JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023110808772Floorbeam · crackedCRACK ANGLE FLOOR STRUCTURE BS540 AND BL0 TO LBL 24.75 CENTER SECTION 2023-637666<[01] REPLACED ANGLE FLOOR STRUCTURE BS540 AND BL0 TO LBL24.75 CENTER SECTION IAW SRM B737-700 51-40-02 AND SRM 51-10-02 ITEM 9;[02] CORRECTIVE ACTION CERTIFIEDSDR DALA2023101008312Unknown · unknown(LOG 0006137) FWD WET AREA STA 328 FLOOR BEAM HAS MULTIPLE SPOTS OF CORROSION RBL 24-RBL60. REMOVED EXISTING T CHORD REPAIR & FABRICATED NEW T CHORD & INSTALLED IAW BOEING 737-800 SRM 53-10-51-2R-7.SDR SWAA2023121808298Floorbeam · crackedFWD CABIN BETWEEN STA 380 AND STA 400 AT RBL 8.5 WL 208.1 - INTERCOSTAL FLOOR SUPPORT ANGLE CRACKED. 124-034<[01] REMOVED AND REPLACED FWD CABIN BETWEEN STA 380 AND STA 400 AT RBL 8.5 WL 208.1 - INTERCOSTAL FLOOR SUPPORT ANGLE PER SRM 51-40-02-0G-0;[02] VERIFISDR SWAA2023110308664Floorbeam · corrodedCORROSION FLOOR BEAM UPPER CHORD BS 987 RBL 48 WL 208<[01] ACCOMPLISHED REPAIR ON FAULT#TTG8Q00NU8D9 PER SRM 53-70-51-2R-4 REPAIR 4 AND PER EA#23-153-03055-WIP1;[02] VERIFIED CORRECTIVE ACTION #1SDR AALA202310095635Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 65 AND FR 66 AT -Y1732. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR SWI2023F00551Unknown · cracked* FLOOR BEAM LBL12, CRACKED AT ATTACH FLANGE TO FS280 FLOOR POST, FORWARD SIDE, BELOW FLOOR. (C-CHECK RO 12/04/2023) PERFORMED CENTER COCKPIT FLOOR BEAM BL12 TYPE IV REPAIR IAW CRJ700 SRM 53-11-43-201-003-A01, REMOVED AND REPLACED LBL12 FLOOR BEAM SECTIONSDR SWI2023F00550Unknown · cracked* FLOOR BEAM RBL12, CRACKED AT ATTACH FLANGE TO FS280 FLOOR POST, FORWARD SIDE, BELOW FLOOR. (C-CHECK RO 12/04/2023) REMOVED CRACKED FLOOR BEAM AT RBL 12. FABRICATED AND INSTALLED NEW FLOOR BEAM. REF. CRJ700 SRM 53-11-43-201-003-A01 REV 38 DATED JUL 25/20SDR SWAA2023111007814Floorbeam · corrodedCORROSION AT AFT WET AREA FLOOR SUPPORT BEAM FASTENER HOLE STA 986.5 LBL 45 MKD DOT<[01] COMPLETED SME INSPECTION.;[02] ACCOMPLISHED REPAIR AT AFT WET AREA FLOOR SUPPORT BEAM STA 986.5 LBL 45 MKD AS PER SRM 53-70-51-2R-6;[03] RII -- VERIFIED REPAIR AT AFT WET SDR SWAA2023111007811Floorbeam · corrodedAFT CABIN WET AREA FLOOR SUPPORT BEAM UPPER CAP AT STA 986.5 RBL 24 TO RBL 45 MKD DOT CORRECTION ADDED INFORMATION ; CORROSION AT<[01] REMOVED CORROSION FROM AFT WET AREA STA 986.5 FLOOR BEAM UPPER RBL 24 TO RBL 45; EVALUATED CORROSION REMOVAL AT AFT WET AREA SDR SWAA2023110307622Floorbeam · corrodedCORROSION ON BS 986 FLOOR BEAM; LBL46; WL208<[01] ACCOMPLISHED REPAIR PER SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 4 FIGURE 205;[02] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.SDR SWAA2023110307623Floorbeam · corrodedCORROSION ON BS 986 FLOORBEAM; RBL 46; WL 208<[01] REPAIRED PASSENGER FLOORBEAM BS 986 IAW SRM 53-70-51-2R-4 REPAIR 4 AND PER EA#23-153-03055-WIP-1;[02] CORROSION ON BS 986 FLOORBEAM; RBL 46; WL 208 WAS REPAIRED IAW EA 23-153-03055;[03] VERIFIED STEPS COMPLETESDR SWAA2023111007544Floorbeam · corrodedCORROSION AT FWD CABIN WET AREA FLOOR SUPPORT BEAM UPPER SURFACE AFT FLANGE RBL 10 STA 294;5 WL 208.1 MKD DOT<[01] ACCOMPLISHED FWD CABIN FLOOR BEAM UPPER CHORD AT STA 294.5 BETWEEN