Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023110803310Floorbeam · corrodedFWD CABIN FLOOR SUPPORT STRUCTURE HAS CORROSION LOC. FR 16, +Y 1 300. () FWD CABIN FLOOR SUPPORT FOUND DAMAGE OUT OF LIMITS, REMOVED, REP LACED FLOOR SUPPORT P/N D5311281300251 BTCH 0003979250 IAW SRM 5 1-42-11.SDR COEA2023122805801Floorbeam · corrodedWO 248415 NR 100036 HEAVY CHECK COE/MAJOR REPAIR: INTERNAL FUSELAGE FLOORBEAM 28B HAS LEVEL 2 CORROSION BETWEEN L/H AND R/H INBOARD SEAT TRACKS. CORRECTIVE ACTION: REPLACED FLOORBEAM PER ATR72 SRM 51-25-01 AND 51-25-04.SDR F3LA2023111300208Floorbeam · corrodedREFERENCE NR 5001273924-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. FOUND CORROSION ON FLOOR BEAM Y1292 FR 66 REPLACEMENT REQUIRED AS PER SRM 51-72-11 REV. 38. REPLACED FLOOR BEAM Y1292 AT FR66 AS PER SRM 51-72-11-911-001 REV 38. MX ACSDR F3LA2023111000202Floorbeam · corrodedREFERENCE NR 50012739733-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. FOUND FLOOR BEAM Y-1162.5 FR 68-69 CORRODED REPLACEMENT REQUIRED AS PER SRM 53-41-14-283-009 REV. 38. REPLACED FLOOR BEAM Y-1162.5 AT FR68-69 AS PER SRM 51-72-11-911-0SDR AALA202311099586Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT PASSENGER CABIN FLOOR BEAM UPPER CHORD LOCATED AT BS 947, RBL 6. REPAIRED FLOOR BEAM CHORD PER SRM 53-00-51-2R PROCEDURE 1.SDR SWAA2023121115793Floorbeam · corrodedAFT WET AREA - CORROSION AT FLOOR BEAM BS 986.5 RBL 43 WL 208 (MARKED)<[01] REMOVED NUT PLATE AND FOUND CORROSION AT FLOOR BEAM AT BS 986; RBL 43; WL 208. REMOVED CORROSION WITH NEXT MEASUREMENTS L:1.20' W: 1' D: .060' AND FOUND FLOOR BEAM OUT LIMITS PER SRM 5SDR VNAA202311230005Floorbeam · crackedCRACKED CENTER COCKPIT FLOOR BEAM RBL12 @ FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE BELOW FLIGHT COMPARTMENT SDR SWAA2023112415296Floorbeam · corrodedCORROSION ON BS 986 FLOORBEAM RBL 46 WL 208<[01] REPAIRED 986 FLOOR BEAM RBL 46 WL 208 IAW SRM 53-70-51-2R-6 REPAIR 6;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023112415295Floorbeam · corrodedCORROSION ON BS 986 FLOORBEAM LBL 46 WL 208<[01] REPAIRED 986 FLOOR BEAM LBL 46 WL 208 IAW SRM 53-70-51-2R-6 REPAIR 6;[02] VERIFIED CORRECTIVE ACTION 1SDR DALA2023103008925Unknown · unknownSHIP 3129 MACHINE FLOOR BEAM -Y1292 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED PER ER/A # 611875-14. (0037804)SDR DALA2023103008888Unknown · unknownSHIP 1807 ERA 612861-14 ISSUED FOR REPAIR AND BLIND RIVET INSTL TO FLOOR B EAM STIFFENER AT STA 246, LBL 40. FOLLOW ON ACTION IS REQUIRED. CORRECTIVE ACTION: ACCOMPLISH ERA 612861-14 SECTION II INSPECTIONS EVERY 1500 CYCLE S AFTER SECTION 1, OR EVERY 456 DAYS,SDR CALA2023110603291Floorbeam · corroded(B737-06-3-0049) MAIN CABIN STA 986 LBL 30-LBL 35 HAS SEVERAL AREAS OF CORROSIONSDR DALA2023102608811Unknown · unknown(LOG 00338800 WET AREA FLOOR BEAM STA 947 RBL & LBL 50 CORROSION AT LAV MOUNT. REPAIRED FLOOR BEAM STA 947 LBL & RBL 50 IAW BOEING 737-800 SRM 53-70-51-2R