Service difficulty report · Door Sill · Cndair CL6002B19

Difficulty date
March 17, 2020
Submitted
April 23, 2020
Operation
Air carrier
Aircraft
N983SW
Make and model
Cndair CL6002B19
Aircraft serial
7961
Aircraft time
40,302 hours, 34,270 cycles
Part
Door Sill
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

*FS559.00 LH STRAP FROM LBL27 TO FLOOR SILL IS CORRODED IN SEVERAL AREAS (MARKED) (C-CHECK) RO 4/21/2020 REMOVED CORROSION FROM FS559.00 LH STRAP FROM LBL27 TO FLOOR SILL REF CRJ200 SRM. ORIGINAL THICKNESS OF LH FLOOR STRAP AT LBL27 AND FS 559 IS .050" REF CRJ 200 SRM, AMOUNT REMAINING IS .031" REF NDT, REMOVED .019" AND MAX ALLOWABLE IS .005" THEREFORE OUT OF LIMITS OF CRJ 200 SRM. . REMOVED AND WET INSTALLED NEW FS559.00 LH STRAP. REPLACED 1EA DOME NUTPLATE GOING THROUGH PRESSURE FLOOR AREA. REF: BOMBARDIER DWG AND CRJ200 SRM