JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202056739Floor Support · gouged*RBL9 FLOOR BEAM OUTBOARD FLANGE GOUGED, FS863.00 €“ FS953.00. (MARKED) (C-CHECK) RO 3/8/2021 REPAIRED DAMAGED FLOOR BEAM AT RBL9 FS 855-885 IAW CRJ700 SRM 53-00-41-201-001-A01 FIG 53-00-41-991-830. COMPLIED WITH 51-900-1002-SKY ( CL600-2C10), AND M-SDR SWIA202056738Floor Support · corroded*RIGHT HAND FLOOR SILL IS CORRODED AT THE FORWARD END FS969.00 €“ FS985.00. (MARKED) (C-CHECK) RO 3/8/2021 REMOVED AND INSTALLED NEW RH FLOOR SILL P/N SH670-31518-1 BETWEEN FS969.00 - FS985.00 REF CRJ700-SRM51-42-06-001-001-A01 AND DWG SH670-32170, REV SDR SWIA202056365Floor Support · damagedRIGHT FLOOR SILL AT APPROX FS 559+32 AND RBL 42, NUT PLATE DAMAGED AND FASTENER HOLE ELONGATED. (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED NUTPLATE AT RT FLOOR SILL AT APPROX FS 559+32 AND RBL 42 AND REAMED NUTPLATE HOLE IAW CRJ 200 SRM 51-45-00, 51-40-11.SDR SWIA202056356Floor Support · corrodedCARGO BAY RT FLOOR SILL, NUTPLATES CORRODED AT APPROX RBL 47 BETWEEN FS 589 TO FS 621. (C-CHECK) RO 2/17/2021. REMOVED DAMAGED NUTPLATES AND INSTALLED NEW NUTPLATES IAW CRJ 200 SRM 51-45-00.SDR SWIA202056334Floor Support · corrodedFLOOR BEAM AT RBL 9 HAS MINOR CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. REPAIRED AREA OF CORROSION ON FLOOR BEAM AT RBL 9 BETWEEN FS 409+128 TO FS 559 IAW REO 601R-53-41-2839 REV -- DATED 2021-01-11.SDR SWIA202056333Strap · corrodedFLOOR SUPPORT STRAP AT FS 559.00 HAS MULTIPLE SPOTS OF CORROSION FROM LBL 27 TO LBL 45 (C-CHECK) RO 2/17/2021. REMOVED AND REPLACED FLOOR SUPPORT STRAP AT FS 559.00 IAW CRJ 200 SRM 51-42-06 AND 51-42-10. PRESSURE CHECK GOOD IAW CRJ 200 AMM 21-32-00-863-801.SDR SWIA202056332Strap · corrodedFLOOR SUPPORT STRAP AT FS 559.00 HAS MULTIPLE SPOTS OF CORROSION FROM RBL 27 TO RBL 45 (C-CHECK) RO 2/17/2021. REMOVED AND REPLACE FLOOR SUPPORT STRAP AT FS 559.00 RBL 27 TO RBL 45 IAW CRJ 200 SRM 51-42-06 AND 51-42-13.SDR SWIA202056331Intercostal · corrodedINTERCOSTAL AT STGR 20L CORRODED BETWEEN FS 319.70 AND FS 349.00 (C-CHECK) RO 2/17/2021. REPLACED THE INTERCOSTAL AT STGR 21L BETWEEN FS 319.70 TO FS 349.00 IAW CRJ 200 SRM 51-40-11, 51-42-06, 51-42-21. REFERENCE ATTACHED CONTINUATION CARD FOR WORK PERFORMEDSDR SWIA202056329Floor Support · corrodedRIGHT FLOOR SILL ANGLE HAS MULTIPLE SPOTS OF CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. COMPLIED WITH BOMBARDIER REO 601R-53-41-666 REV-C DATE 2012-11-06 STEP 2.2.SDR SWIA202056310Floor Support · corrodedRH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00 +128 TO