SDR 9604389865Floorbeam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 1136 FLOORBEAM AT APPROXIMATELY RBL 18. REPAIRED BEAM PER EA 98-106626.SDR USAA960157Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 24 INCH CORROSION AT CABIN FLOOR BEAM STATION 947 LBL 12 INCHES TO RBL 12 INCHES. INSTALLED T-CAP AND REPAIRED DOUBLERS. REPAIRED PER TR 53-10-13. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (MSDR USAA960133Floor Beam · crackedINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK BS 520 RBBL 25 FLOOR BEAM. INSTALLED DOUBLER. REPAIRED PER EA 40741 SB 737-53-1120. (M)SDR USAA960132Floor Beam · crackedINT - DURING Q-4 EDDY CURRENT INSPECTION, FOUND .5 INCH CRACK BS 520 RBBL 45.50 FLOOR BEAM. INSTALLED DOUBLER. REPAIRED PER EA 40741 SB 737-53-1120. (M)SDR USAA960131Floor Beam · crackedINT - DURING Q-4 CHECK HIGH FREQUENCY EDDY CURRENT, FOUND .0625 INCH CRACK BS 520 LBBL 45.50 FLOOR BEAM. INSTALLED DOUBLER. REPAIRED PER EA 40741 SB 737-53-1120. (M)SDR USAA960130Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 2 PLACES 3 INCHES BY 8 INCHES AND 3 INCHES BY 20 INCHES FLOOR BEAM T-CAP, BS 344 LBL 55 AND RBL 8 TO LBL 14. REPLACED 4 FEET OF T-CAP. REPAIRED PER TR 53-10-13. (M)SDR USAA960127Floor Beam · crackedINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CRACK IN WEB CUT OUT FOR LEFT AILERON BELLCRANK (1 INCH CRACK), BS 680 LBL 24 AND RBL 24 WEB OF FLOOR BEAM AT AILERON CUTOUT. INSTALLED REINFORCEMENT. REPAIRED PER EA 40739 AND SB 737-53-1130, R 4 FIG 5. (M)SDR USAA960126Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 20 INCH CORROSION FLOOR BEAM STATION 312, LBL 11 TO RBL 11. REPLACED T-CAP. REPAIRED PER TR 53-10-13. (M)SDR USAA960124Floor Beam · crackedINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CRACK IN WEB 4 INCHES AT FLOOR BEAM, BL O, STATION 706-710. CUTOUT CRACKED WEB AND INSTALLED FILLER AND DOUBLER. REPAIRED PER BOEING REPAIR DRAWING NR 65C34537. (M)SDR USAA960119Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER CORROSION FLOOR BEAM FS 328 RBL 20 1/2. REMOVED DAMAGED 'T' CHORD FROM LBL 29 TO RBL 65. REPAIRED PER TYPICAL REPAIR NR 53-10-13 AND SRM CHAPTER 51-40-2 FIG 1. CORROSION TASK NR C53-107-02, CORSDR USAA960115Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER CORROSION PIT, TOP CAP FLOOR BEAM, STATION 328 AT RBL 20. REMOVED TOP 'T' OF FLOOR BEAM AND INSTALLED NEW T-CAP. REPAIRED PER TYPICAL REPAIR 53-10-13. CORROSION TASK NR C53-107-02, CORROSION LESDR USAA960113Floor Beam · crackedINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1.5 INCH CRACK BS 520 LBL 25 WL 207.75 UPPER CHORD FLOOR BEAM. STOP DRILLED CRACK .25 INCH. INSTALLED REPAIR DOUBLER AND FLOOR BEAM MOD. REPAIRED PER EA 40741. (M)SDR UPS405318Floorbeam · corrodedWHILE IN FOR C-CHECK AMS MAINTENANCE REPORTED, FLOORBEAM UPPER CHORD CORRODED AT BS 1580 LBL 0. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-04.SDR ABXA9600399Floor Beam Web · corrodedDURING C AND D-CHECK ACCEPTANCE INSPECTIONS, FOUND A FLOOR BEAM WEB CORRODED AT FS 996. REPAIRED FLOOR BEAM WEB AT FS 996 IAW ABX REA D953-14201-MR.SDR 9603815514Chord · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON THE BS 345 FLOORBEAM UPPER CHORD FROM LBL 8 TO BL 0. REPAIRED CHORD PER EA 55-13905.SDR CAL960269Floor Beam · corrodedSTATION 31J - INSPECTION FOUND ELONGATED HOLES AND PITTING CORROSION IN FLOOR BEAM AND SEAT TRACK AT BS 1010, RBL 55. THE AREA OF ELONGATED HOLES WAS CUT OUT. REPAIR ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-40-3, FIGURE 1. (M)SDR CAL960172Floor Beam · corrodedKUL - INSPECTION FOUND CORROSION ON FLOOR BEAM AT STATION 1701. REPAIRED IAW ECRA 5310-03225. (M)SDR AALA960187Floor Beam · corrodedAFW - FOUND AND REMOVED CORROSION ON FLOOR BEAM. AFTER BLENDING, FOUND BEYOND SRM LIMITS. EDDY CHECKED BLEND-OUTS. ROTO-PEENED AND REFINISHED BLENDED AREAS. APPROVED BY ENGINEERING PER MRB 767-1118. TST: 42,562.49 HRS. CYCLES, 10,821. (X)SDR AALA960186Floor Beam · corrodedAFW - FLOOR BEAM CORRODED AND BLENDED ON THE UPPER OUTER SURFACE. FOUND THE BLEND-OUT EXCEEDED SRM LIMITS. REMOVED FLOOR BEAM SECTION FROM STA 849 TO STA 878. SPLICED IN NEW SECTION. APPROVED BY ENGINEERING PER MRB 767-1119. TST: 42,562.49 HRS. CYCLES, 1SDR AALA960185Floor Beam · corrodedAFW - FLOOR BEAM CORRODED. AFTER BLENDING, FOUND DAMAGE BEYOND SRM LIMITS. ALODINED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STOP USING .050 INCH 301 1/2 HARD STAINLESS STEEL. APPLIED TWO COATS OF PRIMER. APPROVED BY ENGINEERING PER MRB 767-1124. TSSDR AALA960183Floor Beam · gougedAFW - FLOOR BEAM WEB GOUGED. DAMAGE BLENDED AND FOUND BEYOND SRM LIMITS. FABRICATED AND INSTALLED .071 INCH THICK 7075-T6 DOUBLER. APPROVED BY ENGINEERING PER MRB 767-1126. TST: 42,562.49 HRS. CYCLES, 10,821. (X)SDR USAA960102Floor Beam · crackedCLT - INSPECTION FOUND BY HFEC, A CRACK APPROXIMATELY 1 INCH LOCATED AT FLOOR BEAM STATION 520, LBL 45. FABRICATED AND INSTALLED DOUBLERS AND FILLERS AS PER USAIR EA NR 40604. (M)SDR USAA960101Floor Beam · crackedCLT - INSPECTION BY HFEC, FOUND A CRACK APPROXIMATELY 1 INCH LOCATED AT THE FLOOR BEAM, STATION 520, RBL 45. FABRICATED AND INSTALLED DOUBLERS AND FILLERS AS PER USAIR 40604. (M)SDR USAA960100Floor Beam · crackedCLT - INSPECTION BY HFEC, FOUND A CRACK APPROXIMATELY 1 INCH, LOCATED AT THE FLOOR BEAM, STATION 520, LBL 25. INSTALLED DOUBLER AND RADIUS BLOCK AS PER USA EO NR 40604. (M)SDR ABXA9600381Floor Beam · chafedDURING C AND D-CHECK ACCEPTANCE INSPECTIONS, FOUND THE FLOOR BEAMS AT FS 389 AND 408 GOUGED AND CHAFED. REPAIRED FLOOR BEAMS IAW ABX REA D953-13826-MR.SDR ABXA9600380Floor Beam · chafedDURING C AND D-CHECK ACCEPTANCE INSPECTIONS, FOUND THE FLOOR BEAM AT FS 389 AND 408 