What was found
THE RBL 9.0 FLOOR-SUPPORT BEAMS CAP HAS CORROSION ALONG ITS ENTIRE LENGTH, FROM APPROXIMATELY FS 409+128 TO APPROXIMATELY FS 559, THE CORROSION IS ON BOTH THE INBOARD AND OUTBOARD FLANGES, AND EXTENDS UNDER THE FLOOR BEAM SEAT RAILS (MARKED WITH RED GREASE PENCIL). C-CHECK RO 1/16/2021. CUT OUT DAMAGED FLOOR BEAM AND BEAM FLANGES AT RBL 9, APPROXIMATELY FS 409128 TO FS 559.0. FABRICATED & INSTALLED NEW FLOOR BEAM SECTION, SPLICE PARTS & C- CHANNELS, AS PER REO 601R-53-41-2824 REV -, DATED 2020-12-06, DRAWING 601R31025 REV F AND CRJ 200 SRM'S 51-42-06, 51-42-21. INSTALLED USING NEW NUT CLIPS , DOME NUTS & FASTENERS. PRESSURE LEACK CHECKS GOOD. SEE CONTINUE CARDS FOR DETAILS. COMPLIED WITH 51-900-1003-SKY.