JASC 5315

Service difficulty reports · 44,223

Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5315'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CALA0300083Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED IN AFT GALLEY AREA AT STA 967, LBL 25. REPAIRED IAW ECRA 5320-01726.Mar 2, 2003 · N14308 · Boeing 7373T0SDR AWXA200300283Floorbeam · corrodedDURING C-03 CHECK CORROSION WAS FOUND ON UPPER AND LOWER SURFACE OF FLOORBEAM FR 66 - FR 69, Y1292. MAINTENANCE REMOVED CORRODED FLOORBEAM FROM FR 64 TO FR 69; FABRICATED A NEW REPLACEMENT FLOORBEAM; INSTALLED REPAIR PART IAW A320 SRM 51-42-11, PG. 5-20, & 39-Mar 1, 2003 · N629AW · Airbus A320231SDR AWXA200300282Floorbeam · corrodedDURING C-03 CHECK CORROSION WAS FOUND ON UPPER AND LOWER SURFACE OF FLOORBEAM FR 66 - FR 68, RBL 48, Y1292. MAINTENANCE REMOVED CORRODED FLOORBEAM FROM FR 66 TO FR 69; FABRICATED A NEW SECTION OF REPLACEMENT FLOORBEAM AND TWO EACH SPLICES; INSTALLED REPAIR PARMar 1, 2003 · N629AW · Airbus A320231SDR AWXA200300263Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-03 CHECK CORROSION WAS FOUND ON UPPER AND LOWER SURFACE OF CABIN FLOORBEAM AT FR 66+7, Y919. MAINTENANCE REMOVED CORRODED FLOORBEAM AT FR 66+7, Y919; FABRICATED A NEW REPLACEMENT FLOORBEAM; INSTALLED REPAIR PART IAW A320 SRM 51-42Mar 1, 2003 · N629AW · Airbus A320231SDR AWXA200300260Splice · corrodedMCN - MAJOR REPAIR - DURING C-03 CHECK CORROSION WAS FOUND ON THE BOTTOM SURFACE OF THE UPPER LEG ON FLOORBEAM SPLICE, FR 66+7, Y765. MAINTENANCE REMOVED CORRODED SPLICE AT FR 66+7, Y765; FABRICATED A NEW REPLACEMENT SPLICE; INSTALLED REPAIR PART IAW A320 SRM Mar 1, 2003 · N629AW · Airbus A320231SDR AWXA200300248Floorbeam · corrodedMCN - MAJOR REPAIR - DURING C-03 CHECK CORROSION WAS FOUND ON UPPER AND LOWER SURFACE OF CABIN FLOORBEAM AT FR 66-4, Y765. MAINTENANCE REMOVED DAMAGED FLOORBEAM AT FR 66-4, Y765; FABRICATED A REPLACEMENT FLOORBEAM; INSTALLED REPAIR PART IAW A320 SRM 51-42-11, Mar 1, 2003 · N629AW · Airbus A320231SDR AWXA200300245Floorbeam · corrodedDURING C-03 CHECK CORROSION WAS FOUND ON THE UPPER AND LOWER SURFACE OF CABIN FLOORBEAM AT Y512, FR 66 -1 TO +5. MAINTENANCE REMOVED CORRODED FLOORBEAM FROM FR 64 TO FR 70, Y512; FABRICATED A NEW REPLACEMENT FLOORBEAM; INSTALLED REPAIR PART IAW A320 SRM 51-42-Mar 1, 2003 · N629AW · Airbus A320231SDR CALA0300081Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED ON UPPER AND LOWER SURFACE OF CAP AND AT FASTENER HOLES AT STA 1006, BL 0 TO RBL 30. THE T-CAP WAS REMOVED AND REPLACED IAW SRM 51-40-04.Mar 1, 2003 · N14308 · Boeing 7373T0SDR AWXA200300291Intercostal · corrodedLCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON INTERCOSTAL WEB UNDER R/H OUTBOARD FLOORBOARD STRINGER, AFT CARGO COMPARTMENT, BS 