JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA990457Floorbeam · corrodedCLT - DURING Q-2 CHECK, FOUND 1 INCH BY 1 INCH CORRODED AREA ON FLOORBEAM AT BS 312 RBL 37, WL 208.1. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER PER SRM 53-10-51. (M)SDR GTIA9901016Floorbeam · mismanufacturedMHV - BS 996 FLOORBEAM UPPER CAP ANGLE FROM LBL 12 TO EOP AT LBL 52 REQUIRES NEW SECTION TO ACCOMMODATE LT AFT LAV FLOOR STRUCTURE MOD. C/W ENGINEERING DWG NR 53-99197-2. ALODINED AND PRIMED. (X)SDR AT9900413Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD CARGO COMPARTMENT FLOORBEAM TO CUSP LINE AT BS 351 CORRODED AROUND RIVETS, ASSOCIATED HARDWARE AND STAND OFFS. REMOVED CORROSION, FABRICATED REPAIR DOUBLER, DEBURRED, COUNTERSUNK, TREATED, PRIMEDSDR AT9900403Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE PASSENGER CABIN FLOORBEAM IN AFT LAVATORY AREA CHAFED AND CORRODED AT BS 980 BL 0-44L. FORMED NEW FLOORBEAM, LOCATED, DRILLED AND DEBURRED. FABRICATED REPAIR DOUBLER, ALODINED, PRIMED AND INSTALLED REPASDR ABXA9900503Floorbeam · corrodedFLOORBEAM CORRODED AT STATION 1320, LBL 24 TO RBL 24. REPAIRED IAW DC8 SRM 53-2-0.SDR RRXA991611Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CENTER FLOORBEAM AT AFT PRESSURE BULKHEAD FRAME ATTACHED FASTENERS LOOSE BOTH SIDES ATTACH ANGLE AND CORROSION EMANATING FROM FASTENERS AT STA 1766 AND LONGERON 36. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. RESDR DL76S991147Floorbeam · crackedDURING REPLACEMENT OF AN OVERHEAD CEILING PANEL IN THE AFT BAG BIN DAMAGE WAS FOUND ON THE BS 1329 FLOORBEAM AT LBL 11 AND RBL 11. REPAIRED PER ERA 333177-14, REV A.SDR CALA9900615Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED BETWEEN STA 859 AND 879, RT SIDE. THE BEAM WAS REPLACED IAW SRM 51-30-00.SDR CALA9900565Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 1110 FROM RBL 25-45. A REPAIR WAS INSTALLED IAW SRM 51-10-8, PAGE 18.SDR ASAA9910115Floorbeam · corrodedPDX - DURING C-CHECK, FOUND THE PASSENGER CABIN STUB FLOORBEAM CORRODED AROUND FASTENER HOLES ON TOP SIDE, BS 727, RBL 54.0. REPAIRED PER DWG 65-46547; SRM 53-10-1. (X)SDR ASAA9910112Floorbeam · corrodedPHX - DURING D-CHECK, FOUND THE MAIN CABIN FLOORBEAM CORRODED ON TOP AND BOTTOM SIDES OF FLANGE AT BS 727B, BL ZERO TO 56. REPAIRED PER SRM 51-40-3. (X)SDR 99FDEA00189Floorbeam · damagedNR 0166 - FWD CARGO LWR FLANGE OF FLOORBEAM DAMAGED BY TOO LONG FASTENERS. INSTALLED CTR SNAKE PIT PNL BS 680, LBL 24, RBL 24. INSTALLED FLOORBEAM LWR CHORD REPAIR PER SRM 53-10-8.SDR SIMA991381Floorbeam · elongationSAW - DURING CPCP-4 INSPECTION, FOUND FLOORBEAM 18 HAD AN ELONGATED HI-LOCK HOLE. REPAIRED FLOORBEAM 18 IAW SRM 53-00-00 FIGURE 429. AIRCRAFT