JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020122404251Stiffener · crackedCRACK INDICATION FOUND AT CWB FRONT SPAR VERTICAL STRINGER POSITION 32 AT FRAME 36 Y254. CORRECTIVE ACTION: REPAIRED PER ER/A 588680-14AD REV ORIGINAL. OK FOR SERVICE.SDR DALA2020122404250Stiffener · crackedCRACK INDICATION FOUND AT CWB FRONT SPAR VERTICAL STRINGER POSITION 5 AT FRAME 36 Y-765. CORRECTIVE ACTION: REPAIRED PER ER/A 588680-14AD REV O. OK FOR SERVICE.SDR DALA2020122404249Stiffener · crackedCRACK INDICATION FOUND AT CWB FRONT SPAR VERTICAL STRINGER POSITION 5 AT FRAME 36 Y-765. CORRECTIVE ACTION: REPAIRED PER ER/A 588680-14AD REV ORIGINAL. OK FOR SERVICE.SDR SWIA202056326Angle · crackedOBLIQUE ANGLE CRACKED AT FS 621.00 TO FS 625.00 RBL 45 STRGR 14 WL 97.5 (C-CHECK) RO 2/17/2021. TECH REPLACED OBLIQUE ANGLE AT RBL 45 BETWEEN FS 621.00-FS 625.00 IAW CRJ 200 SRM 51-40-11, 51-25-00 AND 51-42-21.SDR SWIA202056032Intercostal · corrodedINTERCOSTAL AT STRG20R IS CORRODED BETWEEN FS319.70 & FS333.00 (C-CHECK) RO 2/6/2021 REPLACED INTERCOSTAL AT STRINGER 20R BETWEEN FS 319.70 AND FS 333.00 AS PER DWG SH670-31950 REV Y AND CRJ 700 SRM 51-42-06-001-001-A01. SKYWEST TASK CARD 51-900-1003-SKY CSDR SIMA20201223003Floor Support · corrodedLT OMEGA BEAM AT FRAME 20 PREVIOUS REPAIR IS CORRODED. C/A: REACCOMPLISHED REPAIR ON LT OMEGA BEAM AT FRAME 20, IAW EMB 145 SRM 53-00-10RE.SDR DALA2020122704267Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRUCTURE ANGLE ON LBL 52 FROM STA 1672 TO 1680 AT PAX CABIN. MAINTENANCE REPLACED ANGLE.SDR DALA2020122704264Anchor Fitting · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON ATTACHING ANCHORS NET ON RT SIDE PANEL ON STA 1380 AT AFT CARGO COMPARTMENT AND REPLACED.SDR DALA2020122704263Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON STRINGER SUPPORT ON S-28R STA 1380 AT AFT CARGO COMPARTMENT. STRINGER REPLACED.SDR DALA2020122404248Web · corrodedCORROSION INTERNAL STRUCTURE WEB LOCATED FROM FR 56 TO FR 57 AND STR 38R IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: REPAIRED PER ER/A 589020-14. OK FOR SERVICE.SDR DALA2020122304221Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR SUPPORT AT STA 418 RBL 24.75 (W1). FLOOR SUPPORT REPLACED PER SRM.SDR SWAA2021052143063Floor Support · corrodedCENTER FLOOR SUPPORT UNDER PANEL 211AF AT FLIGHT COMPARTMENT ENTRANCE STA 259.5 TO 270 OBL CORRODED. / REMOVED AND REPLACED SUPPORT PER SRM 51-40-02.SDR SWIA202056385Bracket · crackedFS 280 2 EA ANGLE BRACKETS AT RBL 9 ARE CRACKED. (C-CHECK) RO 2/21/2021. REMOVED DAMAGED BRACKETS AND INSTALLED SERVICEABLE BRACKETS IAW CRJ 200 SRM 51-42-21.SDR SWIA202056378Floor Support · corrodedLEFT SIDE FLOOR SUPPORT STRUCTURE HAS MULTIPLE AREAS OF CORROSION FS 559+80 TO FS 621, LBL42.90. (C-CHECK) RO 2/21/2021. REPAIRED LEFT SIDE FLOOR STRUCTURE AT FS 559+80 TO FS 621 LBL 42.90 IAW REO 601R-53-61-690 REV D DATED 29 SEP 05. REFERENCE CONTINUATIOSDR SWIA202056372Floor Support · corrodedRIGHT