSTALLED RSDR AWXA200300147Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON THE RT FLOORBEAM ABOVE FR 68, BS 3257. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOOR BEAM ABOVE FR 68, BS 3257; FABRICATED ASDR SWAA030293Floorbeam · crackedDURING SCHEDULED D CHECK, FOUND LONGITUDINAL FLOORBEAMS CRACKED (2 EA) AT BS 662, WL 206 AND RBL 25 AND BS 727A + 18, WL 208 AND RBL 27. REPAIRED FLOORBEAMS PER SRM.SDR 2003UALA00153Floorbeam · crackedCABIN FLOOR INTERCOSTAL UPPER FLANGE CRACKED AT FASTENER HOLES, STA 927-947 AT CENTERLINE. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR ANGLE.SDR AWXA200300161Angle · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK CORROSION WAS FOUND ON R/H FLOOR ATTACH ANGLE BETWEEN FR 33 - 34, FORWARD CARGO COMPARTMENT. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED FLOOR ATTACH ANGLE FR 33 - 34; FABRICSDR P5CA0300793Floorbeam · corrodedSTA 2320 / LBL 20 WL 208 CORROSION ON FLOORBEAM UPPER TEE. CORRODED AREA TRIMMED OUT, REINFORCED AREA PER SRM 53-11-25.SDR 0300435512Floorbeam · crackedDURING "H" CHECK FOUND CRACK IN FLOORBEAM AT BS 700 LBL 45. REPAIRED PER EA 55-193441.SDR AWXA200300160Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK INTERGRANULAR CORROSION WAS FOUND ON LONGITUDINAL FLOORBEAM FR 16, RBL 8. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOORBEAM FR 16, RBL 8; FABRICATED REPAIR ANGSDR AWXA200300158Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK INTERGRANULAR CORROSION WAS FOUND ON LONGITUDINAL FLOORBEAM FR 16, RBL 28. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOORBEAM FR 16, RBL 28; FABRICATED REPAIR ASDR AWXA200300155Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON LONGITUDINAL FLOORBEAM FR 20, RBL 28. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOORBEAM FR 20, RBL 28; FABRICATED REPAIR ANGSDR AWXA200300154Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK EXFOLIATION CORROSION WAS FOUND ON LONGITUDINAL FLOORBEAM FR 20, RBL 8. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF FLOORBEAM FR 20, RBL 8; FABRICATED REPAIR ANGLESDR AWXA200300153Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-04 CHECK INTERGRANULAR CORROSION WAS FOUND ON FLOORBEAM BETWEEN FR 68 - 69 L/H SIDE, BS 3257 - 3310. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED FLOORBEAM FR 68 - 69, BS 3257 - 3310; SDR P5CA0300761Floorbeam · corrodedLEVEL 1 CORROSION ON FLOORBEAM AND SEAT TRACK STA 1760-1880 LBLM & RBLM WL 208.SDR P5CA0300760Floorbeam · corrodedLEVEL 1 CORROSION FOUND ON FLOORBEAM STA 2320/LBL 20/WL 208. CORRODED AREA TRIMMED OUT. REINFORCED AREA PER SRM 53-11-25.SDR 03FDEA00106Floorboard · damagedN01110) FLOORBEAM UPPER FLANGE HAS A FIGURE EIGHT FASTENER HOLE. (BS 500, RBL 1, WL 208) REMOVED DAMAGED FLOORBEAM SECTION AND REPAIRED. (BS 500 FLOOR BEAM AT RBL 1, WL 208 IAW SRM 53-10-8SDR P5CA0300792Floorbeam · corrodedSTA 1800 LBL / RBL -5 / WL 2008 CORROSION ON THE FLOORBEAM UPPER CHORD. ACCOMPLISHED WORK PER SRM 51-40-03 FIG -3.SDR ABXA030094Floorbeam · corrodedFLOORBEAM SEVERLY CORRODED AT AFT LOWER CARGO DOOR HOLD-OPEN HOOK, FS 937, RIGHT BUTT LINE 12. REPAIRED FLOORBEAM IAW DC-9 SSRM