SDR CALA2020040300776Door Sill · corrodedDOOR 2R DOOR SILL FND CORROSION UNDER AFT GIRT BAR FITTING AREA REF NON-ROUTINE NO.9407205 ORIGINATED SPEC NO.A3N B-53-3-6299. PERFORMED, 2R DOOR SILL REPLACED AS PER DWG D5348 0078 ISSUE G AND E53474250000 ISSUE AF AND D53480505006 ISSUE EQ . RII BY TA620SDR FDEA2020040320658Strap · crackedAREA AFT OF THE AFT CARGO COMPARTMENT ST 1661 APPROX RBL 24 MISC MAIN CABIN FLOOR SUPPORT STRUCTURAL STRAP IS CRACKED REPAIRED STRAP IAW B757 SRM 53-00-51-2R PO:958485.5, PO:920167.4, PO:834933.1SDR ASOA202004027033Door Sill · corrodedCARGO DOOR CUT-OUT SILL HAS CORROSION. REMOVED AND REPLACED CARGO DOOR CUT-OUT SILL. AIRCRAFT STILL IN C CHECK.SDR UIEA2020040200590Panel Support · crackedCOCKPIT - CTR CONSOLE LHS FWD AREA FOUND CRACK(<P>COCKPIT - LH PILOTS FWD PANEL SUPPORT WEB CRACK AREA REPAIRED IAW RI # RI-53-00-13945 REV A</P>)SDR UIEA2020040200597Panel Support · crackedCOCKPIT-CTR CONSOLE RHS FWD AREA FOUND CRACKED(<P>COCKPIT-RH PILOTS FWD PANEL SUPPORT WEB CRACK AREA REPAIRED IAW RI # RI-53-00-13945 REV A</P>)SDR UIEA2020040200598Structure · crackedLH MAIN ENTRY DOOR 5 CUTOUT AFT UPPER CORNER 1 EA FASTENER HOLE FOUND CRACK(<P>LH MAIN ENTRY DOOR 5 CUTOUT AFT UPPER CORNER CRACK AREA MODIFICATION PER SB 53A2839 AND EO: 4453A797 PART 5</P>)SDR UIEA2020040200599Structure · crackedRH MAIN ENTRY DOOR 5 CUTOUT AFT UPPER CORNER 1 EA FASTENER HOLE FOUND CRACK(<P>RH MAIN ENTRY DOOR 5 CUTOUT AFT UPPER CORNER CRACK AREA MODIFICATION PER SB 53A2839 AND EO" 4453A797 PART 6</P>)SDR UIEA2020040200600Doubler · corrodedFUS-HINGE DOOR #191L ATT FRAME SEBERAL AREA FOUND CORROSION(<P>FUS-HINGE DOOR 191L ATTACHMENT FRAME DOUBLER P/N: 69B16975-8 DAMAGE AREA REPAIRED IAW RI-53-00-13982 REV A</P>)SDR UIEA2020040200603Floor Support · corrodedCABIN-STA 936 RBL 116" L-SHAPE ANGLE FOUND CORROSION(<P>CABIN-STA 936 RBL 116" FLOOR SUPPORT CORROSION AREAS REPAIRED IAW RI-53-20-13969 REV A</P>)SDR UIEA2020040200622Structure · corrodedCABIN-STA 1846 RBL 35" FLOOR BEAM SPLITTER FOUND CORROSION.(<P>CABIN-STA 1846 RB 34"-40" FLOOR PANEL SPLITTER P/N: FSS1174A0507S100 FABRICATED AND REPLACED IAW ATLAS EO: 4453B792 REV. 0.</P>)SDR UIEA2020040200623Intercostal · corrodedCABIN-STA 1765 CTR FLOOR BEAM INTERCOSTAL FOUND CORROSION.(<P>CABIN-STA 1760-1780 CTR O" FLOOR INTERCOSTAL P/N: 98FS818258-111 FABRICATED AND REPLACED IAW ATLAS EO: 4453B792 REV. 0.</P>)SDR UIEA2020040200624Structure · corrodedCABIN-STA 1630 LBL 11"-33" FLOOR BEAM SPLITTER FOUND CORROSION.(<P>CABIN-STA 1630 LBL 11"-33" FLOOR PANEL SPLITTER P/N: FSS1174A2117T100 FABRICATED AND REPLACED IAW ATLAS EO: 4453B792 REV. 0.