JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA960574Floor Beam · corrodedPAE - FLT 7834 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION AT BS 1016 ON FLOOR BEAM LBL 11 UPPER SURFACE WL 208. REPAIRED IAW, TCO-PAN-96-1353-RR18110-3 AND EO 2-53-16-43. (M)SDR AWXA960566Floor Beam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION 947 FLOOR BEAM TOP FLANGE, WL 208, RBL 4 AND LBL 4, BOTH TOP AND BOTTOM. FABRICATED, ALODINED AND INSTALLED REPAIR PARTS PER SRM 53-10-9. (M)SDR AWXA960565Floor Beam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION IN FLOOR BEAM STATION 967, RBL 15-36, WL 208. REMOVED AND REPLACED DAMAGED SECTION OF FLOOR BEAM BS 967-LBL2-RBL57, SRM 53-10-9. (M)SDR ABXA9700467Floorbeam · damagedDURING C-CHECK, THE AFT FLANGE OF THE FLOORBEAM AT STA 917 WAS FOUND TO BE GOUGED AND WORN. REPAIRED IAW REA D953-16470-MR.SDR AWXA960618Floor Beam · corrodedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 377, RBL 2, WL 208. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PARTS PER SRM 53-00-51 AND 51-20-01. (M)SDR AWXA960616Floor Beam · corrodedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR BEAM AT STATION 324 HAS CORROSION AT RBL 51 TO RBL 65, WL 208. FABRICATED, ALODINED, PRIMED AND INSTALLED PARTS PER ER 5-23-12-06 AND TCO PAN 96-1358RR-8110-3. (M)SDR 9621585517Floor Beam · corrodedDURING P-CHECK, FOUND CORROSION IN THE BS 365 FLOOR BEAM UPPER CHORD FROM RBL 45 TO 56. REPAIRED CHORD (P/N 141N5112) PER EA 55-110352.SDR DHL9672218CFloor Beam · corrodedAT C-CHECK, FOUND HEAVY CORROSION ON TOP FLOOR BEAM CHORD AT STA 400 RBL 4 AND LBL 4. INSTALLED FLOOR BEAM REPAIR AT UPPER CHORD, PER SRM 53-10-8 FROM RBL 4 TO LBL 4.SDR SCNA96306Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 1887, LBL 30 AND RBL 24. REMOVED CORRODED SECTIONS, FABRICATED AND INSTALLED FILLERS AND DOUBLERS IN ACCORDANCE WITH SRM 51-21-00, SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC10-53-014.SDR 9621576613Floor Beam · corrodedDURING P-CHECK, FOUND CORROSION ON THE BS 520 UPPER DECK FLOOR BEAM UPPER CHORD FROM LBL 40 TO 50. REPAIRED CHORD (P/N 65B10936-12) PER EA 66-106402.SDR AWXA960567Floor Beam · corrodedPAE - FLT 7824 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON UPPER SURFACE OF 986 FLOOR BEAM AT RBL 5 AND LBL 3, WL 208. CUT OUT DAMAGED PORTION OF UPPER FLOOR BEAM CHORD. REMOVED 2.5 INCH BY 1 INCH AND INSTALLED REPAIR ANGLES AND FILLER AT BS 986, SDR 96FDEA01558Floor Beam · corrodedFORWARD CABIN FLOOR BEAM STA 344 HAS CORROSION BOTH TOP AND BOTTOM OF TOP FLANGE AT NUTPLATE HOLES LBL 30 - RBL 15 (MARKED TOP AND BOTTOM). REMOVED CORROSION PER MM 51-10-6. OUT OF LIMITS AT LBL 4, 12, AND 22 PER 53-10-8 FIG 9. INSTALLED SPLICE ANGLES SDR SCNA96304Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 735 TO BS 737 RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC1SDR SCNA96303Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 775 TO 830, RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC10-53SDR SCNA96305Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 750 RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC10-53-13.SDR SCNA96302Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 685 IN THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01.SDR SCNA96301Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 823 IN THE FORWARD GALLEY. REMOVED CORROSION, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01.SDR