JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JR2R20201125512Gusset · corrodedGUSSET ON FLOOR BEAM LBL 9 AT FR 89 FOUND TO BE CORRODED OUT OF LIMITS.SDR SWAA2021081032881Support Bracket · crackedLEFT FWD UPPER WTB FAIRING 191AL AFT LOWER SUPPORT BRACKET CRACKED. / R&R'D LEFT FWD UPPER WTB FAIRING 191AL AFT LOWER SUPPORT BRACKET PER SRM 51-40-02 AND SRM 51-10-02.SDR SWAA2021081034734Stiffener · damagedFUSELAGE STIFFENER LWR CHORD DAMAGED @ BS 188-LBL 14.5 / REMOVED & REPLACED FUSELAGE STIFFENER PER SRM 51-10-02SDR SWIA202055788Fitting · corrodedFWD JACK FITTING - R/H JACK FITTING SUPPORT CORRODED AT BOTTOM FLANGE AS MARKED (C-CHECK) RO 2/1/2021 CORROSION FOUND ON LOWER ATTACHMENT FLANGE AS WELL AS WEB ELEMENT THEREFORE FOUND OUT OF LIMITS REF CRJ900 SRM 53-00-00-101-001-A01. - INSTALLED NEW FWD JSDR SWIA202055481Retainer · worn3 EA FAIRING 193AB RETAINERS ARE WORN BEYOND PERMISSIBLE DIMENSIONS, RETAINERS ARE ATTACHED TO FUSELAGE SIDE, FLAGGED. C-CHECK RO 1/16/2021. REMOVED WORN RETAINERS AND INSTALLED 3 EA NEW RETAINERS WITH NEW NUTPLATES (P/N: 601R31036-10, 601R31036-11, 601R3103SDR SWIA202055470Floor Support · corrodedFLOOR BEAM CAP HAS CORROSION AT MULTIPLE AREAS ON THE INBOARD FLANGE RBL 9, FS 559.00+11-FS 569.00, MARKED. C-CHECK RO 1/16/2021. REMOVED CORROSION ON FLOOR BEAM CAP IN MULTIPLE AREAS ON INBOARD FLANGE RBL 9 FS 559.00+11-FS 569.00, REF CRJ200 SRM 51-21-06. SDR SWIA202055428Floorbeam · corrodedFLOOR BEAM CAP HAS CORROSION AT MULTIPLE AREAS ON THE INBOARD FLANGE LBL 9, FS 559.00+11-FS 569.00, MARKED. C-CHECK RO 1/16/2021. REMOVED AND REPLACED FLOOR BEAM AT FS 559+11 TO FS 569 AT LBL 9, REF REO 601R-53-51-540 REV - DATED 2020-12-18, DWG 601R31032 RESDR SWIA202055427Floorbeam · corrodedFLOOR BEAM CAP HAS CORROSION AT MULTIPLE AREAS ON THE OUTBOARD FLANGE RBL 9, FS 559.00+32-FS 559.00+112, MARKED. C-CHECK RO 1/16/2021. REMOVED AND INSTALLED NEW FLOOR BEAM CAP AT RBL 9, FS 559.00+32-FS 559.00+112, REF CRJ-200-SRM 51-42-34,CRJ-200 SRM 51-42-2SDR SWIA202055426Floor Support · corrodedRIGHT FLOOR SILL CORRODED AT MULTIPLE LOCATIONS, FS 559.00+85-FS 559.00+116, MARKED. C-CHECK RO 1/16/2021. REMOVED AND REPLACED RT FLOOR SILL P/N 601R31133-102S, REF CRJ-200 SRM 51-42-06, CRJ-200 SRM 51-42-21, AND DRAWING 601R31026 REV F. COMPLIED WITH 51-9SDR SWIA202055424Floor Support · corrodedFLOOR BEAM CAP HAS MULTIPLE AREAS OF CORROSION ON THE INBOARD & OUTBOARD FLANGE RBL 9 FS 409.00+5-FS 409.00+118, MARKED. C-CHECK RO 1/16/2021. INSTALLED NEW FLOOR BEAM CAP AT RBL 