1300 TO 1320. MAINTENANCE REMOVED CORRODED INTERCOSTAL WEB BS 1300 TO 1320; FABRICATED A NEW INTERCOSTFeb 28, 2003 · N914AW · Boeing 757225SDR UPS03240298Floorbeam · corrodedINSPECTION TYPE: C&SI, CORROSION ON FLOORBEAM TOP CAP BS 950 LBL 50. REPAIR CARRIED OUT IAW SRM EO 2003-008-022. UPS ENGINEERING FILE 7 27-53-20100.Feb 28, 2003 · N936UP · Boeing 727108CSDR AWXA200300254Strap · crackedMCN - MAJOR REPAIR - DURING C-14 CHECK A 5/16" CRACK WAS FOUND ON STRAP, LOWER SURFACE OF FLOOR BEAM, BS 344, LBL 49. MAINTENANCE REMOVED DAMAGED AREA OF STRAP; FABRICATED A REPAIR DOUBLER; INSTALLED REPAIR PART IAW B737-300 SRM 51-70-13, PG. 1-3, FIG. 1.Feb 28, 2003 · N306AW · Boeing 7373G7SDR AWXA200300252Strap · crackedMCN - MAJOR REPAIR - DURING C-14 CHECK A 5/16" CRACK WAS FOUND ON STRAP, LOWER SURFACE OF FLOOR BEAM, BS 328, LBL 16. MAINTENANCE REMOVED DAMAGED AREA OF STRAP; FABRICATED A REPAIR DOUBLER; INSTALLED REPAIR PART IAW B737-300 SRM 51-70-13, PG. 1-3, FIG. 1.Feb 28, 2003 · N306AW · Boeing 7373G7SDR AWXA200300244Floorbeam · crackedDURING C-14 CHECK A 3/4 INCH CRACK WAS FOUND ON CHANNEL BETWEEN FLOORBEAMS AT BS 328, LBL 49. MAINTENANCE REMOVED DAMAGED CHANNEL BETWEEN FLOORBEAMS AT BS 328, LBL 49; FABRICATED A NEW REPLACEMENT CHANNEL; INSTALLED REPAIR PART IAW B737-300 SRM 51-40-02, PG. 1Feb 28, 2003 · N306AW · Boeing 7373G7SDR EIA2003022Floorbeam · damagedBS 360 AT RBL 68 APPROX 2" UP FROM LOWER CHORD HAS A SHARP DENT WITH CREASED ON FLOOR BEAM WEB. REMOVED DAMAGED AREA PER B747 SRM 51-1-001. FABRICATED REPAIR PARTS: -1 DOUBLER, -2 TRIPLER, -3 FILLER & -4 FILLER PER ECRA 481-53-185-2. ALODINED PER B747 SRM 5Feb 27, 2003 · N481EV · Boeing 747132SDR C2XA03SH030Floorbeam · crackedSHV- DURING C-CHECK A RAMP ANGLE WAS FOUND CRACKED ON LEFT HAND FLOORBEAM FOWARD OF FRAME 20. MAINTENANCE REMOVED DAMAGE AND PERFORMED AND ANGLE REPAIR IAW EMB SRM 51-30-01. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.Feb 27, 2003 · N13936 · Emb EMB145ERSDR 03FDEA00183Floorbeam · corrodedCORROSION ON FLOORBEAM REPAIR STRAP BS 1130, RBL 30-RBL 36, WL 200. REMOVED CORROSION ON FLOORBEAM REPAIR STRAP BS 1130, FOUND TO BE OUT OF LIMITS, REMOVED DAMAGED STRAP, FABRICATED AND INSTALLED NEW STRAP IAW SRM 51-10-2, 51-10-3, 51-30-2, AND 51-30-5.Feb 26, 2003 · N464FE · Boeing 727225SDR 03FDEA00181Floorbeam · corrodedCORROSION ON FLOORBEAM LOWER FRAME AROUND NUT PLATE HOLES, B.S.720, LBL 16 TO LBL 21, W.L. 200 AT PREVIOUS REPAIR.Feb 26, 2003 · N464FE · Boeing 727225SDR AALA20030307Floorbeam · corrodedAFW - FLOORBEAM AT STATION 347 HAS CORROSION ON UPPER SURFACE REMOVED. MATERIAL REMAINING IS BEYOND SRM LIMITS, REQUEST ENGINEER APPROVAL TO REPAIR PER SKETCH. REMOVED EXISTING REPAIR STRAPS TO INCORPORATE SINGLE STRAP. REMOVED CORROSION