JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 9608759751Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 1041 FLOOR BEAM AT APPROXIMATELY LBL 18. REPAIRED BEAM (P/N 9958212-3) PER EA 97-109477.SDR 9608749751Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 1056 FLOOR BEAM AT APPROXIMATELY LBL 26 AND RBL 34. REPAIRED BEAM (P/N 9958187-1) PER EA 97-109476.SDR RAIA960409Floor Beam · corrodedSTL - DURING MAINTENANCE CHECK, SURFACE CORROSION WAS FOUND ON FLOOR BEAMS 36, 37, 38, 39. MAINTENANCE TREATED CORROSION PER ATR STRUCTURAL REPAIR MANUAL. (M)SDR UPS96205993Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED FLOOR BEAM UPPER FLANGE CORROSION WAS FOUND TO BE BEYOND LIMITS PER SRM 53-10-1, AT STA 560 WL 208 FROM LBL 50 TO LBL 60. REMOVED AND REPLACED FLOOR BEAM UPPER FLANGE PER SRM 53-10-8 FIG 5.SDR 96FDEA00773Floor Beam · corrodedCABIN FLOOR BEAM CORRODED ON BOTTOM SIDE STA 380 RBL 23 TO 42. REMOVED CORROSION, INSTALLED REPAIR PER SRM 53-10-8 FIG 3.SDR CAL960583Floorbeam · corrodedHOU - INSPECTION FOUND FLOORBEAM CORRODED ON TOP AND BOTTOM SURFACE AT STA 986. THE FLOORBEAM WAS REPLACED IAW SRM 53-00-51. (X)SDR CAL960447Floorbeam · crackedGSO - INSPECTION FOUND A .50 INCH CRACK AND CORROSION ON COCKPIT AFT FLOORBEAM AT STA 459. THE CORRODED AREAS WERE REMOVED. NEW ANGLES WERE FABRICATED AND INSTALLED IAW SRM 51-40-3. (X)SDR 96FDEA00772Floor Beam · corrodedCORROSION REMOVED AT FLOOR BEAM STA 360 LBL 3, AREA NOW BELOW SRM LIMITS FOR THICKNESS. TRANSFERRED FROM NR 0958. CORRODED AREA REMOVED AND FLOOR BEAM REPAIRED PER SRM 53-10-8 FIG 8.SDR 96FDEA00741Floor Beam · corrodedCORROSION (C53-224-01) ON LOWER SURFACE OF UPPER FLANGE OF FLOOR BEAM AROUND FASTENER HOLES BS 1110, RBL 10 TO 60 WL 208. REMOVED CORROSION FROM FLOOR BEAM, FOUND TO BE OUT OF LIMITS. ACCOMPLISHED FLOOR BEAM REPAIR BS 1110, RBL 10 TO 60 WL 208, IAW FEDEX SRMSDR 96FDEA00740Floor Beam · corrodedCORROSION (C53-224-01) ON FLOOR BEAM BS 344 LBL 45 AND RBL 37 WL 208. ACCOMPLISHED FLOOR BEAM REPAIR AT BS 344 LBL 45 AND RBL 37 WL 208, PER FEDEX SRM 27-53-007.SDR 96FDEA00739Floor Beam · corrodedCORROSION (C53-224-01) ON FLOOR BEAM BS 380, LBL 28 TO 34 AND LBL 55 WL 208. REMOVED CORROSION FROM FLOOR BEAM FOUND TO BE OUT OF LIMITS. ACCOMPLISHED FLOOR BEAM REPAIR PER FEDEX SRM 53-10-8.SDR 96FDEA00771Floor Beam · corrodedUPPER LOBE, CORROSION BEYOND LIMITS IN DEPTH ON TOP SURFACE OF FLOOR BEAM BS 480, RBL 26 TO 35. CUT OUT AREA OF CORROSION AND INSTALLED FLOOR BEAM REPAIR PER SRM 51-10-6, 51-10-8 FIG 6 AND 8, ESO 11782 DATE 3-20-96 AA AND EA 7-5310-28846 DATED 3-20-96 FEDEX.SDR USAA960366Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH AREA OF CORROSION ON FLOOR BEAM BS 312 8 INCH RBL. REPLACED T-CAP AND INSTALLED SPLICE ANGLES, REPAIRED PER TR NR 53-10-13. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)SDR USAA960360Floor Beam · gougesINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND TWO .5 INCH GOUGES AT BS 360 BL ZERO LBL 12 FLOOR BEAM. INSTALLED REPAIR STRAPS, REPAIRED PER TR53-10-01A. (M)SDR USAA960358Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 71 INCHES BY 30 INCHES CORROSION FLOOR BEAM BS 947.5 LBL 51 TO RBL 20. REPAIRED FLOOR BEAM, REPAIRED PER TR 53-10-05C, EA 41019. (M)SDR USAA960357Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 71 INCHES BY 3 INCHES CORROSION FLOOR BEAM BS 986.5 LBL 25 TO RBL 46. FILLER T-CAP AND SPLICES, REPAIRED PER SRM 53-10-9 TR 53-10-05C. CORROSION TASK NR C53-107-02. (M)SDR UPS96806046Floor Beam · corrosionWHILE IN FOR "C" CHECK, MAINTENANCE REPORTED WEB JUST ABOVE OUTBOARD END OF FS 80, FLOOR BEAM HAS HEAVY CORROSION. REPLACED WEB SECTION PER SRM 51-1-20D.SDR AALA960524Floorbeam · corrodedFLOORBEAM AT STATION 324 RBL 58 AND RBL 59 HAD CORROSION BLENDED BEYOND SRM LIMITS. PER MRB 75-763. (M)SDR AALA960523Floorbeam · corrodedFLOORBEAM AT STATION 365, RBL 10 AND RBL 58 HAD CORROSION REMOVED BEYOND SRM LIMITS. PER MRB 757-765. (M)SDR 9608362712Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE BS 1130 FLOOR BEAM UPPER CHORD AT LBL 16, 42 AND 48. REPAIRED CHORD (P/N 65-20822-3) PER EA 27-79525.SDR TSAA9653018Floor Beam · corrodedDURING HEAVY MAINTENANCE VISIT, FLOOR BEAM AT BS 312, FILIFORM CORROSION NOTED AROUND SEVERAL NUTPLATE HOLES. REPLACED FLOOR BEAM FROM LBL 62 TO RBL 20 PER SRM 53-10-9. AIRCRAFT RETURNED TO SERVICE. NRTC: 11,911. (X)SDR CAL960508Floor Beam · crackedGSO - AFT PIT FLOOR BEAM CRACKED, STA 727B, STR 27R AND STR 27L. CRACK APPROXIMATELY .5 INCH IN EXTRUSION. FABRICATED REPAIR PARTS IAW B737 SRM 53-10-5. TREATED AND PRIMED IAW B737 SRM 51-10-2. INSTALLED PARTS. (X)SDR 9608352712Floor Beam · crackedDURING H-CHECK, FOUND CORROSION ON THE BS 312 FLOOR BEAM UPPER CHORD AT THE A/C CENTER LINE. REPAIRED CHORD (P/N 65-16314) PER EA 27-104215.SDR UPS96206000Floor Beam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED FLOOR BEAM UPPER FLANGE AFTER CORROSION REMOVAL, FLOOR BEAM WAS FOUND TO BE BEYOND LIMITS. REMOVED DAMAGED SECTION OF FLOOR BEAM FAB AND INSTALLED PER SRM 53-10-8 FIG F, STA 680 RBL 26 TO 44 RBL 60 WL 208.SDR UPS96205828Floor Beam · corrodedWHILE IN FOR SI CHECK, MAINTENANCE REPORTED CORROSION ON LOWER FLANGE OF FLOORBEAM STA 1110, WL 200, AND LBL 9-19. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. CUT LOWER FLANGE AND REPAIRED PER E.O. 727-53-1745.SDR MWEA96094Floor Beam · damagedFOUND FLOOR BEAM AT STA 408 HAS DAMAGE ON LOWER FLANGE FROM FWD CARGO DOOR CONTACT. INSTALLED DOUBLER REPAIR IAW SRM 53-05 FIG 86.SDR MWEA96080Floor Beam · damagedFOUND FLOOR BEAM AT STA 389 HAS DAMAGE ON LOWER FLANGE FROM CARGO DOOR CONTACT. INSTALLED DOUBLER REPAIR IAW SRM 53-05 FIG 86 AND DAC FAX 029183.SDR UPS96205817Floor Beam · corrodedWHILE IN FOR SI CHECK, MAINTENANCE REPORTED CORROSION ON FLOOR BEAM UPPER CHORD STA 1130 RBL 65 WL 207. REMOVED AND REPLACED CHORD PER SRM 51-30-2.SDR UPS96205816Floor Beam · corrodedWHILE IN FOR SI CHECK, MAINTENANCE REPORTED CORROSION ON FLOOR BEAM UPPER CHORD STA 1130 LBL 65 WL 207. REMOVED CORROSION PER SRM 53010-1 AND REPAIRED FLOOR BEAM IAW UPS EO 727-53-1744.SDR AWXA960170Floorbeam · corrodedFLT NR 3838 - PAE - DURING ROUTINE SCHEDULED C-3 MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM UPPER CHORD STATION 365, BL 0 TO RBL 60, WL 208. BLENDED CORROSION, FOUND OUT OF LIMITS. FABRICATED REPAIR CHORD AND ANGLES. ALODINED AND PRIMED PER SRM 53-00-5SDR AWXA960169Floorbeam · corrodedDURING ROUTINE SCHEDULED C-3 MX CHECK, FOUND CORROSION ON FLOORBEAM AT STATION 350, RBL 2-LBL 20, WL 208. REPAIR AREAS OF FLOORBEAM THAT ARE OUT OF LIMITS WITH REPAIR ANGLE AND FILLERS PER SRM 53-00-51. ALODINE, PRIME AND INSTALL WET WITH SEALANT. (M)SDR AWXA960165Floor Beam · corrodedPAE - FLT 3838 - DURING ROUTINE SCHEDULED C-3 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT BS 350, RBL 2 - LBL 20, WL 208. PER ERR, BLENDED CORROSION ON BEAM. FABRICATED REPAIR ANGLE, ALODINED, PRIMED, AND INSTALLED PART WITH SEALANT PER ER 5-53-12-05SDR 9608329861Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 1136 FLOOR BEAM UPPER CAP UNDER THE RIGHT LAV INBOARD FLOOR SUPPORT. REPAIRED BEAM (P/N 9912243-55) PER EA 98-109466.SDR 9608319861Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 1167 FLOOR BEAM UPPER CAP FROM THE RIGHT CUSP TO THE RIGHT INBOARD LAV WALL. REPAIRED BEAM (P/N 9915561-1) PER EA 98-109486.SDR 9608009861Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FLOOR BEAM UPPER CAP AT FS 1151 LEFT SIDE. REPAIRED BEAM (P/N 9958188-1) PER EA 98-109489.SDR CAL960484Floor Beam · crackedGSO - INSPECTION FOUND A 2 INCH CRACK IN RADIUS OF FLOOR BEAM LOWER T-CHORD AT BBL ZERO, STA 675. THE FLOOR BEAM CHORD WAS REPAIRED IAW ECRA 5710-01462 AND BOEING DRAWINGS 65C19643, 65C17173, ND 65C17103. (X)SDR 96FDEA00693Floor Beam · corrodedCORROSION (C53-224-01) ON FLOOR BEAM BS 360 LBL 12 RBL 5 AND 48 WL 208. REPAIRED FLOOR BEAM BS 360 LBL 12 AND RBL 5 WL 208. FOUND FLOOR BEAM BS 360 RBL 48 TO BE WITHIN SERVICEABLE LIMITS. CLEANED AND TREATED BS 360 RBL 48 WL 208 PER FEDEX SRM 51-10-6. REPASDR UPS96205802Floor Beam · corrosionWHILE IN FOR SI CHECK, MAINTENANCE REPORTED CORROSION ON FLOOR BEAM STA 328 LBL 4, 19 AND 46, WL 208. REMOVED CORROSION, CUT FLOOR BEAM UPPER FLANGE AT RBL 18 TO LT END, FABRICATED