JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020032001956Door Sill · corrodedCORROSION LOWER SILL AT LEVEL FR68 AND STR23L AT AFT GALLEY AREA, REPAIRED LOWER SILL AT LEVEL FR68 AND STR 23L AT AFT GALLEY AREA AS PER SRM A320 53-41-14-300-001SDR 2020F00113Fitting · corrodedAIRBORNE/PEMCO NON-ROUTINE 2387N1268:MCC CUT-OUT LOWER LATCH CAM PINS FITTING HOLES INSIDE CORROSION CORRECTIVE ACTION: MDCD LATCH PIN FITTINGS REPAIRED PER EO#19398SDR SWAA2021081332383Angle · crackedAFT CARGO STA. 727 LOWER CENTER ANGLE FOR WALL ATTACHMENT CRACKED / REMOVED AND REPLACED ANGLE PER SRM 51-40-02SDR SWAA2021062432279Scuff Plate · crackedAFT CARGO BAY FWD CORNER SCUFF PLATE CRACKED / REPAIRED AFT CARGO BAY-FWD CORNER SCUFF PLATE PER EA #1-A53-2076 REV: 11.SDR SIMA2020061118010Structure · corrodedCOCKPIT UNDERFLOOR BETWEEN FRAMES 13 AND 14 AND STRINGERS 20R AND 18L HAS SURFACE CORROSION. C/W REPAIR IAW ERS-EM-53MR-3758 PART B. TDMI RESTORED.SDR R61A2020060300517Splice Plate · corrodedCORROSION ON SPLICE PLATE ON PANEL 195HL. REMOVED AND REPLACED SPLICE PLATE PN 170-08513-405 & 170-08513-406 REF SRM 20-10-07. SEE W/O H7207 SN 559 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR R61A2020060300516Splice Plate · corrodedCORROSION ON SPLICE PLATE ON PANEL 195GR. REMOVED AND REPLACED SPLICE PLATE PN 170-08513-405 REF SRM 20-10-07. SEE W/O H7207 SN 554 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR SWIA202005190733Intercostal · corroded*INTERCOSTAL LH OF STRG 27 BETWEEN FS 265.00 €“ FS 280.00 IS CORRODED (C-CHECK) RO 5/16/2020 REMOVED AND REPLACED INTERCOSTAL REF DWG AND SRM CHECKS OKAY, COMPLETED TASK CARDSDR SWAA2020050432865Intercostal · corrodedCORROSION WEB - INTERCOSTAL BTW BS747 TO BS767 AT LEVEL STR 25R AT AFT CARGO COMPARTMENT / REPLACED WEB-INTERCOSTAL BTW BS 747 TO BS 767 AT LEVEL STR 25R AT AFT CARGO COMPARTMENT IAW SRM B737-700 51-40-02; 51-10-02 ITEM 9 AND DRAWING 146A7502 REV.ASDR SWIA2020042750384Stiffener · crackedVERTICAL STFFENER CRACKED FS 280 LBL 26 (C-CHECK) RO 4/23/2020 REMOVED AND REPLACED CRACKED STIFFENER FS 280 LBL 26 REF CRJ 900 SRM.SDR SWIA2020042350228Angle · corroded* THE SERVICE DOOR SURROUND LOWER SILL ANGLE FROM FS319.00 TO FS349.00 HAS MULTIPLE LOCATIONS OF CORROSION. (MARKED) (C-CHECK) RO 4/21/2020 REMOVED CORROSION FROM SERVICE DOOR LOWER SILL ANGLEFROM FS319.00 TO FS349.00 REF CRJ 200 SRM. EVALUATED AND FOUND SDR SWAA2020042032843Floor Support · crackedFLOOR SUPPORT CRACKED AT BS 344-360 BL0 WL 208 / REMOVED CRACK DAMAGED FLOOR SUPPORT AT BS 344-360 BL 0 WL 208 IAW SRM 51-40-02-0G-0 LOCATED AND DRILLED NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0 INSTALLED FLOOR SUPPORT IAW SRM 51-40-02-0G-0 AND BOEING DWG 141A54SDR SWIA2020041750161Door Sill · corroded* L/H SIDE FUSELAGE PRESSURE FLOOR SILL HAS AREAS OF CORROSION IN BETWEEN FS 409+128 TO 559.0. (C-CHECK) RO 4/16/2020 BLENDED 9 EA AREAS OF CORROSION ON L/H PRESSURE FLOOR SILL BETWEEN FS409+128 AND FS559 REF BOMBARDIER REO. ALL BLENDS EVALED IN LIMITS ANDSDR SIMA2020041618005Structure · corrodedTDMI 607T5323 ORIGNAL LG PG 4475656/3 TRANSFERRED FROM NRTC E710113, COCKPIT UNDERFLOOR BETWEEN FRAMES 13 AND 14 AND STRINGERS 20R AND 18L HAS SURFACE CORROSION ERS-EM-53MR-3758 PTB TRANSFERRED TO NRTC E782419 C BRODA 460360. UPGRADED TO A MAJOR REPAIR REFERENSDR R61A202004010476Panel Support · corroded***AIRCRAFT IS IN HEAVY CHECK*** CF III, CORROSION FOUND AT PANEL SUPPORT BTW FR 88-90, LBL 36. REPLACED PANEWL SUPPORT IAW SRM 51-41-01, 51-42-01 AND 51-43-03. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR R61A202004010475Shear Panel · corroded***AIRCRAFT IS IN HEAVY CHECK*** CF III, CORROSION FOUND ON MIDDLE SHEAR PANEL BTW FR 87-88 ANDS BTW RBL 12 AND LBL 12. REPLACED SHEAR PANEL IAW SRM 51-42-01 & 51-43-03. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR R61A202004010467Shear Panel · corroded***AIRCRAFT IS IN HEAVY CHECK*** CABIN FLOOR STRUCTURE, CORROSION FOUND AT R/H SHEAR PANEL BTW FR 87-88 ND BTW RBL 12-36. REPLACED SHEAR PANEL IAW SRM 51-42-01/02 & 51-43-03. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR R61A202004010465Upper Sheet · corroded***AIRCRAFT IS IN HEAVY CHECK*** CF III, CORROSION FOUND AT UPPER SHEET BTW FR 85-86 RBL 12. REPLACED UPPER SHEET IAW SRM 51-43-03 AND 51-41-01.***AIRCRAFT REMAINS IN HEAVY CHECK***SDR ASAA2020033132573Door Sill · corrodedAFT BAGGAGE PIT DOOR SILL WEB HAS NUMEROUS AREAS OF CORROSION. GROUNDED - YES. REMOVED CORROSION ON AFT BAGGAGE PIT DOOR SILL WEB ORIG THICKNESS .050 PER B737-900ER SRM 53-06-15-0I-1, REMAINING MATERIAL .026 REMOVED .024 MATERIAL FOUND TO BE OUT OF LIMITS PER SDR SWAA2020032442709Vapor Barrier · crackedRH WHEEL WELL CENTER WING REAR SPAR VAPOR WEB CRACKED 8" LONG FROM LOWER ROW OF FASTENERS BEHIND HYDRALIC SERVICE HAND PUMP C/W INTERIM SEAL APPLIED SPEED TAPE TO DAMAGED AREA IAW SRM 57-10-10-1A-2 PAR. 2.C. (4) (A). DO A VISUAL INSPECTION OF REPAIR ARSDR AALA202003249014Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FORWARD CARGO COMPARTMENT INTERCOSTAL AT BS 500D AND S25R. REPLACED INTERCOSTAL PER SRM 51-40-02.SDR SWAA2020032332543Stiffener · crackedLEFT MAIN WHEEL WELL STIFFENER CRACKED STA 663 LBL 24 / REMOVED AND REPLACED LH