FLOOR SILL MEMBER FS409+128 TO FS 559 HAS MULTIPLE AREAS OF CORROSION (C-CHECK) RO 2/21/2021. REPAIRED RIGHT FLOOR SILL MEMBER FS409+128 TO FS 559 AS REQUIRED IAW REO 601R-53-41-666 REV C DATED 2012-11-06. SEE ATTACHED CONTINUATION CARD FOR WORK PERFSDR IPXA2021011964653Landing · crackedINSPECTION TYPE: C3 RT UPPER HORIZ STAB LANDING SUPPORT CRACK AT STA 2122. REMOVED, FABRICATED AND REPLACED CRACKED LANDING SUPPORT, IAW SRM 51-33-01 AND 51-35-01 (MINOR).SDR SIMA20201222002Floor Support · corrodedCARGO DOOR CUTOUT STRUCTURE LOWER FLOOR SILL CORRODED. LEVEL 1 CORROSION. C/A: REMOVED AND REPLACED THE CARGO DOOR CUTOUT STRUCTURE LOWER FLOOR SILL, IAW EMB 145 SRM 51-40-02.SDR HNAA2021011400023Door Sill · corrodedSSI 53-30-48 CARGO DOOR CUTOUT CENTER SILL HAS CORROSION. R & R CARGO DOOR CUTOUT LOWER SILL, IAW EMB-145 SRM 51-40-02.SDR REXA2021011200872Floor Support · corrodedRT FLOOR SILL CORRODED BETWEEN FS 310.00 AND FS 319.70. REPLACE RT FLOOR SILL BETWEEN FS 310-319.00, IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 51-42-13-001-001-A01 & 51-42-12-001-001-A01.SDR REXA2021011200866Support Angle · bentFLOOR BEAM BENT AND RIVETS BROKEN THAT MOUNT BEAM BETWEEN FS 333.00 AND FS 349.00 OUTBOARD OF LBL 27.00. REMOVED AND REPLACED SUPPORT ANGLE BETWEEN FS 333.00 & FS 349.00, IAW CRJ900 SRM 51-40-11-001-001-A01 AND 51-42-13-001-001-A01. P/N SH670-33333-1 AND SH6SDR SWIA202056374Floor Support · corrodedLEFT FLOOR SILL HAS MULTIPLE CORROSION AREAS FS409+128 TO FS559 (C-CHECK) RO 2/21/2021 CORROSION WAS REMOVED AND TREATED IAW BOMBARDIER REO 601R-53-41-666 REV C DATED 2012-11-06. FORM 337 AND MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED AND ATTACHED. SDR SWIA202056026Door Sill · corrodedAFT CARGO DOOR SILL HAS CORROSION (MARDKED WITH RED) (C-CHECK) RO 2/6/2021 REPLACED AFT CARGO DOOR LOWER SILL WITH NEW. REF 0 SRM 51-42-06-001-001-A01 REV 38 JUL 25/2020 CRJ-700 SRM 51-42-13-001-001-A01 REV 38 JUL 25/2020 CRJ-700 SRM 51-42-21-001-001-A01 RSDR SWIA202056025Floor Support · corrodedAFT CARGO FS 985-1000 L/H FLOOR SILL IS CORRODED (MARKED WITH RED) (C-CHECK) RO 2/6/2021 CUT AWAY DAMAGE AREA, FABRICATED AND INS TALLED REPAIR PARTS REF REO670-53-61-1801, REV--, DATED 2021-01-08 AND DWG MM670-35085 REV-L. COMPLIED WITH 51-900-1002-SKYSDR SWIA202056024Floor Support · corrodedAFT CARGO FS1015-1030 R/H FLOOR SILL IS CORRODED (MARKED WITH RED) (C-CHECK) RO 2/6/2021 REMOVED CORROSION ON RH FLOOR SILL BETWEEN FS1015 AND FS1030. REF CRJ700 SRM 51-21-06-001-001-A01. NDT DEFECT FREE. EVAL OF MATERIAL REMOVED FOUND TO BE OUT OF LIMISDR SWIA202056021Intercostal · corroded*INTERCOSTAL AT STGR26R AND FS349.00 €“ FS364.00 IS CORRODED ALONG THE LOWER FLANGE. (MARKED) (C-CHECK) RO 2/6/2021 REPLACED CORRODED STRUCTURE AT 26R AND FS 349.00 TO 364.00 AS PER CRJ 700 SRM 51-42-06-001-001-A01 AND DRAWING SH670-31350 REV A. SKYWEST TSDR SWIA202056020Intercostal · corroded*INTERCOSTAL BETWEEN STGR27 - STGR26R AND FS349.00 €“ FS364.00 