NEW CHORD AND INSTALLED PER SRM 53-10-8.SDR SWAA960174Floor Beam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM AFT FLANGE CORRODED AT BS 312 LBL 15. REPAIRED PER BOEING SRM.SDR SWAA960172Floor Beam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM NUTPLATE HOLE CORRODED AT BS 986.5 RBL 30. REPAIRED PER BOEING SRM.SDR SWAA960171Floor Beam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM NUTPLATE HOLE CORRODED AT BS 986.5. REPAIRED PER BOEING SRM.SDR C2XA96IA083Floor Beam · corrodedIAH - DURING C-CHECK INSPECTION, FOUND CORROSION ON FRAME 36 FLOOR SUPPORT BEAM. REMOVED FRAME 36 FLOOR SUPPORT BEAM, FABRICATED, AND INSTALLED NEW SUPPORT BEAM, AND THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR C2XA96IA082Floor Beam · corrodedIAH - DURING C-CHECK INSPECTION, FOUND CORROSION ON FS 38 FLOOR SUPPORT BEAM. REMOVED FS 38 FLOOR SUPPORT BEAM, FABRICATED AND INSTALLED NEW SUPPORT BEAM, AND THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR USAA960332Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION MEASURING 3 INCH BY 60 INCH LOCATED AT LT ENTRY AFT DOOR THRESHOLD LOCATED AT STA 947 THROUGH STA 1006. INSTALLED REPLACEMENT ANGLE PER BOEING SRM 51-10-02. (X)SDR ABXA9600466Floor Beam Web · crackedDURING C-CHECK INSPECTION, FOUND CRACKS IN THE FLOOR BEAM WEBS AT STA 180 LBL 19 AND LBL 22. REPAIRED IAW DC-9 SRM 53-05, FIGURE 75.SDR 96FDEA00678Floor Beam · corrodedCORROSION ON BS 1130 FLOOR BEAM RBL 55 TO LBL 55 WL 200 AT NUTPLATE HOLES. REPAIRED DAMAGED AREA ON BS 1130 FLOOR BEAM RBL TO LBL 55 WL 200 AT NUTPLATE HOLES PER FEDEX EA NR 7-5310-28075.SDR USAA960328Floor Beam · corrodedINT - DURING 'Q-1' CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA, BS 312, FLOOR BEAM BL ZERO. CUT OUT CORRODED SECTION OF UPPER CHORD FROM LBL 38 TO RBL 25 AND SPLICED IN NEW CHORD SECTION. REPAIRED PER T.R. 53-10-03. CORROSION TASK NR C53-1SDR USAA960327Floor Beam · corrosionINT - DURING 'Q-1 CHECK VISUAL INSPECTION, FOUND SEVERAL 1 INCH BY 2 INCH CORRODED AREAS BS 328 FLOOR BEAM, RBL 14 INCH TO RBL 56 INCH. SPLICED SECTION AND REPAIRED PER SRM 53-10-01. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (X)SDR USAA960326Floor Beam · corrosionINT - DURING 'Q-1' CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA BS 344 FLOOR BEAM LBL 9 INCH AND LBL 21 INCH. INSTALLED T-CAP FROM RBL 17 TO LBL 36, REPAIRED PER T.R. 53-10-03. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. (X)SDR USAA960325Floor Beam · corrodedINT - DURING 'Q-1' CHECK, VISUAL INSPECTION FOUND 10 AREAS 1 - 2 INCH SQUARES OF CORROSION FLOOR BEAM (FLOOR BOARD HOLES) BS 986.5, RBL 46 - LBL 46. CUT OUT CORRODED UPPER T-CAP AND REPLACED T-CAP, PLACING A SPLICE AT LBL 7, REPAIRED PER EA 40946. (X)
Back to JASC 5315