RBL-24 TO LBL-21 REF USED B737-700 SRM 53-10-51-2R-16 FIGURE 202 DETAIL(A)(B)(SDR DALA2023101108361Unknown · unknownSHIP 0695 CORROSION ON FLOOR STA 1681.8 BTW LBL 57 TO RBL 57. CORRECTIVE ACTION: CORROSION (3EAS) WERE REWORKED AND EVALUATE AS FOLLOWS CORROSION LBL 25.5 STA 1681.8 WAS EVALUATED AND FOUND WHITIN ALLOWABLE LIMITS WITH NEXT DIMENSION L= 1.100" W= .700" D= 12% SDR SWIA20231003Unknown · corrodedCORROSION FOUND ON FLOOR SUPPORT ANGLE AT FS 280.0 LBL 9.0 - RBL 9.0 (C-CHECK RO 12/04/2023) REMOVED AND INSTALLED NEW FLOOR SUPPORT ANGLE AT FS 280.00 BETWEEN RBL 9 - LBL 9 REF CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRM 51-42-21-001-001-A01 AND DWG CC670SDR AALA202310171457Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON MAIN CABIN FLOOR BEAM UPPER CHORD AT BS 947, RBL 24. REPAIRED FLOOR BEAM UPPER CHORD PER SRM 53-70-51-2R-5.SDR JR2R20231003687Floorbeam · corrodedFLOORBEAM FR14 CORRODED BETWEEN RBL12 THRU RBL36SDR AALA202310209635Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON UPPER CHORD OF FLOOR BEAM AT STA 986, LBL 52. REPAIRED PER SRM 53-70-51-2R-6 ALTERNATIVE REPAIR #4.SDR F3LA2023101000186Floorbeam · corrodedAIRCRAT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. FWD CABIN WET AREA UNDERFLOOR FLOOR BEAM AT FR 16 L/H SIDE Y254 HAS CORROSION. REMOVED AND REPLACED FWD CABIN WET AREA FR16 L/H SIDE Y254 WITH NEW PAR #D5311281820401 IAW A320 SRM 51-75-12-911-001, 5SDR DALA2023100308113Unknown · unknown(LOG 2998310) FWD WET AREA STA 344 FLOOR BEAM HAS AREA OF CORROSION AT BL 0. REPAIRED FLOOR BEAM STA 344 IAW BOEING 737-800 SRM 53-10-51-2R-9.SDR REXA2022100400817Floorbeam · corrodedLBL 9 FLOOR BEAM TAB IS CORRODED AT F.S. 333 I/B SIDE. REMOVED UNSERVICABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01. INSTALLED NEW SERVICEABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR REXA2022100200808Floorbeam · corrodedLBL 9 FLOOR BEAM TAB IS CORRODED AT F.S. 349 I/B SIDE. REMOVED UNSERVICABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01. INSTALLED NEW SERVICEABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR REXA2022100200807Floorbeam · corrodedRBL 9 FLOOR BEAM TAB IS CORRODED AT F.S. 333 I/B SIDE. REMOVED UNSERVICABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01. INSTALLED NEW SERVICEABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR REXA2022100200806Floorbeam · corrodedLBL 9 FLOOR BEAM TAB IS CORRODED AT F.S. 333 I/B SIDE. REMOVED UNSERVICABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01. INSTALLED NEW SERVICEABLE PACKER P/N SH670-32167-3 IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR SWAA2023103005951Floorbeam · crackedCRACK ON HOLE OF FLOOR BEAM BST 294.5 WL 208.1 RBL 55 AT FWD GALLEY AREA 2023-594630<[01] TOOL USED: EDDY CURRENT EQUIPMENT. P/N: NORTEC 600D. S/N: 210138003. DUE DATE: 27-MAR-24.;[02] TOOL USED: EDDY CURRENT EQUIPMENT; PN: NORTEC 600D; SN: 210138003; DUE DATESDR DALA2023100608228Unknown · unknown(LOG 2999760) FUSELAGE UPPER FLOOR LEVEL STA 947 WITH CORROSION BEAM. UPPER T-CHORD FLLOOR BEAM ON STA 947 WAS REPLACED I.A.W. B737-800 SRM 51-10-02-0G PARA 9 AND 51-40-02-0G.SDR DALA2023100608227Unknown · unknown(LOG 2999757) PASSENGER