PER REF B AND VERIFIFeb 25, 2003 · N366AA · Boeing 767323SDR AALA20030308Floorbeam · corrodedAFW - UPPER SURFACE OF FLOORBEAM STATION 764 HAD CORROSION BLENDED BEYOND SRM LIMITS. REMOVED CORROSION PER REF B. VERIFY CORROSION COMPLETELY REMOVED. FABRICATE AND INSTALLED REPAIR STRAP. (M)Feb 25, 2003 · N366AA · Boeing 767323SDR F3LA200300091Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON CARGO FLOOR BEAM AT STA. 772, LBL 12, AT FLOOR PANEL SPLICE STRIP, BOTTOM SIDE OF UPPER FLANGE. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-10-5 AND SOPM 20-41-02.Feb 25, 2003 · N921WA · Boeing 7372Y5SDR 03FDEA00169Floorbeam · corrodedCORROSION ON FLOORBEAM REPAIR FILLER B.S. 1070, RBL 42 TO LBL 36. REMOVED CORROSION ON FLOORBEAM REPAIR FILLER BS 1070. FOUND TO BE OUT OF LIMITS. REMOVED FILLER, FABRICATED REPLACEMENT AND INSTALLED IAW SRM 53-10-1, 53-10-8.Feb 24, 2003 · N464FE · Boeing 727225SDR 03FDEA00167Floorbeam · corrodedCORROSION ON FLOORBEAM, UPPER FLANGE AT BS 680 RBL 11, DAMAGED ON REPAIR DOUBLER, NO DAMAGE LIMITS ON REPAIR DOUBLER, REPAIRED FLOORBEAM AT BS 680, WL 208, RBL 11, IAW SRM 53-10-8 FIG 3.Feb 24, 2003 · N464FE · Boeing 727225SDR SWIA200311839Floorbeam · crackedFS 621.0 LEFT FLOORBEAM ANGLE LBL 42 CRACKED. FOUND DURING C-CHECK INSPECTION. DAMAGED AREA REPAIRED IAW CRJ REO 601R-53-61-117.Feb 21, 2003 · N908SW · Cndair CL6002B19SDR SWIA200311836Floorbeam · crackedFS 280 RBL AND LBL 9.0 INBOARD AND OUTBOARD FLOORBEAM ANGLES CRACKED. FOUND DURING C-CHECK INPSECTION. REPLACED ANGLES IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13, 51-42-21 AND 51-23-00.Feb 21, 2003 · N908SW · Cndair CL6002B19SDR DL757030188Floorbeam · corrodedTHE UPPER CAP OF THE FS 1681 FLOORBEAM WAS FOUND WITH MULTIPLE AREAS OF CORROSION. THE UPPER CAP FLANGE WAS TRIMMED OFF FROM END TO END (LBL 61 - RBL 61). A NEW CAP WAS FABRICATED FROM ALUMINUM EXTRUSION AND INSTALLED ON THE FLOORBEAM. THE REPAIR WAS ACCOMPFeb 21, 2003 · N652DL · Boeing 757232SDR 2003740522Floorbeam · misrepairedAFT CARGO COMPT FLOORBEAM AT RBL 12 HAS IMPROPER REPAIR AT STA 950C. REMOVED FLOORBEAM RBL 12 BS 950C FOR REPAIR IAW SRM 51-30-2. FABRICATED NEW FLOORBEAM AND SPLICE DIM OF BEAM 2 INCHES X 57 INCHES AND SPLICE DIM 2 INCHES X 6.5 INCHES IAW SRM 53-10-5 FIG 4.Feb 21, 2003 · N740DH · Boeing 727200SDR 03FDEA00157Floorbeam · corrodedCORROSION ON FLOORBEAM UPR FLANGE BS 1110, RBL 57 TO LBL 57, WL 208.Feb 21, 2003 · N464FE · Boeing 727225SDR 03FDEA00158Floorbeam · corrodedCORROSION ON 950F FLOORBEAM UPPER FLANGE UPPER AND LOWER SURFACE FROM LBL 55 TO RBL 55, WL 208.Feb 21, 2003 · N464FE · Boeing 727225SDR 03FDEA00145Floorbeam · corrodedCORROSION ON TOP OF UPPER LOBE FLOORBEAM AT BS 560, RBL 3 TO RBL 23. CORROSION ON TOP OF FLOORBEAM AT BS 560, RBL 