WHEEL WELL STIFFENER AT STA 663 I.A.W SRM 51-40-02SDR DALA2020032001949Door Sill · corrodedCORROSION LOWER SILL AT LEVEL OF FR 68 AND STR 23RH AT AFT GALLEY AREA, REPLACED LOWER SILL AT LEVEL OF FR 66 TO FR 68 AND STR 23R/H AT AFT GALLEY AREA AS PER A320 SRM 51-72-11 AND DWG #D53480505SDR AALA202003199020Strap · corrodedAIRCRAFT WAS GROUNDED: CORROSION ON FORWARD CARGO DOOR CUT OUT SEAL STRAP AT FR 27 AND S39R NEAR THE FORWARD LOCK FITTING. REPLACED SEAL STRAP PER SRM 51-42-11.SDR SWAA2021081732512Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A- BS500D RBL23 WL156. MARKED / REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT AND INSTALL NEW FLOOR TO SIDEWALL SUPPORT AT BS 500A-500D RBL 23 WL 156 IAW SRM 51-40-02-0G-0 AND DWG 143A7505SDR SWAA2021081032059Support Bracket · crackedAFT DOOR SILL DRAIN BLADDER HOSE SUPPORT BRACKET IS CRACKED / REMOVED AND REPLACED AFT DOOR SILL DRAIN BLADDER HOSE SUPPORT BRACKET I.A.W SRM 51-40-02-0G-0 AND BOEING DWG # 417A2106SDR R61A2020060300515Threshold · corrodedCORROSION AS MARKED ON CENTER THRESHOLD TRIM SUPPORT ON AFT PASSENGER DOOR. REMOVED AND REPLACED CENTER THRESHOLD REF SRM 51-40-08, APPLIED SURFACE PROTECTION REF SRM 51-23-06. SEE W/O H7207 SN 462 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR R61A20200603005Support · corrodedCORROSION AS MARKED ON CENTER THRESHOLD TRIM SUPPORT ON AFT PASSENGER DOOR. REMOVED AND REPLACED CENTER THRESHOLD REF SRM 51-40-08, APPLIED SURFACE PROTECTION REF SRM 51-23-06. SEE W/O H7207 SN 462 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR SWIA202005210861Support Angle · crackedFS 621 ON FWD SIDE OF PRESSURE BULKHEAD, R/H SIDE FLOOR LEVEL FLOOR SUPPORT ANGLE CRACKED. (C-CHECK) RO 5/16/2020 COMPLIED WITH PERMANENT REPAIR OF F.S. 621 ON FWD SIDE OF PRESSURE BULKHEAD R/H FLOOR LEVEL SUPPORT BRACKET ANGLE CRACKED IAW BOMBARDIER REO ASDR SWIA202005190732Angle · corroded*PASSENGER DOOR CUTOUT LOWER SILL ANGLE HAS AREAS OF CORROSION. (MARKED) (C-CHECK) RO 5/16/2020 REMOVED AND INSTALLED NEW PAX DOOR LOWER SILL ANGLE IAW CRJ 900 SRM AND BOMBARDIER DWG. COMPLIED WITH TASK CARDSDR SWIA202005140700Door Sill · corrodedBACKUP SILL CORRODED ON STGR 19R BETWEEN FS319 TO FS310. (C-CHECK) RO 5/10/2020 REMOVED CORRODED BACKUP SILL ON STGR 19R BETWEEN FS319.00 TO FS310.00 AND REPLACED WITH NEW REFERENCING BOMBARDIER DWG AND CRJ 900 SRM. COMPLIED WITH SKYWEST TASK CARD. COMPLSDR SWIA2020042850414Structure · corrodedDURING SCREW EXTRACTION FOUND CORROSION AROUND FASTENER HOLE AT FS 409.00 + 98 LBL 9 ( FLAGGED ) (48 MO INSP) RO 4/23/2020 REPAIRED FASTENER HOLE LOCATION AT F.S. 