GOUGED AND CHAFED. REPAIRED FLOOR BEAMS IAW ABX REA D953-13826-MR.SDR CAL960265Floor Beam · corrodedINSPECTION FOUND FLOOR BEAM UPPER CHORD CORRODED AT BS 1110, RBL 26 TO RBL 44. THE CORRODED SECTION OF FLOOR BEAM UPPER CHORD WAS REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8, SRM 51-10-2, AND MM 51-20-151. (X)SDR ABXA9600395Floor Beam · chafedDURING C AND D-CHECK ACCEPTANCE INSPECTIONS, FOUND THE FLOOR BEAM AT FS 980 HAD UPPER FLANGE CHAFE DAMAGE AT BL 40.0 AND 50.0. REPAIRED FLOOR BEAM AT FS 980 IAW ABX REA D953-14061-MR.SDR AALA960197Floor Beam · corrodedAFW - CORROSION ON THE UPPER SURFACE OF THE CABIN FLOOR BEAM. BLEND, SHIM, AND PAINT PER MRB 767-1122. TST: 32,231.54 HRS. CYCLES, 5,446. (X)SDR AALA960196Floor Beam · gougedAFW - FLOOR BEAMS HAVE DEEP GOUGES. BLEND AND REFINISH PER MRB 767-1130. TST: 32,231.54 HRS. CYCLES, 5,446. (X)SDR AALA960195Floor Beam · corrodedAFW - CORROSION ON THE UPPER SURFACE OF TWO MAIN CABIN FLOOR BEAMS. BLEND, SHIM, AND REFINISH PER MRB 767-1120. TST: 32,231.54 HRS. CYCLES, 5,446. (X)SDR AWXA960017Floor Beam · corrodedPAE - FLT 3877 - DURING SCHEDULED C-CHECK, FOUND CORROSION ON UPPER CHORD OF FLOOR BEAM BS 967, WL 208, RBL 14 TO 50. REMOVED CORRODED UPPER FLOOR BEAM FROM BS 967, RBL 14 TO 50. FABRICATED NEW UPPER CHORD, BACK DRILLED CHORD, FABRICATED REPAIR ANGLES, ALODISDR AWXA960016Floorbeam · corrodedPAE - FLT 3887 - DURING C-9 INSPECTION, FOUND CORROSION ON BS 987 UPPER CHORD OF FLOORBEAM WL 208, RBL 45 TO RBL 50. REMOVED CORRODED UPPER CHORD OF BS 987 FROM LBL 27 TO LBL 53, WL 208. FABRICATED NEW UPPER CHORD. SPLICE ANGLES AND FILLERS PER SRM 53-10-09SDR AALA960132Floor Beam · corrodedTUL - CORROSION BEAM LT SIDE OUTBOARD END AT THE ROLLER TRAY, FRAME STA 63. INSTALLED NEW SECTION OF FLOORBEAM PER SRM 53-10-15 AT FRAME 63 AND TREATED, PRIMED, AND PAINTED PER SRM 51-74-10. TST, 20,955 HOURS. CYCLES, 8,316. (X)SDR AALA960092Floorbeam · corrodedTUL - CORROSION ON UPPER FLOORBEAM FLANGE TOP AND BOTTOM AT NUTPLATE HOLES AT STA 1841, LONGERONS 43L TO 43R. MANUFACTURED AND INSTALLED NEW FLOORBEAM PER AARD 51-01-00-05, PAGE 1. TST, 54,115.43 HOURS. CYCLES, 18,537. (X)SDR USAA970017Floorbeam · corrosionCLT - INSPECTION VISUALLY FOUND MULTIPLE LEVEL 2 CORROSION MEASURING 1 INCH BY 1 INCH LOCATED AT FLOORBEAM STATION 986, B10 BL 46 L PLUS R. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. REPAIRED FLOORBEAM PER SRM 53-60-51 AND TYPICAL REPAIR MANUAL 53-15-0SDR USAA960096Floor Beam · wornINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .1875 INCH GROOVE WORN INTO CHANNEL ON CABIN FLOOR BEAM, BS 520 AT RBL 24.75. INSTALLED REPAIR PER SB AND EA. REPAIRED PER SB 737-53-1120 REV 1 AND EA 40649. (M)SDR USAA960095Floor Beam · wornINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .1875 GROOVE WORN IN CHANNEL ON CABIN FLOOR BEAM, BS 520 AT LBL 