JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA960333Floor Beam · corrodedPAE - FLT 7827 - DURING ROUTINE SCHEDULED C-12 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM UPPER CHORD AT BS 312, WL 208, LBL 16. REPAIRED FLOOR BEAM AT BS 312, WL 208, LBL 16 - RBL 60 BY REPLACING UPPER TEE CHORD IAW SRM 53-10-51. AIRCRAFT TOTAL TIME, SDR AWXA960332Floor Beam · corrodedPAE - FLT 7827 - DURING ROUTINE SCHEDULED C-12 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM UPPER CHORD AT BS 294, WL 208, RBL 33. REMOVED FLOOR BEAM BS 294, RBL 25-60, WL 208. FABRICATED AND INSTALLED REPAIR PARTS PER SRM 52-10-51. AIRCRAFT TOTAL TIME: SDR ASAA9610075Floor Beam · corrodedSEA - DURING C-CHECK, FOUND CORROSION ON THE UPPER CHORD FLANGE OF THE FLOOR BEAM AT BS 520, LBL 20 TO RBL 20. REPAIRED PER EA 5310-01445 AND BOEING TELEX ASA-SEA-95-0249RR. (M)SDR SWAA960561Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED AT BS 344, LBL 50 TO RBL 8. REPAIRED PER BOEING SRM.SDR AU960922Floorbeam · corroded(AUS) LEVEL 2 CORROSION ON LOWER `T' OF FLOORBEAM AT FUSELAGE STN 937.SDR UPS96220475Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR BEAM STA 344, WL 208 HAS NUMEROUS AREAS OF CORROSION FROM LBL 60 TO RBL 20. REMOVED AND REPLACED UPPER CHORD OF FLOOR BEAM IAW SRM 53-10-08.SDR 96FDEA01146Floor Beam · corrodedNR0440 AND 044, CORROSION (C53-111-01) ON LOWER FLOOR BEAM FLANGE AT BS 1130 RBL 29, 36 LBL 8 AND 20 WL 200. *S/D* REMOVED CORROSION FROM LOWER FLOOR BEAM FLANGE AT BS 1130 RBL 29, 36 LBL 8 AND 20 WL 200. REPAIRED IAW FEDEX SRM 53-10-08 FIG 8 AND EX EA 7-53SDR DHL9672115CFloorbeam · corrodedAT C-CHECK, FOUND CABIN FLOORBEAM BS 312 LBL 4 CORRODED. CUT OUT DAMAGED AREA AND INSTALLED REPAIR 9.75 BY 1.5 BY 1.5 PER SRM 51-40-4.SDR COMA9610216Floor Beam · corrodedDURING 2C INSPECTION, THE FLOOR BEAM NEXT TO THE ELEVATOR CONTROL COLUMN LEFT WAS FOUND WITH SURFACE CORROSION. CLEANED, TREATED AND PAINTED AREA PER M/M 51-21-04.SDR COMA9610215Floor Beam · corrodedDURING 2C INSPECTION, THE FLOOR BEAM NEXT TO THE ELEVATOR CONTROL COLUMN RIGHT WAS FOUND WITH SURFACE CORROSION. CLEANED, TREATED AND PAINTED AREA PER M/M 51-21-04.SDR COMA9610205Floor Beam · corrodedDURING 2C INSPECTION, FOUND SURFACE CORROSION ON FLOOR BEAM THAT GALLEY FLOOR ATTACHMENT TRACK MOUNTS TO. REMOVED SURFACE CORROSION TREATED AREA AND PAINTED TO SERVICEABLE CONDITION.SDR CALA9600838Floor Beam · corrodedINSPECTION FOUND FLOOR BEAM CORRODED AT CEILING OF AFT CARGO COMPARTMENT, STA 1130 AND 1148, RT SIDE OF AIRCRAFT. THE FLOOR BEAM WAS REPAIRED IAW ECRA 5310-03288.SDR USAA960474Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION ON TOP OF FLOORBEAM LOCATED AT STATION 986.5 RBL 12 AND RBL 14. INSTALLED NEW CHORD AND REPAIR ANGLES AS PER T/R 53-10-05. (M)SDR USAA960473Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION AT NUT PLATE HOLES, ACROSS FLOORBEAM LOCATED AT STATION 986.5. INSTALLED NEW CHORD AND REPAIR ANGLES AS PER T/R 53-10-05. (M)SDR USAA960472Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION, AT NUT PLATE HOLES ACROSS FLOORBEAM, LOCATED AT STATION 967. INSTALLED NEW CHORD AND REPAIR ANGLES PER T/R 53-15-91A. (M)SDR MWEA96170Floor Beam · corrodedDURING CERT INSP, FOUND CABIN CENTER FLOOR BEAM UPPER CHANNEL WITH MODERATE CORROSION FROM STA 917 TO 965. REPLACED THE SECTION OF FLOOR BEAM IAW SRM 53-01, PG 1 AND 53-11-3, FIG 