F.S. 559.00 (C-CHECK) RO 2/17/2021 REPAIRED RH FLOOR SILL FROM FS 409+128 TO FS 559 IAW REO 601R-53-41-666 REV C, DATED 2012-11-06, MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED ANDSDR SWIA202056308Floor Support · corrodedLEFT FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. REPAIRED LT FLOOR SILL FS 409+128 TO FS 559.00 IAW C REO 601R-53-41-666 REV C, DATED 2012-11-06, COMPLETED TASK CARD 51-900-1003- SKY AND FORM M-337. SDR SWIA202056303Floor Support · corrodedFLOOR BEAM AT LBL 9 HAS MINOR CORROSION FROM FS 409.00 +128 TO FS 559.00 (C-CHECK) RO 2/17/2021. REPAIRED AREA OF CORROSION AT LBL 9 BETWEEN FS 409.00+128 TO FS 559.00 IAW REO 601R-53-41-2846 REV -- DATED 2021-01-22, SKYWEST TASK CARD 51-900-1003-SKY AND FORMSDR AALA202101259007Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND L=1.225 IN LENGTH CRACK IN SHEAR PLATE AT FR 69 TO FR 70 AND STR 23R IN PASSENGER CABIN. REPLACED SHEAR PLATE, IAW A321 SRM 51-42-11-801 AND DRAWING D53474180.SDR AALA202101229009Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK ON SHEAR PLATE LOCATED BETWEEN FR 68 TO FR 70 AT LEVEL STR 23L IN PASSENGER CABIN. REPLACED SHEAR PLATE LOCATED BETWEEN FR 68 TO FR 70 AT LEVEL STR 23L IN PASSENGER CABIN, PER SRM 51-42-11-801.SDR IPXA2021011964623Intercostal · crackedINSPECTION TYPE: C3 LOWER FWD CARGO INTERCOSTAL CRACK BETWEEN STA 6-30 TO STA 6-50 AT LONG 43L. REMOVED AND REPLACED CRACKED INTERCOSTAL BETWEEN STA 6-30 TO STA 6-50 AT LONG 43L, IAW SRM 51-35-01 AND 51-33-01. (MINOR)SDR IPXA2021011964621Intercostal · crackedINSPECTION TYPE: C3 LOWER FWD CARGO INTERCOSTAL IS CRACKED BETWEEN STA 6-10 TO 6-30 LONG 43L. REMOVED AND REPLACED LOWER FWD CARGO INTERCOSTAL BETWEEN STA 6-10 TO 6-30 LONG 43L, IAW SRM 51-33-01 PG 30. (MINOR)SDR IPXA2021012064685Intercostal · crackedINSPECTION TYPE: 3C LOWER FWD CARGO INTERCOSTAL IS CRACKED BETWEEN STA 6-30 TO 6-50 AT LONGERON 43R. REMOVED AND REPLACED CRACKED LOWER FWD CARGO INTERCOSTAL BETWEEN 6-30 TO 6-50 AT LONGERON 43R, IAW MD-11 SRM 51-33-01. (MINOR)SDR SWIA202055452Floor Support · brokenFLOOR BEAM HAS BROKEN AT LBL 9, FS 559.00+48-FS 559.00+64. C-CHECK RO 1/16/2021. REMOVED AND REPLACED NEW FLOOR BEAM WEB P/N 601R31119-61 AT LBL 9 FS 559.00+48-FS 559.00 +64, REF CRJ200 SRM 51-42-06 AND DWG 601R31119 REV-H. COMPLIED WITH TASK CARD 51-900-10SDR FDEA202012183222Support · corrodedAFT CARGO COMPARTMENT: CORROSION UNDER AND AROUND HOLES FOR LOWER SIDEWALL ATTACH POINTS (BOTTOM OF PANEL) BETWEEN APPROXIMATELY STA 1900-1921, MARKED AND DOT 19. REMOVED & INSTALLED FABRICATED FLOOR SUPPORT AGA 3857, PER DWG