SCNA96276Floorbeam · crackedDURING HEAVY MAINTENANCE, FOUND FLOORBEAM CRACKED AT BS 735 IN THE LOWER GALLEY AREA. CUT OUT MATERIAL, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 53-00-01 AND 53-13-01.SDR SCNA96300Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM BELOW THE THRESHOLD ON THE FORWARD SIDE OF THE SERVICE ELEVATOR IN THE LOWER GALLEY. REMOVED CORRODED SECTION OF FLOORBEAM, FABRICATED AND INSTALLED A NEW SECTION OF FLOORBEAM IN ACCORDANCE WITH SRM SDR DHL9672219CFloor Beam · corrodedAT C-CHECK, CABIN FLOOR BEAM HAS CORROSION AT BOTTOM OF UPPER FLANGE BS 1030 RBL 22. CUT OUT DAMAGED SECTION, INSTALLED FLOOR BEAM REPAIR FROM RBL 9 TO RBL 34 PER SRM 53-10-8.SDR DHL9672214CFloor Beam · corrodedAT C-CHECK, CORROSION ON CABIN FLOOR SUPPORT BEAM STA 480 RBL 0 TO RBL 16. CUT OUT DAMAGED AREA, INSTALLED FLOOR BEAM REPAIR PER SRM 53-10-8, T-ANGLE 34 INCHES LONG.SDR AALA961406Floor Beam · corrodedAFW - AFTER REMOVING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-942. (M)SDR AALA961403Floor Beam · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-944. (M)SDR AALA961398Floor Beam · corrodedAFW - FOUND SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS ON FLOOR BEAM AT STATION 1640. PER MRB 757-954. (M)SDR 96FDEA01587Floorbeam · corrodedCORROSION (C53-111-01, -3) IN AFT CARGO BAY AT BS 1050 LBL 20 TO RBL 20 WL 199 ON FLOORBEAM AT NUTPLATES HOLES. REMOVED CORRODED SECTION OF BS 1050 FLOORBEAM FROM LBL 25 TO RBL 25 WL 199 LOWER FLANGE. REPAIRED LOWER FLANGE PER FEDEX SRM 53-10-8 FIG 3 EA NR 7SDR 96FDEA01562Floorbeam · corrodedNR0435 AND 014, CORROSION (C53-224-01, -3, C53-224-04) STR 9L STA 1130 RBL 25 TO 45 WL 208 UPPER FLANGE. *S/D* FOUND CORROSION TO BE OUT OF LIMITS. REPAIRED FLOORBEAM UPPER FLANGE BS 1130, RBL 25 TO 45 WL 208 IAW FEDEX EA 7-5310-31186.SDR 96FDEA01561Floorbeam · corrodedNR0439 AND 013, CORROSION (C53-111-01, -3) IN THE AFT CARGO BAY AT BS 1110 LBL 16 TO 30 WL 199 ON FLOORBEAM AT NUTPLATE HOLES. *S/D* CORROSION FOUND TO BE OUT OF LIMITS. REMOVED CORRODED SECTION AND REPAIRED LOWER FLANGE IAW FEDEX EA 7-5310-31192.SDR SWAA960995Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOBEAM CORROSION AROUND CLIP NUT HOLES AT BS 344 LBL 7, 10, 12 AND BL 0, ON FWD AND AFT FLANGES. REPLACED T-CAP PER BOEING SRM.SDR AWXA960534Floor Beam · corrodedPAE - FLT 7806 - DURING ROUTINE SCHEDULED C-10 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AROUND FLOOR HOLES LBL 21 AND LBL 28, STATION 344, WL 208. REPAIRED FLOOR BEAM STATION 344, LB 21 - 31.5, WL 208 PER SRM 53-10-51. (M)SDR AALA961367Floor Beam · corrodedTUL - FOUND CORROSION ON TOP OF FLOOR BEAM STATION 1130 BETWEEN RIGHT, INBOARD AND OUTBOARD SEAT TRACK. REMOVED CORROSION PER SRM 51-10-6, REPAIRED FLOOR BEAM PER AARD/MS/MB CHAPTER 53-10-07-1 PAGE 1-3. (M)SDR 9621191152Floor Beam · crackedDURING T-CHECK, FOUND A CRACK IN THE FORWARD CARGO FLOOR BEAM AT FS 1099, LBL 58. REPAIRED BEAM (P/N ADA 0039-5) PER EA 11-110248.SDR USAA960622Floor Beam · corrosionINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND APPROXIMATELY 2 INCH BY 20 INCH AREA OF HEAVY SURFACE CORROSION FLOOR BEAM STATION 360, RBL 12 TO RBL 56. INSTALLED REPAIR ANGLES, REPAIRED PER TR 53-10-05 C. CORROSION TASK NR C53-107-01, CORROSION LEVEL 1. (SDR USAA960617Floor Beam · corrosionINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH AND 1.5 INCH BY 6 INCH CORRODED AREAS FLOOR BEAM BS 328 LBL 10 AND LBL 24-30. REPAIR ANGLES AND T-CAP. REPAIRED PER TR 53-10-13. CORROSION TASK NR C53-107-01, CORROSION LEVEL 1. (M)SDR USAA960616Floor Beam · corrodedINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORRODED AREA 1 INCH BY 68 INCH FLOOR BEAM BS 986 LBL 18 INCH TO RBL 50 INCH. INSTALLED T-CAP REPAIR AND REPAIRED PER TR 53-10-05C. