SDR USAA010193Floorbeam · corrodedCLT - FOUND FLOORBEAM FLANGE CORRODED 1 INCH BY 2 INCHES, 6 PLACES, BS 344, BL 0, RBL 12, 18, 33, 40, 54, LBL 12, 28. INSTALLED REPAIR ANGLE AND T-CAP PER SRM 53-10-51 FIG 205. (M)SDR RRXA010677Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CENTER WING FLOOR BEAM AT STA 857 X+60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O.#01-024 WITH APPROVED 8110-3 DATED 02/26/SDR 20010425AP016Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION MAINTENANCE REPORTED FLOORBEAMS 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAMS IAW SRM 51-25-01. AIRCRAFT WAS RETURNED TO SERVICE. REF SIMA07811 (M)SDR 20010425AP015Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION MAINTENANCE REPORTED FLOORBEAMS 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAMS IAW SRM 51-25-01. AIRCRAFT WAS RETURNED TO SERVICE. REF SIMA07811 (M)SDR SIMA07811Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION MAINTENANCE REPORTED FLOORBEAMS 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAMS IAW SRM 51-25-01. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR ASAA0140032Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON UPPER CHORD OF FLOORBEAM. REMOVED AND REPLACED IAW SRM. (M)SDR ASAA0140030Floorbeam · corrodedPAE - DURING SI CHECK, FOUND CORROSION ON FLOORBEAM. REPAIRED IAW SRM. (M)SDR 20010524SG012Floorbeam · corrodedDURING CPCP-2 INSPECTION MAINTENANCE REPORTED FLOORBEAMS 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAMS IAW SRM 51-25-01. AIRCRAFT WAS RETURNED TO SERVICE. REF SIMA200107301. (M)SDR 20010524SG011Floorbeam · corrodedDURING CPCP-2 INSPECTION MAINTENANCE REPORTED FLOORBEAMS 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAMS IAW SRM 51-25-01. AIRCRAFT WAS RETURNED TO SERVICE. REF SIMA200107301. (M)SDR SIMA200107301Floorbeam · corrodedDURING CPCP-2 INSPECTION MAINTENANCE REPORTED FLOORBEAMS 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAMS IAW SRM 51-25-01. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR USAA010405Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED, .5 INCH BY 1 INCH IS LARGEST, 1 INCH, .75 INCH, AND .25 INCH STATION 996.5 LBL 50 RBL 50. PER TYPICAL REPAIR 53-15-01B. (M)SDR 2001UALA00253Floorbeam · crackedSTA. 246 DISCREPANCIES: BUCKLED VERTICAL STIFFENERS AT RBL 7.88, 50.0 CRACKED VERTICAL STIFFENERS AT RBL 26.06, 38.0 CRACKED MID CHORD AT RBL 38.0 CRACKED FLOORBEAM WEB AT RBL 38.0 SUPPLEMENTAL DATA UPDATE REPLACED STIFFENERS PER SRM 53-10-51, REPAIR 3. REPAISDR 0101082284Floorbeam · corrodedDURING H-CHECK, FOUND CORROSION ON FLOORBEAM AT BS 1110 RBL 25 TO LBL 45. REPAIRED PER EA 22-182194.SDR SWAA010546Floorbeam · crackedDURING SCHEDULED 1/4D CHECK, FOUND FLOORBEAM CRACKED AT BS 400, RBL 14. REPAIRED FLOORBEAM PER SRM.SDR TWAA0103701Floorbeam · corrodedDURING CHECK-C MAINT FOUND FLOORBEAM/CEILING SUPPORT CORRODED ALONG STA 1308, 20 INCHES INBD OF LONGERON 19L. REPAIRED FLOORBEAM AT STA 1308 PER SRM 53-05 FIG 79 SHEET 8-9-10, ARA 17629 PAGE 1-2-3, SRM 51-60-0, SRM 51-20-0, AND SRM 51-10-3.SDR AALA20010365Floorbeam · crackedTUL - FOUND FLOORBEAM WEB CRACKED STATION 875 LBL 61. INSTALLED FAB WEB AT FLOORBEAM AT STATION 825 LBL 61 SRM 51-40-2. (M)SDR F3LA200100032Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED AFT FUSELAGE FLOORBEAM AT STA 986.5 CORRODED ACROSS TOP. MAINTENANCE FABRICATED AND INSTALLED REPLACEMENT FLOOR BEAM PER SRM 53-00-51.SDR