SDR F3LA99051Floorbeam · corrodedDEN - DURING C-CHECK, INSPECTION REPORTED EXFOLIATION CORROSION IN FORWARD CARGO COMPARTMENT, ARUOND FLOOR EDGE BEAM NUT PLATE, AT BS 500A, ABOVE S 26R. MAINTENANCE REMOVED FLOOR EDGE BEAM, BURNISHED CORROSION AND REPAIRED PER SRM 51-40-2. (M)Jun 3, 1999 · N271FL · Boeing 7372L9SDR COMA9960254Floorbeam · corrodedTASK 002-53-140-505 FLOORBEAM CAPS BETWEEN FS 310 TO FS 409 LBL 27, LBL 9, RBL 9 AND RBL 27 ARE CORRODED. REPLACED CORRODED SECTIONS OF FLOORBEAMS.Jun 3, 1999 · N915CA · Cndair CL6002B19SDR 99ZZZM654Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM FRAME 41 CENTER AREA BY FITTING. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL CORROSION BLENDED AND FOUND BEYOND LIMITS IAW SRM 53-61-00 FIG 301. (M)Jun 3, 1999 · N973NA · Aerosp ATR42300SDR RRXA991125Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOORBEAM UNDER SEAT TRACK 3 ABOVE LONGERON 32 LEFT AT STA 1700. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR STRAP IAW FAA APPROJun 2, 1999 · N606AL · Doug DC873FSDR RRXA991121Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOOR SUPPORT UNDER CLIP NUTS AT STA 1746 BETWEEN BL 1-1/2 LEFT AND 20-1/2. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED H CHANNEL AND INSTALLED IAW DCJun 2, 1999 · N606AL · Doug DC873FSDR RRXA991120Floorbeam · corrosionDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOOR SUPPORT AT STA 1726, BL 31 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED H CHANNEL AND INSTALLED IAW DC8 SRM 51-1-21 AND 51-1-8. (CORROSIONJun 2, 1999 · N606AL · Doug DC873FSDR RRXA991119Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION CRACKS, FUSELAGE, FLOOR SUPPORTS AT STA 1700 BL 29 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED H CHANNEL AND INSTALLED IAW DC8 SRM 51-1-21 AND 51-1-8. (COJun 2, 1999 · N606AL · Doug DC873FSDR RRXA991118Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION CRACKS, FUSELAGE, FLOOR SUPPORTS, AT STA 1680 BL 35 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED H CHANNEL AND INSTALLED IAW DC8 SRM 51-1-21 AND 51-1-8. (CJun 2, 1999 · N606AL · Doug DC873FSDR RRXA991116Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION CRACKS, FUSELAGE, FLOOR SUPPORTS, AT STA 1680, BL 14 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW SUPPORT AND INSTALLED IAW DC8 SRM 51-1-21 AND 51-1-8Jun 2, 1999 · N606AL · Doug DC873FSDR CALA9900610Floorbeam · corrodedINSPECTION FOUND LATERAL FLOOR SUPPORT BEAM CORRODED AT STA 1903 FROM POSITION X = 0.25L TO X = 0.25R. THE FLOOR SUPPORT BEAM WAS REPLACED IAW 53-16-00, FIGURE 10.Jun 2, 1999 · N83071 · Doug DC1030SDR AT9900430Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CORROSION UNDER PREVIOUS REPAIR AT THE FLOORBEAM UPPER CHORD AT BS 160 RBL 50. REMOVED FLOORBEAM DAMAGE AREA. FABRICATED REPAIR FLOORBEAM AND ANGLE, DEBURRED, COUNTERSUNK, TREATED, PRIMED AND INSTALLED REPJun 2, 1999 · N867AT · Doug DC932SDR 99T64R269ARFloorbeam · corrodedNR 2958 - CORROSION BLISTER AFT SIDE CABIN FLOORBEAM STA 1120 RBL 34 INCHES. REMOVE CORROSION IAW DC-8 SRM 