24.75. INSTALLED REPAIR PER SB AND EA, REPAIRED PER SB 737-53-1120 REV 1 AND EA 40649. (M)SDR USAA960093Floor Beam · wornINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .25 INCH GROOVE WORN INTO CHANNEL ON CABIN FLOOR BEAM AT BS 520 AT BBL 0. INSTALLED REPAIR PER SB AND EA. REPAIRED PER SB 737-53-1120 REV 1 AND REV 2 AND EA 40548. (M)SDR USAA960088Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 2 INCH CORRODED AREA BL 0 BS 360, FLOOR BEAM. FABRICATED AND INSTALLED REPAIR ANGLE. REPAIRED PER SRM 53-30-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960085Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND SEVERAL 1 INCH BY 1 INCH CORRODED NUT PLATE HOLES FLOOR BEAM, BS 986 LBL 45 INCHES TO RBL 45 INCHES. MODIFIED PART NR INSTALLED, EXT BAC1505-100703, 7075-T65, BAC1490-2887 AND 2886. REMOVED DAMAGED T-CAP. COMPSDR USAA960074Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND SEVERAL AREAS .75 INCH BY .75 INCH CORROSION ON FLOOR BEAM STATION 328 RBL 11 TO RBL 57. SPLICED IN NEW UPPER CHORD SECTION. REPAIRED PER SRM 53-10-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960071Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 50 INCHES CORRODED FLOOR BEAM BS 294.5 RBL 6, RBL 56. INSTALLED T-CAP AND REPAIR ANGLES AND FILLER, REPAIRED PER SRM 53-10-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960068Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 53 INCHES CORROSION FLOOR BEAM, BS 344 LBL 37 TO RBL 16. INSTALLED T-CAP AND REPAIR ANGLE AND STRAPS. REPAIRED PER TR 53-10-03. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960066Floor Beam · corrosionINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER AREA OF CORROSION STATION 947 FLOOR BEAM UPPER FLANGE RBL 4, WL 208. CUTOUT DAMAGED FLOOR BEAM AND INSTALLED FILLER AND REPAIR ANGLES. REPAIRED PER SRM 53-60-51. CORROSION TASK NR C53-107-02, CSDR CAL960261Floor Beam · corrodedINSPECTION FOUND FLOOR BEAM UPPER CHORD CORRODED AT BS 344, RBL 20 TO LBL 20. THE CORRODED UPPER CHORD WAS REMOVED. A NEW CHORD WAS FABRICATED AND INSTALLED IAW SRM 53-10-8. FIGURE 3. (X)SDR SWAA960026Floorbeam · corrodedDURING SCHEDULED MAINT CHECK, FOUND FWD GALLEY FLOORBEAM CORROSION UPPER TEE CAP FASTENER BS 294 LBL 11. REPAIRED PER BOEING SRM.SDR SWAA960024Floorbeam · corrodedDURING SCHEDULED MAINT CHECK, FOUND AFT GALLEY FLOORBEAM CORROSION AROUND FASTENER HOLE AND MIGRATING UNDER WEB AT BS 1016, FWD FLANGE LBL 0 TO 39. REPAIRED PER SWA RA 1-253-1415.SDR SWAA960023Floorbeam · corrodedDURING SCHEDULED MAINT CHECK, FOUND AFT GALLEY FLOORBEAM CORRODED AROUND FASTENER HOLE AT BS 1006 AFT FLANGE, LBL 15 TO 28. REPAIRED PER SWA RA 1-253-1417.SDR SWAA960022Floorbeam · corrodedDURING SCHEDULED MAINT CHECK, FOUND AFT GALLEY FLOORBEAM CORRODED AROUND FASTENER HOLE AT BS 986.5 LBL 10. REPAIRED PER SWA RA 1-253-1419.
Back to JASC 5315