RETURNED TO SERVICE. (M)SDR USAA990479Floorbeam · corrodedCLT - DURING C-4 CHECK, FOUND 2 INCH BY 1 INCH CORRODED AREA AT FLOORBEAM STATION 344 RBL 88, CORROSION LEVEL 1. REPLACED T-CAP PER SRM 53-00-51. (M)SDR USAA990473Floorbeam · corrodedCLT - DURING C-4 CHECK, FOUND 2 INCH CORRODED AREA OF FLOORBEAM AT STATION 287 RBL 79. CORROSION LEVEL 1. SPLICED SECTION T-CAP, INSTALLED REPAIR ANGLES EPR SRM 51-10. (M)SDR USAA990471Floorbeam · corrodedCLT - DURING C-4 CHECK, FOUND 2 INCH CORROSION ON FLOORBEAM AT STATION 303 RBL 53, CORROSION LEVEL 1. CUT SECTION OF T-CAP, INSTALLED NEW SECTION AND REPAIR ANGLES PER SRM 53-00-51. (M)SDR USAA990445Floorbeam · corrodedPIT - DURING Q-4 CHECK, FOUND 1 INCH BY 1 INCH CORRODED AREA AT STATION 965 FLOORBEAM RT LAV THRESHOLD ATTACH POINT. CORROSION LEVEL 1, CORROSION TASK NR C58-53300. SPLICED IN NEW SECTION OF ANGLE PER TYPICAL REPAIR 53-10-14. (M)SDR COMA9960215Floor Beam · corrodedFLOOR BEAMS LBL 27, LBL 9, RBL 9, AND RBL 27 FROM BS 280 TO BS 409 HAVE CORROSION DAMAGE. REPLACED DAMAGED SECTIONS OF FLOOR BEAMS. PART TC: 13,942. (X)SDR AT9900390Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO, FL, FOUND PASSENGER CABIN FLOORBEAM RIGHT SIDE AFT LAVATORY AT BS 996 RBL 17-54R CORRODED. REMOVED UPPER CAP, LOCATED, DRILLED, AND INSTALLED UPPER CAP IAW DC9 SRM 53-11-3 FIG 11, 51-30-5, 51-10-4, AND 51-10-2.SDR UPS99229702Floorbeam · corrodedINSPECTION TYPE:SI, CORROSION (C53-224-01.05-01) ON BS 380 FLOORBEAM LBL 55 TO LBL 46 WL 208. CUT OUT DAMAGED FLOORBEAM, FABRICATED REPAIR PARTS AND INSTALLED REPAIR PARTS IAW SRM 53-10-8.SDR SWAA990864Floorbeam · corrodedDURING SCHEDULED D CHECK, FOUND CORROSION ON FLOORBEAM, BS 328, RBL 37 INSIDE CABIN. REPAIRED BEAM PER SRM.SDR CALA9900545Floorbeam · chafedCABIN FS 408 FLOORBEAM UPPER FLANGE IS CHAFED BETWEEN RBL 12 AND LBL 12. FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 53-30, 53-05, 51-10-4, AND 51-30-5.SDR CALA9900544Floorbeam · corrodedAFT CARGO PIT UPPER SIDE OF FLOORBEAM LBL 22 STA 980 IS CORRODED. FABRICATED AND INSTALLED REPAIR PER SRM 51-10-3, 53-10 FIG 10, 53-05 FIG 20A, 51-10-4, AND 51-30-5.SDR CALA9900543Floorbeam · chafedCABIN FS 465 FLOORBEAM UPPER FLANGE IS CHFED BETWEEN RBL 12 AND LDL 12. BLENDED FLOOR BEAM UPPER FLANGE. DIMENSIONS OUT OF LIMITS. REPAIRED FLOORBEAM SUPPORT PER EAC 531155-01055.SDR AT9900376Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND PASSENGER CABIN FLOORBEAM CHAFED AND CORRODED AT BS 965 BL-30L. FORMED, FIT, TRIMMED, DRILLED AND INSTALLED REPAIR ANGLE IAW DC9 SRM 53-05 FIG 20A.SDR USAA990434Floorbeam · crackedCLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 520 LBL 46 FLOORBEAM. FABRICATED REPAIRED PER EA 