11.SDR MWEA96167Floor Beam · chafedDURING CERT INSP, A CABIN FLOOR BEAM WAS FOUND CHAFED AT STA 541 UNDER LT CENTER FLOORBOARD. REPAIRED THE FLOOR BEAM IAW SRM 53-05, FIG 20.SDR MWEA96166Floor Beam · chafedDURING CERT INSP, A CABIN FLOOR BEAM WAS FOUND CHAFED AT STA 229 UNDER THE LT CENTER FLOOR BOARD. REPAIRED THE FLOOR BEAM IAW 53-05, FIG 20.SDR AWXA960286Floor Beam · corrodedPAE - FLT 7807 - DURING ROUTINE SCHEDULED C-7 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT STA 967, WL 208. REMOVED CORRODED FLOOR BEAM AND REPAIRED BEAM PER SRM 53-00-51, BS 767, LBL 1.5 - LBL 56. (X)SDR ARWA9606059Floor Beam · corrodedSUPPORT ANGLE AT FLOOR BEAM HAS LEVEL 2 CORROSION AT FS 1723. REMOVED ANGLE, FABRICATED, TREATED AND INSTALLED ANGLE IAW DC-8 SRM 53-7-3, 51-1-4, 51-1-8 AND 51-1-21.SDR 96FDEA01130Floor Beam · corrodedNR0476 AND 033, CORROSION (53-111-01, -2) ON FLOOR BEAM STA 560 LBL 18 WL 198, FWD CARGO BAY.SDR UPS96220565Floor Beam · crackedINSPECTION TYPE-C, CRACK FOUND ON FLOOR BEAM UPPER FLANGE AT BS 870 AT ATTACH POINT TO BS 870 FITTING RT SIDE. REPAIRED IAW SRS EO 96-27-012.SDR DHL9672152CFloorbeam · corrodedAT C-CHECK, FOUND CABIN FLOORBEAM CAP CORRODED ALONG TOP SURFACE AND AT NUT CLIP LOCATION BS 344 LBL 60 TO RBL 14. REPLACED CAP PER SRM 51-40-4.SDR DHL9672114CFloorbeam · corrodedAT C-CHECK, FOUND CABIN FLOORBEAM AT BS 312 LBL 30 CORRODED AT FLOORBEAM ATTACH POINTS. CUT OUT DAMAGED AREAS AND INSTALLED ANGLE REPAIR 5 BY 7 PER SRM 53-10-8.SDR C2XA96IA150Floor Beam · corrodedIAH - DURING C-CHECK INSPECTION, THE FLOOR SUPPORT BEAM AT FRAME 36 WAS FOUND TO BE CORRODED. MX REMOVED AND REPLACED THE FLOOR BEAM AND THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR AWXA960287Floor Beam · corrodedPAE - FLT 7807 - DURING ROUTINE SCHEDULED C-7 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM STA 987, WL 208, LBL ZERO, 20, 46, AND RBL 22. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIRED PARTS PER E.R. 3-53-15-07. (X)SDR ABXA9700218Floorbeam · damagedDURING ACCEPTANCE INSPECTION, THE FLOORBEAM AT STATION 200 WAS FOUND TO HAVE SEVERAL DOUBLE DRILLED AND CLOSELY SPACED HOLES. THE FLOORBEAM WAS REPAIRED IAW REA D953-15436-MR.SDR ABXA9700095Floorbeam · damagedDURING ACCEPTANCE INSPECTION, THE FLOORBEAM AT STATION 237 WAS FOUND TO HAVE TWO GOUGES IN THE UPPER FOWARD FLANGE AT LBL 6. THE FLOORBEAM WAS REPAIRED IAW REA D953-15500-MR.SDR ABXA9700093Floorbeam · damagedDURING ACCEPTANCE INSPECTION, THE FLOORBEAM AT STATION 160 WAS FOUND TO HAVE SEVERAL DOUBLE DRILLED AND CLOSELY SPACED HOLES. THE FLOORBEAM WAS REPAIRED IAW REA D953-15436-MR.SDR AWXA960288Floor Beam · corrodedPAE - FLT 7807 - DURING ROUTINE SCHEDULED C-7 MAINTENANCE CHECK, FOUND CORROSION ON TOP CHORD OF FLOOR BEAM BS 294.5, RLB 28 - RBL 35, WL 208. REMOVED CORRODED SECTION OF FLOOR BEAM, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-10-51. (X)SDR AWXA960275Floor Beam · corrodedPAE - FLT 7829 - DURING ROUTINE SCHEDULED C-13 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM STA 987, LBL 28 - RBL 26, WL 208. REMOVED, FABRICATED, INSTALLED REPAIR PARTS PER SRM 53-60-51. (X)SDR AALA960901Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-860. (M)SDR AALA960900Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 324 HAS CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-861. (M)SDR AALA960899Floor Beam · corrodedAFW - FOUND FLOOR BEAM AT STATION 365 RBL 61 HAD CORROSION BLENDED BEYOND SRM LIMITS. PER MRB 757-856. (M)SDR AALA960898Floor Beam · gougedAFW - FOUND FLOOR BEAM AT STATION 1600 LBL 13 HAD A GOUGE BLENDED BEYOND SRM LIMITS. PER MRB 757-857. (M)SDR UPS96220450Floorbeam · corrodedINSPECTION TYPE SI, CORROSION ON FLOORBEAM STA 420 WL 206 IN NUTCLIP HOLES LBL 46 TO 60, LBL 24, RBL 24 AREAS MARKED. FOUND CORROSION OUT OF LIMITS FOR SRM 53-10-1, FABRICATED REPAIR PARTS PER SRM 53-10-8 AND INSTALLED REPAIR PARTS PER SRM 53-10-8.SDR UPS96220448Floorbeam · corrodedINSPECTION TYPE SI, CORROSION ON FLOORBEAM AT STA 328, WL 208, LBL 35, 31. CUT OUT DAMAGED AREA AND REPAIRED IAW SRM 53-10-8.SDR 96ZZZM1161Floor Beam · corrodedFOUND LEVEL 2 CORROSION, MAIN CABIN FLOOR BEAM UPPER CAP IS CORRODED AT FS 329 TO LBL 64. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 51-10-05.SDR 96ZZZM1159Floor Beam · corrodedFOUND LEVEL 2 CORROSION, FLOOR BEAM STATION 1778 FROM BL 82 LEFT AND RIGHT CORRODED. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-21-00. (M)SDR 96ZZZM1152Floor Beam · corrodedFOUND LEVEL 2 CORROSION, FORWARD CARGO COMPARTMENT, LEFT FLOOR BEAM HAS CORROSION, AND CRACKED AT STATION 695. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-21-00.SDR 96FDEA01100Floor Beam · gougedNR0481 AND 014, FOUND GOUGE IN FLOOR BEAM STA 560 RBL 6 WL 198, FWD BAY. *S/D* REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-8.SDR 96FDEA01099Floor Beam · corrodedNR0477 AND 011, CORROSION (C53-111-01, -2) ON FLOOR BEAM STA 600 RBL 2, 8, 13, 15, 18 WL 198, FWD BAY. *S/D* BLENDED AND INSTALLED REPAIR STRAP IAW FED SRM 53-10-1 AND 53-10-8.SDR 96FDEA01092Floor Beam · corrodedNR0352 AND 004, CORROSION (C53-224-01) ON FLOOR BEAM TOP CHORD BS 600 RBL 10 TO 47 WL 208. *S/D* REMOVED CORROSION ON FLOOR BEAM TOP CHORD BS 600 RBL 10 TO 47 WL 208. FOUND AREA AT RBL 10 TO 17 TO BE OUT OF LIMITS. REPAIRED FLOOR BEAM IAW SRM 53-10-08.SDR 96FDEA01080Floor Beam · double holeNR 0514, 012 DOUBLE HOLE IN FLOOR BEAM TOP CHORD BS 1110, LBL 32, WL 208. *S/D* TRIMMED OUT DOUBLE HOLE IN FLOOR BEAM TO CHORD BS 1110 LB 32 WL 208. FABRICATED REPAIR ANGLES AND FILLER, ALODINED AND PRIMED FLOOR BEAM AND REPAIR ANGLES, INSTALLED PARTS PER FSDR 9614015507Floor Beam · corrodedDURING P-CHECK, FOUND CORROSION IN THE BS 377 FLOOR BEAM UPPER CHORD LBL 63 TO BL 0. REPAIRED CHORD (P/N 141N5113) PER EA 55-106085.SDR 96FDEA01079Floor Beam · corrosionNR 0353, 003 CORROSION (C53-224-01) ON FLOOR BEAM TOP CHORD BS 620, LBL 10 TO 21 AND RBL 2 TO 56 WL 208. *S/D* REPAIRED BS 620 FLOOR BEAM UPPER CHORD LBL 21 TO RBL 56 IAW FEDEX SRM 53-10-8.SDR 9614386307Floor Beam · corrodedDURING P-CHECK, FOUND CORROSION ON THE UPPER DECK FLOOR BEAM UPPER CHORD AT BS 980, RBL 20 TO RBL 30. REPAIRED BEAM (P/N 65B25643-4) PER EA 63-101956.SDR DHL9672176CFloorbeam · corrodedAT C-CHECK, FOUND CORROSION ON FLOORBEAM STA 720D LBL 60. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED FLOORBEAM UPPER CAP PER SRM 53-10-8, 12 LONG.SDR DHL9672161CFloorbeam · corrodedAT C-CHECK, FLOORBEAM STA 1070 BL 30R TO 65R HAS MANY AREAS OF CORROSION. INSTALLED CABIN FLOORBEAM REPAIR AT STA 1070, 26 BY 3, PER SRM 53-10-8 AND 53-30-2.SDR DHL9672146CFloorbeam · corrodedAT C-CHECK, FOUND CORROSION BS 480 BL TO RBL 24 FLOORBEAM TOP. REMOVED DAMAGED AREA AND REPLACED PER SRM 53-10-8, BL 0 TO RBL 24.
Back to JASC 5315