</P>)SDR UIEA2020040200644Floor Support · corrodedCABIN-STA 2348 RBL 32-36 FLOOR SUPPORT FOUND CORROSION(<P>CABIN-STA 2348 RBL 32-36 PN: 65B06642-4 FLOOR SUPPORT REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02</P>)SDR UIEA2020040200645Floor Support · corrodedCABIN-STA 780 LBL 116 FLOOR SUPPORT FOUND CORROSION(<P>CABIN-STA 780 LBL 116 FLOOR SUPPORT PLATE P/N" 140U5601-782 REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02</P>)SDR UIEA2020040200646Floor Support · corrodedM/D-STA 860-920 LBL 40 FLOOR SUPPORT FOUND CORROSION(<P>CABIN-STA 860-920 LBL FLOOR SUPPORT PLATE P/N: 69B17613-42 REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02</P>)SDR UIEA2020040200650Intercostal · corrodedCABIN-STA 960-975 RBL 15 FLOOR BEAM FOUND CORROSION(<P>CABIN-STA 940-980 RBL 15 FLOOR INTERCOSTAL REPLACED AND INSTALLED IAW SRM 51-10-02 AND SRM 51-40-02</P>)SDR UIEA2020040200651Scuff Plate · crackedM/D-L1 ENTRY DR CTR SCUFF PLATE FOUND CRACK(<P>M/D-L1 ENTRY DR CTR SCUFF PLATE CRACK AREA REPAIRED AS PER RI-13-13964 REV A</P>)SDR UIEA2020040200652Scuff Plate · crackedM/D- R1 ENTRY DR CTR SCUFF PLATE FOUND CRACK(<P>M/D-R1 ENTRY DR CTR SCUFF PLATE CRACKED AREA REPAIRED AS PER RI-13-10-13964 REV A</P>)SDR 2020F00173Plate · corrodedAIRBORNE/PEMCO NON-ROUTINE 2387N2461 DISCREPANCY: FWD PIT STA 583 (APPROX) S22LH CORRODED AFT DOME NUT MOUNTING PLATE. CORRECTIVE ACTION: REMOVED DOME NUT PLATES IAW B767-200 SRM 51-40-02. REMOVED CORRSION AT STA 583 LBL 90 IAW B767-200 SRM 51-10-02. PERFORM RSDR SWAA2020041435518Support · corrodedSUPPLEMENTAL INFORMATION: ***CORROSION*** AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT CORRODED BS 727 - 767 WL 156 RBL 21 / EVALUATED CORROSION ON ACB R/H FLOOR TO SIDEWALL SUPPORT BS727-767; REMOVED .015' FROM ORIG .040'; FOUND TO BE OUT OF LIMITS; IAW SRM 53SDR SWAA2020041435517Support · corrodedSUPPLEMENTAL INFORMATION: ***CORROSION*** AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT CORRODED BS 727 - 847. WL 156 LBL 21. / EVALUATED CORROSION ON ACB L/H FLOOR TO SIDEWALL SUPPORT; BS 727 847; REMOVED .020' FROM ORIG .040'; FOUND TO BE OUT OF LIMITS; IAW SRSDR PCSA202003300001Floor Support · corrodedAIRBORNE/PEMCO NON-ROUTINE 2387N2202 DISCREPANCY: MAIN DECK STA 996-1063 LBL 74.75 CORRODED SEAT TRACK OUT OF LIMITS. CORRECTIVE ACTION: REMOVED DAMAGE AND AFTER FUTHER EVALUATION OF I/B AND O/B FLANGE LBL 74.75 FROM STA
996 TO STA 1063 APPROX IS WITHIN ALLOWSDR SWAA2021062435304Scuff Plate · crackedFWD CARGO COMPATMENT FWD CORNER SCUFF PLATE CRACKED / VERIFIED NEW SCUFF PLATE IAW B737 AIPC 53-13-00-08. LOCATED AND DRILLED IAW B737 SRM 51-40-05-0G-0. SCUFF PLATE INSTALLED ON N/R # Y200340SDR SWIA202005190823Angle · corrodedPAX FLOOR ANGLE HAS CORROSION (C-CHECK) RO 5/16/2020 REMOVED AND INSTALLED NEW PAX DOOR ANGLE IAW CRJ 900 SRM.SDR AALA2020042749012Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT AFT WALL SUPPORT RAIL AT BS 500I AND BL 50. REPLACED RAIL PER SRM 51-40-02.SDR AALA202004209002Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL BETWEEN BS 500C AND BS 500J AT S25R. REPLACED TRANSITION PANEL PER SRM 51-40-02.SDR AALA202004209001Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL BETWEEN BS 500 AND BS 500J AT S26L. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R.SDR SIMA2020041701005Structure · corrodedCORROSION ON FR 80 APU SHUNT AREA-C/A-CORROSION BLENDED OUT OF LIMIT ON FR 80 APU SHUNT AREA. ON FR 80 APU SHUNT AREA REPAIR PARTS ARE FABRICATED AS PER SRM 53-32-04 FIG 203. ON FR 80 APU SHUNT AREA, FR 80 REPAIR PART INSTALLED WITH SOLID RIVET IAW SRM 53-32-0SDR AALA2020040989010Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FORWARD CABIN FLOOR INTERCOSTAL BETWEEN BS 328 AND BS 344 AT LBL 46. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA2020040989009Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FORWARD CABIN FLOOR INTERCOSTAL BETWEEN BS 312 AND BS 328 AT LBL 46. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA2020040989007Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FORWARD CABIN INTERCOSTAL BETWEEN BS 312 AND BS 328 AT RBL 33. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR SIMA2020040801004Channel · crackedWEB SUPPORT IN THE AFT END OF THE NLG BAY AT FRAME 7 IS CRACKED.-C/A-RAI WEB SUPPORT (CHANNEL) IN THE AFT END OF THE NLG BAY AT FR 7 IAW SRM 51-10-02.SDR YENA2020040610270Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION LOWER SILL UPPER SURFACE FR 66-68 LH SIDE; (REF AEM NR 2020-28/1-2020-90695) R & R LOWER SILL BETWEEN FR 66-68 LH SIDE IAW A320 SRM 51-72-11, DWG D53480009, D53474250SDR YENA2020040610267Crossbeam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION AT FR 16 CROSSBEAM HOLE 8 AND HOLE 18, FR 20 CROSSBEAM HOLE 17 AND HOLE 26; REF AEM NR'S 2020-28/1-2020-90691/90692/90693/90694 - PERFORMED PERMANENT CAT A REPAIR IAW A320 SB A320-53-1286 AND JB EC A320-53-1286-01SDR DALA2020040602161Fitting · corrodedCORROSION LEVEL: 2 2 CLIPS AT STA 1373 S39L CORRODED. REPLACED CLIPS (LP 1543273)SDR DALA2020040602154Stiffener · damagedFOUND NOSE WHEEL WELL LH VERTICAL REPAIRED STIFFENER HOLE NOT IN GAGE.HOLE SIZE:0.312"X0.270"AND LARGER THAN FIRST OVERSIZE 0.263". REPAIRED PER ERA 586073-14 (LP 1543089)SDR DALA2020040602153Structure · corrodedCORROSION LEVEL: 2 CORROSION FOUND AT PAX R2 DOOR T-CHORD. CORROSION T-CHORD AT PAX R2 DOOR REPLACED (LP 1543081)SDR DALA2020040602150Structure · corrodedCORROSION LEVEL: 2 WING CENTER SECTION UPPER SURFACE AT STA 955 RBL 76 FOUND CORROSION C/W ERA 585848-14 (LP 1543055)SDR SIMA202004031003Door Sill · corrodedSERVICE DOOR CUTOUT STRUCTURE ENTRENCE SILL HAS CORROSION AT NUT PLATE HOLES-C/A-REMOVED AND REPLACED THE SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR CALA2020040300770Fitting · crackedSHEAR FITTING AT STA 540 LBL 6.14 IS CRACKED. SPT- 7002939 REMOVED & REPLACED SHEAR FITTING AT STA 540 LBL 6.14 IAW EC/RA 5 714-01141 REV ORIGINAL AND APPLIED VAPOR BARRIER IAW B737-800 AM M 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/2SDR CALA2020040300769Fitting · crackedSHEAR FITTING AT STA 540 RBL 6.14 IS CRACKED. SPT- 7002944 REMOVED & REPLACED SHEAR FITTING AT STA 540 RBL 6.14 IAW EC/RA 5 714-01146 REV ORIGINAL & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/2020 SDR CALA2020040300768Fitting · crackedSHEAR FITTING AT STA 540 LBL 40.87 IS CRACKED. SPT- 7002942 REMOVED & REPLACED SHEAR FITTING AT STA 540 LBL 40.87 IAW EC/RA 5714-01144 REV ORIGINAL & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/2020SDR CALA2020040300767Fitting · crackedSHEAR FITTING AT STA 540 LBL 15.04 IS CRACKED. SPT- 7002940 REMOVED & REPLACED SHEAR FITTING AT STA 540 LBL 15.04 IAW EC/RA 5714-01142 REV ORIGINAL & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/2020SDR CALA2020040300766Fitting · crackedSHEAR FITTING AT STA 540 LBL 54.60 IS CRACKED. SPT - 7002943 REMOVED & REPLACED SHEAR FITTING AT STA 540 LBL 54.60 IAW EC/RA 5714-01145 REV ORIGINAL AND APPLIED VAPOR BARRIER IAW B737-800 A MM 28-11-00. SSFR REPORT, 46-0024, ENTERED BY UAL INSPECTION 4/1/2020 SDR CALA2020040300765Fitting · crackedSHEAR FITTING AT STA 540 LBL 32.40 IS CRACKED. SPT- 7002941 REMOVED & REPLACED SHEAR FITTING AND TUBE BRACKET IAW EC/RA 5714 -01143 REV ORIG AT STA 540 LBL 32.40 & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UA L INSPSDR CALA2020040300764Fitting · crackedSHEAR FITTING AT STA 540 RBL 32.40 IS CRACKED. SPT- 7002946 REMOVED & REPLACED SHEAR FITTING AT STA 540 RBL 32.40 IAW EC/RA 5714-01148 REV ORIGINAL & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/2020SDR CALA2020040300763Fitting · crackedSHEAR FITTING AT STA 540 RBLO 15.04 IS CRACKED. SPT- 7002945 REMOVED & REPLACED SHEAR FITTING AT STA 540 RBL 15.04 IAW EC/RA 5714-01147 REV ORIGINAL & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/202SDR CALA2020040300762Fitting · crackedSHEAR FITTING AT STA 540 RBL 54.60 IS CRACKED. SPT- 7002947 REMOVED & REPLACED SHEAR FITTING AT STA 540 RBL 54.60 IAW EC/RA 5714-01149 REV ORIGINAL & APPLIED VAPOR BARRIER IAW B737-800 AMM 28-11-00. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION 4/1/2020SDR SWAA2020040335405Structure · crackedEXTERNAL POWER DOOR CUTOUT HAS HALF INCH CRACK LOWER CENTER SECTION ( MX NOTE ) /SDR UATA2020040200000Support Angle · corrodedFOUND CORROSION ON A FLOOR BOARD SUPPORT ANGLE UNDER THE COCKPIT FLOOR. ANGLES AT FRAME 5 AND NEAR FRAME 6B WERE SEVERELY CORRODED UNDER NUT PLATES. CORRODED AREAS OF ANGLE WAS REMOVED AND SPLICE REPAIRS WERE MADE PER CASA 212 SRM, FIGURE B14.