51-1-8. FABRICATED DOUBLER AND INSTALLED PER EO 99-016 WITH APPROVED FAA FORM 8110-3 DATED 6-7-99. REF: ARROW AIR, ARWA. (X)Jun 2, 1999 · N1808E · Doug DC862SDR UPS99229996Floorbeam · corrodedINSPECTION TYPE:C&SI, DURING REPLACEMENT OF LT BS 940 FITTING, FLOORBEAM AT BS 940 LBL 7 0 - LBL 45 LWR CHORD, FOUND CORRODED. FLOORBEAM REPAIRED IAW EO SMRO 99-14-005 UPS ENGINEERING FILE NR 727-53-2134.Jun 1, 1999 · N927UP · Boeing 72731CSDR CALA9900604Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAPPING SECTION CORRODED AT STA 1876 FROM POSITION X = 0.27R TO X = 0.33R AND POSITION X = 0.38R TO X = 0.56R. THE FLOORBEAM CAPPING SECTION WAS REPLACED IAW SRM 53-16-00, FIGURE 10.Jun 1, 1999 · N83071 · Doug DC1030SDR CALA9900603Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAPPING SECTION CORRODED AT STA 1876 FROM POSITION X =0.04R TO X = 0.22R. THE FLOORBEAM CAPPING SECTION WAS REPLACED IAW SRM 53-16-00, FIGURE 10.Jun 1, 1999 · N83071 · Doug DC1030SDR CALA9900602Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAPPING SECTION CORRODED AT STA 1876 FROM POSITION X = 0.60R TO X = 0.90R AND POSITION X = 0.60L TO X = 0.90L. THE FLOORBEAM CAPPING SECTIONS WERE REPLACED IAW SRM 53-16-00, FIGURE 10.Jun 1, 1999 · N83071 · Doug DC1030SDR CALA9900601Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAPPING SECTION CORRODED AT STA 1876 FROM POSITION X = 0.04L TO X = 0.22L. THE FLOORBEAM CAPPING SECTION WAS REPLACED IAW SRM 53-16-00, FIGURE 10.Jun 1, 1999 · N83071 · Doug DC1030SDR CALA9900600Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAPPING SECTION CORRODED AT STA 1876 FROM POSITION X = 0.27L TO X = 0.38L. THE FLOORBEAM CAPPING SECTION WAS REPLACED IAW SRM 53-16-00, FIGURE 10.Jun 1, 1999 · N83071 · Doug DC1030SDR 99FDEA00202Floorbeam · corrodedCORROSION (C53-224-01,3) ON UPPER SURFACE OF UPPER CHORD BS 1130, RBL 47-49, WL 208. *S/D* REMOVED AND REPLACED CORROSION, FLAP PEENED AREA AND INSTALLED REPAIR STRAP PER FEDEX EA 7-5310-45275.Jun 1, 1999 · N234FE · Boeing 727247SDR CALA9900587Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 328, LBL 50 TO LBL 30. REPAIRED IAW SRM 53-10-51.May 31, 1999 · N14307 · Boeing 7373T0SDR USAA990538Floorbeam · corrodedCLT - DURING Q-4 CHECK, FOUND SEVERAL 1 INCH DRAIN CORRODED AREAS IN FLOORBEAM AT STATION 986.5 FROM LEFT CREASE BEAM TO RIGHT CREASE BEAM FLOOR LEVEL. CORROSION LEVEL 1, CORROSION TASK NR C53-107-2. REPLACED BEAM 'T' CAP PER TR 53-10-05. (M)May 29, 1999 · N510AU · Boeing 7373B7SDR USAA990476Floorbeam · corrosionCLT - DURING Q-4 CHECK, FOUND 1.5 INCH BY .5 INCH CORRODED AREA ON FLOORBEAM AROUND FLOORBOARD HOLE AT BS 412 BL 0. CORROSION LEVEL 1. INSTALLED STRAP ON AFT SIDE PER SRM 53-10-51. (M)May 29, 1999 · N510AU · Boeing 7373B7SDR CALA9900586Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CAP CORRODED AT STA 344, LBL 36 TO RBL 12. A NEW SECTION OF FLOORBEAM AND DOUBLERS WERE INSTALLED IAW SRM 53-10-51.May 29, 1999 · N10323 · Boeing 7373T0SDR UPS99829819Floorbeam · corrodedINSPECTION TYPE:C1, STA 980 AT LBL 9.5, THE FLOORBEAM FLANGE FWD SIDE