K07411.SDR DHL2003740515Floorbeam · crackedAFT CARGO COMPT AFT PIT FLOORBEAM AT RBL 15 IS CRACKED AT NUT PLATE STA 950E. REMOVED FASTENERS PER SRM 51-30-2. FABRICATED DOUBLER ANGLES (2024-T3 .050) PER SRM 51-40-3. TREATED AND PRIMED PER SRM 51-10-2. INSTALLED REPAIR PER SRM 51-30-2.SDR DHL2003740506Floorbeam · crackedAFT CARGO COMPT AFT PIT FLOORBEAM AT RBL 15 IS CRACKED AT NUT PLATE STA 950E. REMOVED FASTENERS PER SRM 57-30-2. CUT OUT DAMAGED AREA 2 PLACES PER SRM 51-40-3 FIG 3. FABRICATED DOUBLER ANGLES (2024 T3) .050 PER SRM 51-30-2. TREATED AND PRIMED PER SRM 51-30SDR SWAA030262Beam · crackedDURING SCHEDULED D CHECK, FOUND LONGITUDINAL BEAM CRACKED AT BS 727A, RBL 43, WL 208. REPAIRED BEAM PER BFG ER.SDR P5CA0300759Floorbeam · corrodedLEVEL 1 CORROSION FOUND ON FLOORBEAM STA 1800 LBL/RBL-5/WL 208. ACCOMPLISHED WORK PER SRM 51-40-03 FIG 3.SDR 2003UALA00127Floorbeam · corrodedCABIN FLOORBEAM UPPER FLANGE HAD EXCESSIVE CORROSION AT STATION 360 RBL 5 IN TO LBL 18IN STRINGER 17L-17R. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SECTION OF T-CAP MOUNTED ON AFT SIDE OF VERTICAL WEB WITH 9.5 IN, L-ANGLE SPLICES FWD AND AFT OF EACH CUT, FOURSDR 03FDEA00105Floorbeam · corrodedN01087) CORROSION ON FLOORBEAM ( BS 344, LBL 25 TO RBL 25, WL 208). REMOVED CORROSION FROM FLOORBEAM (BS 344 LBL 25 TO RBL 25) MATERIAL REMOVED .035 INCH X 1 X 20 INCH, O.T. .100 INCH DETERMINED TO BE OUT OF LIMITS IAW SRM 53-10-1. FABRICATED NEW UPPER CHORSDR 03FDEA00104Floorbeam · corrodedN01056) CORROSION AT BS 1070, WL 208, RBL 30 UPPER SURFACE ON FLOORBEAM. FOUND PREVIOUS REPAIR TO BE OUT OF LIMITS IAW SRM 53-10-1. FABRICATED NEW REPAIR ANGLE AND FILLER FROM BAC 490-2883 7075T6 .090" LOT NR 179279 AND BAC 1505-100880, LOT NR458274. INSDR 03FDEA00098Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER FLANGE.SDR SIMA200304102Floorbeam · corrodedDURING AN IMBV INSPECTION, THE RIGHT FLOORBEAM WAS FOUND TO BE CORRODED BEYOND SRM LIMITS AT FRAME 23. BLENDED THE DAMAGE AREA TO COMPLETELY REMOVE THE CORROSION. APPLIED ALODINE AND EPOXY PRIMER TO THE REPAIR AREA. FABRICATED A U-SHAPED DOUBLER. REPAIR DOSDR SIMA200304809Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, THE RIGHT FLOORBEAM WAS FOUND TO BE CORRODED BEYOND SRM LIMITS AT FRAME 23. BLENDED THE DAMAGE AREA TO COMPLETELY REMOVE THE CORROSION. APPLIED ALODINE AND EPOXY PRIMER TO THE REPAIR AREA. FABRICATED A U-SHAPED DOUBLER. REPSDR F3LA200300057Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED FLOORBEAM AT STA 312 CORRODED FROM LBL 1 TO LBL 31. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-51, PARA 114, DETAIL XI. FABRICATED AND INSTALLED REPLACEMENT PART PER SRM 53-10-51 AND 51-40-02.SDR SWAA030254Floorbeam · crackedDURING SCHEDULED D CHECK, FOUND FLOORBEAM CRACKED AT BS 947.5, WL 208 AND LBL 54. REPAIRED FLOORBEAM PER BFG ER.SDR PCAA0301030Floorbeam · crackedMDT- DURING ROUTINE MAINTENANCE VISIT WHILE PERFORMING A 3 INSPECTION, CRACK WAS FOUND ON FRAME SECTION 85310380 IN FLOOR BEAM FRAME AT STATION X97.0, NOSE GEAR WELL. CRACK WAS REPAIRED IN ACCORDANCE WITH DEHAVILLAND REPAIR DRAWING RD8-53-4521 AS AN INTERIM RE
Back to JASC 5315