3 TO 13, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED AREA. FABRICATED, LOCATED, DRILLED, ALODINED, PRIMED, SEALED, AND INSTALLED REPAIR CHORD Feb 20, 2003 · N464FE · Boeing 727200SDR 03FDEA00144Floorbeam · corrodedCORROSION ON FLANGES OF LONGITUDINAL FLOORBEAM BS 760-848, LBL 25, WL 208. REMOVED DAMAGE LONGITUDINAL BEAM, BS 760-848, LBL 25, WL 208, FABRICATED, ALODINED, PRIMED, AND INSTALLED REPLACEMENT LONGITUDINAL BEAM IAW SRM 51-30-2, 51- 30-5, 53-10-2, 51-Feb 20, 2003 · N464FE · Boeing 727200SDR UPS03240280Floorbeam · corrodedINSPECTION TYPE: C&SI, CORROSION ON FLOORBEAM TOP CAP BS 344 RBL 24.75 TO 24.75 LBL. CORROSION REMOVED IAW SRM 51-10-6 DEPTH OF BLEND-OUTS MEASURED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-01 IN SEVERAL AREAS. FLOORBEAM TOP CHORD REPLACED IAW BOEING DRAWFeb 19, 2003 · N936UP · Boeing 727108CSDR F3LA200300075Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM CAP AT STA. 312, LBL 13 TO RBL 10. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-01. FABRICATED AND INSTALLED NEW CAP PER SRM 53-10-1.Feb 19, 2003 · N921WA · Boeing 7372Y5SDR F3LA200300076Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT SCREW HOLE, STA. 328, LBL 29. REMOVED TOP CAP REPAIR ANGLE, FABRICATED AND INSTALLED REPAIR ANGLE TO TOP CAP PER SRM 51-40-02.Feb 19, 2003 · N921WA · Boeing 7372Y5SDR 03FDEA00138Floorbeam · corrodedCORROSION ON FLOORBEAM LOWER CHORD AROUND NUT PLATE HOLES, BS 1070, RBL 34, WL 200. CORROSION ON 1070 FLOORBEAM WAS OUT OF LIMITS FROM LBL 45 TO RBL 45 WL 200. CUT OUT LWR CHORD AND REPAIRED 1070 FLOORBEAM LOWER CHORD IAW EA 7-5310-68199 AND SRM 53-10-8 FFeb 19, 2003 · N267FE · Boeing 727233SDR F3LA200300069Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON CARGO FLOORBEAM BETWEEN STA 727 AND 727A, LBL 3, AT NUT PLATE ON UNDERSIDE OF FLANGE. FABRICATED AND INSTALLED FLOOR SUPPORT AND SPLICE PER SRM 53-10-3, FIG 11, AND SOPM 20-41-02.Feb 18, 2003 · N921WA · Boeing 7372Y5SDR F3LA200300068Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON CARGO FLOORBEAM BETWEEN STA 727 AND 727A, RBL 3, AT NUT PLATE ON UNDERSIDE OF UPPER FLANGE. FABRICATED AND INSTALLED FLOOR SUPPPORT AND SPLICE PER SRM 53-10-3, FIG 11, AND SOPM 20-41-02.Feb 18, 2003 · N921WA · Boeing 7372Y5SDR F3LA200300065Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM CAP AT STA 344, LBL 60 - RBL 14. REMOVED DAMAGE ON WEB BETWEEN STA 332 AND STA 344 AFT OF R-1 DOOR PER SRM 51-40-2, PAGES 1-3. FABRICATED AND INSTALLED REPAIR PER SRM 51-40-02, PAGES 1-3, AND SOPM Feb 18, 2003 · N921WA · Boeing 7372Y5SDR C2XA03SH004Butt Strap · corrodedDURING C-CHECK, BUTTSTRAP ON THE CENTER FLOORBEAM BETWEEN FRAMES 18 TO 23 WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BUTTSTRAP IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.Feb 18, 2003 · N13949 · Emb EMB145LRSDR F3LA200300063Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED FLOORBEAM CAP CORRODED AT STA 290, RBL 15. FABRICATED AND INSTALLED REPLACEMENT CAP STRIP PER SRM 53-10-2 AND 53-10-9.Feb 17, 2003 · N921WA · Boeing 7372Y5SDR SIMA200307106Floorbeam · corrodedTHIS IS A LEVEL 2 FINDING, DURING AN IMBV INSPECTION RIGHT OMEGA BEAM TRIANGLE CAP AT FRAME 19 CORRODED. REOVED AND INSTALLED NEW TRIANGLE CAP IAW 135 SRM 51-40-02, 51-20-03, 51-40-04 AND 51-40-06. (M)Feb 16, 2003 · N703MR · Emb EMB135LRSDR ARWA20030217Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOOR BEAM SPLICE PLATES AT STATION 460 STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 460 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR ARWA20030216Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 440 STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 440 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR ARWA20030215Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 420 STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 420 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR ARWA20030214Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 400 STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 400 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR ARWA20030213Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 380, STRINGER 21. REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 380 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR ARWA20030212Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 360, STRINGER 21. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM SPLICE PLATES AT STA 360 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR ARWA20030210Floorbeam · crackedDURING AD INSPECTION (NOTE AD 2001-26-01/SID 53.08.FC4-10) FOUND CRACKS AT FLOORBEAM SPLICE PLATES AT STATION 340, STRINGER 21. REMOVED AND REPLACED FLOOR BEAM SPLICE PLATES AT STA 340 IAW STC SA1063SO AND SA1377SO.Feb 15, 2003 · N8968U · Doug DC862SDR CALA0300049Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 986, BL 0 TO LBL 18. THE UPPER CHORD OF FLOORBEAM WAS REMOVED AND REPLACED IAW ECRA 5310-03851, REV. B.Feb 15, 2003 · N17309 · Boeing 7373T0SDR AALA20030437Floorbeam · corrodedFOUND FLOORBEAM FROM LBL 43 TO LBL 24, FLOOR SUPPORT CORRED FS 1155. FABRICATED NEW SUPPORT WITH EXTRUSION CRN4018034. TREATED PART AND INSTALLED PER SRM 51-10-35, 51-80-1. (M)Feb 14, 2003 · N9615W · Doug DC983SDR CALA0300097Floorbeam · corrodedINSPECTION FOUND FLOORBEAM UPPER CHORD CORRODED AT STA 344 BETWEEN LBL 36 AND RBL 12. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED AND REPLACED IAW SRM 53-10-51.Feb 14, 2003 · N17309 · Boeing 7373T0
Back to JASC 5315