HAS HEAVY CORROSION. REPAIRED AREA IAW DH SK 705-484.May 28, 1999 · N705UP · Doug DC871FSDR SWAA990939Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION ON FLOORBEAMS, BS 312, LBL 6-RBL 8, BS 294, LBL 21-RBL 24, AND BS 328 RBL 14. REPAIRED BEAM PER SRM.May 28, 1999 · N306SW · Boeing 7373H4SDR SWAA990938Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION AT FLOORBEAM, BS 294, LBL 7-11. REPAIRED BEAM PER SRM.May 28, 1999 · N306SW · Boeing 7373H4SDR SWAA990937Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION ON TOP FLANGE OF FLOORBEAM, BS 294 , RBL 23-47. REPAIRED BEAM PER SRM.May 28, 1999 · N382SW · Boeing 7373H4SDR CALA9900627Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED BETWEEN STA 1887 AND 2007 ON LT SIDE. THE FLOORBEAM WAS REPLACED IAW SRM 51-31-01.May 28, 1999 · N13066 · Doug DC1030SDR CALA9900625Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED BETWEEN STA 427.668 AND 450.162 ON LT SIDE. THE BEAM WAS REPLACED IAW SRM 51-30-00.May 28, 1999 · N13066 · Doug DC1030SDR CALA9900624Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 450.162 IN CENTER AND ON RT SIDE. THE FLOORBEAM SECTIONS WERE REPLACED IAW SRM 51-30-00.May 28, 1999 · N13066 · Doug DC1030SDR CALA9900623Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 450.162 AND 515, LT SIDE. A NEW FLOORBEAM WAS INSTALLED IAW SRM 51-30-00.May 28, 1999 · N13066 · Doug DC1030SDR CALA9900620Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 449.250 ON RT SIDE. THE FLOORBEAM WAS REPLACED IAW SRM 51-30-00.May 28, 1999 · N13066 · Doug DC1030SDR UPS99229700Floorbeam · corrodedINSPECTION TYPE:SI, CORROSION ON FRAME BS 950, WL 207.5, LBL 55. REMOVED CORROSION AND TREATED AREA PER SRM 51-20-00.May 27, 1999 · N208UP · Boeing 727247SDR SWAA990934Floorbeam · crackedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CRACKED AT BS 500, RBL 14. REPAIRED BEAM PER SRM.May 27, 1999 · N306SW · Boeing 7373H4SDR UPS99229676Floorbeam · corrodedINSPECTION TYPE:SI CORROSION IN SEVERAL PLACES ON FLOORBEAM BS 344, RBL 20 TO LBL 55, WL 208. REMOVED AND REPLACED FLOORBEAM UPPER CHORD PER SRM 53-10-8.May 26, 1999 · N946UP · Boeing 72725CSDR SWAA990925Floorbeam · corrodedDURING SCHEDULED RON CHECK, FOUND CORROSION AT FLOORBEAM, BS 986.5, FROM CENTER TO RT END. REMOVED AND REPLACED FLOORBEAM SECTION PER SRM.May 26, 1999 · N675AA · Boeing 7373H4SDR USAA990477Floorbeam · corrodedTPA - DURING CX-6 CHECK, FOUND CORRODED ARM AT FLOORBEAM, APPROX 6 INCH AT STATION 1016, CENTER LINE OF AIRCRAFT CENTER WEB. CORROSION LEVEL 1. ACCOMPLISHED REPAIR PER EA 64270, FASTENERS WERE BACB30FP6 EXCEPT 13 EXISTING BACB30FP88, MATERIAL .050, 301.5 HARMay 25, 1999 · N270AU · Boeing 7372B7SDR RAAA99E4049Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND CORROSION AT TRANVERSE FLOORBEAM FS 863 RBL 50-58. REPAIRED AS PER SRM 53-2-4 M-54 NR 221.May 25, 1999 · N9744C · Lkheed 188CSDR CALA9900619Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED BETWEEN STA 1902 AND 2007, RT SIDE. THE FLOORBEAM WAS REPLACED IAW SRM 51-31-01.May 25, 1999 · N13066 · Doug