What was found
* THE LH FLOOR SILL BETWEEN FS295.00 AND FS310.00 HAS CORROSION. (MARKED) (C-CHECK) RO 4/21/2020 BLENDED CORROSION AT 2EA. LOCATIONS ON THE LH FLOOR SILL BETWEEN FS295.00 AND FS310.00 REF BOMBARDIER REO. EVALUATED AND FOUND THE BLEND LOCATION #1 AT FS303, LBL43 IS WITHIN LIMITS AND BLEND LOCATION #2 AT FS310, LBL41 IS OUT OF LIMITS REF BOMBARDIER REO. REPAIRED BLEND LOCATION #2 AT FS310, LBL41 PER BOMBARDIER REO. COMPLETED ALL STEPS OF BOMBARDIER REO. SEE CONTINUATION CARD FOR DETAILS.