COMPARTMENT, AFT GALLEY, LH AND RH SIDE ON STA 947.5, FLOOR BEAM WITH SEVERAL POINTS OF CORROSION. PASSENGER COMPARTMENT, AFT GALLEY, LH AND RH SIDE ON STA 947.5 T-CHORD UPPER FLOOR BEAM WAS REPLACED I.A.W. B737-800 SRM 51-10-02-0G PARASDR SWIA202311240929Unknown · corrodedFS280 CROSS BEAM FLOOR SUPPORT ANGLE HAS EXFOLIATED CORROSION AROUND FASTENER HOLES (CAMP 27228054) (C-CHECK RO 11/20/2023) REMOVED AND REPLACED FS280 CROSS BEAM FLOOR SUPPORT ANGLE BETWEEN LBL 9 - RBL 9 PER DWG# CC670-33052 REV -G, DWG# CC670-51620 REV-B,SDR SWIA20230928Unknown · crackedFLOOR BEAM SUPPPORT FITTING ON RBL9 FS461 IS CRACKED (C-CHECK RO 11/21/2023) REMOVED AND INSTALLED NEW FLOOR BEAM SUPPORT OUTBOARD FITTING ON RBL9 AT FS461 REF CRJ 200 SRM 51-42-06 AND CRJ 200 SRM 51-42-21 WITH DRAWINGS 601R31118 REV L AND 600-31146 REV LSDR FDEA202309281759Floorbeam · corrodedMAIN DECK FLOOR CROSS BEAM FOUND CORROSION AT FR47 Y-330 TO Y-400 REPLACED THE CROSS BEAM WITH FASTENERS I.A.W A300-600F SRM 51-72-10-001, PAGE.2 & 51- 40-21-001, PARA.6-7, PAGE.7B~50SDR DALA2023100208056Unknown · unknown(LOG 2989947) FLOOR SUPPORT DAMAGED AT BS 540 BETWEEN BL 0 TO LBL 24. REMOVED AND REPLACED FLOOR SUPPORT P/N 143A52405240U33 AT PASSENGER CABIN AT STA 540 BETWEEN BL 0 TO LBL 24 PER B737-900 SRM 51-40-02-0G AND DWG # 143A0060 REV.-B.SDR SWI2023F00500Unknown · corrodedFLOOR BEAM FS 1021.0 THRU FS1041.0 RBL27 IS PITTED AND CORRODED. FLAGGED (C-CHECK RO 11/20/2023) REPAIRED FLOOR BEAM SECTION AT RBL 27.0 BETWEEN F/S 1021.0 AND F/S 1041 IAW CRJ 700 SRM 53-00-41-201-001-A01, CRJ 700 SRM 51-42-06-001-001-A01, CRJ 700 SRM 51-SDR SWI2023F00499Unknown · corrodedFLOOR BEAM FS 1021.0 THRU 1041.0 RBL 9.0 IS PITTED AND CORRODED FLAGGED (C-CHECK RO 11/20/2023) REPAIRED FLOOR BEAM SECTION AT RBL 9.0 BETWEEN F/S 1021.0 AND F/S 1041 IAW CRJ 700 SRM 53-00-41-201-001-A01 AND COMPLIED WITH SKYWEST TASK CARD 51-900-1002 SKYSDR SWI2023F00498Unknown · corrodedFLOOR BEAM FS 1021.0 THRU FS1041.0 LBL9 IS PITTED AND CORRODED. FLAGGED (C-CHECK RO 11/20/2023) REMOVED AND REPLACED CORRODED SECTION OF FLOOR BEAM AT LBL 9 BETWEEN FS1000 AND FS1069.75 WITH NEW FABRICATED REPAIR FLOOR BEAM SECTION AND SPLICE ANGLES REF.SDR SWIA202311240925Unknown · corrodedFLOOR BEAM FS 1021.0 THRU FS1041.0 LBL27 IS PITTED AND CORRODED. FLAGGED (C-CHECK RO 11/20/2023) REMOVED AND INSTALLED NEW BEAM SECTION BETWEEN F/S 977.00 TO F/S 1069.75 LBL27 IAW CRJ 700 SRM 53-00-41-201-001-A01. COMPLIED WITH SKYWEST TASK CARD: 51-900-SDR AALA202310093075Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOOR BEAM AT FR 16 AND +Y765. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR REXA2024021200185Floorbeam · corrodedFOUND CORROSION ON L/H 280 CROSSBEAM REMOVED AND REPLACED LH FS 280 CROSSBEAM IAW CRJ900 SRM 51-42-21-001-001-A01, 51-42-06-001-001-A01, AND SB 670BA-53-041 REV M DATED 9/20/22SDR SWAA2023103003827Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED BS 986.5 RBL 43 AND WL 208.1 AT AFT GALLEY AREA 2023-594371<[01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 31-JAN-24.;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/NSDR SWAA2023103003835Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED BS 986.5 LBL 43 AND WL 208.1 AT AFT GALLEY AREA 2023-594374<[01] TOOL USED: ULTRASONIC EQUIPMENT P/N: 45 MG; S/N: 130060401; DUE DATE: 20-MAR-24.;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DSDR SWAA2023102003747Floorbeam · corrodedAT BS 947; RBL 14 TIE DOWN LUG HAS CORROSION.