AGA 3857 & SRM 51-35-01.SDR SWAA2021011137487Floor Support · corrodedPASSENGER CABIN, FLOOR INTERCOSTAL AT STA 947.5+2'; LBL 25; WL 208 IS CORRODED ON UPPER SURFACE. REMOVED CORROSION FROM PASSENGER CABIN FLOOR INTERCOSTAL STA 947.5 + 2' LBL 25 WL 208. VERIFIED USING 10X MAG GLASS, IAW SRM 53-70-51-1A-1. EVALUATED INTERCOSTASDR R61A2021010900018Floor Support · corrodedDURING HEAVY CHECK INSPECTION CORROSION FOUND ON FWD FUSELAGE, FLOOR SUPPORT FITTING AT FR 16 LBL 24. FWD FUSELAGE FLOOR SUPPORT FITTING AT FR 16 LBL 24 REPLACED, IAW EMB 170/175 SRM 51-43-03.SDR R61A2021010900017Seat Track · corrodedDURING HEAVY CHECK INSPECTION CFIII, FLOOR STRUCTURE, CORROSION FOUND DOUBLER UPPER PLATE AFT INBOARD TRACK LT SIDE BETWEEN FR 85-86. CFIII, FLOOR STRUCTURE UPPER PLATE, AFT INBOARD TRACK LT SIDE BETWEEN FR N85-86 REPLACED, IAW ERJ-175 SRM 51-41-01 AND SRM 51SDR R61A2021010900016Floor Support · corrodedDURING HEAVY CHECK INSPECTION CFIII, FLOOR STRUCTURE, CORROSION FOUND ON RT FLOOR SUPPORT BETWEEN FR 88-90. CFIII, FLOOR STRUCTURE, RT FLOOR SUPPORT, BRWN FR 88-89 REPLACED, IAW ERJ-175 SRM 51-43-01 AND SRM 51-42-01.SDR R61A2021010900015Gusset · corrodedDURING HEAVY CHECK INSPECTION CFIII, FLOOR STRUCTURE, CORROSION FOUND AT GUSSET PLATE AT FR 91 RT SIDE. GUSSET PLATE AT FR 91 RT SIDE, CRIII FLOOR STRUCTURE REPLACED, IAW ERJ 175 SRM 51-41-02.SDR R61A2021010900011Floor Support · corrodedDURING HEAVY CHECK INSPECTION FOUND CORROSION ON FWD FUSELAGE, FLOOR SUPPORT FITTING AT FR 16 LBL 24. FWD FUSELAGE FLOOR SUPPORT FITTING AT FR 16 LBL 24 REPLACED, IAW EMB 170/175 SRM 51-43-03.SDR DALA2020122204189Stiffener · crackedWINGS CENTER WING FRONT SPAR AT FR 36 FLOOR BEAM & VERTICAL STIFFENER CRACKS FOUND Y-765 ZONE 1, 2 Y254 ZONE 1. CORRECTIVE ACTION: COMPLIED WITH ER/A 588680-14AD.SDR V0XD20202212001Striker · corrodedSTRICKER ANGLE AT GALLEY SERVICE DOOR CUT OUT CORRODED. CORRECTIVE ACTION TO BE PERFORMED ON AVMAX WORK ORDER 80892 WORK CARD 1050.SDR DALA2020122104185Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR STRINGERS, RBL 7.55 AT STA 1333, STA 1362, STA 1374, RBL 10.45 AT STA 1360, STA 1371 AND RBL 16.10 AT STA 1374. STRINGERS REPAIRED PER SRM.SDR DALA2020122104156Intercostal · crackedCRACK INDICATION FOUND IN OPEN HOLE 1 (UPPER INBOARD POSITION) LOCATED ON INTERCOSTAL DOOR STOP FITTING 7 POSITION FR 16 RT SIDE. CORRECTIVE ACTION: REPLACED INTERCOSTAL FR 16 RT SIDE AT LEVEL STOP FITTING NR 7.SDR SWAA2021052537321Gusset · crackedFWD CARGO GUSSET CRACKED @ BS 500I STR 19R. / REMOVED AND REPLACED FWD CARGO GUSSET @ STA 500I STR 19R IAW SRM 51-40-02 (D95)SA-M 326 (A1303983)SDR SWAA2021042337328Floor Support · corrodedAFT CARGO COMPARTMENT; UPPER FASTENER HOLES ON INTERCOSTAL CORRODED ON UPPER AND LOWER SURFACES; STA 747-767 RBL 27 WL 156. / EVALUATED LIMITS OF DAMAGE ON AFT CARGO BAY R/H INTERCOSTAL STA 747 - STA 767 RBL 27 WL 156. NO ALLOWABLE DAMAGE LIMITS FOUND IN 737-8SDR SWIA202056737Plate · corroded*FORWARD AND AFT LOWER JOINT PLATES FOR THE FORWARD BAGGAGE BAY SURROUND STRUCTURE HAVE CORROSION, FS536.00 & FS575.00, STGR25L (MARKED) (C-CHECK) RO 3/8/2021 REMOVED AND REPLACED FWD AND AFT LWR JOINT PLATE AT FS 536.00 AND FS 575.00 STGR 25L REF CRJ700 SDR SWIA202056317Floor Support · corrodedFLOOR BEAM AT LBL 9 HAS MULTIPLE SPOTS OF MINOR CORROSION FROM FS 409.00 +80 TO FS 409.00 +128 (C-CHECK) RO 2/17/2021. REPAIRED FLOOR BEAM AT LBL 9 BETWEEN FS 409.00+80 TO FS409.00+128 IAW CRJ200 SRM 51-42-21, 51-42-10, 51-42-22 AND SKYWEST TASK CARD 51-900-1SDR AALA202101219010Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK FOUND ON SHEAR PLATE, L=0.935 INCHES. REPLACED SHEAR PLATE LOCATED FROM FR 69 TO FR 70 AT LEVEL 23R AT AFT GALLEY AREA, PER SRM 51-72-11-911-001.SDR IPXA2021011964634Intercostal · crackedINSPECTION TYPE: C3 NR 3 A/C COMPARTMENT INTERCOSTAL CRACK AT STA 595 LON 33R. REMOVED AND REPLACED CRACKED INTERCOSTAL AT NR 3 A/C COMPARTMENT, IAW DWG ACA3804 AND SRM 51-35-01. (MINOR)SDR AALA202101129017Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND SHEAR PLATE WITH L=1.500 INCH CRACK AT FR 69 TO FR 70 AND STR 23L. REPLACED SHEAR PLATE AT AFT GALLEY AREA, IAW A321 SRM 51-42-11-801 AND DWG D53474180.SDR AALA202101069003Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON AFT GALLERY AREA LOWER SILL CENTER FITTING BETWEEN FR 66 AND FR 68 STR 23L MEASURING 1.522 X 0.474 X 0.069. REPLACED CENTER FITTING, PER SRM A321 51-72-11-911-001 AND DRAWING D53480505.SDR AALA202101049028Support · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON SILL AT FR 66 TO FR 68 AND STR 23R IN AFT GALLEY AREA MEASURING 1.110 X 0.577 X 0.052 INCH. REPLACED LOWER SILL, REF SRM 51-72-11-911-00.SDR AALA202101049027Support · corrodedAIRCRAFT IN BASE MAINTENANCE. CORRODED AREA AT LOWER SILL BETWEEN FR 66 TO FR 68 LEFT SIDE AT LEVELOF STR 23L MEASURING L=0.736 INCH; W=0.562 INCH; D=0.054 INCH. PERFORMED PERMANENT REPAIR ON LOWER SILL, IAW A321 SRM 53-41-14-300-001 PRINCIPLE 7.SDR AALA202012299003Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORROSION ON SILL SHAPE CENTER FITTING AT FR 66 TO FR 68 AND STR 23R, MEASURING L=1.437 INCH, W=0.598 INCH, D=0.069 INCH. REPLACED CENTER FITTING, IAW A321 