9 BETWEEN FS 409.00+5 AND FS 409.00+118, REF DWG 601R31117 REV -E AND REO 601SDR SWIA202055423Floor Support · corrodedFLOOR BEAM CAP HAS MULTIPLE AREAS OF CORROSION ON THE INBOARD FLANGE LBL 9 FS 409.00+5-FS 409.00+118, MARKED. C-CHECK RO 1/16/2021. REMOVED OUT OF LIMITS FLOOR BEAM CAP AND REPLACED, INSTALLED WITH NEW FABRICATED FLOOR BEAM CAP P/N 601R31117-17 AT FS 409.00+SDR SWIA202055422Floor Support · corrodedRIGHT FLOOR SILL HAS MULTIPLE AREAS OF CORROSION FS 409.00+72-FS 409.00+128, MARKED. C-CHECK RO 1/16/2021. REMOVED HEAVY COROSION FROM MULTIPLE AREAS OF RT FLOOR SILL PANEL BETWEEN FS 409+72 & FS 409+128, REF CRJ200 SRM 51-21-06. EVALUATED AND FOUND BLENDEDSDR SWIA202055421Floor Support · corrodedLEFT FLOOR SILL FROM FS 357-FS 409.00+04 HAS MULTIPLE AREAS OF CORROSION, MARKED. C-CHECK RO 1/16/2021. REPAIRED LT FLOOR SILL FROM FS 357 TO FS 409.00+04, REF CRJ 200 SRM 51-42-06, DWG 601R31148 REV W AND REO 601R-53-21-3364, REV- DATED 2020-12-04. COMPLISDR SWIA202055420Floor Support · corrodedRIGHT FLOOR SILL FROM FS 357-FS 409.00+04 HAS MULTIPLE AREAS OF CORROSION, MARKED. C-CHECK RO 1/16/2021. REMOVED NOTED CORROSION AND REPLACED DAMAGED SPLICE ANGLE WITH NEW SPLICE ANGLE ON RIGHT FLOOR SILL FROM FS 349-FS 409.00+04, NDT INSPECTED NO DEFECTS NOSDR AALA202101049010Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE, PER SRM 51-42-11.SDR AALA202012289006Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND L=0.838 INCH CRACK ON SHEAR PLATE AT FR 69 TO FR 70 AND STR 23R IN AFT GALLEY AREA. REPLACED SHEAR PLATE, IAW SRM A321 51-72-11-911-001, 51-42-11-801 AND DRAWING D53474180.SDR AALA202012179011Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON CENTER SHAPE FITTING BETWEEN FR 66 AND FR 68 AT STR 23L, MEASURING L=9.670 INCH, W= 0.500 INCH D=0.045 INCH. REPLACED CENTER FITTING, IAW SRM A321 51-72-11-911-001, 51-42-11-801 & DWG D53480505.SDR AALA202012159010Support · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON SILL AT FR 68 AND STR 23R AT AFT GALLEY AREA, MEASURING L=1.196 INCHES W=0.850 INCHES D=0.063 INCHES. PERMAMENT REPAIR PERFORMED ON LOWER SILL AT LEVEL AT AFT GALLEY AREA, IAW A321 SRM 53-41-14-300-001 REPSDR SWIA202054603Floor Support · corrodedCORROSION FORWARD WET AREA RT SILL FRAME 17 TO 20 CORRODED IN 3 PLACES. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT SILL FRAME 17-20.SDR SWIA202054602Floor Support · corrodedCORROSION FORWARD WET AREA RT SILL FRAMES 12 TO 14 CORRODED. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT SILL FRAME 12-14, REF EMB SRM.SDR SWIA202054601Floor Support · corrodedCORROSION FORWARD WET AREA RT INTERCOSTAL BEAM CORRODED BETWEEN FRAMES 17 AND 18. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT INTERCOSTAL BEAM BETWEEN FR 17-18, REF EMB SRM.SDR SWIA202054600Support · corrodedCORROSION FORWARD WET AREA LT SILL CORRODED FRAME 19. C-CHECK RO 12/10/2020. REMOVED AND REPLACED LT SILL FRAME 19, REF EMB SRM.SDR SWIA202054598Floor Support · corrodedCORROSION FORWARD WET AREA LT SILL CORRODED FRAME 16. C-CHECK RO 12/10/2020. REMOVED AND REPLACED FWD WET AREA LT SILL AT FRAME 16, REF EMB175 SRM.SDR SWIA202054596Support · corrodedCORROSION ON LT PANEL SUPPORT AT FRAME 90. C-CHECK RO 12/10/2020. REMOVED AND REPLACED LT PANEL SUPPORT AT FRAME 90, REF EMB SRM.SDR SWIA202054593Gusset · corrodedCORROSION ON RT GUSSET PLATE AT FRAME 91. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT GUSSET FRAME 91 AND APPLIED FINISH, REF EMB SRM. SEE CONTIUATION CARD FOR WORK PERFORMED.SDR SWIA202054592Floor Support · corrodedCORROSION ON RT BEAM FROM FRAME 90 TO 91. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT INTERCOSTAL FR 90-91 AND APPLIED FINISH, REF EMB SRM. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202054591Gusset · corrodedCORROSION ON BOTH CENTER GUSSET PLATES AT FRAME 90. C-CHECK RO 12/10/2020. REMOVED AND REPLACED BOTH CENTER GUSSETS AT FR 90, REF EMB SRM. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202054590Gusset · corrodedCORROSION ON RT GUSSET PLATE AT FRAME 90. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT GUSSET PLATE AT FRAME 90, REF SRM.SDR SWIA202054589Support · corrodedCORROSION ON RT PANEL SUPPORT FROM FRAME 89 TO 90. C-CHECK RO 12/10/2020. REMOVED AND REPLACED RT PANEL SUPPORT FR 89 TO 90, REF EMB175 SRM.SDR REXA2020120700807Floor Support · corrodedPAX DOOR CENTER FLOORBOARD SUPPORT ANGLE IS CORRODED AT NUTPLATE HOLES. REPLACED PAX DOOR CENTER FLOORBOARD SUPPORT ANGLES, IAW CRJ 900 SRM 51-40-11-001-A01, 51-42-06-001-A01 AND 51-41-02-001-001-A01.SDR SWAA2020120734738Web · damagedFUSELAGE FRAME AT BS 188 DAMAGED AT WEB AT LBL 14-15 MOD. REPAIRED WED AT BS 188 LBL 14-15, PER SRM 51-70-13-2R-4. THIS IS A TLD REPAIR, WITHIN 30 DAYS AFTER THE AIRPLANE RETURNS TO SERVICE CONTACT THE BOEING COMPANY FOR INSPECTION THRESHOLD PERMANENT ACTON SDR SWAA2020120734737Web · damagedFUSELAGE FRAME AT BS 196.5 DAMAGED AT WEB AT LBL 14-15 MOD. REPAIRED WEB AT 196.5 LBL 14-15, PER SRM 51-70-13-2R-4. THIS IS A TLD REPAIR WITHIN 30 DAYS AFTER