<[01] REMOVED CORROSION FROM FLOOR BEAM AT STA 947; RBL 26 TO 27 AND FOUND DAMAGE TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. TIE DOWN LUG IS AT RBL 26;[02] REMOVED DAMAGED SECTION OF UPPER CHORD I.A.W SRM 53-70-51-2SDR AALA202310064507Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION UPPER CHORD OF FLOORBEAM LOCATED AT BS 986.5, LBL 45. REPAIRED CHORD PER SRM 53-70-51-2R, REPAIR 6 ALTERNATIVE 4SDR AALA202310034058Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR BEAM UPPER CHORD LOCATED AT BS 927, RBL 51. REPAIRED FLOOR BEAM UPPER CHORD PER SRM 53-70-51-2R REPAIR 4 AND EA 347898.SDR DALA2023092607941Unknown · unknownSHIP 0668 IN REFERENCE TO NRC. 00430 PREVIOUS REPAIR WAS FOUND ON FLOOR BEAM STA 1640 BTW RBL 15 TO LBL 41 AT W4 AREA (CPAX). CORRECTIVE ACTION: SUMMARY OF NRC 00540: FLOOR BEAM STA 1640 BTW RBL 15 TO LBL 41 AT W4 AREA (CPAX) WAS REPAIRED PER B757-200 SRM. (29SDR SCNA20240309097Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT WET AREA BS947 LBL4 TO RBL9 WL208. REMOVED & REPLACED THE DAMAGED T-CHORD & 1 EA ANGLE AND INSTALLED ALL THE REPAIR PARTS AT AFT WET AREA BS 947.5 LBL 4 - RBL 9 W/L 208 IAW SRM 53-70-51-2R-5 REPAIR 5SDR SCNA20240309091Floorbeam · corrodedCORROSION ON 987 FLOOR BEAM AT AFT WET AREA LBL44 TO RBL44 WL208. AIRCRAFT ARRIVED WITH CORROSION DAMAGE ON A PREVIOUS REPAIR THAT WAS ACCOMPLISHED TO THE TOP OF BS 987 FLOOR BEAM. FLOOR BEAM IS REPAIRABLE BY REPLACEMENT DUE TO NO ALLOWABLE DAMAGE FOR BS 987 FSDR AALA202309261496Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 64 AND FR 68 AT -Y464.8. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR AALA202309269576Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 64 AND FR 66 AT +Y1292. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR SWAA2023102303253Floorbeam · corrodedMAIN CABIN AFT WET AREA CORROSION AT FLOOR BEAM FASTENER HOLE STA 986.5 LBL 45'<[01] REMOVED CORROSION AT MAIN CABIN AFT WET AREA STA 986.5 AND LBL 45' REF SRM 51-10-02-0G-0;PERFORMED UT THICKNESS INSP AT REWORKED AREA; IAW B 737 NDT PART 4 51-00-00 PROC 3. MISDR SWAA2023102303264Floorbeam · corrodedMAIN CABIN AFT WET AREA CORROSION AT FLOOR BEAM FASTENER HOLE STA 986.5 RBL 45'<[01] REMOVED CORROSION AT MAIN CABIN AFT WET AREA STA 986.5 AND RBL 45' REF SRM 51-10-02-0G-0PERFORMED UT THICKNESS INSP AT REWORKED AREA; IAW B 737 NDT PART 4 51-00-00 PROC 3. MINSDR REXA2022120101003Floorbeam · corroded"FOUND CORROSION ON R/H 280 CROSSBEAM OUT OF LIMITS NO ALLOWABLE LIMITS GIVEN. REQUIRES REPLACEMENT REMOVED RH FS280 CROSSBEAM IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, AND 51-42-22-001-001-A01. INSTALLED RT FS280 CROSSBEAM PN CC670-34094JP-2S IAW SRSDR SWAA2023102402664Floorbeam · corrodedCORROSION ON 986 FLOOR BEAM AT AFT WET AREA RBL43 WL208.<[01] REPAIRED IAW SRM 53-70-51-2R-6; REPAIR 6; FIG 205;<BR>FLOOR BEAM BS986; RBL43; WL208;[02] VERIFIED CORRECTIVE ACTION COMPLETE
Back to JASC 5315