F3LA200100031Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT CARGO COMPARTMENT FLOOR SUPPORT BEAM AT STA 867, RBL 15. MAINTENANCE REPLACED FLOOR SUPPORT BEAM PER SRM 51-30-02 AND 51-10-02.SDR F3LA200100030Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT FLOORBEAM CORRODED AT STA 847, STR 26R. MAINTENANCE REPLACED FLOORBEAM SUPPORT STRAP AND WEB PER SDR 51-10-02.SDR 0101072284Floorbeam · corrodedDURING H-CHECK, FOUND CORROSION ON FLOORBEAM AT BS 380 BETWEEN RBL 2 AND RBL 65. REPAIRED PER EA 22-182195.SDR USAA010233Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1.5 INCH, STATION 294.5, 12 INCHES LEFT OF CENTER. FILLED VOID WITH SEALANT PER EA 69083. (M)SDR CALA0100147Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 986.5, LBL 48 TO RBL 48. THE FLOORBEAM WAS REPAIRED IAW ECRA 5310-04093.SDR F3LA200100027Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ACROSS TOP OF AFT FUSELAGE FLOORBEAM INTERCOSTAL CAP, STA 951.5, BETWEEN 26 LBL AND 50 LBL. MAINTENANCE REMOVED FLOORBEAM INTERCOSTAL, AND FABRICATED, PRIMED AND INSTALLED REPLACEMENT FLOORBEAM INTERCOSTAL PER ESDR 20010410AP002Floorbeam · corrodedDURING ANNUAL INSPECTION DISCOVERED SEVERE INTERGRANULAR CORROSION ON LEFT 4 INCHES OF ANGLE. CORROSION OCCURED PRIMARILY WHERE .25 IN. HI-SHEAR RIVITS ATTACH ANGLE TO BULKHEAD AND WING LIFT STRUT ATTACH FITTING. ANGLE WAS LESS THAN HALF ORIGINAL THICKNESS SDR AWXA0001376Floorbeam · crackedFWD CARGO PIT UPPER FLOORBEAM STA 560 RBL 0 INTERCOSTAL CRACKED. REMOVED, FABED AND INSTALLED ANGLE IAW SRM 53-30-51, 51-30-02, AND 51-40-02.SDR AWXA0001379Floorbeam · crackedFWD CARGO PIT STA 660 BL 0, UPPER FLOORBEAM INTERCOSTAL IS CRACKED. REMOVED, FABED AND REPLACED ANGLE IAW SRM 53-30-51, 51-30-01 FIG 7, 51-40-02.SDR AWXA0001380Floorbeam · crackedFWD CARGO PIT UPPER FLOORBEAM INTERCOSTAL IS CRACKED AT STA 780-800 BL 0. REMOVED, FABED AND REPLACED UPPER INTERCOSTAL ANGLE IAW SRM 53-30-51, 51-40-02, 51-20-05.SDR AWXA0001385Floorbeam · crackedFWD CARGO PIT STA 680 RBL 20 INTERCOSTAL IS CRACKED AT ITS UPPER CHORD (UPPER FLOORBEAM). REMOVED, FABED AND INSTALLED INTERCOSTAL REPAIR ANGLE IAW SRM 51-30-01 AND ENGINEERING SUPPORT; TREATED AND PRIMED IAW SRM 51-20-01.SDR F3LA200100024Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOORBEAM AT STA 947.5. MAINTENANCE REMOVED FLOORBEAM, FABRICATED, TREATED, PRIMED AND INSTALLED REPLACEMENT FLOORBEAM PER SRM 53-00-51.SDR USAA010241Floorbeam · corrodedCLT - FOUND CORROSION 3 INCHES BY 108 INCHES, STATION 986.5 LBL 54 TO RBL 54. SPLICED IN NEW T-CAP PER TYP REP 53-50-01. CORROSION LEVEL 1. (M)SDR CALA0100129Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAP UPPER AND LOWER FLANGE CORRODED AT STA 312, RBL 12. THE UPPER CAP WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 53-10-51, FIGURE 205.SDR 2001UALA00197Floorbeam · crackedCRACKED STA 246 FLOORBEAM MID CHORD AT CUTOUT- LBL 38.5, BUCKLED STIFFENERS STA 246 FLOORBEAM - RBL 7 AND 26. *S/D* REPAIR CRACK PER SRM 53-10-51, REPAIR 1, PAGE 201. REPLACED STIFFENERS PER SRM 53-10-51, REPAIR 3, PAGE 201.SDR DHL2001702004Floorbeam · corrodedAT FS 1050 LBL 3 ON BOTTOM OF FLOORBEAM WL 200 CORROSION ON FLOORBEAM AND GILLINER ATTACH ANGLE. REMOVED AND REPLACED LOWER SUPPORT TEE.SDR UPS01235228Floorbeam · corrodedINSPECTION TYPE:C+SI, CORROSION ON FLOORBEAM TOP CAP BS 344 BETWEEN LBL 10 & RBL 14. FLOORBEAM REPAIRED IAW SRM 53-10-8.SDR USAA010247Floorbeam · corrodedCLT - FOUND FLOOR