409.00+96 LBL 9 IAW BOMBARDIER REO ACCOMPLISHED HFEC IAW CRJ200 NTM. NDN ACCOMPLSHED U/T THICSDR SWIA2020042750401Angle · corrodedAFT PAX DOOR FLOOR SILL CAP ANGLE CORRODED AT APPROX F.S.349.00 AT FLOOR SILL AREA. (C-CHECK) RO 4/23/2020 REPLACED ANGLE WITH NEW FROM STOCK REF CRJ 900 SRM.SDR SWIA2020042750400Angle · corrodedFWD CAP ANGLE ON PAX DOOR FLOOR SILL AREA AT APPROX F.S 310.00 CORRODED AWAY ALONG EDGE. THERE IS NO REPAIR AVAILIBLE , REPLACE PART. (C-CHECK) RO 4/23/2020 REPLACED CAP ANGLE WITH NEW FROM STOCK REF CRJ 900 SRMSDR SWIA202042350262Door Sill · corroded* THE LH FLOOR SILL BETWEEN FS295.00 AND FS310.00 HAS CORROSION. (MARKED) (C-CHECK) RO 4/21/2020 BLENDED CORROSION AT 2EA. LOCATIONS ON THE LH FLOOR SILL BETWEEN FS295.00 AND FS310.00 REF BOMBARDIER REO. EVALUATED AND FOUND THE BLEND LOCATION #1 AT FS303,SDR SWIA2020042350253Intercostal · cracked* INTERCOSTAL ABOVE PRESSURE FLOOR AT FS 484.00 BETWEEN RBL 27 AND RBL 36 HAS CRACKED ATTACHMENT CLIP AT INB END. (C-CHECK) RO 4/21/2020 REMOVED AND REPLACED INTERCOSTAL ABOVE PRESSURE FLOOR AT FS 484.00 BETWEEN RBL 27 AND RBL 36 ATTACHMENT CLIP PN #601R3SDR SWIA2020042350226Intercostal · cracked*FS 625 INTERCOSTAL AT STR 14L NEXT TO SKIN CRACKED (C-CHECK) RO 4/21/2020 REMOVED AND INSTALLED NEW INTERCOSTAL AT FS625.00 STGR14L. REF C RJ200 SRM AND DWG. COMPLIED WITH TASK CARD. SEE CONTINUATION FOR DETAILS.SDR SWIA2020042350225Post · defectiveF.S 409.0+128 RBL 18 OUTB AFT RADIUS OF VERTICAL POST DEFECT NOTED. (C-CHECK) RO 4/21/2020 REMOVED THE VERTICAL POST AT FS 409.00+128 RBL18 PER REF: CRJ200 SRM. - INSTALLED NEW VERTICAL POST AT FS 409-.00+128 RBL18 PER REF: BOMBARDIER DWG IN CONJUNCTION WSDR SWIA2020042350222Door Sill · cracked*CARGO DOOR LOWER SILL HAS CORROSION AROUND NUTPLATE HOLES (C-CHECK) RO 4/21/2020 REMOVED CORROSION AT CARGO DOOR LOWER SILL AROUND NUTPLATES REF CRJ200 SRM. FOUND SILL TO BE CRACKED. REMOVED CRACKED CARGO DOOR SILL AND INSTALLED NEW SILL REF DWG, AND REO.SDR SWIA2020042350218Floor Support · corroded*FLOOR BEAM CAP FS 570- 610 LBL 27 CORRODED AROUND NUTPLATE HOLES (C-CHECK) RO 4/21/2020 REMOVED CORROSION ON FLOOR BEAM CAP FS570 - FS610 LBL27 REF CRJ 200 SRM. EVALUATED AND FOUND TO BE OUT OF LIMITS, REF CRJ 200 SRM AND BOMBARDIER STANDARDS MANUAL. REMOSDR SWIA2020042350217Door Sill · corroded*FLOOR EDGE MEMBER FROM FS 559+80 - 621 RH HAS CORROSION AROUND NUTPLATE HOLES (C-CHECK) RO 4/21/2020 REMOVED CORROSION FROM FLOOR EDGE MEMBER FROM FS559+80 TO FS621.00 RH. REF: CRJ-200 SRM. FOUND TO BE OUT OF LIMITS. REF: REO. REPLACED FLOOR SILL SECTIONSDR SWIA2020042350216Attach Fitting · cracked* INTERCOSTAL ABOVE PRESSURE FLOOR AT FS 484.00 BETWEEN LBL 27 AND LBL 36 HAS CRACKED ATTACHMENT CLIP AT OBD END. (C-CHECK) RO 4/21/2020 REMOVED CRACKED ATTACHMENT CLIP AT OTBD END OF INTERCOSTAL ABOVE PRESSURE FLOOR FS484.00 BETWEEN LBL 27 AND LBL 36. FABSDR SWIA2020042350215Attach Fitting · cracked* INTERCOSTAL ABOVE PRESSURE FLOOR AT FS 484.00 BETWEEN RBL 27 AND RBL 36 HAS CRACKED ATTACHMENT CLIP AT OBD END. (C-CHECK) RO 4/21/2020 REMOVED CRACKED ATTACHMENT CLIP AT OTBD END OF INTERCOSTAL ABOVE PRESSURE FLOOR FS484.00 BETWEEN RBL 27 AND RBL 36. FABSDR SWIA2020042350214Door Sill · corroded*FS559.00 RH STRAP FROM RBL27 TO FLOOR SILL IS CORRODED IN SEVERAL AREAS (MARKED) (C-CHECK) RO 4/21/2020 REMOVED CORROSION. ORIGINAL THICKNESS OF RH FLOOR STRAP RBL 27 AT FS 559 IS .050". REMAINING MATERIAL IS .036". REMOVED .014" WITH MAX ALLOWABLE 10%. SDR SWIA2020042350213Door Sill · corroded*FS559.00 LH STRAP FROM LBL27 TO FLOOR SILL IS CORRODED IN SEVERAL AREAS (MARKED) (C-CHECK) RO 4/21/2020 REMOVED CORROSION FROM FS559.00 LH STRAP FROM LBL27 TO FLOOR SILL REF CRJ200 SRM. ORIGINAL THICKNESS OF LH FLOOR STRAP AT LBL27 AND FS 559 IS .050" SDR SWIA2020042350208Support · cracked* THE LH WINDSHIELD SIDE POST SUPPORT IS CRACKED. (MARKED) (C-CHECK) RO 4/21/2020 ACCESSED AND REMOVED LH WINDSHIELD SIDE POST SUPPORT REF CRJ 200 SRM. - INSTALLED LH WINDSHIELD SIDE POST SUPPORT REF CRJ 200 SRM AND DRAWING. RESTORED ACCESS OPERATIONALSDR SWAA2020042032515Intercostal · corroded***CORROSION*** ON INTERCOSTAL AT MAIN EBAY BS330-BS344 S-23L WL161. MARKED / DAMAGE EVALUATION ON MAIN EBAY INTERCOSTAL BS330-344; S-23L; WL161. REMOVED .016' OUT OF .063'; .047' MATERIAL REMAINING. OUT OF LIMITS PER SRM 53-10-15. REMOVED AND INSTALLED NEW INSDR SWAA2020042032498Support · corroded***CORROSION*** CORROSION ON FLOOR TO SIDEWALL SUPPORT AT BS 437; RBL 24; WL 156 (MARKED) / REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT/SHIELD ASSY B.S. 420-440 RBL 24 WL 156 PER SRM 51-40-05-0G-0 SRM 51-40-02-0G-0 AND DWG 143A0080SDR SWAA2020042032528Support Bracket · crackedRIGHT ECS BAY HAS CRACKED DUCT SUPPORT BRACKET ACCESS PANEL 192CR BS540+6 RBL8. MARKED / REMOVED AND REPLACED ECS BAY DUCT SUPPORT BRACKET ATBS 540+6 RBL8 IAW SRM 51-40-02-0G-0 AND AIPC 36-13-01-01ASDR SWAA2020042032514Intercostal · corroded***CORROSION*** ON INTERCOSTAL AT MAIN EBAY BS312-BS322 S-23L WL161. MARKED / REMOVED CORROSION - .013' OUT OF .063' ORGINAL THICKNESS; .050' REMAINING THICKNESS - OUT OF LIMITS PER SRM 53-10-15-1A-1. REPLACED WITH NEW INTERCOSTAL PER SRM 51-40-02 AND DRW. 141
Back to JASC 5320