SRM 51-72-11-911-001, 51-42-11-801 & DWG D53480505.SDR SWIA202054720Floor Support · corrodedFLOOR SUPPORT ANGLE FROM FS 310.00 TO 333.00 AT LBL 27 IS CORRODED. C-CHECK RO 12/24/2020. REMOVED AND REPLACED FLOOR SUPPORT ANGLE FROM FS 310.00 TO 333.00 AT LBL 27, IAW CRJ-700 SRM.SDR SWIA202054719Intercostal · corrodedINTERCOSTAL FROM FS 310.00 TO 333.00 AT STRINGER 21L IS CORRODED. C-CHECK RO 12/24/2020. REMOVED AND REPLACED INTERCOSTAL FROM FS 310.00 TO 333.00 AT STRINGER 21L, IAW CRJ-700 SRM. REF ATTACHED TASK CARD AND M-337 FOR RII TASKS. NO CHANGE TO WEIGHT AND BALASDR REXA2020122600859Doubler · corrodedPOTABLE WATER DRAIN HOSE DOUBLER AT FS 605.00 BETWEEN STR 26R AND 25R HAS ONE SMALL AREA OF CORROSION. REMOVED & REPLACED POTABLE WATER DRAIN MAST DOUBLER AT FS 605, IAW CRJ 200 SRM 51-42-06 AND 51-40-11.SDR MASA20201219128Intercostal · corrodedCORROSION ON INTERCOSTALS (2 EA) IN STA FS 349 TO FS 364 NEAR STGR 27 AT MAIN AVIONICS COMPARTMENT. CORRECTIVE ACTION: INSTERCOSTALS (2 EA) WAS REPLACED, PER CRJ900 SRM 51-41-06-001-001A01 PAR 6 A AND SRM 51-42-20-001-A01 PAR 6A.SDR DALA2020121804145Intercostal · crackedCRACK INDICATION FOUND IN OPEN HOLE 3 (LOWER INBOARD POSITION) LOCATED ON INTERCOSTAL AT DOOR STOP FITTING 7 FR 16 LT SIDE. CORRECTIVE ACTION: C/W ERA NR 588914-14AD REV ORIGINAL.SDR DALA2020121704136Floor Support · corrodedDURING INSPECION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS LBL 2.90, 7.55, 10.45 16.10, STA. 1470 AT AFT CARGO COMPARTMENT. STRINGER REPAIRED, PER SRM.SDR DALA2020121704135Floor Support · corrodedDURING INSPECTION CORROSION LEVEL 2 WAS FOUND ON FLOOR STRINGERS LBL 2.90, 7.55 AND 10.45, STA 1510 AT AFT CARGO COMPARTMENT. MAINTNENACE REPAIRED, PER SRM.SDR SWAA2021060837121Shield · crackedAFT CARGO BAY; FLOOR SHIELD @ BS 794.3 CRACKED / REMOVED AND REPLACED FWD FLOOR; SHIELD IN AFT CARGO COMPARTMENT AT STA 794 IW SRM 51-40-2-0G-0 AND BOEING DWG # 146A0081 REV A. APPLIED CIC IAW AMM 51-21-91-620-802. ATAG WN1277SDR SWAA2021052137236Angle · corrodedFWD CARGO COMP.AFT BULKHEAD BOTTOM ANGLE CORRODED AROUND FASTNER HOLES STA 500I WL 158 LBL 25-RBL 25 / REMOVED AND REPLACED AFT BULKHEAD; LOWER ANGLE IN FWD CARGO COMPARTMENT IAW SRM 51-40-02-0G-0 AND BOEING DWG # 143A9481 REV - P/N 143A9485-35 ATAG WN0271SDR SWAA2021052137119Shield · corrodedAFT CARGO BAY; FLOOR SHIELD @ BS 847-867; RBL 20-25; WL 156 CORRODED / REMOVED CORROSION FROM AFT SHIELD IN AFT CARGO COMPARTMENT AT STA 847 - 867 RBL 25 IAW SRM 51-10-02-0G-0. VERIFIED LIMITS ORIGINAL THICKNESS .050'; LOSS OF .008'; REMAINING .042' OUT OF LIM
Back to JASC 5320