REPAIR 5 & DELTA ER/A 613051-14.SDR REXA2024011600075Floorbeam · corrodedTOP OF FLOOR CROSS BEAM AT FS 349.00 IS CORRODED BETWEEN LBL 9 AND RBL9. REMOVED PACKER P/N: SH670-32167-3 AT FS 349 RBL9 IAW CRJ-900 SRM 51-42-06-001-001-A01. INSTALLED NEW SERVICEABLE PACKER P/N: SH670-32167-3 AT FS 349 RBL9 IAW CRJ-900 SRM 51-42-06-001-001SDR SWAA2023112814461Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED BS 986.5 LBL 42 WL 208.1 AT AFT GALLEY AREA 2023-661415<[01] TOOL USED: ULTRASONIC THICKNESS GAGE; P/N: 45MG; S/N: 130060401 DUE DATE: 20-MAR-24;[02] EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N: 200053402 AND DUE DATE: 24-SDR SWAA2023112014390Nut Plate · corrodedAFT CARGO STA.727D+4 LBL24-RBL2; CORROSION ON FLOORBOARD NUT-PLATE STRAP.<[01] REMOVED CORROSION PER SRM 53-00-53-1A-2. (REMAINING THICKNESS 0.066'). STRAP IS OUT OF LIMITS SRM 53-00-53-1A-2 AND SRM 51-10-02.;[02] REMOVED AND REPLACED FLOORBOARD STRAP PER SRM SDR SWAA2023112014391Nut Plate · corrodedAFT CARGO STA.767+4 LBL24-RBL24; CORROSION ON FLOORBOARD NUT-PLATE STRAP.<[01] REMOVED CORROSION FROM AREA PER SRM 53-00-53-1A-2. (REMAINING THICKNESS 0.058'). STRAP OUT OF LIMITS PER SRM 53-00-53-1A-2 AND SRM 51-10-02.;[02] REMOVED AND REPLACED FLOORBOARD STRSDR REXA2024103101278Floorbeam · corrodedF.S. 280 FWD J ANGLE IS CORRODED. REMOVED FWD J ANGLE IAW CRJ900 SRM 51-42-21-001-001-A01 AND 51-42-06-001-001-A01 INSTALLED NEW SERVICEABLE FWD J ANGLE ON FS 280 CROSSBEAMS BETWEEN LBL 12 AND RBL 12 IAW CRJ 900 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-0SDR REXA2024103101277Floorbeam · crackedF.S. 280 O/B CLIP IS CRACKED AT RBL11. REMOVED CRACKED ANGLE IAW CRJ 900 SRM 51-42-21-001-001-A01. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE ANGLE P/N CC670-34099-2 COMMON TO RBL 12 INTERCOSTAL AND FS 280 CROSSBEAM IAW CRJ 900 SRM 51-40-11-001-001-A01 ANSDR REXA2024103101276Floorbeam · crackedR/H F.S. 280 BEAM APPEARS TO BE CRACKED BETWEEN RBL 12 TO RBL 16 AND AT RBL 36. LOCATED AND DRILLED NEW FS 280 RH CROSSBEAM PN: CC670-34094JP-2S IAW CRJ900 SRM 51-40-11-001-001-A01 AND SB 670BA-53-041 REV M INSTALLED NEW SERVICEABLE R/H FS 280 CROSSBEAM IAW CSDR SWAA2023113013591Floorbeam · corrodedCORROSION ON FLOOR BEAM AT FASTENER HOLE 986.5 LBL 43<[01] BLENDED CORROSION ON UPPER FLANGE OF FLOOR BEAM 986.5 AT LBL 43? PER SRM 51-10-02. REMOVED .016? OF MATERIAL. REMAINING THICKNESS IS .134?. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-70-51-1A-1.;[02] VSDR AALA202311022596Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON UPPER CHORD OF FLOOR BEAM LOCATED AT BS 947.5, RBL 48. REPLACED T-CHORD PER SRM 53-70-51-2R-5.SDR SWAA2023113013077Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS986.5 AT RBL43 AND WL208.1 AT AFT GALLEY AREA 2023-650085<[01] TOOL USED EDDY CURRENT EQUIPMENT PN:NORTEC 600D; SN: 60007161486; DUE DATE: 20-JUL-24;[02] EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N: 210138503 AND DUE DATE: SDR SWAA2023113013079Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS947.5 BETWEEN RBL49 TO RBL53 AND WL208.1 AT AFT GALLEY AREA 2023-650083<[01] PERFORMED PERMANENT REPAIR FLOOR BEAM UPPER CHORD BS947.5 AND BETWEEN RBL 2 TO RBL 60 AFT GALLEY AREA. (-1)T CHORD 1E/A MATERIAL USED: AND10136-3006; POSDR DALA2023102008648Unknown · unknownSHIP 3125 FLOOR BEAM CORRODED 10" I/B OF R2 AFT GIRT BAR FITTING. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A319 SRM 51-42-11. (0026267)SDR DALA2023102008646Floorbeam · unknownSHIP 3125 FLOOR BEAM CORRODED -Y765 FR 68. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y765 PER A319 SRM 51-42-11. (0026255).SDR SIMA20231018001Floorbeam · corrodedFWD FUSELAGE FR 17 FLOOR CROSSBEAM HAS CORROSION ON RH SIDE. (LEVEL 2 CORROSION) (MAJOR REPAIR)-C/A-ACCOMPLISHED REPAIR OF FR 17 CROSSBEAM IAW EMB 170 SRM 53-00-10 AND ERS-EJ-5300-4901SDR DALA2023110509105Unknown · unknownSHIP 1807 CABIN FLOOR STRUCTURE SECTION 41. FRONT FACE OF FLOOR BEAM STA 246 WITH STIFFENER BROKEN LBL 40. CORRECTIVE ACTION: CABIN FLOOR STRUCTURE SECTION 41 FRONT FACE OF FLOOR BEAM STA 246 LBL 40. STIFFENER WAS REPLACED I.A.W B 767-400 ER/A 612861- 14 (0044SDR REXA2024110101352Floorbeam · corrodedLEFT, RIGHT, AND CENTER 280 CROSSBEAM CORRODED AT TOP CAP AS MARKED. REMOVED CORRODED F.S. 280 CROSSBEAM AND INSTALLED A NEW F.S. 280 CROSSBEAM P/N CC670-34175-7. IAW CRJ-700 SRM 53-11-41-201-003-A01.SDR REXA2024103001219Floorbeam · corrodedR/H FITTING FOR THIRD CREW FOOT REST ON COCKPIT FLOOR BEAM CRACKED REPAIRED PER REO 690-53-11-1626SDR SWAA2023112911771Floorbeam · corrodedCORROSION AT FWD CABIN WET AREA FLOOR SUPPORT BEAM UPPER CAP LBL 15 STA 312 MKD DOT<[01] ACCOMPLISHED PERMANENT REPAIR PARTS AT STA 312 UPPER CHORD BETWEEN LBL 4 AND LBL 25.5 REF B737-700 SRM 53-10-51-2R-15 TABLE 201 FIG 204.;[02] RII-VERIFIED PERMANENT REPAIRSDR JJBA20231030048Unknown · unknownIN LH ENGINE PYLON, LH PRECOOLER FWD STRUCTURE BRACKET IS CRACKED. BRACKET REPLACEDSDR DALA2023102308674Unknown · unknown(LOG 0021857) AFT WET AREA STA 986 FLOOR BEAM REPAIR CAP IS CORRODED. REMOVED & REPLACED OUT OF LIMITS CORRODED FLOOR BEAM T-CHORD CAP IAW BOEING SRM 53-70-51-2R REPAIR 4.SDR CALA2023101903115Floorbeam · corroded(SUPPORT TASK) MAIN CABIN FLOOR BEAM STA 986 RBL29 PREVIOUS TCAP REPAIR CORRODED ON UPPER SURFACE TRANSCRIBED FROM HAECO N/R 928 4543SDR REXA2024110101351Floorbeam · crackedFS 280 CROSSBEAM FLOOR PANEL SUPPORT ANGLE (J ANGLE) IS CRACKED ON BOTH R/H AND L/H SIDE, REQUIRES REPLACEMENT. LOCATED AND DRILLED REPLACEMENT FLOOR CHANNEL SUPPORT PN CC670-33292-13 IAW CRJ 700 SRM 51-40-11-001-001-A01. REF. BARCODE IDENTIFIER HN110081 FOR ISDR AALA202310165463Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOOR BEAM BETWEEN FR 12 AND FR 24 AT +Y765. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR DALA2023101608457Unknown · unknownCRACK ON PAN IN BEAM 2 AND ON PAN BTW BEAM 7 TO 8 ON AFT SIDE OF PASSENGER DOOR L1. SUMMARY OF NRC 00095: PAN IN BEAM 2 AND PAN BTW BEAM 7 TO 8 AT AFT SIDE OF PASSENGER DOOR L1 WERE REPAIRED PER B717-200 SRM 52-10-02-2R REPAIR 3. (LP #0018804)SDR CALA2023101603087Floorbeam · corrodedCABIN - STA 303 LBL46 - LBL54 FLOOR BEAM FOUND CORROSION TRANSFER REF. NON-ROUTINE HX NRC WO.2254051. CABIN STA 303 FLOOR BEAM LBL 5" TO LBL 64" UPPER CHORD REPAIRED AS PER EC/RA 5315-01202 REV-. ATTACHED FORM 44-0008 ITEM 1 TO ITEM 33 ACCOMPLISHED. (CATEGORYSDR CALA2023101603074Floorbeam · corrodedCABIN - STA 325 LBL27 - LBL54 FLOOR BEAM FOUND CORROSION TRANSFER REF. NON-ROUTINE HX NRC WO.2253976. CABIN STA 325 FLOOR BEAM LBL 10" TO LBL 61.5" FLOOR BEAM UPPER CHORD REPAIRED AS PER EC/RA 5310-08211 REV-. ATTACHED FORM 44-0008 ITEM 1 TO ITEM 32 ACCOMPLISSDR SWAA2023110710262Floorbeam · corrodedCORROSION FLOOR BEAM BS 312 AND LBL 15 APROX AT FWD GALLEY AREA 2023-635502<[01] TOOL USED: ULTRASONIC THICKNESS GAUGE; PN: 45MG; SN: 221861811; DUE DATE: 08-NOV-23;[02] PERFORMED PERMANENT REPAIR ON FLOOR BEAM LOC. BS 312 BTW LBL LBL30 TO BL0 AT FWD GALLEY ARSDR SIMA20231011003Floorbeam · corrodedSSI 53-10-027 - FWD GALLEY FLOOR SUPPORT CORRODED ADJACENT TO RH FLOOR BEAM AT FR 12. (LEVEL 2 CORROSION) -C/A- RAR THE FWD GALLEY FLOOR SUPPORT ADJACENT TO RH FLOOR BEAM AT FR 12 IAW EMB 170 SRM 51-40-08.SDR AALA202310275797Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION AFT CABIN FLOOR BEAM BETWEEN FR 68 AND FR 69 AT +Y1162.5. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR AALA202310277980Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION AFT CABIN FLOOR BEAM AT FR 68 AND +Y765. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR ASAA2023101045866Floorbeam · corrodedAFT CABIN FLOOR SUPORT BEAM AT L4 DOOR AT FR 68 HAS CORROSION T NUTPLATE LOCATION GROUNDED - YES. REMOVED CORROSION IAW A321 SRM 53-41-14-283-002. ORIG MAT .071, REMAINING MAT .031. MAT LOSS OF .040 IS BEYOND ALLOWABLE LIMITS. ALLOWED 25% MAT. LOSS REPAIRED ARSDR DALA2023101108337Unknown · unknownSHIP 3119 CORROSION FLOOR BEAM -Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA AS PER A319 SRM 51-42-11 AND SRM 51-72-11. (0011074)SDR VNA202310092003Floorbeam · corrodedFOUND CORROSION ON RH FS 280 FLOOR BEAM PN# CC670-34094-2.SDR VNA2023F00003Floorbeam · corrodedFOUND CORROSION ON RH FS 280 FLOOR BEAM PN# CC670-34094-2.SDR VNA2023F00002Floorbeam · corrodedFOUND CORROSION ON FS 280 L/H FLOOR BEAM ON FWD PN# CC670-34094-1.SDR VNAA202311260008Floorbeam · corrodedAFTER FLOOR SUPPORT LBL 11 TO RBL 11 FS280 REMOVAL, CORROSION ON FLOOR STRUCTURE CROSSBEAM AT FS280.00. FLOOR STRUCTURE CROSSBEAM AT FS280.00 WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01SDR SWAA2023110808771Floorbeam · crackedCRACK ANGLE FLOOR STRUCTURE BS695 AND RBL24.75 LOWER POSITION CENTER SECTION 2023-637667<[01] REPLACED ANGLE LOC. FLOOR STRUCTURE BS695 AND RBL24.75 LOWER POSITION CENTER SECTION IAW B737-700 SRM 51-40-02; SRM 51-10-02 AND DWG 111A6000 SHEET: 304 REV:-<BR>SEE
Back to JASC 5315