DC1030SDR CALA9900618Floorbeam · corrodedINSPECTION FOUND CENTRAL FLOORBEAM (NR 2) CORRODED BETWEEN STA 1841 AND 1887. THE FLOORBEAM WAS REPLACED IAW SRM 51-31-01.May 25, 1999 · N13066 · Doug DC1030SDR CKSA9970Floorbeam · corrodedDURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND FLOORBEAM LOWER CHORD CORRODED APPROX 12INCHES AT ZONE 100, STA 709, RBL 68 TO RBL 80. FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 51-40-01. REPAIR CARRIED OUT IAW SRM 53-21-00, May 24, 1999 · N102CK · Lkheed 1011385115SDR CKSA99069Floorbeam · corrodedDURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND FLOORBEAM LOWER CHORD CORRODED STA 1443, C-2 CARGO COMPT. FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 53-21-00 FIG 802, INSTALLED AS PER SRM 51-40-01. REPAIR CARRIED OUT IAW SRM May 24, 1999 · N102CK · Lkheed 1011385115SDR CKSA99068Floorbeam · corrodedDURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND FLOORBEAM LOWER CHORD CORRODED AT ZONE 100, STA 689, RBL 60 TO RBL 77. FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 51-21-02. REPAIR CARRIED OUT IAW SRM 53-21-00, FLOORBEAM REPAIRMay 24, 1999 · N102CK · Lkheed 1011385115SDR CKSA99067Floorbeam · corrodedDURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND FLOORBEAM LOWER CHORD CORRODED APPROX 23 INCHES LONG AT ZONE 100, STA 789, LBL 34.5 TO LBL 46.5. FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 51-50-02. REPAIR CARRIED OUT IAW SRM May 24, 1999 · N102CK · Lkheed 1011385115SDR CKSA99064Floorbeam · corrodedDURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND FLOORBEAM LOWER CHORD CORRODED APPROX 2.5 INCHES LONG AT ZONE 100, STA 769, RBL 57 TO RBL 59. FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 51-40-01. REPAIR CARRIED OUT IAW SRM 53-May 24, 1999 · N102CK · Lkheed 1011385115SDR CKSA99063Doubler · corrodedDURING ROUTINE ACCOMPLISHMENT OF SCHEDULED C CHECK AND CPCP TASK CARDS, FOUND FLOORBEAM LOWER CHORD CORRODED APPROX 2.5 INCHES LONG AT ZONE 100, STA 729, RBL 70.5 TO RBL 73. FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 51-40-01. REPAIR CARRIED OUT IAW SRM 5May 24, 1999 · N102CK · Lkheed 1011385115SDR CALA9900617Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED AT RT SIDE BETWEEN STA 1905 AND 2007. THE FLOORBEAM WAS REPLACED IAW SRM 51-31-01.May 24, 1999 · N13066 · Doug DC1030SDR CALA9900616Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED ON LT AND RT SIDES AT STA 1821-1887. THE FLOORBEAM SECTIONS WERE REPLACED IAW SRM 51-30-00.May 24, 1999 · N13066 · Doug DC1030SDR RRXA991603Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, AFT CABIN RIGHT FLOOR PANEL SUPPORT BETWEEN STA 1766 AND STA 1745 RIGHT AT NUT PLATES BOTTOM SIDE BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRMay 23, 1999 · N604AL · Doug DC873FSDR USAA990461Floorbeam · corrodedCLT - DURING Q-2 CHECK, FOUND .250 INCH BY .250 INCH AREAS OF CORROSION ON FLOORBEAM AT BS 986.5 AT LBL 45.5-RBL 45.5. CORROSION LEVEL 2. INSTALLED NEW 'T' CAP PER TR 53-60-01. (M)May 22, 1999 · N419US · Boeing 737401
Back to JASC 5315