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)SDR USAA960614Floor Beam · corrosionINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 55 INCH CORRODED AREA FLOOR BEAM BS 947 BL 30 INCH - RBL 25 INCH. INSTALLED T-CAP REPAIR, REPAIRED TR 53-10-05 C AND SPM. CORROSION TASK NR C53-107-02, CORROSION LEVLE 1. (M)SDR UPS96821377Floorbeam · corrosionINSPECTION TYPE-CS2, HEAVY EXFOLIATED CORROSION AT CABIN FLOORBEAM FS 680 UPPER FLANGE RBL 60. REPAIRED PER UPS EO.SDR SWAA960986Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 344, LBL 29, 33, 35, 49 AND 43. REPLACED T-CAPS PER BOEING SRM.SDR SWAA960985Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 294, BS 0, RBL 26.5 AND RBL 8. REPLACED T-CAPS PER BOEING SRM.SDR SWAA960984Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 344, LBL 18 AND 14. REPLACED T-CAPS PER BOEING SRM.SDR CALA9601451Floor Beam · corrodedAFT CARGO COMPARTMENT STATION 1130 BLU TO RBL 60 FLOORBEAM LOWER CAP HAS HEAVY CORROSION. REMOVED LOWER CAP, FABRICATED REPAIR TREATED, PRIMED, THEN INSTALLED IAW DWG 25770-5065 AND EC/RA 5310-03334.SDR CALA9601368Floorbeam · crackedINSPECTION FOUND A 1 INCH CRACK IN MAIN CABIN FLOORBEAM AT STA 724, BL 0. THE WEB AND STIFFENER WERE REMOVED IAW SRM 51-30-2. A WEB AND DOUBLER WERE FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-20-4, 57-30-2, ECRA 5710-01755 AND REO 02209.SDR CALA9601366Floorbeam · crackedINSPECTION FOUND A 1.5 INCH CRACK IN FLOORBEAM AT STA 684, LBL 24.8. THE FLOORBEAM WAS REPAIRED IAW EA 5710-01638 AND SRM 51-40-4.SDR CALA9601360Floorbeam · crackedINSPECTION FOUND A 2 INCH CRACK IN FLOORBEAM AT STA 684, RBL 24.8. THE FLOORBEAM WAS REPAIRED IAW EA 5710-01638 AND SRM 51-40-4.SDR CALA9601356Floorbeam · corrodedINSPECTION FOUND FLOORBEAM AND SUPPORT CORRODED AT AFT CABIN L-2 DOOR THRESHOLD, STA 986. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-9, 51-10-2 AND 51-30-2.SDR CALA9601352Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED BETWEEN SEAT TRACK ROW D AND CUSP LINE AT STA 360. A NEW FLOORBEAM WAS FABRICATED AND INSTALLED IAW SRM 53-10-9, 51-10-2 AND 51-30-3.SDR 96FDEA01513Floorbeam · corrodedNR0250 AND 001, CORROSION (C53-111-01-2) ON FLOORBEAM LOWER FLANGE AROUND NUTPLATE HOLE AT BS 520 WL 200 RBL 4. *S/D* CORROSION FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR ANGLES AND REPAIR FILLER PER FEDEX SRM 53-10-8 ONSDR UPS96821372Floorbeam · corrosionINSPECTION TYPE-CS2, FS 12 LBL 40 TO 60 FLOORBEAM LOWER FLANGE HAS EXFOLIATED CORROSION. REPAIRED PER UPS EO.SDR SWAA960980Floorbeam · crackedDURING SCHEDULED C1 CHECK, FOUND FLOORBEAM T-CAP AT BS 312 CRACKED ABOVE FWD UPPER AIRSTAIR DOOR STOP AT LWR RADIUS. REPAIRED PER BOEING SRM.SDR DHL9672220CFloor Beam · corrodedAT C-CHECK, FOUND CABIN FLOOR BEAM CORRODED AT BS 380 RBL 23. CUT OUT DAMAGED AREA, APPROX 19, INSTALLED REPAIR 24 BY 2.5 PER SRM 53-10-8.SDR UPS96821366Floorbeam · corrosionINSPECTION TYPE-CS2, FS 1730, FLOORBEAM HAS MODERATE CORROSION DAMAGE FROM BL 0 TO LBL 60. REPLACED FLOORBEAM SECTION PER SRM 51-1-20D.
Back to JASC 5315