As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOOR BEAM CORRODED AND BLENDED ON THE UPPER OUTER SURFACE. FOUND THE BLEND-OUT EXCEEDED SRM LIMITS. REMOVED FLOOR BEAM SECTION FROM STA 849 TO STA 878. SPLICED IN NEW SECTION. APPROVED BY ENGINEERING PER MRB 767-1119. TST: 42,562.49 HRS. CYCLES, 10,821. (X)