64448 AND S/B 737-53-1120. (M)SDR SWAA990866Floobeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION ON UPPER CHORD OF FLOORBEAM, BS 986, LBL41-RBL33. REPAIRED BEAM PER SRM, AND SWA RA NR 1-353-2079.SDR RAAA99E4048Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND CORROSION ON TRANSVERSE FLOORBEAM AND BETWEEN REPAIR ANGLE AND TOP FLANGE AT FS 844 LBL 60 AT AFT PAX DOOR SILL. REPAIRED PER SRM 53-2-4 AND 51-2-12, M-54 NR 176.SDR RAAA99E4045Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND CORROSION ON TRANSVERSE FLOORBEAM FS 882 BBL 0-LBL 20. REPAIRED AS PER SRM 53-2-4, M-54 NR 169.SDR UF6A990540Floorbeam · corrodedSBN - FLOORBEAM AT STATION 270AS HAS CORROSION IN THREE AREAS ACROSS BEAM. CONCERNED AREAS ARE BY THE AFT BAGGAGE DOOR, IN THE CENTER, AND BY THE AFT PASSENGER DOOR. MAINTENANCE REMOVED CORROSION BY MECHANICAL METHOD. AREA WAS ALODINED, PRIMED. STRAP WAS FSDR UF6A990536Floorbeam · corrodedSBN - FLOORBEAM AT STATION 324FS HAS CORROSION. MAINTENANCE CLEANED CORROSION AND SMOOTHERD SHARP EDGES. AREA WAS ALODINED, PRIMED AND FINISHED PER FACTORY SPECIFICATIONS. ALL WORK WAS DONE IAW ENGINEERING ORDER NR 99-091. (M)SDR UF6A990535Floorbeam · corrodedSBN - FLOORBEAM AT STATION 343FS HAS CORROSION. MAINTENANCE CUT OUT DAMAGED AREA AND FABRICATED AND ANGLE FROM 2024-T3, .050 THICK BY 19.75 INCHES LONG BY 1 INCH WIDE. ANGLE WAS SPLICED INTO FLOORBEAM BY FABRICATING A STRAP FROM 2024-T3, .050 INCHES THICK. SDR SIMA991311Floorbeam · corrodedSAW - DURING CPCP-1 INSPECTION, FOUND FLOORBEAM 40 CORRODED. REMOVED AND REPLACED FLOORBEAM 40 IAW 53-61-40. AIRCRAFT RETURNED TO SERVICE. (M)SDR RAAA99E4038Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND CORROSION ON TRANSVERES FLOORBEAM AT FS 844, BL 0 TO LBL 54. REPAIRED FLOORBEAM AS PER SRM 53-2-4 M54 NR 155.SDR CALA9900526Floorbeam · gougedCABIN FS 313 FLOORBEAM UPPER FLANGE IS GOUGED BETWEEN RBL 12A AND LBL 12A. AFTER BLEND OUT OF GOUGED, FOUND OUT OF LIMITS. FABRICATED TREATED, PRIMED AND INSTALLED REPAIR ANGLE AND FILLERS PER SRM 53-05 FIG 20A, 53-01-01, 53-10-4 AND 53-05 FIG 20.SDR C2XA99IA271Floorbeam · corrodedIAH - DURING C-CHECK INSPECTION, THE FLOORBEAM AT FRAME 39 WAS FOUND TO BE CORRODED. MAINTENANCE REPAIRED THE AFFECTED FLOORBEAM IAW CONTINENTAL EXPRESS ENGINEERING CHANGE AND REPAIR AUTHORIZATION EC5310-01037, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVSDR C2XA99IA270Floorbeam · corrodedIAH - DURING C-CHECK INSPECTION, THE FLOORBEAM AT FRAME 36 WAS FOUND TO BE CORRODED. MAINTENANCE REPAIRED THE AFFECTED FLOORBEAM IAW CONTINENTAL EXPRESS ENGINEERING CHANGE AND REPAIR AUTHORIZATION EC5310-01037, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVSDR UPS99229551Floorbeam · corrodedINSPECTION TYPE:SI, CORROSION ON STRAP ON FLOORBEAM UPPER CHORD LOWER SIDE BS 312, BL 0, WL 208. REPAIR TO BE ACCOMPLISHED ON CUSTOMER ID 888989.SDR SIMA991301Floorbeam · corrodedSAW - DURING CPCP-1 INSPECTION, FOUND FLOORBEAM 38 AND 39 CORRODED. MAINTENANCE REPAIRED THE FLOORBEAMS IAW SRM 53-00-00 FIGURE 438 AND 53-61-40 FIGURE 412. AIRCRAFT RETURNED TO SERVICE. (M)SDR RAAA99E4029Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND TRANSVERSE FLOORBEAM WITH CORROSION AND HOLE DAMAGE, FS 502, LBL 22-26. REPAIRED AS PER SRM 53-2-4, M-54 NR 134.SDR CALA9900518Floorbeam · corrodedFLOORBEAM FS 312 HAS 2 HOLES WITH CORROSION AT LBL 20 AND 3. CUT OUT DAMAGED AREA, FABRICATED, TREATED, PRIMED AND INSTALLED REPAIR PER SRM 53-10-9 FIG 8.SDR CALA9900506Floorbeam · corrodedFLOORBEAM FS 344 HAS CORROSION TOP FLANGE BOTH SIDES RBL 24 TO LBL 60. REPAIRED AREA PER SRM 53-40-8 PAGE 51.SDR AT9900371Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO, FL. FOUND THE CABIN FLOORBEAM UPPER FLANGE CORRODED AT BS 196 BL 0. REMOVED FLOORBEAM, CUT, DRILLED, DEBURRED, ALODINED, PRIMED AND INSTALLED NEW FLOORBEAM IAW DC9 SRM 53-01 FIG 1 SHEET 3, 51-30-2, 51-10-3, 53-13-1 AND 53-10-4.SDR USAA990464Floorbeam · corrodedCLT - DURING C-4 CHECK, FOUND 2 INCH CORROSION ALONG UPPER SURFACE FLOORBEAM AT STATION 1640. CORROSION TASK NR C53-252-03, C53-251-03, CORROSION LEVEL 2. INSTALLED NEW T-CAP ON FLOORBEAM PER 757-200 TR 53-15-01. (M)SDR USAA990454Floorbeam · corrodedCLT - DURING C-4 CHECK, FOUND CORROSION AROUND NUT PLATE .5 INCH BY .5 INCH AT STATION 1660, RBL 26, SURFACE CORROSION ON TOP OF FLOORBEAM, CORROSION LEVEL 2. CUT OUT 2 INCH BY 2.5 INCH AREA OF FLOORBEAM TOP, TWO DOUBLER ANGLES AND A FILLER PER SRM 53-00-51,SDR RAAA99E4015Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND TRANSVERSE FLOORBEAM CORRODED AT FS 445 FROM LBL 27 TO LBL 55 ON TOP FLANGE. REPAIRED PER SRM 53-2-4, M-54.SDR RAAA99E4014Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND TRANSVERSE FLOORBEAM CORRODED AT FS 571 LBL 26 TO LBL 45 TOP FLANGE. REPLACED FLOORBEAM PER SRM 51-2-9. INSTALLED PER SRM 51-2-12 M-54.SDR RAAA99E4013Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND TRANVERSE FLOORBEAM CORRODED AT FS 540 LBL 27 TO LBL 55 TOP FLANGE. REPLACED FLOORBEAM PER SRM 51-2-9. INSTALLED FLOORBEAM PER SRM 51-2-12 M-54.SDR RAAA99E4012Floorbeam · corrodedDURING SCHEDULED NR 1 CHECK, FOUND TRANSVERSE FLOORBEAM CORRODED AT FS 521 LBL 28 TO LBL 55 TOP FLANGE. REPLACED FLOORBEAM AS PER SRM 51-2-9. INSTALLED AS PER SRM 51-2-12 M-54.SDR CALA9900493Floorbeam · corrodedFLOOR SUPPORT (CABIN) HAS CORROSION AT STA 951 RBL 47. REPLACED PER EC/RA 5310-03585.
Back to JASC 5315