IS CORRODED ALONG THE LOWER FLANGE. (MARKED) (C-CHECK) RO 2/6/2021 REPLACED INTERCOSTAL BETWEEN STRINGER 27 AND 26R AT FS 349.00 - FS 364.00 AS PER CRJ 700 SRM 51-42-06-001-001-A01 SRM 51-42-2SDR SWIA202056019Intercostal · corroded*INTERCOSTAL BETWEEN STGR26L - STGR27 AND FS349.00 €“ FS364.00 IS CORRODED ALONG THE LOWER FLANGE. (MARKED) (C-CHECK) RO 2/6/2021 REPLACED INTERCOSTAL BETWEEN STRINGER 26L AND 27 AT FS 349.00 - FS 364.00 AS PER CRJ 700 SRM 51-42-06-001-001-A01, SRM 51-42-SDR SIMA20201221002Support · corrodedTOILET WASTE VALVE SUPPORT EXTERIOR HAS CORROSION. C/A: REMOVED AND REPLACED THE TOILET WASTE VALVE SUPPORT, IAW EMB 145 SRM 51-40-02.SDR AALA202101119028Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED SHEAR PLATE AT STR 23R BETWEEN FR 69 AND FR 70 AT AFT GALLEY AREA MEASURING L=1.430 INCHES. REPLACED SHEAR PLATE, PER SRM 51-42-11-801 AND DRAWING D53474180.SDR AALA202101069004Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN SHEAR PLATE AT STR 23L BETWEEN FR 69 AND FR 70 MEASURING L= 0.825 INCHES. REPLACED SHEAR PLATE, PER SRM 51-42-11-801 AND DRAWING D53474180.SDR AALA202012289004Support · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORROSION ON SILL AT FR 68 AND STR 23R IN AFT GALLEY AREA, MEASURING L=0.885 INCH, W=0.711 INCH, D=0.057 INCH. PERFORMED PERMANENT REPAIR ON FR 68 AT LEVEL STR 23R, IAW A319 SRM 53-41-14-300-001 PRINCIPLE 7 FIGURE 001 PAGESDR AALA202012249001Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON AFT LEFT HAND PASSENGER DOOR CUT OUT LOWER SILL CENTER SHAPE FITTING BETWEEN FR 66 AND FR 68 AT S23L. REPLACED SHAPE FITTING, PER SRM 51-72-11 AND 51-42-11.SDR DALA2020122304211Angle · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON ANGLES STA 1701 AND STA 1718 AND RBL 16.39 TO RBL 45.50 AT PASSENGER CABIN. REPLACED ANGLES.SDR SWAA2021072134757Angle · crackedCRACK ANGLE LOCATED BETWEEN BS 380 AND BS 400 BL 0 AT PASSENGER CABIN / REMOVED ANGLE LOC. BTW BS380 AND BS400 BL0 AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; DUE TO NOT FOUND ALLOWABLE DAMAGE ON SRM B737-700; ANGLE MUST BE REPLACED. REPLACED ANGLE LOC. BTW SDR IPXA2021021065529Support Angle · corrodedINSPECTION TYPE:C3AFT CARGO BULKHEAD LWR LINER SUPPORT ANGLE CORRODED AT STA 1967 FROM X=24 TO X=-24.REMOVED,FABRICATED AND REPLACED CORRODED AFT CARGO LWR SUPPORT ANGLE IAW SRM 51-35-01 AND 51-21-01 (MINOR).SDR SWIA202056012Fitting · corrodedLH JACK FITTING SUPPORT " FWD JACKING FITTING" BETWEEN FS265.00 AND FS280.00 IS CORRODED. FLAGGED (C-CHECK) RO 2/6/2021 REMOVED AND REPLACED LH INTERCOSTAL SUPPORT P/N CC670-32179-1 AT FS265-FS280 WITH NEW FASTENERS. REF: DWG CC670-32050 REV. NC, CRJ 700SDR IPXA2021011964635Intercostal · crackedINSPECTION TYPE: C3 MAIN CARGO BRACKET (INTERCOSTAL)CRACK BETWEEN STA 1781 TO STA 1801 LONG 11R. REMOVED AND REPLACED CRACKED BRACKET (INTERCOSTAL), IAW SRM 51-33-01 AND 51-35-01 (MINOR).SDR AALA202101069002Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON AFT GALLERY AREA LOWER SILL FR 68 STR 23L MEASURING 0.500 X 0.312 X 0.018 INCHES. PERFORMED PERMANENT REPAIR REINFORCEMENT ANGLES, PER SRM 53-14-300-001 FIG 001 SHEET 03 PRINCIPLE 5.SDR AALA202012299002Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORROSION ON CENTER FITTING BETWEEN FR 66 AND FR 68 AND STR 23L, MEASURING L: 1.782 INCH, W: 0.515 INCH, D: 0.088 INCH. REPLACED CENTER FITTING, IAW SRM A321 51-72-11-911-001, SRM A321 51-42-801 & DWG D53480505.SDR DALA2020122304234Floor Support · corrodedCORROSION FLOOR BEAM -Y794.3 BETWEEN FR 74 TO FR 77 AT AFT GALLEY AREA. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR LOCATED ON FLOOR BEAM AT AFT GALLEY AREA, AS PER ERA NR 588996-14 REV 0 AND REV ORIGINAL.SDR AALA202012219037Tube · debondedAIRCRAFT WAS GROUNDED. LOUD SQUEAL FROM R2 WINDOW AT 16,000 FT, FLIGHT DIVERTED TO BOS; ON DESCENT, SQUEAL STOPPED AT 8500 FT. FOUND CONDENSATION TUBE DISBONDED FROM U-CHANNEL. REBONDED TUBE IAW AMM 56-11-11.SDR AALA202012219019Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN SHEAR PLATE AT STR 23R BETWEEN FR 69 AND FR 70, MEASURING L=1.080 IN. REPLACED SHEAR PLATE WITH NEW, IAW SRM 51-72-11-911-001 AND 51-42-11-801 AND DRAWING D53479180.SDR SWAA2021080338158Strap · damagedCARGO FLOOR STRAP DAMAGED IN AFT CARGO PIT FWD SIDE OF DOOR OPENLY / R&R FWD LOWER CARGO PLATE ON FLOOR ON 453A2611-1 RDW SRM 51-40-02 & 53-00-05SDR IPXA2021011964656Support Rod · crackedINSPECTION TYPE: IN FWD CARGO CEILING, MAIN CABIN FLOOR BEAM SUPPORT ROD CRACK AT STA 919. REMOVED AND REPLACED CRACKED SUPPORT ROD AT FWD CARGO CEILING, IAW SRM 51-33-01 PARA 8 (MINOR).SDR AALA202101069001Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON RIGHT HAND AFT PASSENGER DOOR CUT OUT LOWER SILL AT FR 68 AND S23R. REPAIRED LOWER SILL, PER SRM 51-41-14-300-001 FIGURE 001 SHEET 03.SDR YENA2020122300630Shear Plate · crackedDURING HEAVY MAINTENANCE, REF JB EC A20-817-01, FUSELAGE CENTER KELL BEAM FR 42FH SHEAR PLATE WEB CRACKED, REF JB EC A20-817-01 & FAS EA 20047 REV IR & AIRBUS RDAS 8060800/005/2020 ISSUE B. PERMANENT REPAIR ACCOMPLISHED UNDER WO NR 1080180. CLASSIFIED AS MAJSDR DALA2020122304209Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SUPPORT TEE STA 1040, BETWEEN LBL 6 TO RBL 6 AT KEEL BEAM AREA. C/W ERA 589104-14.SDR DALA2020122304208Web · corrodedDURING INSPECTION FOUND CORROSION LEVEL 2 ON WEB STA 1060 AND 1080 BETWEEN S-16R S-17R AT PASSENGER CABIN WAS REPLACED, PER ERA.SDR AALA202012229018Striker · chafedAIRCRAFT IN BASE MAINTENANCE. FOUND PANEL 192DR OUTBOARD LATCH HAS CHAFED THROUGH STRIKER PLATE. REPAIRED LOWER CHORD, PER B737 SRM 53-40-71-2R REPAIR 3.SDR SWIA202056740Floor Support · corroded*FLOOR SUPPORT, FS1051.30 €“ RBL40.0, IS CORRODED. (MARKED) (C-CHECK) RO 3/8/2021 REPAIRED FS1051 FLOOR BEAM AT RBL40 IAW CRJ700 REO 670-53-61-1805 REV-- 2021-02-03, CRJ-700 SRM 51-42-06-001-001-A01, CRJ-700 SRM 51-42-21-001-001-A01, CRJ700SRM 51-23-00-
Back to JASC 5320