FRAME CORRODED 4 SQUARE INCHES, STATION 987.5 LBL 14, RBL 15, RBL 24. REPLACED T-CAP FROM LEFT AND RIGHT EXTREMITIES PER TYP REP 53-60-01. CORROSION LEVEL 1, TASK NR C53-107-02. (M)SDR USAA010246Floorbeam · corrodedCLT - FOUND FLOOR FRAME CORRODED 12 SQUARE INCHES, BS 947.5 LBL 30 - RBL 49. FABRICATED T-CAP AND SPLICE PARTS PER 53-10-9. CORROSION LEVEL 1, TASK NR C53-107-02. (M)SDR UPS01235256Floorbeam · corrodedINSPECTION TYPE:C+SI, CORROSION FOUND ON FLOORBEAM TOP CAP BS 950 RBL 55. REPAIRED IAW SMRO EO 2001-006-017.SDR 01FDEA00129Floorbeam · corrodedCORROSION (C53-224-01) ON BS 312 FLOORBEAM UPPER CHORD LBL 4, WL 208. *S/D* OUT OF LIMITS PER IAW FEDEX SRM 53-10-1. FAB ANGLE AND FILLER PER IAW FEDEX SRM DWG 27-53-017. INSTALLED ALL FASTENERS PER IAW FEDEX SRM 51-30-5, 51-30-2 AND MM 51-20-151.SDR 01FDEA00128Floorbeam · corrodedCORROSION (C53-224-01,1) ON BS 328 FLOORBEAM UPPER CHORD, LBL 4, WL 208. *S/D* OUT OF LIMITS PER FEDEX SRM 53-10-1. REMOVED AND REPLACED PER FEDEX DWG SR 27-53-017.SDR EISA20010057Floorbeam · gougedDURING ROUTINE C-CHECK INSPECTION FOUND GOUGE AT MAIN CABIN FLOORBEAM BS 950 AT RBL 7. FABRICATED AND INSTALLED ANGLES, FILLER AND FLOORBEAM T-CAP AT BS 950 RBL 45 TO LBL 45, ALODINED AND PRIMED IAW SRM 53-10-2, 51-10-2, 53-10-8 FIG 8, 51-30-2.SDR EISA20010054Floorbeam · corrodedDURING ROUTINE C-CHECK INSPECTION FOUND CORROSION UNDER NUT PLATE ON FLOOR ANGLE AT BS 1148 12 FT LEFT OF BL 0 UNDER FLOOR SIDE. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER AT BS 1148 LBL 12, ALODINED AND PRIMED IAW SRM 53-10-8 FIG 8, 51-10-2, 51-10-6,SDR EISA20010051Floorbeam · corrodedDURING ROUTINE C-CHECK INSPECTION FOUND CORROSION AT BS 620 WL 208 RBL 65 TO RBL 70 FLOORBEAM UPPER CHORD LOWER SECTION. FABRICATED AND INSTALLED REPAIR ANGLE AT BS 620 WL 208 RBL 65 TO RBL 70, ALODINED AND PRIMED REPAIR ANGLE IAW SRM 53-10-8 FIG 3, 51-10-2, SDR EISA20010059Floorbeam · corrodedDURING ROUTINE C-CHECK INSPECTION FOUND FLOORBEAM AT BS 1130 CORRODED AT NUT PLATES FROM RBL 62.5 TO LBL 62.5. FABRICATED AND INSTALLED REPAIR ANGLE AND RADIUS FILLER, ALODINED AND PRIMED REPAIR PARTS IAW SRM 53-10-1 FIG 5, 51-10-6, 53-10-8 FIG 8, 51-10-2, 51SDR EISA20010047Floorbeam · corrodedDURING ROUTINE C-CHECK INSPECTION FOUND FLOORBEAM AT BS 1060 LOWER LEG CORRODED. FABRICATED AND INSTALLED 2 REPAIR ANGLES, ALODINED AND PRIMED ANGLE REPAIRS IAW SRM 53-10-8 FIG 2, 51-10-2, 51-30-2.SDR QXEA0100210Floorbeam · corrodedYYC- CORROSION FOUND ON FLOORBEAM FRAME 6805 BETWEEN BL600RH AND BL1390RH. REPAIRED IAW HORIZON AIR EA 4-53-1445.SDR QXEA0100209Floorbeam · corrodedYYC- CORROSION FOUND ON FLOORBEAM FRAME 6805 BETWEEN BL600RH AND BL1390RH. REPAIRED IAW HORIZON AIR EA 4-53-1445.SDR USAA010271Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH IN SEVERAL AREAS, STATINO 312, BL 0 RBL 12, LBL 7, 32, 39. REPLACED T-CAP. (M)SDR 01FDEA00116Floorbeam · corrodedDURING ROUTINE INSP THE AFT CARGO FLOORBEAM AT BS 1130, STR 17R FOUND CORRODED. *S/D* REMOVED, REPLACED AND FAB DAMAGED AREA PER IAW FEDEX EA 7-5310-56274.SDR 01FDEA00118Floorbeam · corrodedDURING ROUTINE INSP, MAIN CABIN FLOORBEAM AT BS 950, RBL 6 FOUND CORRODED. *S/D* REMOVED, REPLACED, AND FAB PER IAW BAC 727 SRM 53-10-8.SDR F3LA200100017Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ACROSS TOP OF AFT FUSELAGE FLOORBEAM AT STA 967. REPLACED FLOORBEAM CAP AT STA 967 FROM LBL 37.5 TO RBL 36 PER SRM 53-00-51.
Back to JASC 5315