THE AIRPLANE RETURNS TO SERVICE, CONTACT THE BOEING COMPANY FOR INSPECTION THRESHOLD. PERMANENT REPSDR AALA202012029012Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON LOWER SILL AT FR 68 AND STR 23L. CORROSION AREA MEASURED L=1.151 INCH, W=0.783 INCH, D=0.063 INCH. PERFORMED PERMANENT REPAIR ON LOWER SILL IN AFT GALLEY AREA, IAW A321 SRM 53-41-14-300-001 PRINCIPLE 5 FISDR SCNA20201201390Shear Web · corrodedCORROSION ON AFT CABIN FLOOR SHEAR WEB STA 1016+3 WL 208 RBL 8.5. REPAIRED AFT CABIN FLOOR SHEAR WEB AT STA 1016+3 WL 208, IAW ATS ET 20-03552 REV IR AND SCA EA 53-0073 REV 00 RBL 8.5.SDR SCNA20201201368Shear Web · corrodedCORROSION ON AFT CABIN FLOOR SHEAR WEB STA 1016 LBL 8 WL 208. REPAIRED AFT CABIN FLOOR SHEAR WEB AT STA 1016 LBL 8 WL 208, IAW ATS ER 20-03548 REV IR AND SCA EA 53-0072.SDR SCNA20201201366Shear Web · corrodedCORROSION ON AFT CABIN FLOOR SHEAR WEB, STA 1016+3.5 RBL 11 WL 208. REPAIRED AFT CABIN FLOOR SHEAR WEB AT STA 1016+3.5" RBL 11 WL 208, IAW ATS ER 20-03552 REV IR AND SCA EA 53-0073 REV 00.SDR FDEA202011242951Floor Support · crackedLOWER BULK CARGO COMPARTMENT FLOOR STRINGER FOUND CRACK AT STATION 1937 RIGHT BUTT LINE 41.5. LOWER BULK CARGO COMPARTMENT FLOOR STRINGER AT STATION 1937 RIGHT BUTT LINE 41.5 REPAIRED, AS PER B777 SRM 53-70-53-2R FIGURE 202 REPAIR 2 FROM STATION 1926.5 STATIOSDR JGVR20201124001Web · corrodedBENDED CORRODED AREA AT FS 548.5 RIB WEB LOCATED AT BONDING STRAP ATTACHMENT, PERFORMED NDT AND REPORTED RESULTS FOR REPAIR DISPOSITION. CLEANED, TREATED, PRIMED AND APPLIED CIC TO REPAIR AREA, IAW TEXTRON REPAIR MEMO.SDR SWIA202055417Floor Support · corrodedTHE RBL 27 FLOOR BEAM CAP HAS CORROSION AND CHAFES ON ITS OUTBOARD FLANGE BETWEEN APPROXIMATELY FS 605 AND APPROXIMATELY FS 621 (MARKED WITH RED GREASE PENCIL). C-CHECK RO 1/16/2021. REMOVED & REPLACED RBL 27 FLOOR BEAM CAP AT APPROXIMATELY FS 605 TO FS 621.SDR SWIA202055415Floor Support · corrodedTHE LBL 9 FOOR BEAM CAP HAS CORROSION AND CHAFES ON ITS INBOARD AND OUTBOARD FLANGES BETWEEN APPROXIMATELY FS 605 AND APPROXIMATELY FS 621(MARKED WITH RED GREASE PENCIL). C-CHECK RO 1/16/2021. REMOVED AND REPLACED THE LBL 9 FLOOR BEAM CAP AT APPROXIMATELY FSSDR SWIA202055414Floor Support · corrodedTHE LBL 27 FOOR BEAM CAP HAS CORROSION AND CHAFES ON ITS INBOARD AND OUTBOARD FLANGES BETWEEN APPROXIMATELY FS 605 AND APPROXIMATELY FS 621 (MARKED WITH RED GREASE PENCIL). C-CHECK RO 1/16/2021. INSTALLED NEW FLOOR BEAM CAP AT LBL 27, FS 605-FS 621, REF CRJ SDR SWIA202055412Intercostal · crackedTHE RT INTERCOSTAL AT FS 484, BETWEEN RBL 27 AND RBL 36, HAS A CRACKED INBOARD CLIP. C-CHECK RO 1/16/2021. REMOVED CRACKED CLIP AND INSTALLED NEW CLIP P/N: 601R1171-9 AT FS 484 RBL27 (INBOARD), REF CRJ200 SRM 51-42-06 AND SRM 51-42-21 AND REFERENCE ONLY BOMBSDR SWIA202055411Floor Support · corrodedTHE RBL 9.0 FLOOR-SUPPORT BEAMS CAP HAS CORROSION ALONG ITS ENTIRE LENGTH, FROM APPROXIMATELY FS 409+128 TO APPROXIMATELY FS 559, THE CORROSION IS ON BOTH THE INBOARD AND OUTBOARD FLANGES, AND EXTENDS UNDER THE FLOOR BEAM SEAT RAILS (MARKED WITH RED GREASE PENSDR R61A2020121500886Support Bracket · crackedWHILE IN HEAVY CHECK CF 1 LT EMERGENCY VENT SUPPORT BRACKET AT FR 31 FOUND CRACKED. REPLACED ON AAR NRC 4500812-1000-007, PER SRM 51-41-01. THIS AIRCRAFT WAS RETURNED TO SERVICE.SDR R61A2020121500885Seal Depressor · crackedWHILE IN HEAVY CHECK, FWD PASS DOOR CUT-OUT UPPER CORNER SEAL DEPRESSOR HAS A CRACK. REPAIRED ON AAR NRC 4500812-2000-0029, PER SRM 51-41-01. THIS AIRCRAFT HAS BEEN RETURNED TO SERVICE.SDR REXA2020120700812Floor Support · corrodedAFT BAGGAGE BAY FLOOR, LOWER SILL CORRODED BETWEEN FS 1000 TO FS 1047, SILL OUT OF LIMITS. REMOVED/RE-INSTALLED THREE INTERCOSTAL FOR ACCESS. REMOVED/REINSTALLED LOWER COAMING AND STOP FITTINGS (2 EA) FOR ACCESS. REMOVED SILL-MATCH DRILLED NEW SILL P/N MM6SDR REXA2020120700802Intercostal · corrodedLT & RT FWD INTERCOSTALS FS 349.00-FS 364.00 AT STGR 27, CORRODED. INSTALLED NEW LT AND RT FWD INTERCOSTALS AT STGR 27, FS 349.00 TO FS 364.00, IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. ADDITIONAL PART REPLACED: SH670-32075-4.SDR SCNA20201201391Shear Web · corrodedCORROSION ON SHEAR WEB AT STA 986, LBL 32-46, WL 208. DAMAGE TO SHEAR WEB AT STA 986 LBL 32-46 WL 208 FOUND TO BE OUT OF LIMITS, DUE TO NO LIMITS FOUND IN SRM. REMOVED AND REPLACED WITH NEW PO NR 808105, IAW SRM 51-40-02-0G-0 AND DWG NR 147A5700.SDR SCNA20201201384Support Angle · corrodedCORROSION ON L1 DOOR LOWER SILL THRESHOLD SUPPORT ANGLE BS 316-344 LBL 68 WL 208. CORROSION DAMAGE ON L1 DOOR LOWER SILL THRESHOLD SUPPORT ANGLE BS 316-344 LBL 68 WL 208 FOUND TO BE OUT OF LIMITS, PER SRM 53-10-15-1A-1 STEP 4B FOG 108 DETAIL D. REMOVED AND RSDR SCNA20201201370Channel · corrodedCORROSION ON L2 DOOR MOP SILL STA 947 TO STA 986 WL 208. CORROSION ON AFT ENTRY DOOR LOWER MAIN SILL INNER CHORD STA 947-986 WL 208, FOUND TO BE OUT OF LIMITS, IAW SRM 53-70-51-1A-1 FIG 103 DETAIL D. REMOVED AND REPLACED DAMAGED INNER CHORD, IAW SRM 51-40-02
Back to JASC 5320